GEIo- Attachment I.pdf

PDF 45 KB Posted

Attached to
New Reactor Control Room Simulator and Improving the General Electric Simulator Federal contract opportunity
Solicitation number
RS-38-10-702
Issued by
Nuclear Regulatory Commission Central Office

About this file

GE Simulator I/O System - Attachment I

View the file

Other files for this federal contract opportunity

Other files attached to New Reactor Control Room Simulator and Improving the General Electric Simulator, newest first.
File Type Posted
RS-38-10-702.doc DOC document
RS-38-10-702-Amendment No. 03.pdf PDF
CS_Information_Protection_Policy - Attachment II.pdf PDF
SF30-Amendment No. 02.PDF PDF
RulesOfBehavior - Attachment VII.pdf PDF
GESampleSubr- Attachment - VIII.pdf PDF
LaptopPolicy - attachment V.pdf PDF
NRC-Pwd-Warn-Banr-Guid-Attachment VI.pdf PDF
General_Laptop_Configuration_Std - Attachment IV.pdf PDF
DataAtRestEncryptionPolicy - Attachment III.pdf PDF
RS-38-10-702_GEQuestions12-15-2009.doc DOC document
RS-38-10-702-Amendment No. 01.pdf PDF
RS-38-10-702 Solicitation.PDF PDF
Show all 13

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

H S

D

H S

D

Master Controller

Master Controller

Subcontroller 5Subcontroller 4Subcontroller 3Subcontroller 2Subcontroller 1Subcontroller 0

Subcontroller 6Subcontroller 5Subcontroller 4Subcontroller 3Subcontroller 2Subcontroller 1Subcontroller 0

2 DI

5 RO/LO

1 DO

1 Analog

(10 AO)

(6 AI)

2 DI

4 RO/LO

0 DO

1 Analog

(14 AO)

(1 AI)

3 DI

2 RO/LO

1 DO

1 Analog

(10 AO)

(0 AI)

4 DI

3 RO/LO

3 DO

1 Analog

(12 AO)

(2 AI)

2 DI

3 RO/LO

1 DO

1 Analog

(8 AO)

(1 AI)

3 DI

3 RO/LO

0 DO

1 Analog

(12 AO)

(3 AI)

3 DI

4 RO/LO

0 DO

2 Analog

(16 AO)

(1 AI)

4 DI

5 RO/LO

0 DO

2 Analog

(30 AO)

(1 AI)

3 DI

5 RO/LO

1 DO

1 Analog

(14 AO)

(0 AI)

5 DI

8 RO/LO

0 DO

2 Analog

(28 AO)

(3 AI)

0 DI

6 RO/LO

0 DO

0 Analog

(0 AO)

(0 AI)

3 DI

5 RO/LO

0 DO

2 Analog

(24 AO)

(2 AI)

7 DI

7 RO/LO

1 DO

2 Analog

(24 AO)

(8 AI)

I/O Count per Chassis: DI = 18 words * 16/word = 288 per chassis RO/LO = 16 words * 16/word = 256 per chassis DO = 16 words * 16/word = 256 per chassis AO = 8 per card AI = 16 per card

Legend: HSD - High Speed Data interface DI - Digital input DO - Digital Output RO/LO - Relay Output/Lamp Output AI - Analog Input AO - Analog Output

GE Simulator I/O System

File details come from the government source that posted it. Updated .