Salient_Characteristics.docx
DOCX document 15 KB Posted
- Attached to
- TSC LWIR & CORONA CAMERA
- Solicitation number
- 140R8125Q0074
About this file
This is a salient characteristics document specifying requirements for a combined LWIR (Long-Wave Infrared) and Corona Camera system for the Bureau of Reclamation. The document outlines technical specifications for a high-performance camera system, with the preferred brand/model being the UViRCO CoroCAM CC 8HD High Performance Daylight Corona Imaging Camera or equivalent.
The required specifications include a combined LWIR and Solar Blind UV corona camera system capable of simultaneous detection of corona discharges and hot spots, featuring a 9Hz FLIR Radiometric LWIR camera module, synchronized zoom capabilities, and a Vox Microbolometer thermal detector with a 7.5-13.5 um spectral band and -40°C to 160°C temperature range. Additional requirements include 1920x1080 pixel resolution, 14 IR color palettes, integrated LED flashlight with laser pointer, and specific UV sensitivity metrics (SB 240-280 nm at 2.05x10-18 Watt/cm2). One unit is needed by March 31, 2025, to be delivered to the Denver Federal Center in Colorado, with a one-year warranty required.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| E-buy_Clauses_and_Provisions.pdf | ||
| Sol_140R8125Q0074.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
LWIR & Corona Camera Salient Characteristics/Specifications:
1. Combined LWIR and Solar Blind UV corona camera system. This allows simultaneous detection and location of corona discharges and hot spots.
2. High sensitivity solar blind UV detector.
3. 9Hz FLIR Radiometric LWIR camera module
4. Synchronized Smooth or Stepped Zoom of all 3 camera channels.
5. Integration & Noise Reduction control.
6. 14 IR color palettes with contrasting Isotherms.
7. Integrated high power LED flashlight with adjustable brightness levels & laser pointer.
8. UV sensitivity: SB (240 - 280 nm) 2.05x10-18 Watt/cm2; IEC 60270:2000: 3pC@20m (Korea Electrotechnology Research Institute) & 1.8pC@10m (Innogy) | NEMA107-1987: 13.16dBμV(RIV) @ 1MHZ @ 10m (Korea Electrotechnology Research Institute)
9. Thermal detector is a Vox Microbolometer with a spectral abnd of 7.5 to 13.5 um and a temperature range of -40 C to 160 C
10. Resolution 1920 x 1080 pixels.
11. One Year Warranty