REVISIONS
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
STAMPCONSULTANT
321 4 5 6 7 8 9 10
672-23-104
LAD NO.
Office of Construction and Facilities Management
CD (100%CD) FINAL BID DOCUMENTS – 03/14/2025
ARCHITECT/ENGINEER OF RECORD
A/E:
JUPITER
561-743-0165
ORLANDO
407-845-6630
WWW.RGDENGINEERS.COM
CERT OF AUTH 5454
121 S. ORANGE AVENUE, UNIT 1230N, ORLANDO, FL 32801
RGD PROJECT
#23-1050
8600 Indian Hills Dr Omaha, NE 68114 Tel 402.391.8111 Fax 402.391.8564
/1
/2
:3
:3
P
M
10 Calle Casia San Juan Puerto Rico 00921
COVER SHEET
GI001
Construct VA Bariatric Bathrooms at Community Center and South Bed Tower
003-10296-000
03/14/2025 RAD WMB
A u to d e s k D o c s /V
A C o n s tr u c t B a ri a tr ic B a th ro o m s a t C
L C
S
B T
R
V
A S
J B
A R
-A rc h it e c tu re .r v t
100% CD - FINAL BID
DOCUMENTS
Department of Veterans Affairs
Construct VA Bariatric Bathrooms at Community Center and South Bed Tower
VA CARIBBEAN HEALTHCARE SYSTEM
10 CALLE CASIA - ADM. BLDG. SUITE 4M440
SAN JUAN, PR 00921-3201
CD (100%CD) FINAL BID DOCUMENTS
LOCATION MAP APPLICABLE CRITERIA PROJECT INFORMATION
VA PROJECT NO. 36C24823R0029 NRM
DESIGN SERVICES PROJECT: 672-23-104
PROJECT LOCATION:
VA CARIBBEAN HEALTHCARE SYSTEM
10 CALLE CASIA - ADM. BLDG. SUITE #4M440
SAN JUAN, PR 00921-3201
ISSUING OFFICE:
DEPARTMENT OF VETERANS AFFAIRS
NETWORK CONTRACTING OFFICE 8 (NC0 8)
VA CARIBBEAN HEALTHCARE SYSTEM (ADMIN BLDG)
CDC GUIDANCE FOR ENVIRONMENTAL INFECTION CONTROL IN HEALTH-CARE
FACILITIES (PER HICPAC)
INTERNATIONAL BUILDING CODE - 2021 (IBC)
INTERNATIONAL FIRE CODE - 2021 (IFC)
INTERNATIONAL PLUMBING CODE - 2021 (IPC)
NFPA 13 – STANDARD FOR THE INSTALLATION OF SPRINKLER SYSTEMS - 2022
NFPA 70 – NATIONAL ELECTRICAL CODE (NEC) - 2023
NFPA 72 – NATIONAL FIRE ALARM AND SIGNALING CODE - 2022
NFPA 101 – LIFE SAFETY CODE - 2021
VHA BARIATRIC GUIDEBOOK - 2015
VA BARRIER FREE DESIGN STANDARD (ABAAS) - 2017
VA SAFETY PATIENT AND MOBILITY DESIGN CRITERIA - 2021
ALL APPLICABLE FEDERAL, EPA, OSHA, PROSHA, STATE, CITY AND LOCAL
CODES, REGULATIONS, ORDINANCES, PUBLICATIONS AND MANUALS.
NORTH
VA DESIGN MANUALS:
PG-18-1 MASTER SPECIFICATIONS
PG-18-3 DESIGN & CONSTRUCTION PROCEDURES
PG-18-4 STANDARD DETAILS AND CAD STANDARDS
PG-18-5 EQUIPMENT GUIDE LIST
PG-18-9 VA SPACE PLANNING CRITERIA
PG-18-10 DESIGN MANUALS (BY DISCIPLINE)
PG-18-12 DESIGN GUIDES
PG-18-13 TOPIC SPECIFIC STANDARDS AND CRITERIA
PG-18-14 ROOM FINISHES, DOOR AND HDWR SCHEDULE
CHANGE SUMMARY
PG-18-15 VOL C A/E SUBMISSIONS INSTRUCTIONS FOR
MINOR AND NRM CONSTRUCTION PROGRAM
PG-18-17 ENVIRONMENTAL GUIDANCE
H-18-8 VA SEISMIC DESIGN HANDBOOK
NO. DESCRIPTION DATE
SCALE:
B2
VIEW NAME
1/8" = 1'-0"
A4
EARTH
EARTH GRAVEL
CONCRETE
METALS
BRICK
CMU
TILE
STONE
WOOD
GYPSUM
GLASS
INSULATION
REGULAR
STEEL ALUMINUM
FACE COMMON
CMU
CERAMIC
MARBLE LIMESTONE
FINISH BLOCKING
PLASTER OR GWB
LARGE SCALE SMALL SCALE
BATT OR
LOOSE
RIGID
SURFACE
DETAIL TITLE
BUILDING SECTION
WALL SECTION
EXTERIOR / INTERIOR
ELEVATION
INTERIOR MULTI-VIEW
ELEVATION
MATERIALS REFERENCE
DETAIL SECTION
AE402
C4
AE201
A1
AE305
SIM
A1
AE305
SIM
A1
AE305
SIM
AE505
C3
A3
ELEVATION NUMBER
SHEET ON WHICH
ELEVATION IS DRAWN
ELEVATION NUMBER
SHEET ON WHICH
ELEVATION IS DRAWN
ACTUAL SQ. FT.
ROOM NUMBER
DOOR NUMBER
KEYNOTE
WALL TYPE
REVISION NUMBER
ELEVATION INDICATION
COLUMN GRID
IDENTIFICATION
NORTH ARROW
WINDOW NUMBER
A1
EQUIPMENT TAG
D
NTRUE
NORTH
MATCHLINE
FINISH , FINISH MATERIAL FINISH EXTENTS
SPRAY FOAM
B
5E
1t
S
W1
ROOM NAME
A505B
150 SF
GENERAL SYMBOLS
ROOM CODE
ROOM NAME
A505B
OFA01
ROOM NUMBER
A. PARTITIONS AND WALLS
1. FLOOR PLAN DIMENSIONS ARE LOCATED FROM THE FINISHED FACE OF
PARTITIONS AND COLUMN CENTERLINES, UNLESS NOTED OTHERWISE.
2. THICKNESS OF CONCRETE MASONRY UNITS (CMU) AND LIGHT WEIGHT
MASONRY UNITS (LMU) PARTITIONS ARE NOMINAL UNLESS NOTED
OTHERWISE.
3. EXTERNAL EXPOSED CORNERS OF BLOCK WALLS AND PARTITIONS SHALL BE
BULLNOSE.
4. ALL PARTITIONS SHALL EXTEND FROM FLOOR TO UNDER SIDE OF DECK
ABOVE EXCEPT WHERE NOTED OR SHOWN OTHERWISE.
5. EXTEND ALL SOUND RATED PARTITIONS TO THE UNDER SIDE OF DECK ABOVE
TO PREVENT SOUND TRANSMISSION. FURNISH 4-1/4 POUNDS DENSITY GLASS
FIBER INSULATION SHAPED TO FIT THE VOID ABOVE THE PARTITION WHERE
AIR-BORNE SOUND CAN PENETRATE SPACE.
6. CONTROL JOINTS SHALL BE PROVIDED ABOVE DOORS AT EACH SIDE IN STUD
AND GWB PARTITIONS.
7. EXPANSION JOINTS AT ALL FLOORS, CEILINGS AND WALLS THAT ARE
EXPOSED TO VIEW SHALL BE COVERED WITH EXPANSION JOINT COVERS
APPROPRIATE FOR FINISHED SURFACES.
8. ALL COLUMNS WITHIN FINISHED SPACES SHALL BE FINISHED WITH SAME
MATERIALS SCHEDULED AT WALLS UNLESS OTHERWISE SHOWN OR
DETAILED.
9. PROVIDE ALL WALL AND FLOOR OPENINGS FOR MECHANICAL, DATA COMM.,
AND ELECTRICAL ITEMS.
10. SEAL AROUND ALL PENETRATIONS IN CORRIDOR WALLS TO PREVENT THE
PASSAGE OF SMOKE.
B. DOORS AND FRAMES
1. PROVIDE LABELS ON DOORS AND FRAMES WHERE SCHEDULED.
2. INSTALL CONTINUOUS CAULKING AROUND METAL FRAMES UNLESS NOTED
OTHERWISE.
3. HOLLOW METAL FRAMES SHALL BE ANCHORED TO THE STRUCTURAL FLOOR
WITH A MINIMUM OF TWO (2) ANCHOR BOLTS.
4. HOLLOW METAL FRAMES SHALL BE FILLED WITH GROUT TO THE DEPTH OF
THE FRAME ANCHOR FULL HEIGHT IN ORDER TO DAMPEN HOLLOW SOUND.
GROUT PRIOR TO SETTING IN PLACE.
5. INSTALL CASING (J) BEADS AND CAULK WHERE GWB ABUTS METAL FRAMES
WITHOUT SLIPPING BEHIND.
C. MISCELLANEOUS
1. PROJECT DRAWINGS ARE BASED ON RECORD DRAWINGS, ALL CONDITIONS
SHOWN SHALL BE VERIFIED IN FIELD PRIOR TO FABRICATION OF NEW ITEMS.
INFORM ARCHITECT OF ANY DISCREPANCIES FOUND AND REQUEST
DIRECTION.
2. PROVIDE BLOCKING AS REQUIRED TO SUPPORT WALL MOUNTED ITEMS
(INCLUDING, BUT NOT LIMITED TO, MAP RAILS, MARKER BOARDS, SIGNAGE,
CASEWORK, MILLWORK, GRAB BARS, TOILET ACCESSORIES, AND
EQUIPMENT). BLOCKING SHALL BE CONTINUOUS AND LOCATED BOTH AT
BOTTOM AND TOP OF EQUIPMENT.
3. PROVIDE BLOCKING AT RAILINGS AND GUARDRAILS CAPABLE OF
SUPPORTING THE POINT AND UNIFORM LOADS REQUIRED. WHERE MORE
THAN ONE CODE, STANDARD, OR GUIDELINE IS APPLICABLE, THE MOST
STRINGENT CASE SHALL BE ADHERED TO.
GENERAL ARCHITECTURAL NOTES
1. THE FOLLOWING GENERAL NOTES APPLY TO THE ENTIRE SET OF DRAWINGS
LISTED BY THE “SHEET INDEX”.
2. FOR GENERAL NOTES, ABBREVIATIONS, AND SYMBOLS APPLICABLE ONLY TO THE
DRAWINGS OF ONE DISCIPLINE, REFER TO THE DRAWINGS OF THAT DISCIPLINE –
SEE “INDEX OF DRAWINGS”.
3. THE SET OF DRAWINGS CONSISTS OF ALL DRAWINGS LISTED BY THE “INDEX OF
DRAWINGS”. THE WORK DESCRIBED BY THE DRAWINGS OF ANY ONE DISCIPLINE
MAY BE AFFECTED BY THE WORK DESCRIBED ON DRAWINGS OF ANOTHER
DISCIPLINE. DO NOT DISTRIBUTE OR UTILIZE PARTIAL SETS OF DRAWINGS.
4. ALL ARCHITECTURAL DRAWINGS ESTABLISH AND COORDINATE THE FINISHED
APPEARANCE AND LOCATION OF ALL EXPOSED ELEMENTS OF THE WORK,
INCLUDING THAT WORK, WHICH IS ILLUSTRATED PRIMARILY ON DRAWING OF
OTHER DISCIPLINES, UNLESS OTHERWISE NOTED ON THE DRAWINGS.
