Salient Characteristics_26QA166_Signed.doc
DOC document 77 KB Posted
- Solicitation number
- W911QX26QA166
About this file
This is a Salient Characteristics Commercial Availability Certification document supporting a brand name sole source solicitation (W911QX26QA166) issued by the Department of the Army Materiel Command, Army Contracting Command Aberdeen Proving Ground. The U.S. Army Combat Capabilities Development Command (DEVCOM) Army Research Laboratory (ARL), specifically the Power and Energy Sciences Division, requires one benchtop environmental battery test chamber for battery and cell testing purposes. The certifying official, Marshall A. Schroeder, Ph.D., has confirmed that all specified characteristics are commercially available.
The required system must include integrated cell test fixtures capable of simultaneously testing a minimum of 48 cells, comprising 12 holders for 18650 cells, 12 holders for 21700 cells, and 24 holders for pouch cells. The chamber must provide temperature control from -70°C to 180°C with external programmability compatible with a MACCOR Battery cycler. Additional technical requirements include safety features meeting European Council for Automotive R&D (EUCAR) Hazard Level 7 for cell failure scenarios, thermocouple feedthroughs, wiring capacity for 25 amperes or greater per channel across a minimum of 48 test channels, braided-pair wiring for interface with a Novonix Ultra-High Precision Coulometer for low-noise measurements, and internal chamber dimensions of at least 24 inches width by 24 inches depth by 24 inches height.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Solicitation_26QA166_QA.docx | DOCX document | |
| Adelphi Special Instructions and Information Full-Text Attachment_26QA166.doc | DOC document | |
| Combination Synopsis-Solicitation for Commercial Purchases (Under SAT)_26QA166_Signed.docx | DOCX document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Salient Characteristics
Commercial Availability Certification:
I have evaluated the commercial marketplace and determined that all of the salient characteristics documented below are available in products/services offered in the commercial marketplace.
Signature (typed name): _Marshall A. Schroeder, Ph.D. ___
Technical Point of Contact (TPOC) or Contracting Officer’s Representative (COR)
The Power and Energy Sciences Division at the United States Army Combat Capabilities Development Command (DEVCOM) Army Research Laboratory (ARL) requires one (1) benchtop environmental battery test chamber for battery/cell testing with the following salient characteristics:
-The system must have integrated cell test fixtures for testing a minimum of 48 cells at a time, including at least 12 x 18650 cell holders, 12 x 21700 cell holders, and 24 x pouch cells holders.
-The system must have temperature control range meeting or exceeding -70°C to 180°C and the temperature must be externally programmable with a MACCOR Battery cycler
-The system must have safety features covering at least a European Council for Automotive R&D (EUCAR) Hazard Level 7 Cell failure (explosion/venting)
-The chamber must be equipped with feedthroughs for thermocouple wiring
-The system must be wired for currents up to 25 amps (A) or more per channel, with a minimum of 48 cell test channels
-The system must have braided-pair wiring to interface with a Novonix Ultra-High Precision Coulometer for low noise measurements -The internal chamber dimensions must be a minimum of 24” (W) x 24” (D) x 24” (H)
Contracting Officer:
Template last updated 01/8/2019