SALIENT CHARACTERISTICS.pdf
PDF 239 KB Posted
- Attached to
- CONEX BOX Federal contract opportunity
- Solicitation number
- SPMYM224Q2103
About this file
This document outlines the salient characteristics for a Damage Control Conex Box (Qty: 6) procurement. The Conex Boxes are required to be new, 20 feet in length, 8.5 feet in height, and 8 feet wide, with corrugated steel sides, roof, and swing doors on one end. The interior specifications include an electrical distribution load center, a heating and cooling unit, framed and insulated walls and ceiling, cabinets, a work bench, and lighting. The equipment must be NRTL (Nationally Recognized Testing Laboratory) certified to comply with OSHA regulations.
The related federal contract opportunity is a solicitation (SPMYM224Q2103) issued by the Defense Logistics Agency (DLA) Maritime Puget Sound Naval Shipyard/TRF Bangor for the procurement of CONEX BOX. The NAICS code is 332312 with a business size standard of 500. The product service code is 8145. The solicitation will be conducted in accordance with FAR Part 12 - Acquisition of Commercial Items and FAR Part 13 - Simplified Acquisition Procedures. Quotes must be submitted via email or fax, and the contractor may be required to comply with NIST SP 800-171 if the items are not deemed to be Commercial Off-The-Shelf (COTS).
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| SPMYM2-24-Q-2103 Amendment 2.pdf | ||
| SPMYM2-24-Q-2103 Amendment.pdf | ||
| Conex Box Drawing.pdf | ||
| EXHIBIT A CDRL.pdf | ||
| SPMYM2-24-Q-2103.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Damage Control Conex Box (Qty:6)
SALIENT CARACTERISTICS
Conex Specifica ons
1.) Conex will be a New Conex, Dimensions will be 20’ in length, 8.5’ in Height, and 8’ Wide.
2.) Corrugated steel sides, roof, and swing doors on one end
3.) Two-way laden forkli pockets
4.) 1 1/8” thick marine plywood floors, forkli tested to 16,000 LBs per 44 square inches
5.) Vents, (2) each per side
6.) Conex exterior will be painted RAL RED.
Interior Back Wall Specifica ons
1.) Installed and Flush Mounted Electrical Distribu on Load Center P/N# QO112M100 for Electrical Distribu on, with Front Cover P/N# QO12UF, and Ground Bar Kit P/N# PK9GTA, as shown in drawing.
2.) Installed and Mounted Single receptacle for Hea ng and Cooling Unit 15A, 125V Nema 5- 15R, P/N# 501-S, as shown in drawing.
3.) Permanently Installed and Mounted Hea ng and Cooling Unit to Conex, Fredrich P/N #KEQ08A11, to maintain Wind and water ght condi ons of Conex Box.
4.) Frame Back Wall using 2” X 4” Douglas Fir, Insulate Back Wall using R13 3 ½” X 15” Ba Insula on.
5.) ½” Plywood to Cover Framing and Insula on.
6.) Paint Interior Back Wall Semi-Gloss White.
Interior Right and Le Side Wall
1.) Cabinets as shown in drawing.
2.) Bo om Cabinet ST 340 Salient Specifica ons are as Follows:
- The Bo om Cabinet will be of the Following Dimensions:
-59” In Height, 30” in Width, and 27.5” in Depth with 3 EA Shelves, Capacity of 400 LBS Per Shelf, Each Shelf will have a Ba en to secure items on shelf. Will have a Pan Bo om at the base of cabinet. Will have a top stack feature. Cabinets will not have no feet, and no lock and all ST 340 Cabinets will have a Roll Out Tray at Bo om of Cabinet.
3.) Top Cabinets ST 155 Salient Specifica ons are as Follows:
- 30"H x 30"W x 27.75"D. Cabinets will have 1 Shelf and Ba en to Secure Items on Shelf.
Cabinet will have a pan bo om.
4.) All Cabinets will be RED in Color including the shelves and Ba ens.
5.) Cabinets will be bolted together side to side where applicable using Pre Drilled Holes inside of Cabinets.
6.) Cabinets will be a ached to the Conex via slo ed angle or unistrut, for maximum safety and rigidity.
7.) Use ½” Plywood to Cover Framing and Insula on.
8.) Paint Interior Right and Le Wall SemiGloss White.
9.) Bo om and Top Cabinets
10.) Each shelf will have a ba en to secure items stored in cabinet. It will have No Feet and No locks.
1.) All Cabinets, Shelves, Ba ens, Red in Color.
2.) The Work Bench will consist of the following specifica ons: Uline Workbench H-11258-MAP with 1 ¾”, Maple Top Cabinets will be Black in Color.
3.) Uline Workbench H-11258-MAP with 1 ¾” Maple Top as shown in Drawing.
4.) Cabinets will be bolted together side to side where applicable using Pre Drilled Holes inside of Cabinets.
5.) Cabinets will be a ached to the Conex via slo ed angle or unistrut, for maximum safety and rigidity.
6.) Frame Le Wall with 2” X 4” Douglas Fir, Insulate Right and Le Wall using R13 3 ½” X 15” Ba Insula on.
7.) Cover Framing and Insula on using 1/2” Plywood
8.) (2) EA 4 Outlet Receptacles and associated conduit as shown in drawing.
10.) Paint Interior Le and Right Wall Semi-Gloss White.
11.) Light Switch on Le Wall and Right Wall as shown in drawing.
Interior Ceiling
1.) (2) EA Overhead LED Ligh ng Fixtures in Ceiling.
2.) Frame Interior Ceiling with 2” X 4” Douglas Fir, Insulate Ceiling using R-13 3 ½” X 15” Ba Insula on
3.) Cover Framing and Insula on using ½” Plywood.
4.) Paint Interior Ceiling Semi-Gloss White.
Exterior Back Wall
1.) General Safety Switch, recessed mounted P/N# DG322NRB, on exterior back wall of Conex and allow enough space to safely operate switch and connect electrical leads to Switch, all welds and penetra ons into Conex will be verified that they maintain Wind and Water ght Condi ons of Conex Box.
2.) Permanently Mounted Hea ng and Cooling Unit to Conex, Fredrich P/N # KEQ08A11, to maintain Wind and Water ght condi ons of Conex Box.
NRTL Cer fica on
The equipment and its component parts shall be in compliance with applicable Code of Federal Regula ons (CFR) Title 29, Part 1910. By defini on, any equipment will be deemed acceptable and approved by TRF, Bangor, if it meets specific Occupa onal Safety and Health Administra on (OSHA) condi ons outlined in CFR Title 29, Part 1910; Subparts "O" and "S". Specifically, equipment will be "Accepted" by TRF, Bangor, if it has been inspected and found by a Na onally Recognized Tes ng Laboratory (NRTL) to conform to specified plans or procedures of applicable codes. The equipment (as a whole system) shall be Na onally Recognized Tes ng Laboratory (NRTL) inspected and cer fied (by an OSHA authorized third party). Two (2) “hard” copies of the NRTL cer fica on report shall be provided. If the equipment type/model has already been NRTL inspected and cer fied, a cer fica on report (two (2) ”hard” copies) or documenta on mounted on the equipment, (which acknowledges it is NRTL cer fied), shall be provided.
File details come from the government source that posted it. Updated .