5. REFER TO THE STRUCTURAL, MECHANICAL, ELECTRICAL, PLUMBING, AND OTHER
SPECIALTY ENGINEERING DRAWINGS FOR THE DETAILED DESIGN, OF WHICH
PORTIONS MAY ALSO BE SHOWN ON THE ARCHITECTURAL DRAWINGS.
6. ALL PARTS OF THE WORK – INCLUDING MATERIALS, METHODS, ASSEMBLIES,
ETC – SHALL COMPLY WITH ALL APPLICABLE VHA RULES, CODES, REGULATIONS,
ORDINANCES, AND LAWS OF ALL FEDERAL, STATE DISTRICT, TERRITORIAL AND
LOCAL GOVERNMENT AUTHORITIES HAVING JURISDICTION OVER THE DESIGN,
CONSTRUCTION, AND OCCUPANCY OF THE PROJECT, WHETHER LISTED BY THE
CONTRACT DOCUMENTS OR NOT.
7. NO PART OF THE CONTRACT DOCUMENTS SHALL BE CONSTRUED TO REQUIRE OR
PERMIT WORK CONTRARY TO AN APPLICABLE VHA OR LOCAL GOVERNMENT RULE,
CODE, REGULATION, ORDINANCE, OR LAW.
8. IF A CONFLICT EXISTS BETWEEN THE CONTRACT DOCUMENTS AND A
REGULATORY REQUIREMENT, THE CONTRACTOR SHALL COMPLY WITH THE ONE
ESTABLISHING THE MORE STRINGENT OR RESTRICTIVE REQUIREMENT:
a. THE DRAWINGS AND SPECIFICATIONS MAY SET FORTH MORE DETAILED, MORE SPECIFIC, AND/OR MORE RESTRICTIVE REQUIREMENTS THAN THOSE
SET FORTH BY THE APPLICABLE REGULATORY REQUIREMENTS, WHERE THE
DRAWINGS AND SPECIFICATIONS PROVIDE MORE DETAILED, MORE SPECIFIC,
AND/OR MORE RESTRICTIVE REQUIREMENTS, THE CONTRACTOR SHALL
COMPLY WITH THOSE REQUIREMENTS.
b. WHERE THE APPLICABLE REQUIREMENTS OF THE REFERENCED RULES, CODES, REGULATIONS, ORDINANCES, OR LAWS ARE MORE RESTRICTIVE
THAN THAT SET FORTH BY THE DRAWINGS AND SPECIFICATION, THE
CONTRACTOR SHALL COMPLY WITH ALL SUCH MORE RESTRICTIVE
REQUIREMENTS. ALTHOUGH SUCH REQUIREMENTS MAY NOT BE
ILLUSTRATED BY THE DRAWINGS AND SPECIFICATIONS.
9. THE CONTRACTOR SHALL NOT SCALE DRAWINGS, ALL OF WHICH ARE
DIAGRAMMATIC IN NATURE. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS
AND EXISTING CONDITIONS PRIOR TO THE START OF WORK.
10. BEFORE STARTING WORK WITHIN AN OCCUPIED AREA, THE CONTRACTOR WILL BE
RESPONSIBLE TO SET-UP TEMPORARY/PERMANENT CONSTRUCTION/ICRA
BARRIERS WITH ANTEROOM AND MAINTAIN NEGATIVE PRESSURE. ALL
TEMPORARY CONSTRUCTION BARRIERS OUTSIDE THE INDICATED CONSTRUCTION
PHASE AREA WILL BE REMOVED AT THE CONCLUSION OF THE WORK SHIFT. THE
CONTRACTOR WILL BE RESPONSIBLE TO CLEAN AND PREPARE THE AREA TO BE
OCCUPIED BY MEDICAL CENTER STAFF AND RESIDENCE.
11. CONTRACTOR SHALL COMPLY WITH ALL VHA, FEDERAL AND LOCAL APPLICABLE
SAFETY CODES AND REGULATIONS DURING ALL PHASES OF CONSTRUCTION. IT IS
THE SOLE RESPONSIBILITY OF THE CONTRACTOR TO DETERMINE CONSTRUCTION
MEANS, METHODS, PROCEDURES AND SEQUENCES TO ENSURE THE SAFETY OF
THE EXISTING BUILDING AND OCCUPANTS.
12. DO NOT CUT AND PATCH STRUCTURAL ELEMENTS IN A MANNER THAT WOULD
REDUCE THEIR LOAD CARRYING CAPACITY OR LOAD-DEFLECTION RATIO.
13. WHERE EXISTING CONSTRUCTION, EQUIPMENT, ETC. IS REQUIRED TO BE
REMOVED, RESTORE EXPOSED FINISHES OF CUT AND PATCHED AREAS AND
EXTEND FINISH RESTORATION INTO ADJOINING CONSTRUCTION IN A MANNER
THAT WILL ELIMINATE EVIDENCE OF PATCHING AND REFINISHING. CUT EXISTING
CONSTRUCTION USING METHODS LEAST LIKELY TO DAMAGE ELEMENTS TO BE
RETAINED OR ADJOINING CONSTRUCTION. WHERE INDICATED TO REMOVE
FINISHES, REMOVE COMPLETELY, FROM PLANE TO PLANE. TREAT REMAINING
SUBSURFACE TO RECEIVE NEW FINISHES SPECIFIED.
14. WHERE REMOVAL OF EXISTING CONSTRUCTION, PIPING, DUCTWORK AND OTHER
ITEMS CREATES OPENINGS IN THE WALLS, FLOORS OR CEILINGS, PATCH
OPENINGS IMMEDIATELY WITH THE SAME MATERIALS AS ADJACENT
CONSTRUCTION. MAINTAIN THE REQUIRED FIRE RATING. SEE MEP DRAWINGS
FOR ADDITIONAL INFORMATION. FILL IN ALL EXISTING OPENINGS THAT ARE NOT
TO REMAIN, UNLESS OTHERWISE NOTED. FINISH TO MATCH PAINT FINISH OF
ADJACENT SURFACE WHERE OCCURS.
GENERAL CONDITION NOTES
SOUTH BED TOWER (SBT)
COMMUNITY LIVING
CENTER (CLC)
C . C
AS
IA
C. MAGA
AV. JOSE KIKO CUSTODIO
TRAIN TRACKS
NTRUE
NORTH
GATE 1: CLC ACCESS
GATE 2
GATE 3
NOTE:
NO ON-SITE CONTRACTOR PARKING IS AVAILABLE.
GATE 5: SBT ACCESS
REVISIONS
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
STAMPCONSULTANT
321 4 5 6 7 8 9 10
672-23-104
LAD NO.
Office of Construction and Facilities Management
CD (100%CD) FINAL BID DOCUMENTS – 03/14/2025
ARCHITECT/ENGINEER OF RECORD
A/E:
JUPITER
561-743-0165
ORLANDO
407-845-6630
WWW.RGDENGINEERS.COM
CERT OF AUTH 5454
121 S. ORANGE AVENUE, UNIT 1230N, ORLANDO, FL 32801
RGD PROJECT
#23-1050
8600 Indian Hills Dr Omaha, NE 68114 Tel 402.391.8111 Fax 402.391.8564
/1
/2
:3
:3
P
M
10 Calle Casia San Juan Puerto Rico 00921
GENERAL NOTES, SYMBOLS,
SHEET INDEX AND
ABBREVIATIONS
GI002
Construct VA Bariatric Bathrooms at Community Center and South Bed Tower
003-10296-000
03/14/2025 RAD WMB
A u to d e s k D o c s /V
A C o n s tr u c t B a ri a tr ic B a th ro o m s a t C
L C
S
B T
R
V
A S
J B
A R
-A rc h it e c tu re .r v t
100% CD - FINAL BID
DOCUMENTS
A
A/C AIR CONDITIONING
AB ANCHOR BOLT / AIR BLENDER
AC ALTERNATING CURRENT / AIR COMPRESSOR
ACP ASBESTOS CEMENT PIPE
ACU AIR CONDITIONING UNIT
AD AREA DRAIN
ADA AMERICANS WITH DISABILITIES ACT
ADJ ADJACENT / ADJUSTABLE
ADR ACCESS DOOR
AFF ABOVE FINISH FLOOR
AHJ AUTHORITY HAVING JURISDICTION
AHU AIR HANDLING UNIT
AL ALUMINUM
ALT ALTERNATE
APC ACOUSTICAL PANEL CEILING
APPROX APPROXIMATELY
ARCH ARCHITECT(URAL)
ATB AIR TERMINAL BOX
ATC ACOUSTICAL TILE CEILING
ATD AIR TRANSFER DUCT
AUX AUXILIARY
AVG AVERAGE
B
BD BOARD
BDD BACK DRAFT DAMPER
BE BOTTOM ELEVATION
BL BUILDING LINE
BLDG BUILDING
BLKG BLOCKING
BM BENCH MARK / BEAM
BRG BEARING
BTU BRITISH THERMAL UNIT
C
C/C CENTER TO CENTER
CAB CABINET
CC COOLING UNIT
CEM CEMENT
CFM CUBIC FEET PER MINUTE
CG CORNER GUARD
CI CURB INLET / CAST IRON
CIP CAST IRON PIPE
CJ CONTROL JOINT OR CONTRACTION JOINT
CL CENTER LINE
CLC COMMUNITY HEALTH CENTER
CLG CEILING
CLO CLOSET
CLR CLEAR
CMU CONCRETE MASONRY UNIT
CO CLEANOUT / CARBON MONOXIDE
COL COLUMN
COMB COMBINATION / COMBINE
COMP COMPRESSIBLE
CONC CONCRETE
CONN CONNECTION
CONST CONSTRUCTION
CONT CONTINUOUS / CONTINUATION
CONTR CONTRACTOR
COR CONTRACTING OFFICER REPRESENTATIVE
CORR CORRIDOR
CPT CARPET
CR CRASH RAIL
CS CONCRETE SEALER
CSF CUBIC FEET PER SECOND
CT CERAMIC TILE / COOLING TOWER
CTB CERAMIC TILE BASE
CTF CERAMIC TILE FLOOR
ABBREVIATIONS
CTR CENTER
CTW CERAMIC TILE WALL
CU CONDENSING UNIT
CUH CABINET UNIT HEATER
CW COLD WATER
D
D DRAIN / DIFFUSER
DA DENTAL AIR
DBL DOUBLE
DEPR DEPRESSED
DEPT DEPARTMENT
DET DETAIL
DF DRINKING FOUNTAIN
DIA DIAMETER
DIAG DIAGONAL
DIFF DIFFUSER
DIP DUCTILE IRON PIPE
DISP DISPENSER
DIST DISTRIBUTION
DK DECK
DL DEAD LOAD
DN DOWN
DR DOOR
DS DOWNSPOUT
DWG DRAWING
DWP DOMESTIC WATER PUMP
E
EA EACH / EXHAUST AIR
EF EACH FACE / EXHAUST FAN
EJ EXPANSION JOINT
EL ELEVATION
ELEC ELECTRIC(AL)
ELEV ELEVATOR
EMBED EMBEDMENT
EMD ESTIMATED MAXIMUM DEMAND
EMT ELECTRICAL METAL TUBING
ENG ENTRANCE GRATING
EP EPOXY PAINT
EQ EQUAL
EQUIP EQUIPMENT
ET EXPANSION TANK / EPOXY TERRAZZO
ETB EPOXY TERRAZZO INTEGRAL COVE BASE
EVAC MEDICAL GAS EVACUATION
EW EACH WAY
EWC ELECTRICAL WATER COOLER
EWH ELECTRICAL WATER HEATER
