S02 VAMC 5YrInsp-1st Floor.pdf
PDF 178 KB Posted
- Attached to
- Minneapolis VAMC Sprinkler & Fire Pump Test Solicitation Federal contract opportunity
- Solicitation number
- 36C26324Q1043
About this file
This document is a 5-Year Inspection and Internal Pipe Assessment Form for the Minneapolis VA Medical Center (VAMC). The form is used to evaluate the condition and operation of various fire protection system components, including check valves, alarm valves, strainers, filters, sprinkler heads, and pressure regulating devices. The purpose is to provide reasonable assurance that corrosion and obstruction issues within the fire protection system(s) are identified by opening a flushing connection and inspecting for the presence of foreign material.
The related federal contract opportunity is a solicitation (Solicitation Number: 36C26324Q1043) issued by the Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 23 for Minneapolis VAMC Sprinkler & Fire Pump Test services. The solicitation document contains the description of the requirement and instructions for responding to the solicitation.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| S06 Offer Deadline Extension 36C26324Q1043 0001.docx | DOCX document | |
| S06 Offer Deadline Extension 36C26324Q1043 0001.docx | DOCX document | |
| S02 DOL WD 2015 4945 R24 04262024 Minneapolis MN.txt | TXT text file | |
| S02 Sprinkler and Fire Pump Test Mpls VAMC 36C26324Q1043.docx | DOCX document | |
| S02 Sprinkler Zone - 4th Floor.pdf | ||
| S02 Sprinkler Zone - 2nd Floor.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
5-Year Inspection and Internal Pipe Assessment Form
Tag Minneapolis Inspection Frequency: Fifth Year Property Being Evaluated:
VAMC (Health Care) Owner:
Owner's Phone Number:
Property Address:
1 VETERANS DR, MINNEAPOLIS, MN, 55417-2309
1. General A. (To be filled out by the Owner or Owner's Representative) Has the Owners section been answered on another inspection report that will be submitted with this inspection report? Yes No
2. Five-Year Inspection Items
1. Check valve(s) internally inspected and all parts appear to operate properly, move freely, and are in good condition? Yes No N/A
2. Alarm valve(s) and their associated strainers and restricted orifices passed internal inspection? Yes No N/A
3. Strainers, filters, restricted orifices, and diaphragm chambers on Dry, Pre-Action, and/or Deluge valves passed internal inspection? Yes No N/A
4. Have known sprinkler heads exposed to harsh conditions (ie. Corrosive atmospheres, extreme temperatures, etc.) been tested/replaced? Yes No N/A
5. Have gauge(s) been replaced and dated? Yes No N/A
6. Performed pressure regulating device full flow test? Yes No N/A
7. Performed standpipe test? Yes No
3. Five-Year Assessment of Internal Condition of Piping The purpose of the assessment of the internal condition of piping is to provide a reasonable assurance that corrosion and obstruction issues within the fire protection system(s) are identified by opening a flushing connection at the end of one main and removing the end fitting, piece of branch line, or a sprinkler for the purpose of inspecting for the presence of foreign organic and inorganic material. It is not the intent to verify that every piece of pipe in the system is free from corrosion and obstructions.