This document presents the salient characteristics specification for an explosive ordinance disposal (EOD) identification equipment procurement. The system must be man-portable and housed in ruggedized transport cases with weight manageable by EOD team personnel. The equipment must operate entirely on battery power in the field, including the X-ray source, detector, and control laptop, and include multi-bay chargers for field sustainability.
The system must feature a battery-powered, portable pulsed X-ray source with a minimum output of 270kV (with the Golden XRS-3 cited as an example), paired with a large-format approximately 12"x17" amorphous silicon flat panel detector capable of producing high-resolution images for detailed internal component analysis of suspect packages. The system must support both wireless and wired operation with a minimum 50-meter wired capability, controlled via a ruggedized laptop such as a Panasonic Toughbook. The complete system delivery must include a tripod, communication reels, batteries, multi-bay chargers, and custom tactical transport cases for all components. Temperature, volume/capacity, and warranty requirements are marked as not applicable.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Clauses FA487726QA103.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SALIENT CHARACTERISTICS
Explosive ordinance identifying equipment must meet or exceed the following salient characteristics:
Dimensions: Must be a man-portable system housed in ruggedized transport cases.
Weight: Must be man-portable by an EOD team.
Electrical Requirements: Entire system must be battery-operated for field use, including the X-ray source, detector, and control laptop. Must include multi-bay chargers.
Temperature: Not Applicable
Volume/Capacity: Not Applicable
Warranty: Not Applicable
Features:
• System must be capable of wireless and wired (minimum 50m) operation.
• Must include a ruggedized laptop (e.g., Panasonic Toughbook) for system control and image analysis.
• System must be delivered in custom, rugged transport cases for all components.
• Must provide high-resolution images for detailed analysis of internal components of suspect packages.
• System must be delivered in custom, rugged transport cases for all components.
• Must provide high-resolution images for detailed analysis of internal components of suspect packages.
• Must be a battery-powered, portable pulsed X-ray source with an output of at least
270kV (e.g., Golden XRS-3).
• Must be a large format (approx. 12"x17") amorphous Silicon (a-Si) flat panel detector.
Accessories:
• Must be a complete system including a tripod, communication reels, batteries, chargers, and tactical cases.