Ultrasonic cleaning tank salient characteristics 12100155-1200162
-Tank system must be made with all stainless steel construction
-Tank system must be a multiple frequency ultrasonic system
-Tank system must be a two tank system. One tank for cleaning and one tank for heated rinsing
-The tanks size must be 36” x 36” x 36” deep
-The cleaning tank must have a hinged cover with a minimum 150 lb.
load capacity when in the open position
-The cleaning tank must include a wire-cloth basket that fits inside tank, to hold parts, 150 lb. capacity minimum
-Tank system must include a draining system with an air-powered pump
-Tanks must be equipped with 40Khz and 80Khz ultrasonic transducers mounted into 4 total transducer packs, packs dimensions: 34” x 8” x 3.25” tall and mounted to bottom of tank
-The transducers must have a coating for erosion control
-The transducers must be powered by 2 industrial grade, ultrasonic generators with 40kHz/80kHz power supply
-The cleaning tank must have a total ultrasonic power of: 9600 peak watts, 6790 watts RMS
-The cleaning tank must include a rest platform to hold parts baskets 300 lb. capacity minimum, 500 lb. maximum
-The tanks must have a tubular shaped support frame
-Support frame must have dimensions: 72” x 48” x 48” high
-Tank must include a 1/2HP flow pump in the filtration system
-Tanks must have a 7500 watt immersion heater with digital controls
-Controls must be housed in a NEMA 4X enclosure
-Tank controls must include a timer for cleaning cycles, an emergency-stop button, a power button with light indicator, cleaning cycle options button, generator indicator light
-Tank system must have a 208/220/240 VAC, 3phase power supply
-Tank must have a 185 degree max cleaning cycle
-Tank system must be inspected in the factory and given a UL listing by the MET laboratories
-Ultrasonic cleaning tank must be approved by PSNS C/106 before contract is awarded