EXH EXHAUST
EXP EXPOSED
EXPN EXPANSION
EXST EXISTING
EXT EXTERIOR
F
FA FIRE ALARM
FCU FAN COIL UNIT
FD FLOOR DRAIN / FIRE DAMPER
FD / SD COMBINATION FIRE AND SMOKE DAMPER
FDC FIRE DEPARTMENT CONNECTION
FDN FOUNDATION
FE FIRE EXTINGUISHER
FEC FIRE EXTINGUISHER CABINET
FF&E FURNITURE, FIXTURE, AND EQUIPMENT
FHC FIRE HOSE CABINET
FIN FINISH
FIX FIXTURE
FL FLOOR
FM FORCE MAIN / FACTORY MUTUAL
FP FIREPROOFING / FIRE PUMP
FR FIRE RATED
FRP FIBERGLASS REINFORCED PLASTIC
FS FLOW SWITCH
FT FEET
FTG FOOTING
FV FIELD VERIFY
G
G GAS / GRILLE
GA GAGE
GALV GALVANIZED
GB GRAB BAR
GEN GENERATOR
GFRC GLASS FIBER REINFORCED CONCRETE
GI GALVANIZED IRON
GL GLASS
GLB GLASS BLOCK
GLP GLASS PANEL
GLT GLASS TILE
GPM GALLONS PER MINUTE
GR GRADE
GT GROUT
GWB GYPSUM WALLBOARD
GYP GYPSUM
H
HC HEATING COIL
HDW HARDWARE
HDWD HARDWOOD
HM HOLLOW METAL
HNDRL HANDRAIL
HORIZ HORIZONTAL
HPT HIGH POINT
HR HOUR
HT HEIGHT
HTG HEATING
HTR HEATER
HVAC HEATING, VENTILATING AND AIR CONDITIONING
HW HOT WATER
HWC HOT WATER CIRCULATING
I
IA INSTRUMENT AIR
IC INTERCOM
ID INSIDE DIAMETER
IE INVERT ELEVATION
IF INSIDE FACE
IN INCH
INSUL INSULATION
INT INTERIOR
J
JAN JANITOR
JB JUNCTION BOX
JSN JOINT SCHEDULE NUMBER
JST JOIST
JT JOINT
K
KC MIL THOUSAND CIRCULAR MILS
KCJ KEYED CONSTRUCTION JOINT
KIT KITCHEN
KV KILOVOLT
KW KILOWATTS
L
LAM LAMINATE
LAV LAVATORY
LBS POUNDS
LF LINEAR FEET
LIN LINEAR
LINO LINOLEUM
LL LIVE LOAD
LLH LONG LEG HORIZONTAL
LLV LONG LEG VERTICAL
LMU LIGHTWEIGHT MASONRY UNITS
LONG LONGITUDINAL
LT LIGHT
LT WT LIGHT WEIGHT
LTG LIGHTING
LV LABORATORY VACUUM
LVL LEVEL
LVT LUXURY VINYL TILE
M
M METER
M2 SQUARE METER
M3 CUBIC METER
MA MEDICAL AIR
MAINT MAINTENANCE
MAR MARBLE
MAS MASONRY
MAT MATERIAL
MAX MAXIMUM
MB METAL BASE
MDO MEDIUM DENSITY OVERLAY
ME MATCH EXISTING
MECH MECHANICAL
MET METAL
MFR MANUFACTURER
MG MOTOR GENERATOR / MEDICAL GAS
MH MANHOLE
MIN MINIMUM
MLO MAIN LUGS ONLY
MM MILLIMETER
MO MASONRY OPENING
MP METAL PANEL
MT METAL TRANSITION
MTD MOUNTED
MTG MOUNTING
MULL MULLION
MV MEDICAL VACUUM
N
N NITROGEN
N2O NITROUS OXIDE
NEC NATIONAL ELECTRICAL CODE
NFPA NATIONAL FIRE PROTECTION
NIC NOT IN CONTRACT
NO NUMBER
NOM NOMINAL
NTS NOT TO SCALE
O
O/S OFFSET
OA OUTSIDE AIR
OBD OPPOSED BLADE DAMPER
OC ON CENTER
OD OUTSIDE DIAMETER
OF OUTSIDE FACE
OPNG OPENING
OPP OPPOSITE
OX OXYGEN
OZ OUNCE
P
P PAINT / PUMP / PENDANT
PART PARTITION
PAT PATIENT
PAVT PAVEMENT
PCF POUNDS PER CUBIC FOOT
PED PEDESTAL
PERP PERPENDICULAR
PHVAC PLUMBING, HEATING, VENTILATING AND AIR
CONDITIONING
PI POINT OF INTERSECTION
PIV POST INDICATOR VALVE
PKG PARKING
PL PLASTIC LAMINATE / PROPERTY LINE / PLATE
PLAS PLASTER
PLBG PLUMBING
PLF POUNDS PER LINEAR FOOT
PLYWD PLYWOOD
PNL PANEL
POL CONC POLISHED CONCRETE
PR PAIR
PRF POURED RESINOUS FLOORING
PROJ PROJECTION
PRV PRESSURE REGULATING VALVE
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PT PORCELAIN TILE
PTVC POINT OF VERTICAL CURVATURE
PTW PORCELAIN TILE WALL
PVC POLYVINYL CHLORIDE
Q
QTB QUARRY TILE BASE
QTF QUARRY TILE FLOOR
QZP QUARTZ POLYMER
R
R RADIUS / REGISTER
RA RETURN AIR
RAF RAISED ACCESS FLOORING
RB RESILIENT BASE
RCP REINFORCED CONCRETE PIPE
RD ROOF DRAIN
REF REFERENCE
REFL REFLECTED
REG REGISTER
REINF REINFORCED
REQD REQUIRED
REV REVERSE / REVISION
RF RETURN FAN
RGS RIGID GALVANIZED STEEL
RH ROOF HOOD / RELATIVE HUMIDITY / REHEAT
RHC REHEAT COIL
RM ROOM
RO ROUGH OPENING
ROW RIGHT OF WAY
RS RESILIENT SHEET
RT RESILIENT TILE
S
S STAIR / STAIN / SURFACE / SANITARY
SA SUPPLY AIR / SOUND ATTENUATOR
SAN SANITARY
SBT SOUTH BED TOWER
SCH SCHEDULE
SD SMOKE DAMPER / SUB DRAIN / STORM SEWER
SECT SECTION
SF SUPPLY FAN
SHT SHEET
SIM SIMILAR
SOG SLAB-ON-GRADE
SPEC SPECIFICATIONS
SQ SQUARE
SS SERVICE SINK / SANITARY SEWER
SSM SOLID SURFACE MATERIAL
SSO STORM SEWER OVERFLOW
SSTL STAINLESS STEEL
STA STATION
STD STANDARD
STIFF STIFFENER
STIR STIRRUP
STL STEEL
STOR STORAGE
STR STRUCTURAL
SUSP SUSPENDED
SW SWITCH
SYM SYMMETRICAL
T
T TREAD
T&B TOP AND BOTTOM
T&G TONGUE AND GROOVE
TC TOP OF CURB
TE TOP ELEVATION
TEL TELEPHONE
TEMP TEMPERATURE
TERR TERRAZZO
TLT TOILET
TOPO TOPOGRAPHY
TOS TOP OF STEEL
TOW TOP OF WALL
TRANS TRANSVERSE
TS TRANSITION STRIP
TYP TYPICAL
U
UG UNDERGROUND
UH UNIT HEATER
UNO UNLESS NOTED OTHERWISE
UR URINAL
UV UNIT VENTILATOR
V
V VOLT
VACHS VA CARIBEAN HEALTH SYSTEM
VAV VARIABLE AIR VOLUME
VCP VITRIFIED CLAY PIPE
VCT VINYL COMPOSITION TILE
VERT VERTICAL
VEST VESTIBULE
VFD VARIABLE FREQUENCY DRIVE
VWC VINYL WALL COVERING
W
W WATT / WATER
W/ WITH
W/O WITHOUT
WAGD WASTE ANESTHESIA GAS DISPOSAL
WC WATER CLOSET / WALL COVERING
WD WOOD
WDB WOOD BASE
WDF WOOD FLOOR
WDP WOOD PANEL
WDW WINDOW
WDWF WINDOW FILM
WGD WALL GUARD
WH WATER HEATER / WALL HYDRANT
WP WEATHERPROOF
WPFG WATERPROOFING
WT WEIGHT / WINDOW TREATMENT
WWF WELDED WIRE FABRIC
X
XFMR TRANSFORMER
Y
YD YARD
YH YARD HYDRANT
SHEET INDEX
GENERAL
GI001 COVER SHEET
GI002 GENERAL NOTES, SYMBOLS, SHEET INDEX AND ABBREVIATIONS
GI003 FIXTURE AND ACCESSORIES LOCATIONS
STRUCTURAL
S100 GENERAL NOTES
S200 CLC ROOMS 4 THROUGH 6 FRAMING AND SUPPORTS
S201 SBT BLDG. LEVELS 3 THRU 6 FRAMING
S300 FIXTURE ACCESSORIES AND VERTICAL SUPPORT DETAILS
S400 MASONRY FRAMING DETAILS
ARCHITECTURAL
AD101C DEMOLITION PLANS - CLC LEVEL 1 AND 2
AD102C ENLARGED DEMOLITION PLANS - CLC LEVEL 1 AND 2
AE101C FLOOR PLANS - CLC LEVEL 1 AND 2
AE410C ENLARGED FLOOR PLANS - CLC LEVEL 1
AE411C ENLARGED FLOOR PLANS - CLC LEVEL 2
AD103S DEMOLITION PLANS - SBT LEVEL 3 AND 4
AD105S DEMOLITION PLANS - SBT LEVEL 5 AND 6
AE103S FLOOR PLANS - SBT LEVEL 3 AND 4
AE105S FLOOR PLANS - SBT LEVEL 5 AND 6
AE410S ENLARGED FLOOR PLANS - SBT
AE420 INTERIOR ELEVATIONS - CLC
AE421 INTERIOR ELEVATIONS - SBT
AE450 CASEWORK AND INTERIOR DETAILS
AE600 PARTITION TYPES AND DETAILS
AE602 DOOR SCHEDULE, DOOR FRAME TYPES, DOOR DETAILS
INTERIORS
IN100C ENLARGED FINISH FLOOR PLANS CLC
IN100S ENLARGED FINISH FLOOR PLANS SBT
IN501 INTERIOR FINISH DETAILS
IN600 ROOM FINISH SCHEDULE
IN601 SCHEDULE OF FINISHES
FIRE PROTECTION
F-101 FIRE PROTECTION FLOOR PLAN - CLC LEVEL 1
F-102 FIRE PROTECTION FLOOR PLAN - CLC LEVEL 2
F-103 FIRE PROTECTION FLOOR PLAN - SBT LEVEL 3
F-104 FIRE PROTECTION FLOOR PLAN - SBT LEVEL 4
F-105 FIRE PROTECTION FLOOR PLAN - SBT LEVEL 5
F-106 FIRE PROTECTION FLOOR PLAN - SBT LEVEL 6
FD-201 ENLARGED FIRE PROTECTION DEMO FLOOR PLANS - CLC
FD-202 ENLARGED FIRE PROTECTION DEMO FLOOR PLANS - SBT
F-201 ENLARGED FIRE PROTECTION FLOOR PLANS - CLC
F-202 ENLARGED FIRE PROTECTION FLOOR PLANS - SBT
PLUMBING
P-001 PLUMBING COVER SHEET
PD-101 GRAVITY PIPING DEMO FLOOR PLAN - CLC LEVEL 1
PD-102 PRESSURE PIPING DEMO FLOOR PLAN - CLC LEVEL 1
PD-103 GRAVITY PIPING DEMO FLOOR PLAN - CLC LEVEL 2
PD-104 PRESSURE PIPING DEMO FLOOR PLAN - CLC LEVEL 2
PD-105 GRAVITY PIPING DEMO FLOOR PLAN - SBT LEVEL 3
PD-106 PRESSURE PIPING DEMO FLOOR PLAN - SBT LEVEL 3
PD-107 GRAVITY PIPING DEMO FLOOR PLAN - SBT LEVEL 4
PD-108 PRESSURE PIPING DEMO FLOOR PLAN - SBT LEVEL 4
