S02 LuxOR Revalia Brochure.pdf

PDF 1 MB Posted

Attached to
6540--Alcon LX3 Led Luxor Revalia Ophthalmic Microscopes Brand Name.
Solicitation number
36C25623Q0799
Issued by

View the file

Other files

File Type Posted
S02 LuxOR Revalia Spec Sheet.pdf PDF
36C25623Q0799_1.docx DOCX document
36C25623Q0799-Alcon Surgical Opthalmic Microscopes-Combine.pdf PDF
S02 Brand Name Justification.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Designed for you to see more detail than ever before, the LuxOR Revalia™

Ophthalmic Microscope delivers personalized illumination for confident visualization.

See your procedures in a new light The LuxOR Revalia™ Ophthalmic Microscope advances visualization with personalized illumination, giving you confidence throughout the procedure.

• Personalized illumination that puts you in control of your surgical view

• Advanced visualization with 6x larger, more stable red reflex and enhanced depth of field1-3

• Designed to exceed your expectations with a streamlined workflow

• Confidence in all ophthalmic procedures, including cataract and vitreoretinal surgery

• Complete surgical integration with advanced Alcon technologies

Personalized illumination Customized LED illumination:

• Offers enhanced optical clarity for complete views throughout the procedure

• Provides longer life and reliability so you can depend on uniform illumination*

• Independently adjust the blend of coaxial and oblique light sources to optimize your view throughout every stage of surgery

Three LED Module Options With Different Color Temperatures

Cool White Mixed WhiteWarm White

*Compared to halogen illumination.

Advanced visualization The Alcon proprietary illumination technology provides surgeon-preferred red reflex and enhanced depth of field to ensure crisp, confident visualization throughout every procedure.1

6x larger, more stable red reflex3:

• Expands the illumination field so you can reveal more at every stage of surgery

Enhanced depth of field3:

• Enables fewer focus adjustments during both anterior and posterior surgical procedures

• Supports excellent detail recognition and contrast for increased confidence

Modern on-axis illumination technology

Red ReflexZone 6x-Larger Red ReflexZone

The Alcon proprietary illumination technology

Advanced visualization

See more planes at once so you don’t miss a detail

Confidence in all ophthalmic procedures Whether you are performing procedures in the anterior or posterior segment, the Alcon proprietary illumination technology can help you feel confident at every step.

Anterior segment procedures

6x-larger red reflex zone with greater stability3:

• Expands visibility for a clear view of the anterior segment

CENTURION® Vision System integration*:

• Displays overlays via the workstation external display

Integration with Alcon advanced technology diagnostics†:

• Provides real-time surgical guidance through your ocular

• Records all your cases without the need for external monitors or additional equipment*

*Requires video package.

†Requires VERION® DML, the ORA SYSTEM® with VerifEye®+ or the ORA SYSTEM® with VerifEye® Lynk.

Confidence in all ophthalmic procedures

Posterior segment procedures

Wide-field viewing system compatibility:

• Can be utilized to customize your procedure for supported visualization of the retina

• Motorized BIOM*,† option controlled via the foot pedal

Proprietary AMP technology:

• Removes the beam splitter out of your optical path, providing 100% retroillumination for increased confidence in vitreoretinal surgery

*When supplied with integrated HD video system and OCULUS BIOM†.

†Trademarks are the property of their respective owners.

Integration with the

NGENUITY® 3D Visualization System

Digital visualization can be added to any LuxOR® Microscope:

8065753091 NGENUITY® 3D Visualization System

*Compared to analog microscopes. Specified performance was achieved at maximum system magnification with an aperture setting of 30% open and viewing distance of 1.2 m.

Amplify personalized illumination and digital visualization

• Discover superior visualization of structures and pathologies

• Experience up to 48% greater magnification*,4

• Achieve up to 42% finer depth resolution*,4

Prepare to reveal it all with the LuxOR Revalia™ Microscope

Discover how personalized LED illumination technology by Alcon can help you see more and operate with confidence.

8065753150 LuxOR Revalia™ Microscope 175/200

8065753151 LuxOR Revalia™ 175 with Q-VUE® assistant scope

8065753152 LuxOR Revalia™ 200 with Q-VUE® assistant scope

8065754031 LuxOR® LED Module 3 pack

8065753085 LED Module CoolWht

8065753086 LED Module MixedWht

8065753084 LED Module WarmWht

Important Product Information LuxOR Revalia™ Ophthalmic Microscope Important Product Information As with all ophthalmic microscopes, exposure during aphakia should be limited to reduce the risk of damage. During aphakia, limit exposure to red reflex light to no more than 7 minutes.

