Salient Characteristics.pdf
PDF 45 KB Posted
- Attached to
- Air Curtain (with Installation). Qty. 4
- Solicitation number
- W912L7251803
About this file
The document presents Salient Characteristics for Solicitation 25Q1800 for four 72-inch air curtains with specific technical requirements. The air curtains must provide continuous airflow across a 72-inch doorway, achieve a floor-level velocity of at least 1,600 fpm to create an insect barrier, and meet NSF/ANSI 37 standards. Additional requirements include 24/7 operational capability, outdoor suitability with corrosion-resistant materials, and compatibility with 120V single-phase or 208/240/480V three-phase electrical systems.
Key technical specifications mandate that the air curtains include continuous, manual, and automatic activation modes, be designed for direct hard-wiring, and carry manufacturer documentation demonstrating compliance with NSF/ANSI 37 and UL or ETL safety listings. The offeror must provide detailed documentation including installation instructions, wiring diagrams, and mounting hardware, and specify the operating voltage, full load amps, and recommended breaker size for the proposed air curtain units.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Solicitation.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SALIENT CHARACTERISTICS for Solicitation 25Q1800 (Air Curtain, 72", Qty 4)
1. Doorway Coverage: Must provide continuous airflow to fully cover a 72-inch-wide doorway from top to floor.
2. Performance Standard: Must achieve a floor-level velocity sufficient to create a barrier against insects and outside air, meeting NSF/ANSI 37 insect barrier standards (≥1600 fpm at floor).
3. Duty Cycle: Must be rated for continuous 24/7 operation and withstand frequent door cycling during multiple meal services daily.
4. Outdoor Suitability: Must be suitable for outdoor exposure, with corrosion-resistant materials and weather-resistant construction.
5. Electrical Compatibility: Must operate either 120V single-phase or 208/240/480V three-phase, 60 Hz as required by the manufacturer. Offeror must state operating voltage, full load amps, and recommended breaker size.
6. Installation & Documentation: Must be designed for direct hard-wiring. Offeror shall provide installation instructions, wiring diagrams, and mounting hardware.
7. Controls & Operation: Must include continuous, manual, and automatic activation modes (e.g., remote control, door switch, or control panel).
8. Certifications: Must carry manufacturer documentation for complaince with NSF/ANSI 37 and UL or ETL safety listing.