PD-109 GRAVITY PIPING DEMO FLOOR PLAN - SBT LEVEL 5
SCALE: NTS
SITE PLAN - SAN JUAN VA MEDICAL CENTER
SHEET INDEX
PD-110 PRESSURE PIPING DEMO FLOOR PLAN - SBT LEVEL 5
PD-111 GRAVITY PIPING DEMO FLOOR PLAN - SBT LEVEL 6
PD-112 PRESSURE PIPING DEMO FLOOR PLAN - SBT LEVEL 6
PD-201 MEDICAL GAS PIPING DEMO FLOOR PLAN - CLC LEVEL 1
PD-202 MEDICAL GAS PIPING DEMO FLOOR PLAN - CLC LEVEL 2
PD-203 MEDICAL GAS PIPING DEMO FLOOR PLAN - SBT LEVEL 3
PD-204 MEDICAL GAS PIPING DEMO FLOOR PLAN - SBT LEVEL 4
PD-205 MEDICAL GAS PIPING DEMO FLOOR PLAN - SBT LEVEL 5
PD-206 MEDICAL GAS PIPING DEMO FLOOR PLAN - SBT LEVEL 6
PD-401 ENLARGED GRAVITY PIPING DEMO FLOOR PLANS - CLC
PD-402 ENLARGED PRESSURE PIPPING DEMO FLOOR PLANS - CLC
PD-403 ENLARGED GRAVITY PIPING DEMO FLOOR PLANS - SBT
PD-404 ENLARGED PRESSURE PIPING DEMO FLOOR PLANS - SBT
PD-405 ENLARGED MEDICAL GAS PIPING DEMO FLOOR PLANS - CLC
PD-406 ENLARGED MEDICAL GAS PIPING DEMO FLOOR PLANS - SBT
P-101 GRAVITY PIPING FLOOR PLAN - CLC LEVEL 1
P-102 PRESSURE PIPING FLOOR PLAN - CLC LEVEL 1
P-103 GRAVITY PIPING FLOOR PLAN - CLC LEVEL 2
P-104 PRESSURE PIPING FLOOR PLAN - CLC LEVEL 2
P-105 GRAVITY PIPING FLOOR PLAN - SBT LEVEL 3
P-106 PRESSURE PIPING FLOOR PLAN - SBT LEVEL 3
P-107 GRAVITY PIPING FLOOR PLAN - SBT LEVEL 4
P-108 PRESSURE PIPING FLOOR PLAN - SBT LEVEL 4
P-109 GRAVITY PIPING FLOOR PLAN - SBT LEVEL 5
P-110 PRESSURE PIPING FLOOR PLAN - SBT LEVEL 5
P-111 GRAVITY PIPING FLOOR PLAN - SBT LEVEL 6
P-112 PRESSURE PIPING FLOOR PLAN - SBT LEVEL 6
P-200 MEDICAL GAS PIPING FLOOR PLAN - BLDG 1 BASEMENT
(EXISTING)
P-201 MEDICAL GAS PIPING FLOOR PLAN - CLC LEVEL 1
P-202 MEDICAL GAS PIPING FLOOR PLAN - CLC LEVEL 2
P-203 MEDICAL GAS PIPING FLOOR PLAN - SBT LEVEL 3
P-204 MEDICAL GAS PIPING FLOOR PLAN - SBT LEVEL 4
P-205 MEDICAL GAS PIPING FLOOR PLAN - SBT LEVEL 5
P-206 MEDICAL GAS PIPING FLOOR PLAN - SBT LEVEL 6
P-401 ENLARGED GRAVITY PIPING FLOOR PLANS - CLC
P-402 ENLARGED PRESSURE PIPPING FLOOR PLANS - CLC
P-403 ENLARGED GRAVITY PIPING FLOOR PLANS - SBT
P-404 ENLARGED PRESSURE PIPING FLOOR PLANS - SBT
P-405 ENLARGED MEDICAL GAS PIPING FLOOR PLANS - CLC
P-406 ENLARGED MEDICAL GAS PIPING FLOOR PLANS - SBT
P-501 ENLARGED GRAVITY AND PRESSURE PIPING ISOMETRICS - CLC
P-502 ENLARGED GRAVITY, PRESSURE AND MEDICAL GAS PIPING
ISOMETRICS - SBT
P-503 OVERALL MEDICAL GAS PIPING ISOMETRICS - CLC
P-601 PLUMBING DETAILS AND SCHEDULES
MECHANICAL
M-001 MECHANICAL COVER SHEET
M-002 MECHANICAL SYMBOLS & ABBREVIATIONS
MD-101 MECHANICAL DEMOLITION FLOOR PLAN - CLC LEVEL 1
MD-102 MECHANICAL DEMOLITION FLOOR PLAN - CLC LEVEL 2
MD-103 MECHANICAL DEMOLITION FLOOR PLAN - SBT LEVEL 3
MD-104 MECHANICAL DEMOLITION FLOOR PLAN - SBT LEVEL 4
MD-105 MECHANICAL DEMOLITION FLOOR PLAN - SBT LEVEL 5
MD-106 MECHANICAL DEMOLITION FLOOR PLAN - SBT LEVEL 6
MD-401 MECHANICAL DEMOLITION ENLARGED FLOOR PLAN - CLC LEVEL 1
MD-402 MECHANICAL DEMOLITION ENLARGED FLOOR PLAN - CLC LEVEL 2
MD-403 MECHANICAL DEMOLITION ENLARGED FLOOR PLAN - SBT LEVEL 3
SHEET INDEX
MD-404 MECHANICAL DEMOLITION ENLARGED FLOOR PLAN - SBT LEVEL 4
MD-405 MECHANICAL DEMOLITION ENLARGED FLOOR PLAN - SBT LEVEL 5
MD-406 MECHANICAL DEMOLITION ENLARGED FLOOR PLAN - SBT LEVEL 6
MH-101 MECHANICAL FLOOR PLAN - CLC LEVEL 1
MH-102 MECHANICAL FLOOR PLAN - CLC LEVEL 2
MH-103 MECHANICAL FLOOR PLAN - SBT LEVEL 3
MH-104 MECHANICAL FLOOR PLAN - SBT LEVEL 4
MH-105 MECHANICAL FLOOR PLAN - SBT LEVEL 5
MH-106 MECHANICAL FLOOR PLAN - SBT LEVEL 6
MH-401 MECHANICAL ENLARGED FLOOR PLAN - CLC LEVEL 1
MH-402 MECHANICAL ENLARGED FLOOR PLAN - CLC LEVEL 2
MH-403 MECHANICAL ENLARGED FLOOR PLAN - SBT LEVEL 3
MH-404 MECHANICAL ENLARGED FLOOR PLAN - SBT LEVEL 4
MH-405 MECHANICAL ENLARGED FLOOR PLAN - SBT LEVEL 5
MH-406 MECHANICAL ENLARGED FLOOR PLAN - SBT LEVEL 6
MH-501 MECHANICAL DETAILS
MH-502 MECHANICAL DETAILS
MH-503 MECHANICAL DETAILS
MH-601 MECHANICAL SCHEDULES
MI-101 MECHANICAL CONTROLS DIAGRAM
ELECTRICAL
EJ001 ELECTRICAL NOTES AND SYMBOL LEGENDS
ED101 ELECTRICAL DEMOLITION OVERALL PLAN - CLC
ED101A ELECTRICAL ENLARGED DEMOLITION PLAN - CLC ROOMS
ED101B ELECTRICAL ENLARGED DEMOLITION PLAN - CLC ROOMS
ED102 ELECTRICAL DEMOLITION OVERALL PLAN - SBT
ED102A ELECTRICAL ENLARGED DEMOLITION PLAN - SBT ROOMS
ED102B ELECTRICAL ENLARGED DEMOLITION PLAN - SBT ROOMS
EP101 ELECTRICAL OVERALL PLAN - CLC
EP101A ELECTRICAL ENLARGED POWER PLAN - CLC ROOMS
EP101B ELECTRICAL ENLARGED POWER PLAN - CLC ROOMS
EP102 ELECTRICAL OVERALL PLAN - SBT
EP102A ELECTRICAL ENLARGED POWER PLAN - SBT ROOMS
EP102B ELECTRICAL ENLARGED POWER PLAN - SBT ROOMS
EP201 ELECTRICAL ENLARGED ROOMS
EL101A ELECTRICAL ENLARGED LIGHTING PLAN - CLC ROOMS
EL101B ELECTRICAL ENLARGED LIGHTING PLAN - CLC ROOMS
EL102A ELECTRICAL ENLARGED LIGHTING PLAN - SBT ROOMS
EL102B ELECTRICAL ENLARGED LIGHTING PLAN - SBT ROOMS
EK101 ELECTRICAL PANEL SCHEDULES - CLC
EK102 ELECTRICAL PANEL SCHEDULES - CLC
EK103 ELECTRICAL PANEL SCHEDULES - SBT
EK104 ELECTRICAL PANEL SCHEDULES - SBT
EK105 ELECTRICAL PANEL SCHEDULES - SBT
EK106 ELECTRICAL PANEL SCHEDULES - SBT
EK107 ELECTRICAL PANEL SCHEDULES - SBT
EK108 ELECTRICAL PANEL SCHEDULES - SBT
EK201 ELECTRICAL DETAILS
EK202 ELECTRICAL LIGHTING SCHEDULE & DETAILS
ET001 LOW VOLTAGE ELECTRICAL NOTES AND SYMBOL LEGENDS
ET101A LOW VOLTAGE ENLARGED PLAN - CLC ROOMS
ET101B LOW VOLTAGE ENLARGED PLAN - CLC ROOMS
ET102A LOW VOLTAGE ENLARGED PLAN - SBT ROOMS
ET102B LOW VOLTAGE ENLARGED PLAN - SBT ROOMS
ET201 LOW VOLTAGE DETAILS
MIN CLEAR
1'-3"
M A
X T
O R
IM
2' -1
0"
R E
F
LE
C T
IN
G
S U
R F
A C
E O
F M
IR
R
O R
3' -4
M
A X
T O
B O
MIRROR
MIN
8" DEEP
T O
R
IM
2' -1
0" M
A X
2'-1" MAX
1'-5" MIN
9" M
IN
9" M
IN
SIDE VIEW FRONT VIEW
1'-5" MIN
LAVATORY
PLUMBING LINES
WITHIN HATCHED
AREA REQUIRED
TO BE INSULATED
LINES OF REQUIRED
CLEARANCE
FINISH FLOOR
4'-0" MIN CLR
2' -3
M
IN
7"
CLEAR SPACE
ALLOWABLE FOR
ACCESSIBILITY
MIRROR
C
LR
K N
E E
S P
A C
E
2' -3
M
IN
7"
LINES OF REQUIRED
CLEARANCE
CLEARANCE
6" MAX TOE
T O
O P
E R
A T
IN
G
M E
C H
A N
IS
M
3' -4
M
A X4'
-6
4' -0
ROBE HOOK
(RH)
SOAP DISPENSER
SURFACE MTD
(SD)
4' -0
TOWEL BAR
(TB)
2' -9
SWING UP
GRAB BAR
T O
O P
E R
A T
IN
G
M E
C H
A N
IS
M
3' -4
M
A X
T O
O P
E R
A T
IN
G
M E
C H
A N
IS
M
3' -4
M
A X
T O
O P
E R
A T
IN
G
M E
C H
A N
IS
M
3' -4
M
A X
PAPER TOWEL
DISPENSER WALL MTD
(PTD)
4' -0
M
A X
3' -4
M
IN
VARIES FROM 3'-4"
HEIGHT FOR MAX 6"
DEPTH, TO 4'-0" HEIGHT
FOR MAX 1/2" DEPTH
3' -4
A
B O
V E
F
IN
IS
H
F
LO
O R
T O
B O
T T
O M
O F
R E
F L
S U
R F
A C
E
MIRROR
(MR)
4' -0
M
IN
2'-6" MIN
1' -5
M
IN
1' -7
M
A X
SINK
CLEAR FLOOR
SPACE
CLEARANCE AT SINK
GENERAL SHEET NOTES
A. ACCESSIBILITY DETAILS SHOWN SHALL BE USED WHERE ACCESSIBLE WORK IS
IDENTIFIED IN THESE DOCUMENTS. CONTRACTOR SHALL THOROUGHLY REVIEW THESE
DOCUMENTS. SHOULD ANY CONFLICTS IN THESE DOCUMENTS ARISE, THE CONTRACTOR
SHALL NOTIFY OWNER'S REPRESENTATIVE IN WRITING PRIOR TO PURCHASE,
INSTALLATION, AND CONSTRUCTION OF ANY ELEMENT OF THE WORK.
