Salient Characteristics
For a Hose Proof Tester
Project #906‐310
Hose Proof Tester with Modifications:
TEST ENCLOSURE: 72” L x 36” W x 22” H test bed 304 SS. Top shield will have a tubular frame with clear
Lexan viewing window, front lowering gate with pneumatic actuators, see attached drawing.
TEST CONSOLE: 14 gauge sheet metal, powder coated with front access door, rear access panels, aluminum gauge panels, powder coated.
GAUGES: Test Gauges: 4” dial, digital, bottom mount, with quick disconnect, 0‐10,000 PSI Crystal XP2i
Gauge (2 each), 0‐10,000 PSI with QDC, additel 4” dial, digital gauge GP25K with ¼” HP fitting (2ea).
ANALOG Gauges: 2 ½” & 4” dial panel mounted for air & water supply and pump discharge gauges.
VALVES: Panel mounted valves for supply shut off, drain valve and vent valve. 2 separate circuits, 0‐10K clean circuit, and 0‐20K standard high pressure circuit.
RELIEF VALVES: Circle Seal 5300 Series (customer‐supplied).
SAFETY FEATURES: Lexan enclosure with automatic test drain if the enclosure is opened, under pressure.
AIR FLUSH: Capability to air flush hoses with air after test is completed, includes shut off valve, and vent valve and vent port.
HYDROSTATIC PUMPS: Sprague air driven piston pumps, 100:1 ratio (10K PSI) and 200:1 ratio (20K PSI).
FILTERS: Norman 30K Series inline filters for the low pressure circuit on the inlet and outlet side of the clean system.
HIGH PRESSURE FITTINGS: 30,000 PSI stainless steel, coned and threaded fittings. Hoke Gyrolok compression type for 10,000 PSI circuit.
AUTOMATIC DRAIN VALVE: ¼” normal open valve, air to close, 30,000 PSI, opens when shield is opened under pressure, 0‐10,000 for the clean side.
DOCUMENTATION: Two (2) copies of Technical manuals, with schematic diagrams, parts break down list, operating procedures.
WARRANTY: One (1) year standard warranty