RSS Beam Stop-Min Specs.pdf
PDF 173 KB Posted
- Attached to
- Radiation Safety System Beam Stop Assemblies
- Solicitation number
- TC0075-51624
- Issued by
- Whitman County, Washington
About this file
This document is a bid invitation for five Radiation Safety System (RSS) Beam Stop Assemblies to be used at the Dynamic Compression Sector (DCS) located at the Advanced Photon Source (APS), Argonne National Laboratory (ANL) in Lemont, Illinois. The assemblies must meet detailed technical specifications outlined in the attached drawings, including requirements for welding, brazing, and ultra-high vacuum cleaning. No alternatives or substitutions will be accepted, and lead time will be a determining factor in vendor selection. Shipping terms are FOB Destination or FOB Origin/Ex Works with insurance, and the procuring agency is Washington State University.
The bid invitation includes a vendor list with contact information for potential suppliers, but does not specify any set-asides, incumbents, or funding sources. Pricing terms require a formal quote listing lead time and estimated insured shipping costs. The bid is for a one-time purchase, with no mention of contract renewal options.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| RFP #TC0075-51624 Beam Stop Assemblies.xlsx | XLSX spreadsheet | |
| WSU Certification Assurances Form.pdf | ||
| RSS Beam Stop Assy Dwgs.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
BID: RSS BEAM STOP ASSEMBLIES
Please provide a formal quote listing lead time and include a separate line item for estimated insured shipping costs.
PURPOSE
Procure five (5) Radiation Safety System (RSS) Beam Stop Assemblies to be used at the Dynamic Compression Sector (DCS) located at the Advanced Photon Source (APS), Argonne National Laboratory (ANL) in Lemont, IL.
The final product must meet the specifications described in the attached drawings. These RSS beam stop assemblies will be used under vacuum to detect potential X-Ray misalignment from a theoretical pin hole caused by the X-Ray burning through the copper face.
RSS BEAM STOP ASSEMBLIES’ SPECIFICATIONS
Detailed specifications for the Fuses are listed below. Note that leak checks, with supporting documentation, are required of each assembly:
• Quantity Required: 5
• See attached file RSS Beam Stop Assy Dwgs.pdf for complete technical details.
o DCS RSS Beam Stop: Assembly, DCS-BS-01-001 o DCS RSS Beam Stop: Body, DCS-BS-02-001 o DCS RSS Beam Stop: Cover, DCS-BS-02-002
• Each component must include the required welding and brazing as specified in dwg DCS-BS-01-001.
• All fuses must adhere to the UHV Cleaning Standard detailed in Section 3.3 of the attached APS
Engineering Standard Document APS_2018473.pdf.
• Chambers must pump down to minimum 1 x 10 ^ - 9 Torr
OTHER DETERMINING FACTORS
• No alternatives or substitutions to specifications and tolerances listed herein will be accepted.
• Although not specified herein, lead time will be a determining factor in vendor selection.
• Shipping Terms:
o FOB Destination or o FOB Origin/Ex Works with insurance.
Bill To:
Washington State University PO Box 641025 Pullman, WA 99164-1025
Ship To:
Washington State University c/o Argonne National Lab 9700 S. Cass Ave, Bldg 438F/F001 Lemont, IL 60439 Attn: Liz Prokop, 630-252-9854
We are a tax-exempt organization per the attached State of Illinois Sales Tax Exemption Certificate ID No. E9924- 3431.
BID: RSS BEAM STOP ASSEMBLIES
VENDOR LIST
Eclipse Precision Machining, LLC.
1640 Jarvis Avenue Elk Grove Village, IL 60007 847-258-3774, https://eclipsepm.us/
David Golaszewski, Sales Dir: (847) 258-3774 david@eclipsepm.us
Argonne National Lab Central Shops 9700 S Cass Ave, Bldg 363 Lemont, IL 60439
Bill Toter, 630-252-7342, wtoter@anl.gov Mark Rooney, 630-252-6669, mrooney@anl.gov
NPB Technology Group, Inc.
1048 Irvine Ave #386 Newport Beach, CA 92660 949-945-3316; https://www.npbtech.com/
Corinne D’Ambrosio, 213.272.3864, corinne@npbtech.com
MDC Precision 30962 Santana Street Hayward, California 94544 1-800-443-8817, sales@mdcprecision.com
Amelita Camacho, Sales Admin, 510-265-3500 x 3527, ACamacho@mdcprecision.com
Vacuum One 3717 North Ravenswood, Suite 240 Chicago, IL 60613 773-244-3102, https://www.vacuumone.com/
Scott Dix, Ofc: 773-244-3102 / Cell: 773-294-8782 sdix@vacuumone.com
Ideal Vacuum 590 Midway Park Blvd NE Albuquerque, NM 87109 505-872-0037; http://www.idealvac.com info@idealvac.com
Juan Pedroza, 505-872-0037 x106, jp@idealvac.com
Nor-Cal Products, Inc dba Pfeiffer Vacuum Valves & Engineering 1967 South Oregon Street Yreka, CA 96097 800-824-4166, https://www.n-c.com/
Maureen Rosenwinkel, Midwest Sales Mgr: 312-636- 6738; mrosenwinkel@pfeiffer-vacuum.com
Jacob Falck, WI/IL Sales Engineer:414-305-2745 jacob.flack@pfeiffer-vacuum.com
Kurt J Lesker 1925 Route 51 Jefferson Hills, PA 15025 USA 800-245-1656, https://www.lesker.com/ sales@lesker.com
Matt Kelley, Acct Develop, mattk@lesker.com
Doug Childers, Regional Mgr, dougc@lesker.com https://eclipsepm.us/ mailto:david@eclipsepm.us mailto:wtoter@anl.gov mailto:mrooney@anl.gov https://www.npbtech.com/ mailto:corinne@npbtech.com mailto:sales@mdcprecision.com mailto:ACamacho@mdcprecision.com https://www.vacuumone.com/ mailto:sdix@vacuumone.com https://nam12.safelinks.protection.outlook.com/?url=https%3A%2F%2Furldefense.com%2Fv3%2F__http%3A%2F%2Fwww.idealvac.com%2F__%3B!!JmPEgBY0HMszNaDT!qd_fA3E1Ji_PUX-4v4DKFuJxiYFtB1y8oQ9gvqeRWCvPqSXV_-KSpqppOHVyhhSkkeFeLPWLrrwBuQ%24&data=05%7C02%7Cdcs.info%40wsu.edu%7Ce39a8b2e846348db4eb808dc226e26b8%7Cb52be471f7f147b4a8790c799bb53db5%7C0%7C0%7C638423103718634957%7CUnknown%7CTWFpbGZsb3d8eyJWIjoiMC4wLjAwMDAiLCJQIjoiV2luMzIiLCJBTiI6Ik1haWwiLCJXVCI6Mn0%3D%7C0%7C%7C%7C&sdata=H51CWwBVC3hVopc9WPogSpa%2FEiu28D8JedDbhRTRRbQ%3D&reserved=0 mailto:info@idealvac.com mailto:jp@idealvac.com https://www.n-c.com/ mailto:mrosenwinkel@pfeiffer-vacuum.com mailto:jacob.flack@pfeiffer-vacuum.com https://www.lesker.com/ mailto:sales@lesker.com mailto:mattk@lesker.com mailto:dougc@lesker.com
| Purpose |
| RSS BEAM STOP ASSEMBLIES’ SPECIFICATIONS |
| Other Determining Factors |
| Vendor List |
File details come from the government source that posted it. Updated .