B. WHERE MORE THAN ONE CODE AND / OR STANDARD IS INDICATED AS BEING APPLICABLE,
THE MOST STRINGENT CASE SHALL BE ADHERED TO.
C. PROVIDE 6'-0" CIRCULAR TURNING SPACE IN BARATRIC PATIENT ROOMS AND TOILETS.
PROVIDE 5'-6" CIRCULAR TURNING SPACE NON-BARATRIC ROOMS.
PLAN
VERTICAL
GRAB BAR
GRAB BAR
ELEV A1
1' -6
3'
-0
6" 3'-0" 2"
E
LE
V B
3' -6
3' -4
6' -0
2'-0" 6"
2' -9
SLIDE BAR
GRAB BARS
SOAP DISPENSER
CONTROLS
SHOWER HEAD
GRAB BAR
GRAB BAR
VERTICAL GRAB BAR
ELEV A
ELEV A1
3'-0" 6"
2' -9
GRAB BAR
SHOWER
CORNER
(CORNER OPP
SIDE WHEN
OCCURS)SHOWER
CORNER
(CORNER
OPPOSITE SIDE
WHEN OCCURS)
MIN 59"
LONG HOSE
PROVIDE CLEAR AREA FOR SHOWER
4'-0"
6' -0
3'-0"
WATER CLOSET WATER CLOSET
CLEAR MIN
3'-0"
CLEAR MIN
3'-0"
CLEAR SPACE
3'-10"
6' -0
REVISIONS
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
STAMPCONSULTANT
321 4 5 6 7 8 9 10
672-23-104
LAD NO.
Office of Construction and Facilities Management
CD (100%CD) FINAL BID DOCUMENTS – 03/14/2025
ARCHITECT/ENGINEER OF RECORD
A/E:
JUPITER
561-743-0165
ORLANDO
407-845-6630
WWW.RGDENGINEERS.COM
CERT OF AUTH 5454
121 S. ORANGE AVENUE, UNIT 1230N, ORLANDO, FL 32801
RGD PROJECT
#23-1050
8600 Indian Hills Dr Omaha, NE 68114 Tel 402.391.8111 Fax 402.391.8564
/1
/2
:3
:3
P
M
10 Calle Casia San Juan Puerto Rico 00921
FIXTURE AND ACCESSORIES
LOCATIONS
GI003
Construct VA Bariatric Bathrooms at Community Center and South Bed Tower
003-10296-000
03/14/2025 RAD WMB
A u to d e s k D o c s /V
A C o n s tr u c t B a ri a tr ic B a th ro o m s a t C
L C
S
B T
R
V
A S
J B
A R
-A rc h it e c tu re .r v t
100% CD - FINAL BID
DOCUMENTS
SCALE: 1/2" = 1'-0"
ACCESSIBLE LAVATORY CLEARANCE
SCALE: 1/2" = 1'-0"
TOILET FIXTURE AND ACCESSORIES
SCALE: 1/4" = 1'-0"
CLEAR FLOOR SPACES
2'
SCALE : 1/4" = 1'-0"
0 4' 8'
1'
SCALE : 1/2" = 1'-0"
0 2' 4'
SCALE: 1/2" = 1'-0"
VA PATIENT ACCESSIBLE SHOWER ROLL-IN
PATIENT TOILET LOCATION
BARIATRIC PATIENT TOILET LOCATION
S I D E W A L K
S I D E W A L K
PATIENT RM
IA-118
IA-117
IB-128IB-127
IB-126
IB-134IB-135IB-136IB-137IB-138IB-139IB-140
IB-142
IC-143
IC-150
IC-151
IC-152
IC-153
IC-155
IC-154
IC-1A
IA-119
IA-120
IA-121
IA-122
IA-123
IA-124
IB-125
IA-111
IA-110
IA-108
IC-157
IC-156
IC-156a
IA-100
IA-106
IA-104
IC-158
CI-1A
IC-159
IA-107 IA-109
IA-105
IC-144
IB-141
FUT. ELEV.
S-3
S-2
S-1
PATIENT RM
UP
STAIR #3
PATIENT RM
PATIENT RM
TLT
PATIENT RM
TLT
EXAM
W. SUPPLY
N. CALL
RES. LOUNGE
SOCIAL WK.
OFFICE
PATIENT
TLT
STG.
TLT
LOBBY
EQ. STG.
LAUNDRY
CORRIDOR
TLT QUIET
NURSES CLO.
KITCHEN
NURS.
HAC
TLT
CL. LINEN
CONG. BATH
STAIR #1
PATIENT RM
PATIENT RM
PATIENT RM
TLT
PATIENT RM
PATIENT RMPATIENT RM
TLT
STAIR
#2
PATIENT RM
TLT
PATIENT RMPATIENT RMPATIENT RM
STAFF
TLT
TLT
TLT
MACH. ROOM
ELEVATOR
ADMINISTRATIVE
OFFICES
LIVING CENTER
COMMUNITY
STG.
OFFICE
SUPERVISOR
NURSE
MEDIC
& CLERK
STATION
NURSE
BATH
ROOM
SOIL UTILITY
TLTTLT
TLT
TLT
PATIENT RM
PATIENT RM
TLT
PATIENT RM
IA-103
STAIR #3
#2
S-3
2A-107
2A-105
2C-156a
2C-156 2A-100
C2-1B
2B-1342B-1352B-136
2A-118
2A-119
2A-120
2A-117
2A-116
2A-121
2A-122
2B-127 2B-128
2B-1372B-1382B-139
2A-123
2B-125
2A-124
2A-111
2A-108
2A-110
2B-126
2B-142
2C-144
2B-141
C2-1A
2C-159
2C-158
2C-154
C2-1A
2C-157
2C-155
2A-109
2B-140
2C-143
2A-106
2C-149
2C-153
2C-152
2C-151
2C-150
PATIENT RM
PATIENT RM
TLT
PATIENT RM
PATIENT RM
TLT
PATIENT RM
PATIENT
TLT
THERAPY
EQ. STG.
QUIET
PATIENT RM
SOCIAL WK.
OFFICE
N. CALL
LAUND.
CORR.
W. SUPPLY
MEDIC
& CLERK
NURSE STATION
BATH
STAFF TLT
ROOM
SOIL UTILITY
BATH
NURSE
OFFICE
EXAM
MACHINE
TLT
NURSES CLO.
CL. LINEN
CONG. BATH
PATIENT RM
TLT
PATIENT RM PATIENT RM
PATIENT RM
STAIR #1
PATIENT RM
TLT
PATIENT RM
PATIENT RM
PATIENT RM
TLT
PATIENT RM
PATIENT RM
PATIENT RM
PATIENT RM
TLT
PATIENT RM
TLT
STAIR
TERRACE
LAUNDRY
FUT. ELEV.
RES. LOUNGE
PATIENT
TLT
PRIMARY CARE
HOME BASE SOCIAL
WORK
RECREATION
OFFICE
ICE
CORRIDOR
PATIENT RM
TLT
TLT
TLT
TLT
UP
AD102C
B3
AD102C
B5
AD102C
B1
100'-0"
AREA A
AREA B
AREA B
AREA C
S T U V WS1 U2 X Y Z
R
AD102C
D3
AD102C
D1
AD102C
D5
114'-0"
AREA A
AREA B
AREA B
AREA C
S T U V WS1 U2 X Y Z
R
PAT RM
1A-116
PAT RM
1A-115
PAT RM
1A-114
PAT RM
1A-113
PAT ROOM
1B-129
PAT RM
1B-130
PAT RM
1B-131
PAT RM
1B-132
PAT RM
1C-145
PAT RM
1C-146
PAT RM
1C-147
PAT RM
1C-148
PAT RM
1C-149
CORRIDOR
C2-2WA-1
CORRIDOR
C2-3WB-2
CORRIDOR
C2-4WC-3
PAT RM
1B-133
PAT RM
1A-112
PAT ROOM
2A-116
PAT ROOM
2A-115
PAT ROOM
2A-114
PAT ROOM
2A-113
PAT ROOM
2B-129
PAT ROOM
2B-130
PAT ROOM
2B-131
PAT ROOM
2B-132
PAT ROOM
2C-145
PAT RM
2C-146
PAT RM
2C-147
PAT RM
2C-148
PAT RM
2C-149
CORRIDOR
C2-3WB-2
CORRIDOR
C1-2WA-6
CORRIDOR
C1-4WB-8
PAT RM
2B-133
NTRUE
NORTH
REVISIONS
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
STAMPCONSULTANT
321 4 5 6 7 8 9 10
672-23-104
LAD NO.
