Ultrasonic cleaning tank salient characteristics 12100155-1200162

-Tank system must be made with all stainless steel construction

-Tank system must be a multiple frequency ultrasonic system

-Tank system must be a two tank system. One tank for cleaning and one tank for heated rinsing

-The tanks size must be 36” x 36” x 36” deep

-The cleaning tank must have a hinged cover with a minimum 150 lb.

load capacity when in the open position

-The cleaning tank must include a wire-cloth basket that fits inside tank, to hold parts, 150 lb. capacity minimum

-Tank system must include a draining system with an air-powered pump

-Tanks must be equipped with 40Khz and 80Khz ultrasonic transducers mounted into 4 total transducer packs, packs dimensions: 34” x 8” x 3.25” tall and mounted to bottom of tank

-The transducers must have a coating for erosion control

-The transducers must be powered by 2 industrial grade, ultrasonic generators with 40kHz/80kHz power supply

-The cleaning tank must have a total ultrasonic power of: 9600 peak watts, 6790 watts RMS

-The cleaning tank must include a rest platform to hold parts baskets 300 lb. capacity minimum, 500 lb. maximum

-The tanks must have a tubular shaped support frame

-Support frame must have dimensions: 72” x 48” x 48” high

-Tank must include a 1/2HP flow pump in the filtration system

-Tanks must have a 7500 watt immersion heater with digital controls

-Controls must be housed in a NEMA 4X enclosure

-Tank controls must include a timer for cleaning cycles, an emergency-stop button, a power button with light indicator, cleaning cycle options button, generator indicator light

-Tank system must have a 208/220/240 VAC, 3phase power supply

-Tank must have a 185 degree max cleaning cycle

-Tank system must be inspected in the factory and given a UL listing by the MET laboratories

-Ultrasonic cleaning tank must be approved by PSNS C/106 before contract is awarded