CENTURION® Vision System Important Product Information CAUTION: Federal (USA) law restricts this device to sale by, or on the order of, a physician.

As part of a properly maintained surgical environment, it is recommended that a backup IOL injector be made available in the event the AutoSert® IOL Injector Handpiece does not perform as expected.

INDICATION: The CENTURION® Vision system is indicated for emulsification, separation, irrigation, and aspiration of cataracts, residual cortical material and lens epithelial cells, vitreous aspiration and cutting associated with anterior vitrectomy, bipolar coagulation, and intraocular lens injection. The AutoSert® IOL Injector Handpiece is intended to deliver qualified AcrySof® intraocular lenses into the eye following cataract removal.

The AutoSert® IOL Injector Handpiece achieves the functionality of injection of intraocular lenses. The AutoSert® IOL Injector Handpiece is indicated for use with the AcrySof® lenses SN6OWF, SN6AD1, SN6AT3 through SN6AT9, as well as approved AcrySof® lenses that are specifically indicated for use with this inserter, as indicated in the approved labeling of those lenses.

WARNINGS: Appropriate use of CENTURION® Vision System parameters and accessories is important for successful procedures. Use of low vacuum limits, low flow rates, low bottle heights, high power settings, extended power usage, power usage during occlusion conditions (beeping tones), failure to sufficiently aspirate viscoelastic prior to using power, excessively tight incisions, and combinations of the above actions may result in significant temperature increases at incision site and inside the eye, and lead to severe thermal eye tissue damage.

Good clinical practice dictates the testing for adequate irrigation and aspiration flow prior to entering the eye. Ensure that tubings are not occluded or pinched during any phase of operation.

The consumables used in conjunction with ALCON® instrument products constitute a complete surgical system. Use of consumables and handpieces other than those manufactured by Alcon may affect system performance and create potential hazards.

AES/COMPLICATIONS: Inadvertent actuation of Prime or Tune while a handpiece is in the eye can create a hazardous condition that may result in patient injury. During any ultrasonic procedure, metal particles may result from inadvertent touching of the ultrasonic tip with a second instrument. Another potential source of metal particles resulting from any ultrasonic handpiece may be the result of ultrasonic energy causing micro abrasion of the ultrasonic tip.

ATTENTION: Refer to the Directions for Use for the accessories/consumables and Operator’s Manual for a complete listing of indications, warnings, cautions and notes.

NGENUITY® 3D Visualization System Important Product Information CAUTION: Federal (USA) law restricts this device to sale by, or on the order of, a physician.

INDICATION: The NGENUITY® 3D Visualization System consists of a 3D stereoscopic, high-definition digital video camera and workstation to provide magnified stereoscopic images of objects during micro-surgery. It acts as an adjunct to the surgical microscope during surgery displaying real-time images or images from recordings.

WARNINGS: The system is not suitable for use in the presence of flammable anesthetics mixture with air or oxygen. There are no known contraindications for use of this device.

PRECAUTIONS: Do not touch any system component and the patient at the same time during a procedure to prevent electric shock. When operating in 3D, to ensure optimal image quality, use only approved passive-polarized glasses. Use of polarized prescription glasses will cause the 3D effect to be distorted. In case of emergency, keep the microscope oculars and mounting accessories in the cart top drawer. If there are any concerns regarding the continued safe use of the NGENUITY® 3D Visualization System, consider returning to using the microscope oculars.

ATTENTION: Refer to the User Manual for a complete list of appropriate uses, warnings and precautions.

1.Cionni RJ, Pei R, Dimalanta R, et al. Evaluating red reflex and surgeon preference between nearly-collimated and focused beam microscope illumination systems.

Transl Vis Sci Technol. 2015;4(4):7.

2. Schwiegerling J, Dimalanta R. Depth of focus measurements of ophthalmic surgical microscopes. Poster presented at: The Association for Research in Vision and Ophthalmology; May 1-5, 2016; Seattle, WA.

3. Alcon Data on File.

4. Alcon Data on File.

References

© 2021 Alcon Inc. 7/21 US-LUX-2100009

Slide Number 1
See your procedures in a new light
Personalized illumination
Advanced visualization
Slide Number 5
Confidence in all ophthalmic procedures
Confidence in all ophthalmic procedures
NGENUITY® 3D Visualization System
Prepare to reveal it all with the LuxOR Revalia™ Microscope
Important Product Information
References

File details come from the government source that posted it. Updated .