KEY PLAN NTS
Office of Construction and Facilities Management
BED
CLC
SICU
LAUNDRY
PARKING
GENERATORS
IWC
TWR
OPA
BLDG-1
ADMIN
CD (100%CD) FINAL BID DOCUMENTS – 03/14/2025
ARCHITECT/ENGINEER OF RECORD
A/E:
JUPITER
561-743-0165
ORLANDO
407-845-6630
WWW.RGDENGINEERS.COM
CERT OF AUTH 5454
121 S. ORANGE AVENUE, UNIT 1230N, ORLANDO, FL 32801
RGD PROJECT
#23-1050
8600 Indian Hills Dr Omaha, NE 68114 Tel 402.391.8111 Fax 402.391.8564
/1
/2
:2
:1
P
M
10 Calle Casia San Juan Puerto Rico 00921
DEMOLITION PLANS - CLC LEVEL
1 AND 2
AD101C
Construct VA Bariatric Bathrooms at Community Center and South Bed Tower
003-10296-000
03/14/2025 RAD WMB
A u to d e s k D o c s /V
A C o n s tr u c t B a ri a tr ic B a th ro o m s a t C
L C
S
B T
R
V
A S
J B
A R
-A rc h it e c tu re .r v t
100% CD - FINAL BID
DOCUMENTS
SCALE: 1/16" = 1'-0"
F1
DEMOLITION PLAN - CLC LEVEL 1
SCALE: 1/16" = 1'-0"
F5
DEMOLITION PLAN - CLC LEVEL 2
8'
SCALE : 1/16" = 1'-0"
0 16' 32'
X Y
SEE DEMOLITION
PLAN B1 THIS
SHEET FOR
TYPICAL NOTES
SEE DEMOLITION
PLAN B1 THIS
SHEET FOR
TYPICAL NOTES
REMOVE PARTIAL
HEIGHT WALL AND SILL
AS REQUIRED FOR
NEW WORK
BED REMOVAL AND
REPLACEMENT IS NIC,
TYPICAL REMOVE ROOM SIGNAGE
AND SHADOW BOX WHERE
OCCURS AT REMOVED
CORRIDORE DOORS.
SALVAGE FOR REUSE
REMOVE CRASH RAILS AND
BUMPERS AS REQUIRED FOR
WORK. TYPICAL AT CORRIDORS
AT AREAS OF WORK
CORRIDOR
C2-2WA-1
SEE DEMOLITION
PLAN B1 THIS
SHEET FOR
TYPICAL NOTES
X Y
CORRIDOR
C2-3WB-2
SEE DEMOLITION
PLAN B1 THIS
SHEET FOR
TYPICAL NOTES
CORRIDOR
2C-4WC-3
SEE DEMOLITION
PLAN B1 THIS
SHEET FOR
TYPICAL NOTES
PAT RM
1A-116
PAT RM
1A-115
PAT RM
1A-114
PAT RM
1A-113
CORRIDOR
C2-2WA-1
PAT RM
1A-112
PAT TLT
1A-115A
PAT TLT
1A-113A
PAT ROOM
1B-129
PAT RM
1B-130
PAT RM
1B-131
PAT RM
1B-132
CORRIDOR
C2-3WB-2
PAT RM
1B-133
PAT TLT
1B-130B
PAT TLT
1B-132A
PAT RM
1C-145
PAT RM
1C-146
PAT RM
1C-147
PAT RM
1C-148
PAT RM
1C-149
CORRIDOR
C2-4WC-3
PAT TLT
1C-145A
PAT TLT
1C-147A
PAT ROOM
2A-116
PAT ROOM
2A-115
PAT ROOM
2A-114
PAT ROOM
2A-113
PAT ROOM
2A-112
PAT RM
2A-115A
PAT RM
2A-113A
PAT ROOM
2B-129
PAT ROOM
2B-130
PAT ROOM
2B-131
PAT ROOM
2B-132
PAT RM
2B-133
PAT TLT
2B-130A
PAT TLT
2B-132A
PAT ROOM
2C-145
PAT RM
2C-146
PAT RM
2C-147
PAT RM
2C-148
PAT RM
2C-149
PAT TLT
2C-145A
PAT TLT
2C-147A
1. DASHED AREAS INDICATE MATERIAL OR EQUIPMENT TO BE REMOVED.
2. CONSTRUCTION SCHEDULING AND SEQUENCING SHALL BE COORDINATED WITH
COR PRIOR TO BEGINNING ANY WORK. COORDINATE DEMOLITION WORK TO
ACCOMMODATE VHA'S NORMAL OPERATIONS.
3. THE GENERAL CONTRACTOR SHALL ACCEPT THE PROJECT AS IT EXISTS.
4. REPORT CONFLICTS AND/OR DISCREPANCIES DISCOVERED IN DOCUMENTS TO
THE COR FOR CLARIFICATION PRIOR TO STARTING WORK.
5. THE EXISTING CONDITIONS, WHETHER OR NOT SPECIFICALLY NOTED ON THE
DRAWINGS, SHALL BE VERIFIED BY THE GENERAL CONTRACTOR PRIOR TO THE
COMMENCEMENT OF WORK.
6. DEMOLITION DRAWINGS INDICATE GENERAL SCOPE OF WORK ONLY. NOT ALL
DEMOLITION WORK NECESSARY IS SPECIFICALLY INDICATED. THE EXTENT AND
METHOD OF DEMOLITION SHALL BE AS REQUIRED TO ACCOMMODATE NEW WORK.
7. PATCH AND REPAIR EXISTING CONSTRUCTION WHICH IS DAMAGED OR DISTURBED
DURING DEMOLITION TO MATCH EXISTING OR RESTORE TO ITS ORIGINAL
CONDITION INCLUDING PAINTING.
8. CONTRACTOR SHALL COORDINATE DEMOLITION AND CUT AND PATCHING WORK
WITH NEW CONSTRUCTION TO MINIMIZE CUT AND PATCHING. SEE NEW
CONSTRUCTION DRAWINGS FOR COORDINATION AND THE SPECIFICATIONS FOR
CUT AND PATCHING REQUIREMENTS.
9. ALL PENETRATIONS ARE TO BE APPROVED BY THE COR PRIOR TO THE
COMMENCEMENT OF ANY CUTTING AND CORING.
10. FOR ADDITIONAL DEMOLITION INFORMATION SEE STRUCTURAL, MECHANICAL,
ELECTRICAL AND PLUMBING DRAWINGS FOR REQUIRED STRUCTURAL,
MECHANICAL, ELECTRICAL, DATA COMM, AND PLUMBING DEMOLITION.
11. WHERE AREAS OR ITEMS THAT ARE INDICATED TO BE REMOVED, ABUT OR ADJOIN
EXISTING CONSTRUCTION INDICATED TO REMAIN, SAWCUT OR OTHERWISE
REMOVE TO PROVIDE A CLEAN EDGE. IF EVIDENCE OF DEMOLITION WILL NOT BE
CONCEALED BY NEW WORK, PATCH AND/OR REPAIR TRANSITION TO MATCH
ADJACENT SURFACE AND FINISH.
12. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROTECTION OF EXISTING
STRUCTURES SURROUNDING THE CONTRACT AREA. DAMAGE TO EXISTING
STRUCTURES OR EQUIPMENT SHALL BE REPAIRED OR REPLACED AT NO
ADDITIONAL COST TO VHA.
13. ERECT TEMPORARY PARTITIONS/BARRIERS AS REQUIRED TO PREVENT
CONTAMINATION OF ADJACENT AREAS THAT ARE OR WILL BE USED BY VHA.
CONTAMINATION INCLUDES DUST, DEBRIS, AND EXCESSIVE NOISE CAUSED BY
DEMOLITION ACTIVITIES.
14. SHORE AND/OR BRACE EXISTING WORK AS REQUIRED TO SAFELY REMOVE
ITEM(S) OR EXISTING CONSTRUCTION WITHOUT DAMAGE TO EXISTING
CONSTRUCTION INDICATED TO REMAIN.
15. DO NOT MODIFY EXISTING STRUCTURE UNLESS SPECIFICALLY INDICATED ON THE
DRAWINGS OR APPROVED IN ADVANCE BY COR.
16. COORDINATE WITH COR REGARDING MODIFICATIONS TO EXISTING AV, PHONE,
SECURITY SYSTEMS, ETC. PRIOR TO DEMOLITION.
17. IF MATERIALS CONTAINING ASBESTOS ARE IDENTIFIED WITHIN THE
CONSTRUCTION AREA, THE MATERIAL SHALL NOT BE DISTURBED UNLESS THE
RENOVATION REQUIRES ITS REMOVAL. ANY DISTURBANCE TO MATERIAL
CONTAINING ASBESTOS SHALL BE IN ACCORDANCE WITH THE JEGS, EPA
REGULATIONS, AND VHA SPECIFICATIONS.
18. REMOVE EXISTING PATIENT LIFTS AND ABOVE CEILING SUPPORTS AS REQUIRED
AT AREAS OF WORK.
19. VAMC TO REMOVE ALL BEDS FROM AREAS OF WORK.
20. AT REMOVED CORRIDOR DOORS SALVAGE EXISTING ROOM SIGNAGE (AND
SHOWDOW BOXES WHERE OCCURS)
21. REMOVE PORTIONS OF CRASH RAIL AND BUMPER AT CORRIDORS AS REQUIRED
FOR NEW WORK.
GENERAL DEMOLITION NOTES
NTRUE
NORTH
REVISIONS
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
STAMPCONSULTANT
321 4 5 6 7 8 9 10
672-23-104
LAD NO.
KEY PLAN NTS
Office of Construction and Facilities Management
BED
CLC
SICU
LAUNDRY
PARKING
GENERATORS
IWC
TWR
OPA
BLDG-1
ADMIN
CD (100%CD) FINAL BID DOCUMENTS – 03/14/2025
ARCHITECT/ENGINEER OF RECORD
A/E:
JUPITER
561-743-0165
ORLANDO
407-845-6630
WWW.RGDENGINEERS.COM
CERT OF AUTH 5454
121 S. ORANGE AVENUE, UNIT 1230N, ORLANDO, FL 32801
RGD PROJECT
#23-1050
8600 Indian Hills Dr Omaha, NE 68114 Tel 402.391.8111 Fax 402.391.8564
/1
/2
:2
:1
P
M
10 Calle Casia San Juan Puerto Rico 00921
ENLARGED DEMOLITION PLANS -
CLC LEVEL 1 AND 2
AD102C
Construct VA Bariatric Bathrooms at Community Center and South Bed Tower
003-10296-000
03/14/2025 RAD WMB
A u to d e s k D o c s /V
A C o n s tr u c t B a ri a tr ic B a th ro o m s a t C
L C
S
B T
R
V
A S
J B
A R
-A rc h it e c tu re .r v t
100% CD - FINAL BID
DOCUMENTS
SCALE: 1/8" = 1'-0"
B3
ENLARGED DEMOLITION PLAN - CLC LEVEL 1 AREA B
SCALE: 1/8" = 1'-0"
B5
ENLARGED DEMOLITION PLAN - CLC LEVEL 1 AREA C
SCALE: 1/8" = 1'-0"
B1
ENLARGED DEMOLITION PLAN - CLC LEVEL 1 AREA A
SCALE: 1/8" = 1'-0"
D1
ENLARGED DEMOLITION PLAN - CLC LEVEL 2 AREA A
SCALE: 1/8" = 1'-0"
D3
ENLARGED DEMOLITION PLAN - CLC LEVEL 2 AREA B
SCALE: 1/8" = 1'-0"
D5
ENLARGED DEMOLITION PLAN - CLC LEVEL 2 AREA C
4'
SCALE : 1/8" = 1'-0"
0 8' 16'
S I D E W A L K
PATIENT RM
IA-118
IA-117
IB-128IB-127
IB-126
IB-134IB-135IB-136IB-137IB-138IB-139IB-140
IB-142
IC-143
IC-150
IC-151
IC-152
IC-153
IC-155
IC-154
IC-1A
IA-119
IA-120
IA-121
IA-122
IA-123
IA-124
IB-125
IA-111
IA-110
IA-108
IC-157
IC-156
IC-156a
IA-100
IA-106
IA-104
IC-158
CI-1A
IC-159
IA-107 IA-109
IA-105
IC-144
IB-141
FUT. ELEV.
