Salient Characteristics for Low Phase Noise Signal Generator.docx
DOCX document 21 KB Posted
- Attached to
- Low Phase Noise Signal Generator
- Solicitation number
- FA480924Q0081
About this file
This document outlines the salient characteristics required for a low phase noise signal generator to be considered an equal to the Agilent Technologies E8663D. The key requirements include:
Frequency range of 100 kHz to 3.2 GHz, harmonics accuracy specifications over various frequency ranges, improved harmonics below 2 GHz, and capability for AM, FM, phase modulation, and LF output. The signal generator must also comply with minimum use specifications in referenced Technical Orders.
The related federal contract opportunity is for a Low Phase Noise Signal Generator capable of generating signals over the frequency range of 100 kHz to 3 GHz, with continuous wave (CW) capabilities, high stability time-base, and ultra-low phase noise. The solicitation is issued by the Department of the Air Force Air Combat Command.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Solicitation - FA480924Q0081.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Salient Characteristics for Low Phase Noise Signal Generator
· Agilent Technologies E8663D or equal
· To be considered an equal, the following minimum salient characteristics have to be met:
· Frequency range of 100 kHz to 3.2 GHz
· Harmonics Accuracy that meets or exceeds: < -10 dBc from 100 kHz to <1 MHz; < -25 dBc from 1 MHz to <10 MHz; < -30 dBc from 10 MHz to 3 GHz
· Output Power Accuracy that meets or exceeds:
| Power Range |
| Frequency |
| Accuracy |
| -90 dBm to ≥+7 dBm |
| 100 kHz to <250 kHz |
| ±3 dB |
| -90 dBm to ≥+13 dBm |
| 250 kHz to <1 MHz |
| ±3 dB |
| -90 dBm to ≥+13 dBm |
| 1 MHz to <1 GHz |
| ±1 dB |
| -90 dBm to ≥+13 dBm |
| 1 GHz to 3 GHz |
| ±1.5 dB |
· Continuous wave (CW) capabilities with high stability time-base and ultra-low phase noise.
· Phase Noise Accuracy that meets or exceeds:
Frequency Offset from Carrier
| (MHz)1 |
| 10 (Hz) |
| 100 (Hz) |
| 1 (kHz) |
| 10 (kHz) |
| 100 (kHz) |
| 1 (MHz) |
| 10 (MHz) |
| ≤15.625 |
| -39 |
| -70 |
| -100 |
| -126 |
| -134 |
| -136 |
| -138 |
| >15.625 to ≤31.25 |
| -39 |
| -70 |
| -100 |
| -126 |
| -134 |
| -136 |
| -138 |
| >31.25 to ≤62.5 |
| -39 |
| -70 |
| -100 |
| -126 |
| -134 |
| -136 |
| -138 |
| >62.5 to ≤125 |
| -39 |
| -70 |
| -100 |
| -126 |
| -134 |
| -136 |
| -138 |
| >125 to ≤250 |
| -50 |
| -83 |
| -115 |
| -141 |
| -148 |
| -150 |
| -150 |
| >250 to ≤500 |
| -48 |
| -78 |
| -109 |
| -135 |
| -145 |
| -150 |
| -151 |
| >500 to ≤1000 |
| -41 |
| -73 |
| -104 |
| -130 |
| -141 |
| -150 |
| -153 |
| >1000 to ≤2000 |
| -35 |
| -67 |
| -96 |
| -123 |
| -134 |
| -147 |
| -156 |
| >2000 to ≤3000 |
| -29 |
| -62 |
| -92 |
| -119 |
| -130 |
| -143 |
| -155 |
1. At carriers ≤10 MHz, the offset farthest from the carrier would be limited to 0.99 x carrier frequency
· Improved harmonics below 2 GHz (low-pass filters)
· AM, FM, phase modulation, and LF output
· Comply with minimum use specifications in Technical Orders (TOs) 33K4-4-859-1, 33K4-4-912-1, 33K3-4-3762-1, and 33K3-4-3356-1.