This is a salient characteristics document specifying requirements for two pieces of laboratory equipment to be procured by the Department of the Army Materiel Command. The document details technical specifications for an oligonucleotide cleavage and deprotection oven/chamber and an oligonucleotide purification system.

The required equipment includes a cleavage/deprotection oven that must provide programmable temperature control up to 85°C, timed reaction control, user-controlled heat and pressure settings, compatibility with various deprotection methods (ammonia-based, ammonia-free, and liquid), and gas control features. The purification system must handle 8+ oligonucleotides per run, dispense from 5+ reagent bottles, provide automated reagent dispensing, use reusable commercial purification columns/cartridges, allow flexible programming, and enable desalting and collection capabilities. Both items require onsite/virtual training, user manuals, standard protocols, maintenance procedures, and shipping/installation. The equipment will be delivered to ARL-South in Austin, TX.

View the file

Other files

File Type Posted
Sources Sought Document - Oligonucleotide 1.doc DOC document

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Salient Characteristics

Commercial Availability Certification:

I have evaluated the commercial marketplace and determined that all of the salient characteristics documented below are available in products/services offered in the commercial marketplace.

Signature (typed name): To Be Announced After Award Technical Point of Contact (TPOC) or Contracting Officer’s Representative (COR)

The contractor shall provide the following requirements for the systems, as described below:

One (1) Oligonucleotide cleavage and deprotection oven/chamber shall include the following Salient characteristics:

· Programmable control of chamber temperature of up to 85 degrees Celsius.

· Must facilitate the timed control of reaction conditions.

· Must allow for user control of heat and pressure within the reaction chamber.

· Must be compatible with oligonucleotide cleavage and deprotection via standard methods under a variety of conditions including ammonia-based, ammonia-free, and liquid deprotection.

· Must include input and output gas controls for the reaction chamber.

· Onsite or Virtual user training including complete user manuals, available standard protocols, and routine maintenance procedures.

· Shipping and Installation included.

One (1) Oligonucleotide purification system shall include the following Salient characteristics:

· Must be able to purify at least eight (8) different oligonucleotides per run cycle.

· Must be able to dispense from at least five (5) attached reagent bottles.

· Must automatically dispense reagents to the purification columns or cartridges to facilitate the purification of oligonucleotides.

· Must utilize reusable commercially available oligonucleotide purification columns or cartridges to purify oligonucleotides to high purity and quality.

· Must allow for flexible programming of purification conditions.

· Must allow for desalting, purification and collection of synthetic oligonucleotides.

· Onsite or Virtual user training including complete user manuals, available standard protocols, and routine maintenance procedures.

· Shipping and Installation included.