Salient Characteristics Mobile Denial Barriers (2).pdf

PDF 21 KB Posted

Attached to
Mobile Denial Barriers
Solicitation number
M263816932572
Issued by

About this file

This document is a statement of salient characteristics for Mobile Denial Barriers dated April 16, 2026, distributed to the Department of Defense community only.

The mobile denial barrier must be 16 feet in length and towable by trailer hitch with a spare tire, four-wheel hydraulic brakes, and a Vehicle Identification Number. The system requires a 24-volt battery-operated hydraulic pump with control station and must be remote-operated with a minimum 20-foot cable, at least 300 feet of spare cable, and an auxiliary limit switch. Power capabilities must include multiple options: batteries, solar panels, traditional plug-in connections, and both 12-volt and 24-volt solar charge controllers. Additional required components include a 12-volt booster pack, signal lights (capable of external powering), jumper cables, and utility outlet connections. The barrier must include a portable bollard to extend the protection zone and a barrier turntable. All components must be galvanized, and complete instructions with a startup and troubleshooting manual must be provided. The system must meet ASTM F 2656-07 M40 Standards and be rapidly deployable.

View the file

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Salient Characteristics Mobile Denial Barriers 20260416

Required Characteristics

— 24V Battery Operated Hydraulic Pump W/Control Station

— The basic structure must be l6ft in length

— Barrier must be towable by trailer hitch, include a spare tire, 4—wheel hydraulic breaks & VIN Number

— Must include complete instructions and a start—up/trouble shooting manual

— Must be remote operated with a minimum 2Oft cable

— Must include at least SOOft of spare cable

— Must include an auxiliary limit switch

- Must include a 12v booster pack

— Must include signal lights (can be powered externally)

— Must have multiple power options to include batteries, solar panels, and traditional plug—in Must include both 12V and 24V Solar Charge Controllers Mobile Barriers must be galvanized Jumper cables and utility outlet connections must be included

— Must include a portable bollard that extends the barrier protection zone

— Must include a barrier turn table

— Must meet ASTM F 2656—07 M40 Standards

- Must be rapidly deployable

609/6

DISTRIBUTION: Dow COMMUNITY ONLY