S-3
S-2
S-1
PATIENT RM
UP
STAIR #3
PATIENT RM
PATIENT RM
TLT
PATIENT RM
TLT
EXAM
W. SUPPLY
N. CALL
RES. LOUNGE
SOCIAL WK.
OFFICE
PATIENT
TLT
STG.
TLT
LOBBY
EQ. STG.
LAUNDRY
CORRIDOR
TLT QUIET
NURSES CLO.
KITCHEN
NURS.
HAC
TLT
CL. LINEN
CONG. BATH
STAIR #1
PATIENT RM
PATIENT RM
PATIENT RM
TLT
PATIENT RM
PATIENT RMPATIENT RM
TLT
STAIR
#2
PATIENT RM
TLT
PATIENT RMPATIENT RMPATIENT RM
STAFF
TLT
TLT
TLT
MACH. ROOM
ELEVATOR
ADMINISTRATIVE
OFFICES
LIVING CENTER
COMMUNITY
STG.
OFFICE
SUPERVISOR
NURSE
MEDIC
& CLERK
STATION
NURSE
BATH
ROOM
SOIL UTILITY
TLTTLT
TLT
TLT
PATIENT RM
PATIENT RM
TLT
PATIENT RM
IA-103
STAIR #3
#2
S-3
2A-107
2A-105
2C-156a
2C-156 2A-100
C2-1B
2B-1342B-1352B-136
2A-118
2A-119
2A-120
2A-117
2A-116
2A-121
2A-122
2B-127 2B-128
2B-1372B-1382B-139
2A-123
2B-125
2A-124
2A-111
2A-108
2A-110
2B-126
2B-142
2C-144
2B-141
C2-1A
2C-159
2C-158
2C-154
C2-1A
2C-157
2C-155
2A-109
2B-140
2C-143
2A-106
2C-149
2C-153
2C-152
2C-151
2C-150
PATIENT RM
PATIENT RM
TLT
PATIENT RM
PATIENT RM
TLT
PATIENT RM
PATIENT
TLT
THERAPY
EQ. STG.
QUIET
PATIENT RM
SOCIAL WK.
OFFICE
N. CALL
LAUND.
CORR.
W. SUPPLY
MEDIC
& CLERK
NURSE STATION
BATH
STAFF TLT
ROOM
SOIL UTILITY
BATH
NURSE
OFFICE
EXAM
MACHINE
TLT
NURSES CLO.
CL. LINEN
CONG. BATH
PATIENT RM
TLT
PATIENT RM PATIENT RM
PATIENT RM
STAIR #1
PATIENT RM
TLT
PATIENT RM
PATIENT RM
PATIENT RM
TLT
PATIENT RM
PATIENT RM
PATIENT RM
PATIENT RM
TLT
PATIENT RM
TLT
STAIR
TERRACE
LAUNDRY
FUT. ELEV.
RES. LOUNGE
PATIENT
TLT
PRIMARY CARE
HOME BASE SOCIAL
WORK
RECREATION
OFFICE
ICE
CORRIDOR
PATIENT RM
TLT
TLT
TLT
TLT
UP
AE410C
C1
AE410C
F1
AE410C
F5
339 SF
BARIATRIC PAT
RM
1A-113
232 SF
PAT RM
1A-112
372 SF
BARIATRIC PAT
RM
1B-130
373 SF
BARIATRIC PAT
RM
1C-147
231 SF
PAT RM
1C-146
242 SF
PAT RM
1C-145
183 SF
PAT RM
1C-149
236 SF
PAT RM
1B-131
CORRIDOR
C1-3WB-7
CORRIDOR
C1-2WA-6
CORRIDOR
C1-4WB-8
100'-0"
AREA A
AREA B
AREA B
AREA C
S T U V WS1 U2 X Y Z
R
225 SF
PAT RM
1A-114
183 SF
PAT RM
1A-116
232 SF
PAT RM
1B-129
255 SF
PATIENT RM
1B-133
AE411C
C1
AE411C
F1
AE411C
F5
375 SF
BARIATRIC PAT
RM
2B-130
235 SF
PAT RM
2B-131
255 SF
PAT RM
2B-133
231 SF
PAT RM
2B-129
223 SF
PAT RM
2A-114
183 SF
PAT RM
2A-116
230 SF
PAT RM
2A-112
232 SF
PAT RM
2C-146
370 SF
BARIATRIC PAT
RM
2C-147
41 SF
PAT TLT
2C-145A
182 SF
PAT RM
2C-149
241 SF
PAT RM
2C-145
CORRIDOR
C2-2WA-1
CORRIDOR
C2-3WB-2
CORRIDOR
2C-4WC-3
114'-0"
AREA A
AREA B
AREA B
AREA C
S T U V WS1 U2 X Y Z
R
NON-RATED FIRE PARTITION. PARTITION IS A
BARRIER TO LIMIT THE TRANSFER OF SMOKE
OVERALL FLOOR PLAN LEGEND
NTRUE
NORTH
REVISIONS
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
STAMPCONSULTANT
321 4 5 6 7 8 9 10
672-23-104
LAD NO.
KEY PLAN NTS
Office of Construction and Facilities Management
BED
CLC
SICU
LAUNDRY
PARKING
GENERATORS
IWC
TWR
OPA
BLDG-1
ADMIN
CD (100%CD) FINAL BID DOCUMENTS – 03/14/2025
ARCHITECT/ENGINEER OF RECORD
A/E:
JUPITER
561-743-0165
ORLANDO
407-845-6630
WWW.RGDENGINEERS.COM
CERT OF AUTH 5454
121 S. ORANGE AVENUE, UNIT 1230N, ORLANDO, FL 32801
RGD PROJECT
#23-1050
8600 Indian Hills Dr Omaha, NE 68114 Tel 402.391.8111 Fax 402.391.8564
/1
/2
:2
:2
P
M
10 Calle Casia San Juan Puerto Rico 00921
FLOOR PLANS - CLC LEVEL 1
AND 2
AE101C
Construct VA Bariatric Bathrooms at Community Center and South Bed Tower
003-10296-000
03/14/2025 RAD WMB
A u to d e s k D o c s /V
A C o n s tr u c t B a ri a tr ic B a th ro o m s a t C
L C
S
B T
R
V
A S
J B
A R
-A rc h it e c tu re .r v t
100% CD - FINAL BID
DOCUMENTS
SCALE: 1/16" = 1'-0"
F1
FLOOR PLAN - CLC LEVEL 1
SCALE: 1/16" = 1'-0"
F5
FLOOR PLAN - CLC LEVEL 2
8'
SCALE : 1/16" = 1'-0"
0 16' 32'
CLC CONSTRUCTION TYPE (IBC):
BUILDING TYPE 1B
PRIMARY STRUCTURAL FRAME: 2 HOURS
INTERIOR BEARING WALLS: 2 HOURS
NONBEARING INTERIOR WALLS: 0
FLOORS: 2 HOURS
ROOF: 1 HOUR
PAT TLT
1A-114A
BARIATRIC PAT TLT
1A-113A
BARIATRIC PAT RM
1A-113
PAT RM
1A-112
PAT RM
1A-114
EXTEND EXISTING
CEILING AS REQ'D
FOR NEW WORK
EXISTING CEILING
TO REMAIN
9'-0"
9'-0"
9'-0"
EXISTING CEILING
PATCH/ PAINT/
REPAIR CEILING/
WALLS/ FLOORING
AS NEEDED TO
MATCH EXISTING
OR ADJACENT
SURFACE, TYP
A1203
A1203
EXISTING WALL, TYP
A5180
U5170
SHOWER CURTAIN
TRACK, TYP
AE420A7
AE420
C3
AE420
A1
A3
A5
C7 C1
B1
B5
C5
PAT TLT
1A-114A
TLTS2
BARIATRIC PAT TLT
1A-113A
TSPB1
BARIATRIC PAT RM
1A-113
BRBA1
PAT RM
1A-112
PAT TLT
1A-116A
CORRIDOR
C1-2WA-6
1A-114A
1A-113
PAT RM
1A-114
6 5/8" 9'-5 3/8" +/- 1'-7 1/2" 6'-10"
7' -6
2"
'-2
AE410C
D4
PAT RM
1A-116
6'-1" 4' -1
4"
3'-1"
SODA
SA
MASONRY W/ PLASTER
WALL INFILL TO MATCH
EXISTING, TYP
CLOSE EXISTING
WINDOW BLINDS
PRIOR TO
INSTALLING WALL
S6OC
MASONRY AND PLASTER WALL
INFILL. PATCH AS REQUIRED TO
MATCH ADJACENT CONDITIONS,
TYP.
7'-6" 7'-6"
CLEARANCE FROM BED
SHOWN DASHED
AE420
D1
SEE ENLARGED CEILING
PLAN - CLC LEVEL 1 AREA
A FOR CEILING PLAN THIS
AREA
WARDROBE NIC
WARDROBE NIC
1A -1
A
A1203
A5115
P9050
A5115
P3100 A5115
P9056
A5115
C04Q0/CT020
A1203
P5040
C04Q0/CT020
P3005
U0043
U0047
A5080
A5075
A5205
A5145
A1066
A5080 A1066 A5075
A5080
A1066
A5075
A5075 A1066 A5080
FAN COIL UNIT, SEE
MECHANICAL
NEW SILL ON
EXISTING PARTIAL
HEIGHT WALL
NEW SILL ON
EXISTING PARTIAL
HEIGHT WALL
REINSTALL SALVAGED
ROOM SIGNAGE AND
SHADOW BOXES WHERE
OCCURS. COORDINATE
WITH COR
U0043
S6A
EXISTING WALL, TYP
B5
AE450
AE450
B9
F0265
M7040
M7009 F0350
A5180
NEW SILL ON
EXISTING PARTIAL
HEIGHT WALL @
PAT RM 1A-114 AND
2A-114 ONLY
NEW SILL ON
EXISTING PARTIAL
HEIGHT WALL
F0400
REWORK EXISTING/PROVIDE NEW
CRASH RAIL AND BUMPER AS
REQUIRED FOR WORK. MATCH
EXISTING PROFILES. TYPICAL AT
CORRIDORS AT AREAS OF WORK
U5170
A5077
F2000 F2000
M0505
B7
AE450
B6
AE450
M0750
FACE OF GWB
2'-1"
B7
AE450
EXISTING FCU
RUBBER BASE TO MATCH
EXISTINGAT NEW WORK
STL TUBE,
TYP. SEE STR
M0755 M0765
'-6
2'
-0
U0047
BARIATRIC PAT RM
1B-130
BRBA1
BARIATRIC PAT TLT
1B-130A
TSPB1
PAT TLT
1B-131A
TLTS2
PAT RM
1B-129
PAT TLT
1B-133A
PAT RM
1B-131
CORRIDOR
C1-3WB-7
1B -1
A
1B-130A
1B -1
X Y
AE420
A7
A1
A3
A5
AE420
B1
B5
AE420 C5
C1
C7
C3
SEE ENLARGED FLOOR PLAN - CLC
LEVEL 1 AREA A, (ROTATED 90°), FOR
TYPICAL NOTES AND EQUIPMENT
THESE ROOMS
7'-6"
SOC
AE450
F1
9' -7
/8
1'
-5
6' -1
0"
SEE ENLARGED CEILING PLAN - CLC
LEVEL 1 AREA B, FOR CEILING PLAN
THIS AREA
MASONRY AND PLASTER WALL
INFILL. PATCH AS REQUIRED TO
MATCH ADJACENT CONDITIONS,
TYP.
