MOC Recorded Line Equipment Salient Characteristics (Digital Logging Recorder)

Dated 16 March 2023

- System Requirements o The MOC DLR system shall meet the following minimum performance and physical requirements.

- Storage o The contractor shall provide a DLR System with internal storage of 1TB. The solution will also provide a software backup storage application to provide recordings to a GFE provided Storage Area Network (SAN) as well.

- 19” Rack Mountable Shelf o The contractor shall provide a 19” rack mountable shelf and will engineer, install, test, and integrate the DLR System provided in this shelf. This shelf will be collocated near the MOC to allow for wiring integration within required distances.

- Recording Access & Playback o The contractor shall provide a single concurrent recording license with the solution. Any GFE computer on the same LAN as the DLR server will be able access the DLR Recordings one at a time.

- Voice Switching System Interoperability o The DLR shall be on the Joint Interoperability Test Command (JITC) Approved Product List (APL). The system shall be interoperable with and directly interconnect to Host Voice Switching Systems (VSS) or Cyber Transport System (CTS) that performs the base level voice communications and unified capabilities. At a minimum the system shall directly interface with base Local Session Controller (LSC), and allow Multi-Function Soft Switches (MFSS), WAN Soft Switches (WANSS), Multi-Function Switches (MFS), Local Session Controllers (LSC), End Offices (EOs), Base Command Post System, and PBXs with use of analog phone set interface without the addition of a PBX or LSC.

- Dimensions o The core backroom/server equipment shall be 19–inch rack mountable to the maximum extent possible. The equipment shall adhere to best commercial practices when not rack mountable.

Dated 16 March 2023
- System Requirements
- Storage
- 19” Rack Mountable Shelf
- Recording Access & Playback
- Voice Switching System Interoperability
- Dimensions