Salient Characteristics of Expeditionary Airlift Container (EAC) Workshop
This document is a specification document outlining the minimum essential characteristics required for an Expeditionary Airlift Container (EAC) Workshop, with Highland Engineering, Inc. EAC Workshop (Style B), Part Number 701-20923-WS-B, identified as the reference product.
The EAC Workshop is a mobile military cargo container designed for expeditionary maintenance operations. The container must have exact external dimensions of 108" L x 88" W x 90" H in Desert Tan exterior color to maintain compatibility with standard military cargo footprints. The unit comprises a work bench counter with aluminum frame and locking caster wheels, a 6-drawer cabinet, 2 overhead locking cabinets, 2 10-drawer aluminum cabinets with locking casters, and 1 large aluminum closet with four shelves, all featuring black aluminum construction. The container must possess current Air Transportability Test Loading Agency (ATTLA) certification for USAF internal airlift on C-130, C-17, and C-5 aircraft and support a minimum cargo payload capacity of 10,000 lbs with a total maximum gross weight rating of at least 11,515 lbs. Additional mandatory features include 463L cargo pallet compatible rails with flat bottom and 4-way forklift pocket access, integrated corner lifting/tiedown eyes and winching rings, two heavy-duty anti-racking doors on a single short side, open-floor interior design with approximately 395 cubic feet of volume and no central dividing wall, pre-wired internal power distribution with LED lighting and tactical blackout switching, factory-provisioned integration ports for military Environmental Control Units (ECUs) and HVAC systems, and ruggedized interior workshop fixtures including workbenches, secure tool drawer systems, and customizable wall-mounted storage panels. Technical questions should be directed to Mr. Brian Bowler, Contingency Operations Program Manager, at (850) 884-5975 or brian.bowler.1@us.af.mil.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Solicitation - FA441726Q0135.pdf | ||
| Salient Characteristics Portable Field Shower Set with Sinks.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Salient Characteristics of Expeditionary Airlift Container (EAC) Workshop
Project/Requirement: Expeditionary Airlift Container (EAC) Workshop Reference Make/Model: Highland Engineering, Inc. EAC Workshop (Style B) – or similar product Reference Part Number: 701-20923-WS-B
Instructions for Evaluators: To be considered for award, an "equal" product must meet or exceed all of the following minimum essential characteristics.
Nomenclature overview:
• 1 - work bench counter; 24”D, 36”H, 60”W. Aluminum frame, locking caster wheels for mobility and stability, and 2”x 60” brown wooden counter-top
• 1 – 6 drawer cabinet under bench; black frame, black aluminum drawers with steel sliders; width is 36”, height ~30-36” in order to fit flush with bottom of the work bench counters
• 2 – overhead black locking cabinets, 24” in depth, 36” in height, 60” in width; black aluminum frame.
• 2 – 10 drawer aluminum black cabinets, black aluminum drawers with steel sliders.
Locking caster wheels for mobility and stability
• 1 – Large black aluminum closet with four aluminum shelves; 36” in depth, 72” in height, 72” in width. Locking caster wheels for mobility and stability.
• Simple power inlet
• Internal overhead lighting and outlet
Item Required Salient Characteristic
1 Physical Dimensions & Footprint
Must have overall external dimensions of exactly 108” L x 88” W x 90” H to maintain strict compatibility with standard military cargo footprints. Connex exterior color – Desert Tan
2 Airlift Certification Must possess current Air Transportability Test Loading Agency (ATTLA) certification for USAF internal airlift on C-130, C-17, and C-5 aircraft.
3 Material Handling Interface
Base must integrate 463L cargo pallet compatible rails, feature a flat bottom for roller conveyor systems, and include 4-way forklift pocket access.
4 Weight & Payload Capacity
Must support a minimum cargo payload capacity of 10,000 lbs (Total max gross weight rating of at least 11,515 lbs).
5 Rigging & Securing Must include integrated multi-purpose upper corner lifting/tiedown eyes and corner winching rings for tactical loadout.
6 Access & Security Must feature two (2) doors located on a single short side of the container, equipped with heavy-duty anti-racking door locks to secure the payload during turbulent transit.
7 Interior Layout Must provide an open-floor design with approximately 395 cubic feet of internal volume and no central structural dividing wall to maximize active workspace.
8 Electrical & Lighting Must include a pre-wired internal power distribution system and high-efficiency LED interior lighting equipped with tactical blackout switching capabilities.
9 Environmental Control
Must feature factory-provisioned integration ports for immediate external connection to standard military Environmental Control Units (ECUs) / HVAC systems and dehumidifiers.
10 Workshop Outfitting Must include ruggedized interior workshop fixtures including built-in workbenches, heavy-duty secure tool drawer systems, and customizable wall-mounted storage panels.
The requirements within this document will be technically accepted by project manager.