RTE KME.DQ-040-22 (Complete).pdf

PDF 257 KB Posted

Attached to
Level I Pipe Federal contract opportunity
Solicitation number
SPMYM3-22-Q-7017
Issued by
Defense Logistics Agency Land and Maritime

View the file

Other files for this federal contract opportunity

Other files attached to Level I Pipe, newest first.
File Type Posted
RTE KME.DQ-046-22 (Complete).pdf PDF
RTE KME.DQ-043-22-(complete).pdf PDF
RTE KME.DQ-036-22 (Complete).pdf PDF
LL-DA1-1421 L1 (07-01-21) Complete.pdf PDF
22-Q-7017 released close Feb 23.pdf PDF
Amendment closing date Feb 23.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

REQUEST FOR TECHNICAL EVALUATION (RTE)

NAVSHIPYD PTSMH 4840/9 (NEW 1-18)

1. RTE serial No. 2. Date 3. Contract/Solicitation No. 4. CLIN 5. Hull 6. Job Order No.

7. QA Level 8. Value $ 9. Document No. 10. Delivery Date

11. Material Description

12. Deviation 12A Non-Conformance

Not a Deviation

Major Minor Not Required

Required

Deviation Not Acceptable Deviation Acceptable

NC Number Required

13. Prime Vendor/Subcontractor 13A Sub-Vendor/Contractor

14. Heat No. 15. RT Serial No. 16. Brief Description of Deviation

17. Technical Evaluation – Approve/Disapprove/Evaluator Comments; (As Applicable, include: noun name, ID Number, & Rev of Procedure or Document Being Evaluated, RSS #, NDT Method Spec, Fabrication Spec, etc.)

18. Price Justification Will Deviation Result in Increased Cost to the Government? Yes No N/A

Will Deviation Result in Decreased Cost to the Contractor? Yes No N/A

18A. This is _______________________________________________________ Vendor Deviation on this contract

19. Approved Yes No (See Comments/Reasons in Block 17)

NOTE: Any approvals are applicable to this contract and for the application and/or item(s) specified.

19A. Approver – Print/Sign/Code/Date

19B. Overview – (As Applicable) – Print/Sign/Code/Date

20. Authorized Representative (Code 138 Division Head/Contracting Officer) (As applicable- Print/Sign/Date)

Mod will be issued Mod will not be issued

Distribution: 133.2, 135T, 135.3, 136.2, 245.3

REQUEST FOR TECHNICAL EVALUATION (RTE) (Back)

NAVSHIPYD-PTSMH-4840/9 (NEW 1/18)

Code 503/410:

A. Non-iRAPT Only: Form will be initiated by contracting who will complete the following blocks:

1 through 11, 13, and 13A.

NOTE: Block 20 is to be utilized by the contracting officer for review and determination of need for contract modification

Technical Codes (135T, 135.3, 138.2, 245.3)

Blocks 12, 12A, 17, 18 and 19 will be completed by cognizant technical codes.

1 This is a code generated sequential unique serial number; serial number will be formatted as follows: Code-First Last Name Initials-Sequential # from Serial Number Log-Calendar Year, e.g. 503.DQ-108-17.

12 A deviation is a change from the contract, requested by the contractor. Interpretations or corrections of the contract are not deviations. Definitions of major and minor are in Process Instruction 7650-801-367.

12A If required technical code to issue non-conformance in accordance with Process Instruction 7650-801-367 17 Provide technical evaluation and rationale for approval/disapproval. Block 17 must contain all applicable and pertinent information as deemed necessary or required.

18 Complete only if deviation 20 Block 20 is to be utilized by the NAVSEA Authorized Representative for weld procedure approval only

B. iRAPT Only: Initiate form per applicable appendix when an item has been entered in the iRAPT system. Complete the following blocks (use guidelines above for Blocks 1, 12, 12A, 17, 18 & 20):

Code 135T complete To:/From:, & blocks 1 ,2, 3, 4, 7, 11, 13, 13A, 17, 19 & 19A

Code 135.3 complete To:/From:, & blocks 1, 2, 3, 4, 7, 11, 13, 13A, 14, 15, 17, 19, & 19A

Code 138.2 complete To:/From, & blocks 1, 2, 3, 4, 7, 11, 13, 13A, 14, 15, 17, 19, 19A, 19B, & 20 (NOTE: Block 20 is to be utilized by the NAVSEA Authorized Representative for weld procedure approval only)

Code 245.3 complete To:/From, & blocks 1, 2, 3, 4, 5, 6, 7, 8, 9, 11, 12, 12A, 16, 17 18, 18A 19A, 19B.

REQUEST FOR TECHNICAL EVALUATION (RTE) (Continuation Sheet)

NAVSHIPYD-PTSMH-4840/9 (NEW 1/18)

RTE Serial Number _______________________

Continuation Sheet. Where space provided is not sufficient, use additional sheets identified by serial number (see

Block 1) and applicable block numbers.

2 Date: 02/01/2022
3 ContractSolicitation No: SPMYM322Q7017
4 CLIN: 0001
5 Hull: 772
6 Job Order No: 3897252901 R12
8 Value:
9 Document No: 13503633
10 Delivery Date:
11 Material Description: Level I pipe
13 Prime VendorSubcontractor: TBD
13A SubVendorContractor:
14 Heat No:
15 RT Serial No:
16 Brief Description of Deviation: Vendor can only offer +15% - 0% wall tolerance. Is this acceptable? Please advise.
17 Technical Evaluation ApproveDisapproveEvaluator Comments As Applicable include noun name ID Number Rev of Procedure or Document Being Evaluated RSS NDT Method Spec Fabrication Spec etc: Wall tolerance for MOD of +15/-0% for 0.400" min wall thickness is acceptable.
18A This is:
Continuation Sheet Where space provided is not sufficient use additional sheets identified by serial number see Block 1 and applicable block numbersRow1:
QA Level: [1]
2022-02-04T09:49:45-0500
GENDREAU.MATTHEW.A.1395863955
2022-02-04T10:01:28-0500
HARMON.STEVEN.W.1289406219
1 RTE serial No: KME.DQ-036-22
Text6:
Group2: Off
Group3: Off
Group4: Off
Group5: Choice2
Group6: Choice2
Group7: Choice1
Group8: Off

File details come from the government source that posted it. Updated .