FACE OF
GWB
BARIATRIC PAT RM
1B-130
PAT TLT
1B-131A
BARIATRIC PAT TLT
1B-130A
PAT RM
1B-129
PAT RM
1B-131
X Y
CORRIDOR
C1-3WB-7
EXISTING
CEILING
9'-0"
9'-0"
9'-0"
A1203
A1203
U5170
A5180
PAT RM
1C-146
PAT TLT
1C-146A
TLTS2
BARIATRIC PAT TLT
1C-147A
TSPB1
BARIATRIC PAT RM
1C-147
BRBA1
PAT RM
1C-149
PAT TLT
1C-145A
PAT RM
1C-145
CORRIDOR
C1-4WB-8
1C-146A
1C-147
1C -1
A
6'-10" 1'-5" 9'-7 7/8" +/- 6 5/8"
7' -6
AE420
A1
A7
AE420
B5
B1 AE420
C5
C7C1
C3
A5
A3
6'-1"
S6A
SODA
S6OC
EXISTING WALL
SOC
7'-6" 7'-6"
REV
REV
REV
REV
REV
REV
REV
REV
REV
REV
SEE ENLARGED CEILING
PLAN - CLC LEVEL 1 AREA
C FOR CEILING PLAN THIS
AREA,
AE450
F1
SIM
SEE ENLARGED FLOOR
PLAN - CLC LEVEL 1 AREA
A, (REVERSE), FOR
TYPICAL NOTES AND
EQUIPMENT THESE
ROOMS
MASONRY AND PLASTER
WALL INFILL. PATCH AS
REQUIRED TO MATCH
ADJACENT CONDITIONS, TYP.
1'-1"
FACE OF GWB
PAT RM
1C-146
PAT TLT
1C-146A
BARIATRIC PAT TLT
1C-147A
BARIATRIC PAT RM
1C-147
PAT RM
1C-149
EXISTING
CEILING
EXISTING
CEILING
9'-0"
9'-0"
9'-0"
A5180
EXISTING WALL, TYP
A1203
A1203
U5170
EXISTING
CEILING
PAT TLTBARIATRIC PAT TLT
1' -4
1' -4
1' -6
1'
-3
1' -3
1'
-9
TYPICAL DIMENSIONS FROM
WALLS TO FIXTURES. SEE ALSO
SHEET GI003
1' -6
S
LO
P E
1/ 8"
/1 2"
FLOOR DRAIN, TYP.
1' -1
1/
2"
EQ EQ
1' -1
1/
2" E
Q E
Q E
Q
S
LO
/1 2"
S
LO
/1 2"
S
LO
/1 2"
S
LO
/1 2"
S
LO
/1 2"
2'-0"
EQ EQ
3' -0
1. SEE INTERIORS DRAWINGS FOR FINISH FLOOR PLANS
2. GRAB BARS, SINKS, TOILET, AND PATIENT LIFT LOCATED IN BARIATRIC PATIENT
ROOMS AND TOILETS ARE TO BE ABLE TO SUPPORT 1000 POUNDS MINIMUM.
GENERAL NOTES ARCHITECTURAL
CC = GENERAL CONTRACTOR FURNISHED AND GENERAL CONTRACTOR INSTALLED
(EQUIPMENT IS PURCHASED AND INSTALLED BY THE GENERAL CONTRACTOR)
VV = GOVERNMENT FURNISHED AND GOVERNMENT INSTALLED (EQUIPMENT IS
PROVIDED AND INSTALLED BY THE GOVERNMENT / EQUIPMENT VENDOR OR AGENT /
IOT CONTRACTOR)
GENERAL CONTRACTOR NOT RESPONSIBLE FOR PROCUREMENT AND INSTALLATION
OF ACQUISITION CODE VV EQUIPMENT. GENERAL CONTRACTOR AND GOVERNMENT /
EQUIPMENT VENDOR OR AGENT / IOT CONTRACTOR TO COORDINATE SCHEDULES FOR
INSTALLATION OF EQUIPMENT.
ACQUISITION CODE - CC
ACQUISITION CODE - VV
ACQUISITION CODE LEGEND
REFLECTED CEILING LEGEND
NOTE:
1. SEE ELECTRICAL FOR LIGHTING FIXTURE TYPES.
2. SEE MECHANICAL FOR AIR DEVICES.
3. COORDINATE SPRINKLER HEAD LOCATIONS WITH CEILING ITEMS SHOWN.
RECTANGULAR LUMINAIRE
ROUND LUMINAIRE
MECH SUPPLY AIR DIFFUSER
MECH RETURN AIR DIFFUSER
ACCOUSTICAL CEILING PANEL OR TILE SYSTEM
GYPSUM BOARD CEILING SYSTEM
NTRUE
NORTH
REVISIONS
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
STAMPCONSULTANT
321 4 5 6 7 8 9 10
672-23-104
LAD NO.
KEY PLAN NTS
Office of Construction and Facilities Management
BED
CLC
SICU
LAUNDRY
PARKING
GENERATORS
IWC
TWR
OPA
BLDG-1
ADMIN
CD (100%CD) FINAL BID DOCUMENTS – 03/14/2025
ARCHITECT/ENGINEER OF RECORD
A/E:
JUPITER
561-743-0165
ORLANDO
407-845-6630
WWW.RGDENGINEERS.COM
CERT OF AUTH 5454
121 S. ORANGE AVENUE, UNIT 1230N, ORLANDO, FL 32801
RGD PROJECT
#23-1050
8600 Indian Hills Dr Omaha, NE 68114 Tel 402.391.8111 Fax 402.391.8564
/1
/2
:2
:2
P
M
10 Calle Casia San Juan Puerto Rico 00921
ENLARGED FLOOR PLANS - CLC
LEVEL 1
AE410C
Construct VA Bariatric Bathrooms at Community Center and South Bed Tower
003-10296-000
03/14/2025 RAD WMB
A u to d e s k D o c s /V
A C o n s tr u c t B a ri a tr ic B a th ro o m s a t C
L C
S
B T
R
V
A S
J B
A R
-A rc h it e c tu re .r v t
100% CD - FINAL BID
DOCUMENTS
SCALE: 1/4" = 1'-0"
F3
ENLARGED CEILING PLAN - CLC LEVEL 1 AREA A
SCALE: 1/4" = 1'-0"
F1
ENLARGED FLOOR PLAN - CLC LEVEL 1 AREA A
FURNITURE & EQUIPMENT SCHEDULE TYP CLC BRBA1
JSN JSN_Name ACQUISITION CODE
A1015 TELEPHONE, DESK, MULTIPLE LINE CC
A1066 MIRROR, FLOAT GLASS, WITH SS FRAME CC
A1203 LIFT SYSTEM, OVERHEAD, BARIATRIC CC
A5075 DISPENSER, SOAP, DISPOSABLE CC
A5077 SOAP DISPENSER, SURFACE MOUNTED CC
A5080 PAPER TOWEL DISPENSER, SURFACE-MOUNTED CC
A5180 TRACK, CUBICLE, SURFACE MOUNTED, WITH CURTAIN VV
CT020/C04Q0 SOLID SURFACE COUNTERTOP WITH CABINET CC
F0265 CHAIR, RECLINER VV
F0350 STOOL, STEP, RETRACTABLE CASTER VV
F0400 CABINET, BEDSIDE, DOOR, DRAWER VV
M0505 TELEVISION, COLOR, BEDSIDE VV
M0750 FLOWMETER, AIR, CONNECT W/ 50 PSI SUPPLY VV
M0755 FLOWMETER, OXYGEN, LOW FLOW VV
M0765 REGULATOR, VACUUM VV
M7009 BED, PATIENT, ELECTRIC, SPECIAL CARE, BARIATRIC VV
M7040 TABLE, OVERBED CC
FURNITURE & EQUIPMENT SCHEDULE TYP CLC TSPB1
JSN JSN_Name ACQUISITION CODE
A1066 MIRROR, FLOAT GLASS, WITH SS FRAME CC
A1203 LIFT SYSTEM, OVERHEAD, BARIATRIC CC
A5075 DISPENSER, SOAP, DISPOSABLE CC
A5080 PAPER TOWEL DISPENSER, SURFACE-MOUNTED CC
A5115 GRAB BAR, FLIP-UP HEAVY DUTY CC
A5145 HOOK, GARMENT, DOUBLE, SS, SURFACE MOUNTED CC
A5205 BAR, TOWEL, 1" DIAMETER, SS, SURFACE MOUNTED CC
F2000 WASTEBASKET, ROUND, FIRE RESISTANT VV
P3005 LAVATORY, VITREOUS CHINA, BARIATRIC CC
P5040 SHOWER, SINGLE, HAND-HELD CC
P9056 TOILET, FLOOR MOUNTED, BARIATRIC CC
U0043 GRAB BAR, 36" CC
U0047 GRAB BAR, 24", VERTICAL CC
U5170 PATIENT LIFT SHOWER CURTAIN VV
2'
SCALE : 1/4" = 1'-0"
0 4' 8'
SCALE: 1/4" = 1'-0"
C1
ENLARGED FLOOR PLAN - CLC LEVEL 1 AREA B
SCALE: 1/4" = 1'-0"
C5
ENLARGED CEILING PLAN - CLC LEVEL 1 AREA B
SCALE: 1/4" = 1'-0"
F5
ENLARGED FLOOR PLAN - CLC LEVEL 1 AREA C
SCALE: 1/4" = 1'-0"
F7
ENLARGED CEILING PLAN - CLC LEVEL 1 AREA C
SCALE: 1/4" = 1'-0"
D4
ENLARGED TOILET PLAN CLC - FIXTURE LOCATIONS
FURNITURE & EQUIPMENT SCHEDULE CLC TLTS2
JSN JSN_Name ACQUISITION CODE
A1066 MIRROR, FLOAT GLASS, WITH SS FRAME CC
A5075 DISPENSER, SOAP, DISPOSABLE CC
A5080 PAPER TOWEL DISPENSER, SURFACE-MOUNTED CC
A5115 GRAB BAR, FLIP-UP HEAVY DUTY CC
F2000 WASTEBASKET, ROUND, FIRE RESISTANT VV
P3100 LAVATORY, VITREOUS CHINA, SLAB TYPE CC
P9050 TOILET, WALL HUNG, SIPHON JET CC
PAT RM
2A-114
BARIATRIC PAT TLT
2A-113A
TSPB1
PAT TLT
2A-114A
TLTS2
PAT RM
2A-112
PAT RM
2A-116
PAT TLT
2A-116A
CORRIDOR
C2-2WA-1
2A-114A
2A -1
A
2A-113
AE420B1
B5
AE420 C1
C3
C7
C5
AE420A7
A1
A3
A5
BARIATRIC PAT RM
2A-113
BRBA1
SO
SEE ENLARGED FLOOR PLAN -
CLC LEVEL 1 AREA A, SHEET
AE410C, FOR TYPICAL NOTES
AND EQUIPMENT FOR CLC
LEVEL 2 AREA A
AE420
D1
AE450
B9
MASONRY AND PLASTER WALL
INFILL. PATCH AS REQUIRED TO
MATCH ADJACENT CONDITIONS,
TYP.
7' -6
2"
1'-5" 6'-10"
FACE OF GWB
B7
AE450
SEE ENLARGED CEILING PLAN - CLC
LEVEL 2 AREA A, FOR CEILING PLAN
THIS AREA
PAT RM
2A-114
BARIATRIC PAT TLT
2A-113A
PAT TLT
2A-114A
PAT RM
2A-112
BARIATRIC PAT RM
2A-113
9'-0"
9'-0"
9'-0"
A1203
A5180
A1203
U5170
EXTEND…