The file is a Salient Characteristics document detailing technical specifications for a handheld communications service monitor. The device must be a portable, battery-powered unit weighing approximately 11 lbs with compact dimensions of 12in X 10in X 5in. Key technical requirements include a touch screen LCD display, multiple connection types (Duplex N-Type RF, BNC for audio input/output, USB, Ethernet), and comprehensive testing capabilities across a 1MHz-6GHz frequency range.
Specific technical features include the ability to perform Voltage Standing Wave Ratio (VSWR) and Distance to Fault (DTF) measurements, display AM/FM/PM modulated signals, and support auto-testing scripts. The device must have a rugged exterior with hoisting capabilities, at least 3 hours of continuous battery operation, VNC access, WiFi with WPA security, and the capability to save signal recordings. This pre-solicitation request is from the Department of the Air Force Air Education and Training Command, seeking a VIAVI CX100 ComXpert or equivalent handheld communications service monitor, with vendors invited to express interest and provide cost estimates.
View the file
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Sheet1
| Salient Characteristics | |
| 1 | Soft Carrying Case with strap for portability above 15ft elevations |
| 2 | Rugged exterior equipment frame with loop(s) to accommodate carabiner clip for hoisting equipment above 15ft elevations |
| 3 | Portable package at ≤ 11lbs; compact size at ≤ 12in X 10in X 5in |
| 4 | Battery powered unit with no less than 3 hours continuous operation per full charge |
| 5 | LCD Display touch screen for ease of navigation in challenging testing environments |
| 6 | Duplex N-Type RF Connection |
| 7 | Audio input BNC connection supporting audio frequency (AF), digital and modulation signals |
| 8 | Audio output BNC connection providing AF signal generation |
| 9 | Antenna/SWR input/output bnc connection for testing lines and forward/reflected power |
| 10 | 10 MHz test connection for verification and calibration purposes |
| 11 | USB connection for transfer of/saving test results and software/firmware equipment upgrades |
| 12 | Ethernet connection for transfer/saving test results and software/firmware equipment upgrades |
| 13 | Power connection for charging battery |
| 14 | Capability to perform Voltage Standing Wave Ratio (VSWR) and Distance to Fault (DTF) measurements on transmission lines |
| 15 | Minimum Frequency Range of 1MHz-6GHz |
| 16 | Ability to display AM/FM/PM Modulated signals |
| 17 | Auto Test Feature allowing technicians to write testing scripts per equipment type and/or location |
| 18 | Virtual Network Computing (VNC) capabilitiesfor accessing equipment from a laptop |
| 19 | WiFi with WPA security capabilities to export information to stand alone laptop of receive firmware updates to testset |
| 20 | Capability to save signal recordings for equipment historical records or training purposes |
| At minimum, the required equipment must have the capabilities listed above |