The document is a Utility Relocation Plan (drawing C-1.2) for a construction project, detailing the relocation and modification of existing utilities around a proposed and existing building. The plan includes specific notes for the contractor regarding utility management, such as:

  1. Relocating existing utilities like power poles, sump pumps, and underground conduits
  2. Providing irrigation in planter areas
  3. Removing existing power poles and installing new concrete pedestals
  4. Installing 2-6" PVC conduit pipes
  5. Ensuring all utilities are protected and relocated to accommodate the new building footprint

The drawing is scaled at 1"=20'-0" and provides a comprehensive layout showing the precise positioning of existing structures, proposed buildings, utility infrastructure, and site boundaries, with color-coded annotations indicating specific relocation and modification requirements.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

U

TI

LI

TY

R

EL

O C

AT

IO

N P

LA

N

C-1.2

AutoCAD SHX Text

DEBRIS

AutoCAD SHX Text

TC 30.70

AutoCAD SHX Text

INV. 28.35

AutoCAD SHX Text

TC EL. 30.20

AutoCAD SHX Text

INV. EL. 27.09

AutoCAD SHX Text 15" RCP x 45'

AutoCAD SHX Text @ 0.0020'/, AutoCAD SHX Text

FLOW

AutoCAD SHX Text

INV. EL. 27.00

AutoCAD SHX Text 15" RCP x 65'

AutoCAD SHX Text @ 0.0020'/, AutoCAD SHX Text 15" RCP x 65'

AutoCAD SHX Text @ 0.0020'/, AutoCAD SHX Text

TC 29.70

AutoCAD SHX Text

INV. 24.39

AutoCAD SHX Text

TC 29.70

AutoCAD SHX Text

INV. 24.26

AutoCAD SHX Text

TC 29.70

AutoCAD SHX Text

INV. 24.39

AutoCAD SHX Text 15" RCP x 130'

AutoCAD SHX Text @ 0.0020'/, AutoCAD SHX Text

INV. EL. 24.00

AutoCAD SHX Text S

AutoCAD SHX Text

SEWER MANHOLE

AutoCAD SHX Text

(INV. 27.88)

AutoCAD SHX Text 6" S

AutoCAD SHX Text 6" S

AutoCAD SHX Text

STUBOUT

AutoCAD SHX Text

STUBOUT

AutoCAD SHX Text 8" W

AutoCAD SHX Text W

AutoCAD SHX Text W

AutoCAD SHX Text

WM

AutoCAD SHX Text

WM

AutoCAD SHX Text

APPARENT P

AutoCAD SHX Text L

AutoCAD SHX Text

2" COPPER

AutoCAD SHX Text

TO CONTROLLERS

AutoCAD SHX Text

EXISTING PLANTER

AutoCAD SHX Text

AutoCAD SHX Text

EXISTING BUILDING

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

EXISTING FIRE HYDRANT

AutoCAD SHX Text

WM

AutoCAD SHX Text

WM

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

REMOVE EXISTING TIMBER LIGHT POLE (TYP.)

AutoCAD SHX Text

PROPOSED BUILDING

AutoCAD SHX Text

PROPOSED BUILDING

AutoCAD SHX Text

AutoCAD SHX Text

PLUG

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

PROVIDE IRRIGATION IN PLANTER

AutoCAD SHX Text

AutoCAD SHX Text

2-6" PVC CONDUIT PIPE

AutoCAD SHX Text

%%UUTILITY RELOCATION PLAN

AutoCAD SHX Text

SCALE: 1"=20'-0"

AutoCAD SHX Text

AutoCAD SHX Text

RELOCATE EXISTING SUMP & ADD 8" SEWER LINE

AutoCAD SHX Text

AutoCAD SHX Text

RELOCATE EXISTING WATER METER & BACK FLOW PREVENTER

AutoCAD SHX Text

AutoCAD SHX Text

PLUG & ABANDONED EXISTING IRRIGATION LINE (ASSUMED FROM ORIGINAL CONTRACT DWGS.)

AutoCAD SHX Text

AutoCAD SHX Text INSTALL NEW TIMBER POLE IN 3' x 3' HIGH CONCRETE PEDESTAL

AutoCAD SHX Text

NOTES:

AutoCAD SHX Text

AutoCAD SHX Text RELOCATE EXISTING TIMBER ELECTRIC POLE (REF. DWG. NO. E-1.1) RELOCATE UNDERGROUND CONDUITS.

AutoCAD SHX Text

AutoCAD SHX Text

RELOCATE EXISTING SUMP PUMP

AutoCAD SHX Text NOTES: CONTRACTOR SHALL LOCATE AND PROTECT ALL EXISTING UTILITIES BEFORE BEGINNING EXCAVATIONS. CONTRACTOR SHALL RELOCATE ALL UTILITIES ATTACHED TO SIDE WALL AND EDGES OF EXISTING BUILDING IN-WAY OF NEW BUILDINGS.

AutoCAD SHX Text 1.)

AutoCAD SHX Text 2.)

Sheets and Views
NEW-UTILITY

File details come from the government source that posted it. Updated .