S02 - SOLICITATION ATTACHMENT - D.15 PRE-TREATMENT AND TRANSPORTATION OF SOILED CRITICAL AND SEMI-CRITICAL REUSEABLE MEDICAL EQUIPMENT.pdf

PDF 502 KB Posted

Attached to
Q201--ST. LAWRENCE COUNTY SOLICITATION (VA-20-00031053)
Solicitation number
36C24220R0146
Issued by

View the file

Other files

File Type Posted
36C24220R0146 0001.docx DOCX document
S02 - SOLICITATION ATTACHMENT - D.28 Home Telehealth Operations Manual.pdf PDF
S02 - SOLICITATION ATTACHMENT - D.22 Medication Reconciliation MCPM 11-146.pdf PDF
S02 - SOLICITATION ATTACHMENT - D.14 EOC ASSESSMENT AND COMPLIANCE ROUNDING PROCESS GUIDE.pdf PDF
S02 - SOLICITATION ATTACHMENT - D.17 24VA19 Patient Medical Records-VA.pdf PDF
S02 - SOLICITATION ATTACHMENT - D.10 Suicider risk assessment, intervention, and documentation.pdf PDF
S02 - SOLICITATION ATTACHMENT - D.19 20-03 Ordering Laboratory Tests Phlebotomy and Specimen Collection.pdf PDF
S02 - SOLICITATION ATTACHMENT - D.16 PRE-TREATMENT AND TRANSPORTATION OF SOILED CRITICAL AND SEMI-CRITICAL REUSEABLE MEDICAL EQUIPMENT - UPDATED.pdf PDF
S02 - SOLICITATION ATTACHMENT - D.11 VHA DIRECTIVE 1003.4, VHA PATIENT ADVOCACY.pdf PDF
S02 - SOLICITATION ATTACHMENT - D.20 Ancillary Laboratory Testing Guidelines.pdf PDF
S02 - SOLICITATION ATTACHMENT - D.4 ORGANIZATIONAL CONFLICTS OF INTEREST.docx DOCX document
S02 - SOLICITATION ATTACHMENT - D.29 VETERANS BY ZIP CODE.pdf PDF
S02 - SOLICITATION ATTACHMENT - D.30 - DAVIS BACON - ST. LAWRENCE.pdf PDF
S02 - SOLICITATION ATTACHMENT - D.25 IMAGING - REPORT OF IMAGING TEST RESULTS.pdf PDF
S02 - SOLICITATION ATTACHMENT - D.23 Communicating Test Results to Providers and Patients. June2016.pdf PDF
S02 - SOLICITATION ATTACHMENT - D.24 LABORATORY SERVICES MANUAL.pdf PDF
S02 - SOLICITATION ATTACHMENT - D.9 Pathology and laboratory medicine supply list.pdf PDF
S02 - SOLICITATION ATTACHMENT - D.18 RIGHTS AND RESPONSIBILITIES OF VA PATIENTS AND RESIDENTS OF COMMUNITY LIVING CENTERS (CLC).pdf PDF
S02 - SOLICITATION ATTACHMENT - D31 BVAC No Show and Cancel by Patient.pdf PDF
36C24220R0146_3.docx DOCX document
S02 - SOLICITATION ATTACHMENT - D.26 VHA Directive 1108.16, Anticoagulation Therapy Management.pdf PDF
S02 - SOLICITATION ATTACHMENT - D.12 Tracking and care coordination.pdf PDF
S02 - SOLICITATION ATTACHMENT - D.8 RULES OF BEHAVIOR.pdf PDF
S02 - SOLICITATION ATTACHMENT - D.7 TELEHEALTH OPERATIONS MANUAL - CLINIC BASED.pdf PDF
S02 - SOLICITATION ATTACHMENT - D.13 Current Performance Measures and Method of Extractions.pdf PDF
S02 - SOLICITATION ATTACHMENT - D.6 - Wage Determination No. 2015-4169 - Clinton - Essex - Franklin - Lewis and st. Lawrence.pdf PDF
D.32 - Physician Qualification Standard.pdf PDF
D.33 VETERANS RESIDING IN ST. LAWRENCE COUNTY BY ZIP CODE.pdf PDF
S02 - SOLICITATION ATTACHMENT - D.27 - PATIENT DEMOGRAPHICS.pdf PDF
S02 - SOLICITATION ATTACHMENT - D.34 MEDICATIONS.pdf PDF
S02 - SOLICITATION ATTACHMENT - D.21 ANTICOAGULATON CLINIC POLICIES AND PROCEDURES MCPM 11-06.pdf PDF
Show all 31

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Department of

Veterans Affairs

Date: f EB 1 1 2016

Memorandum

From: Assistant Deputy Under Secretary for Health Operations and Management (1 ON) subj: Pre-treatment and Transportation of Soiled Critical and Semi-Critical Reusable Medical Equipment (RME) ro: VISN Directors, VISN CMOs, VISN QMOs, VISN Nurse Executives, VISN Sterile

Processing Boards

1. This memorandum is to improve current processes for pre-t transportation of soiled RME from the point of use to a econtamination area in accordance with professional practice standards.

2. Pre-Treatment:

a. Responsibility of end user

b. Manufacturer's Instructions for Use (IFUs) must be followed

c. Removal of all gross debris must occur prior to application of enzymatic solution

d. Use of Food and Drug Administration (FDA) approved pretreatment enzymatic solution (Note: If IFUs delineate specific validated solution, said solution must be used)

e. Thoroughly spray enzymatic solution directly onto instruments to be cleaned allowing for each instrument to remain covered to dissolve bioburden.

f. Application of enzymatic solution is to be done immediately following

RME use. This can occur at point of care or within soiled utility room.

3. Transport of RME from point of care to soiled utility/appropriate holding area:

a. Properly labeled medical grade puncture resistant biohazard rigid container or an enclosed cart is to be used to transport all RME

b. Two methods:

i. Exchange transport container - the container with the soiled RME is placed in the utility room and a clean container (which has been intermediate level disinfected between uses) acquired from clean storage is taken back to the point of use.

ii. Point of use transport container - the container with soiled RME at point of care is transported to soiled utility room where end user will don appropriate PPE to transfer soiled RME to designated collection container that is a properly labeled medical grade puncture resistant biohazard rigid container. The point of care

D.15 PRE-TREATMENT AND TRANSPORTATION OF SOILED CRITICAL AND SEMI-

CRITICAL REUSEABLE MEDICAL EQUIPMENT