Salient Characteristics.xlsx

XLSX spreadsheet 12 KB Posted

Attached to
Handheld Communications Service Monitor
Solicitation number
F2M3U24330AC01
Issued by

About this file

The file is a Salient Characteristics document detailing technical specifications for a handheld communications service monitor. The device must be a portable, battery-powered unit weighing approximately 11 lbs with compact dimensions of 12in X 10in X 5in. Key technical requirements include a touch screen LCD display, multiple connection types (Duplex N-Type RF, BNC for audio input/output, USB, Ethernet), and comprehensive testing capabilities across a 1MHz-6GHz frequency range.

Specific technical features include the ability to perform Voltage Standing Wave Ratio (VSWR) and Distance to Fault (DTF) measurements, display AM/FM/PM modulated signals, and support auto-testing scripts. The device must have a rugged exterior with hoisting capabilities, at least 3 hours of continuous battery operation, VNC access, WiFi with WPA security, and the capability to save signal recordings. This pre-solicitation request is from the Department of the Air Force Air Education and Training Command, seeking a VIAVI CX100 ComXpert or equivalent handheld communications service monitor, with vendors invited to express interest and provide cost estimates.

View the file

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Sheet1

Salient Characteristics
1Soft Carrying Case with strap for portability above 15ft elevations
2Rugged exterior equipment frame with loop(s) to accommodate carabiner clip for hoisting equipment above 15ft elevations
3Portable package at ≤ 11lbs; compact size at ≤ 12in X 10in X 5in
4Battery powered unit with no less than 3 hours continuous operation per full charge
5LCD Display touch screen for ease of navigation in challenging testing environments
6Duplex N-Type RF Connection
7Audio input BNC connection supporting audio frequency (AF), digital and modulation signals
8Audio output BNC connection providing AF signal generation
9Antenna/SWR input/output bnc connection for testing lines and forward/reflected power
1010 MHz test connection for verification and calibration purposes
11USB connection for transfer of/saving test results and software/firmware equipment upgrades
12Ethernet connection for transfer/saving test results and software/firmware equipment upgrades
13Power connection for charging battery
14Capability to perform Voltage Standing Wave Ratio (VSWR) and Distance to Fault (DTF) measurements on transmission lines
15Minimum Frequency Range of 1MHz-6GHz
16Ability to display AM/FM/PM Modulated signals
17Auto Test Feature allowing technicians to write testing scripts per equipment type and/or location
18Virtual Network Computing (VNC) capabilitiesfor accessing equipment from a laptop
19WiFi with WPA security capabilities to export information to stand alone laptop of receive firmware updates to testset
20Capability to save signal recordings for equipment historical records or training purposes
At minimum, the required equipment must have the capabilities listed above