This document is a salient characteristics specification for a Commercial Hot Water Sewer Jetter Trailer (BLD.896) outlining detailed performance requirements and component specifications for a mobile sewer cleaning system.
The system must deliver a minimum of 3,500 PSI at 22 GPM and be capable of clearing commercial sewer lines up to 18 inches in diameter with an integrated pulsation system. The equipment requires dual commercial-grade Kohler ECH980 gas engines with electric start and dual ceramic plunger pumps driven by a poly chain drive, supported by two 6.5-gallon fuel tanks and an onboard battery system. The heating system must include a 12-volt diesel-fired burner (Beckett or equivalent) providing a minimum 130°F temperature rise to reach 195°F maximum, utilizing a Schedule 80 heating coil with stainless steel protection and an 8.5-gallon diesel fuel tank with cleanable filter. The water supply comprises a 500-gallon onboard tank with automatic overflow shutoff and low-water shutdown protection, controlled via a NEMA 4 rated watertight control panel with foot pedal valve and adjustable pressure controls. The trailer configuration is a 5' x 12' tandem axle unit with steel diamond-plate flooring, dual 3,500 lb leaf spring axles with electric brakes, 15-inch 6-ply tires, and DOT-compliant LED lighting. Equipment includes a 12-volt electric main jetter reel with 400 feet of 1/2-inch sewer hose, two secondary reels for 200 feet of high-pressure hose and 100 feet of 3/4-inch garden hose, 50-foot wash-down hose with gun and wand, two 6-piece nozzle kits with cleaners, and a deluxe tongue-mounted tool box.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| CSS_26QB151.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SALIENT CHARACTERISTICS: Commercial Hot Water Sewer Jetter Trailer
BLD.896
1. Overall System Performance & Capabilities
Operating Output: System must deliver a minimum high-pressure output of 3,500 PSI at a flow rate of 22 Gallons Per Minute (GPM).
Pipe Capacity: Must be capable of clearing and cleaning commercial sewer lines up to 18 inches in diameter.
Pulsation Feature: Must include an integrated pulsation system (e.g., Aqua Pulse or equivalent) to assist the hose in navigating pipe bends and breaking up blockages.
2. Engine and Pump Subsystem
Engines: Must feature dual (2) commercial-grade gas engines (Kohler ECH980 or equivalent) with electric start capabilities.
Pumps: Must feature dual (2) ceramic plunger pumps (General Pump or equivalent) driven by a poly chain drive system.
Fuel Storage: Must include two (2) gas fuel tanks with a minimum capacity of 6.5 gallons each.
Power Supply: Must include an onboard battery system housed in a dedicated battery box.
3. Heating System
Burner: Must feature a 12-volt diesel-fired burner (Beckett or equivalent).
Heating Capacity: Must provide a minimum temperature heat rise of 130°F, reaching a maximum temperature of 195°F, controlled via an adjustable thermostat.
Coil & Hardware: Must utilize a Schedule 80 heating coil protected by a stainless steel cover.
Fuel Storage & Filtration: Must include a minimum 8.5-gallon diesel fuel tank with a cleanable fuel filter.
4. Water Supply and Controls
Water Tank: Must include a minimum 500-gallon onboard water tank with complete integrated plumbing.
System Protection: Must feature an automatic tank overflow shutoff and a low-water shutdown mechanism to protect the pumps from running dry.
Operator Controls: Must include a NEMA 4 rated watertight control panel.
Flow Control: Must include a foot pedal valve for hands-free water flow operation and adjustable pressure controls.
5. Hoses, Reels, and Accessories
Main Jetter Reel: Must feature a 12-volt electric hose reel with a hose guide, spooled with a minimum of 400 feet of 1/2-inch low-friction sewer jetting hose.
Secondary Reels: Must include two (2) rear-stacked mounted hose reels designed to hold a minimum of 200 feet of high-pressure hose and 100 feet of 3/4-inch garden hose.
Wash-Down Equipment: Must include a minimum 50-foot wash-down hose complete with a wash-down gun, wand, and tips.
Nozzle Kits: Must include a minimum of two (2) 6-piece sewer nozzle kits with cleaners (specifically sized for 23.5 and 12.0 orifices).
Storage: Must include a deluxe tongue-mounted tool box for secure storage of accessories.
6. Trailer Specifications
Dimensions & Build: Must be a 5' x 12' tandem axle trailer featuring a steel diamond-plate floor, low-rise rails for easy operational access, and a safer V-braced tongue.
Suspension & Brakes: Must feature dual 3,500 lb leaf spring "easy ride" axles equipped with electric trailer brakes.
Towing Interface: Must utilize a 2-inch ball hitch and a standard 7-PIN electrical connection.
Wheels & Lighting: Must be equipped with 15-inch, 6-ply tires mounted on painted steel wheels and feature DOT-compliant LED trailer lighting.