Salient Characteristics CVD System.doc
DOC document 37 KB Posted
- Solicitation number
- W911QX26QA121
About this file
This is a Salient Characteristics Commercial Availability Certification document supporting a sole source procurement notice for a Chemical Vapor Deposition (CVD) System. The Department of the Army Materiel Command at Aberdeen Proving Ground has issued solicitation W911QX26QA121 for the procurement of one (1) CVD System, with the salient characteristics documented in this file certifying that all specified features are available in the commercial marketplace.
The required CVD System must include the following minimum specifications: a two-zone split furnace capable of reaching temperatures of at least 1,200 degrees Celsius; a 50-millimeter quartz tube with vacuum flanges; a four-channel gas control system with a Programmable Logic Controller (PLC) touch panel and PC operating software; and a heavy-duty double-stage rotary vane vacuum pump with exhaust filter capable of pumping 240 liters per minute. The system must be fully compatible with existing MTI Corporation hardware and software currently in the laboratory, including a furnace, gas flow controller, and vacuum pump. The certification indicates that a Technical Point of Contact or Contracting Officer's Representative will be designated to oversee the contractor's performance.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Adelphi Special Instructions and Information Full-Text Attachment.docx | DOCX document | |
| Combination Synopsis-Solicitation for Commercial Purchases.docx | DOCX document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Salient Characteristics
Commercial Availability Certification:
I have evaluated the commercial marketplace and determined that all of the salient characteristics documented below are available in products/services offered in the commercial marketplace.
Signature (typed name): ____TBD_____
Technical Point of Contact (TPOC) or Contracting Officer’s Representative (COR)
The Contractor shall provide one (1) Chemical Vapor Deposition System that has the following minimum specifications, or equivalent:
· Shall have a two (2)-zone split furnace capable of reaching temperatures of at least 1200 degrees Celsius (°C).
· Shall include a 50 millimeter (mm) quarts tube and vacuum flanges
· Shall include a four (4) channel gas control system with a Programmable Logic Controller (PLC) touch panel and PC operating software.
· Shall include a heavy-duty double stage rotary vane vacuum pump with exhaust filter capable of pumping 240 liters per minute (L/m).
· Shall be fully compatible with existing MTI Corporation hardware and software found in the laboratory including a furnace, gas flow controller, and vacuum pump.
Template last updated 07/28/2016