SALIENT CHARACTERISTICS.pdf
PDF 379 KB Posted
- Attached to
- HYDROLIC TRAINER Federal contract opportunity
- Solicitation number
- SPMYM223Q1680
About this file
This document outlines the minimum specifications for a dual sided hydraulic training simulator. The simulator must have 115 volt touchscreen control, component fault simulation and troubleshooting capabilities, and the ability to apply test loading to actuators. It must include an axial piston-type variable volume pump, industrial and mobile-type directional and pressure control valves, adjustable flow control valves, linear and rotary actuators, and diagnostic devices including gauges and meters. Fluid conductors and fittings are also specified. The unit must meet NRTL safety standards for certification and ITPR requirements.
The related federal contract opportunity is solicitation number SPMYM223Q1680 for a hydraulic trainer issued by the Defense Logistics Agency Land and Maritime. The solicitation seeks products that meet the minimum specifications provided in the technical document.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| 23Q1680 HYDROLIC TRAINER.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Double Station Hydraulic Training Simulator With Electronic Troubleshooting Part No: MF102D-H-TSE or Equal
JML #:3143-3975 - 3982
Minimum Specifications.
Dual sided 115 Volt training simulator with touchscreen control
Component fault simulation and troubleshooting capability
Capability to apply test loading to actuators
Scalable with additional training modules
Safety lockout system to de-energize simulator and relieve stored energy hazards
HPU: Axial piston-type, variable volume, pressure-compensated pump
Fluid filtration system
Directional control valves:
Three industrial-type (parallel)
One industrial-type (series)
One mobile-type (cylinder spool center)
One mobile-type (motor spool center)
Proportional
Adjustable pressure control valves:
Pilot Operated and Direct Acting pressure relief valves
Pressure Reducing, Counterbalance w/internal bypass check, Sequencing
Check Valve, Pilot Operated Check Valve
Adjustable flow control valves:
Needle Valve
Pressure Compensating w/internal bypass check
Actuators:
2ea Linear Double Acting Cylinders
1ea Rotary Bi-Directional
Diagnostic devices:
3ea Bourdon Tube Gauges
2ea Flow Meter 0-2gpm
Fluid conductors
8ea - 60” length
16ea - 42” length
12ea - 28” length
16ea Tee Fittings
SAE 100-R1 hosing equipped with flat-face type quick disconnect end connections
Standards.
Unit must meet safety standards for NRTL certification and have such certification affixed.
Unit must meet requirements of the ITPR obtained through approval of C/109.
File details come from the government source that posted it. Updated .