Royal_Oak_Public_Library_Cameras_Final_Drawing_Package_OFB.pdf

PDF 4 MB Posted

Attached to
Royal Oak Public Library Camera Refresh
Solicitation number
RFP-RO-2024-015
Issued by
Oakland County, Michigan

About this file

The document is a detailed technical drawing package for the Royal Oak Public Library Camera Refresh project in Royal Oak, Michigan, prepared by Convergent Technology Partners. The project involves a comprehensive security camera system upgrade across the library's lower and main levels, with multiple camera locations strategically mapped on floor plans. The drawings specify 16-17 camera locations per floor, including mounting instructions for lay-in tile ceilings, hard ceilings, and external areas, with each camera to be connected via Category 6 cable from the Main Distribution Frame (MDF). Camera placements are designed to provide comprehensive coverage of library spaces, with specific mounting height requirements (typically 10 feet AFF - Above Finished Floor) and notes for weatherproofing external camera installations.

The technical drawings include detailed coverage maps showing camera positioning and viewing angles, color-coded to indicate different installation zones and camera locations. Each camera location is assigned a unique identifier (e.g., PL-CL-01, PL-ML-17) and accompanied by specific installation instructions. The project appears to be a technology infrastructure upgrade focused on enhancing security and surveillance capabilities, with careful consideration given to cable routing, mounting methods, and comprehensive space coverage. The drawings are prepared with precision, showing camera locations on both the lower and main levels of the library, and include notes about existing camera demolition and new installation requirements.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

PL-CL-01

PL-CL-02 PL-CL-03

PL-CL-04

PL-CL-15PL-CL-10

PL-CL-16

PL-CL-09

PL-CL-11

PL-CL-08

PL-CL-12

PL-CL-05

PL-CL-07

PL-CL-13

PL-CL-06 PL-CL-14

10 ft10 ft

MDF

LAY-IN CEILING

LAY-IN CEILING LAY-IN CEILING

LAY-IN CEILING

APPROXIMATE

LOCATION OF CHASE

TO MAIN LEVEL

HIGH, HARD

LAY-IN CEILING

1 1

NOTES:

1. PROVIDE ONE CATEGORY 6

CABLE TO EACH CAMERA

LOCATION FROM THE MDF ON

BOTH FLOORS. TERMINATE

CABLES WITH PLUGS AT THE

CAMERA AND ON A PATCH

PANEL IN THE MDF.

KEY NOTES:

MOUNT CAMERA ON LAYIN

TILE CEILING.

WALL MOUNT CAMERA AT 10'

AFF, FOR EXTERNAL CAMERA

PROVIDE CORING AS

NEEDED. WEATHER PROOF

CAMERA MOUNTS AND ALL

PATHWAY AND FITTINGS.

INSTALL CAMERA AT 10' AFF

USING POLE EXTENSION

FROM CEILING. PROVIDE

CONDUIT FROM CEILING

MOUNT TO LAY IN CEILING

AREA OR STORAGE AREA

CEILING.

EXISTING CAMERA AND CABLE -

DEMO

STORAGE

AREA

ROYAL OAK PUBLIC LIBRARY CAMERA REFRESH

CABLING AND CAMERA LOCATIONS

PL-CL-42

PL-CL-41

PL-ML-37

PL-ML-18 PL-ML-30

PL-ML-17 PL-ML-33

PL-ML-24

PL-ML-34

PL-ML-31

PL-ML-19

PL-ML-23

PL-ML-20

PL-ML-29

PL-ML-32

PL-ML-21

PL-ML-25 PL-ML-38

PL-ML-39

PL-ML-22

PL-ML28 PL-ML-36

PL-ML-26

PL-ML-27 PL-ML-35

PL-ML-40

10 ft10 ft

HIGH HARD

CEILING -

INACCESSIBLE

HARD

CEILING

HARD

CEILING

NOTES:

1. PROVIDE ONE CATEGORY 6

CABLE TO EACH CAMERA

LOCATION FROM THE MDF ON

BOTH FLOORS. TERMINATE

CABLES WITH PLUGS AT THE

CAMERA AND ON A PATCH

PANEL IN THE MDF.

2. WEATHER PROOF EXTERNAL

CAMERA MOUNTS AND ALL

PATHWAY AND FITTINGS.

KEY NOTES:

MOUNT CAMERA ON LAYIN

TILE CEILING USING

APPROPRIATE CEILING

SUPPORTS.

MOUNT CAMERA AT 10'

AFF, FOR EXTERNAL CAMERA

WALL MOUNT CAMERA AT 10' AFF,

FOR EXTERNAL CAMERA

PROVIDE CORING AS NEEDED.

SURFACE MOUNT CAMERA ON

UNDERSIDE OF WALKWAY

OVERHANG. REUSE EXISTING

PATHWAY OR PROVIDE CONDUIT

FROM INSIDE LAYIN CEILING

SPACE CEILING.

EXISTING CAMERA AND CABLE -

DEMO

ROYAL OAK PUBLIC LIBRARY CAMERA REFRESH

CABLING AND CAMERA LOCATIONS

PL-CL42

PL-CL-01

PL-CL-02 PL-CL-03

PL-CL-10 PL-CL-15

PL-CL-16

PL-CL-04

PL-CL-09

PL-CL-11

PL-CL-41

PL-CL-08

PL-CL-05

PL-CL-12

PL-CL-06

PL-CL-07

PL-CL-13

PL-CL-14

20 ft20 ft

Royal Oak Public Library Camera Lower Level Refresh Camera

Coverage

PL-CM-37

PL-CM-30PL-CM-18PL-CM-17 PL-CM-33

PL-CM-24

PL-CM-34

PL-CM-31

PL-CM-23

PL-CM-19

PL-CM-20

PL-CM-32

PL-CM-29

PL-CM-21

PL-CM-38

PL-CM-39

PL-CM-25

PL-CM-22

PL-CM-36

PL-CM-35

PL-CM-40PL-CM-26 PL-CM-28

PL-CM-27

10 ft10 ft

Royal Oak Public Library Camera Main Level Refresh Camera

Coverage

File details come from the government source that posted it. Updated .