VBA Design Guideline – September 2016

LESSOR: ________ GOVERNMENT: ________ Page 1

Design Criteria, Guideline and Minimum

Building and WorkSpace Requirements

Department of Veterans Affairs

Veterans Benefits Administration

Office of Facilities (OAF-20M30)

LESSOR: ________ GOVERNMENT: ________ Page 2

General Requirements:

• Veterans Benefits Administration (VBA) workspaces undergo many changes during their lifetime in order to provide better service to the Veterans. As Department of Veterans Administration (VA) mission and priorities change over time. As such, requirements for space and services change frequently, and space must be reconfigured often. The flexibility to accommodate continual change needs to be “built in” to the workspace design from the outset and respected in subsequent alterations.

• It is imperative that VBA facilities and workplaces be designed with the objective of achieving lowest life cycle cost for taxpayer while providing excellent service to our Veterans.

• VBA supports a workspace and interior design program that provides their employees with superior work environments that meet VBA business and mission goals and enhances health, satisfaction, and performance, reflecting VBA culture, motivation, business strategy and nature of their work.

• Each VBA building, workplace and space should be designed, realigned/renovated and constructed to the maximum extent feasible, to be in compliance with one of the nationally recognized and applicable building codes issued by the International Code Council (ICC).

• All new VBA spaces and facilities should be located in Class A government leased or owned buildings.

• The building and VBA space should be in full compliance with American Disability Act (ADA) requirements and codes.

• The building and facility must be fully equipped with approved automatic sprinkler system fire protection throughout and fire alarm control unit with less than 25 years old.

• The floor/s occupied and used by VBA must have ADA accessible rest rooms.

• The planning of VBA facilities should incorporate principles of sustainable design and energy efficiency into all of its buildings, floors and space of new or realigning the existing projects.

• All enclosed workplaces such as enclosed offices, conference rooms, training rooms and other such functions should be placed in the interior side of the floor allowing natural light to the open work and office area.

• The location and layout of the conference rooms should be considered as such so they can be shared with other groups and entities by providing doors from common areas such as corridors.

Acoustic Requirements:

• Space shall have wall construction with a minimum Sound Transmission Coefficient (STC) rating of 50. This quantifies the sound insulating performance of the building elements, such as walls.

• The Noise Insulation Class (NIC) which quantifies the field tested sound isolation between two enclosed spaces separated by a partition, should be as follow:

o Meeting, Hearing and Training Rooms 53 o Private Office 45 - 40

• The ceilings shall have equivalent sound barriers and /or extension of walls to the solid structure above (slab to slab).

• Mechanical and Electrical systems should also be designed and installed to reduce noise and prevent sound transmission.

LESSOR: ________ GOVERNMENT: ________ Page 3

ADA Push Button Hardware:

At least one ADA compliance push button door opener to be provided for a single occupied facility. This device should be located close to the card key access unit if applicable.

If the facility is on multiple floors, then there should be at least one entry to the open office space on each floor equipped with the ADA push button hardware, preferably on the door close to the common rest rooms on the floor, away from the doors which are kept in open position during business hours.

No such hardware is required for offices such as Public Contact, VR&E and VSO, which their entry doors are propped open during business hours.

Artworks:

If there is a desire or need for artworks other than First Impression, the following criteria has to be followed as bases for the selection and installation:

• All graphics and images to be framed the same size throughout

• All frames within the same office to be of the same material and color

• The frame thickness should not be more than 2 inches

• The theme of the art works to represent happy and joyful moments of veterans and not ammunition or war actions or sceneries

• The images respect all people, men and women, with every ethnic background

• Frames to be installed at eye height and not too low

• If possible, use non-glare glass

• When installing/hanging the frame, make sure that the hanger is placed on wall stud and is safety secured

• If the artwork is a large piece or if it contains any artifact, the wall should be prepared by installing plywood behind the drywall to receive the new frame.

Audio Visual Equipment:

This guide will provide the information needed to develop a turnkey Audio Visual (AV) system to include equipment, installation, and warranty.

All video conferencing equipment, including monitors, cameras and operating systems will be scheduled in-advance, procured, coordinated for installation and provided directly by the IT team and under the IT funds.

The areas receiving the audio visual capability are:

• Director’s Office o 42” Plasma LCD wall mounted monitor o Monitor manufacturer supplied remote control o Two computer connections for one each desktop and laptop o Cable connection o Optional:

• VCR/DVD combo unit

• Veterans Service Center (VSC) Workspace Area o 46” Plasma LCD wall mounted monitors

LESSOR: ________ GOVERNMENT: ________ Page 4 o Monitor manufacturer supplied remote control o No Audio is required

❖ These monitors should be located strategically throughout the space, visible to multiple sections of the staff and connected to a PC identified by the director or VSC chief to broadcast performance schedule of the RO via spreadsheets.

• Division Conference and Hearing Room o 42” – 47” Plasma LCD wall mounted monitor o Projectors are not recommended.

o Two computer connections for one each desktop and laptop o Monitor manufacturer supplied remote control o Audio reinforcement through monitor speakers. (Table Speakerphone-Requires analog phone line.)

o Optional:

• Wireless presentation pointer device

• Small (150 SF) and Medium (250 SF) Conference Rooms o No monitor or projector.

o Two computer connections for one each desktop and laptop o Optional:

• Large Conference Room 420 SF o 4000 lumen XGA for rooms with ambient light.

o Electric or fixed screen wall-mounted 84” to 100” diagonal.

o Two computer connections for one each desktop and laptop. AV, HDMI, and component connections recommended.

o Color touch-panel control system with user-friendly controls for all devices.

o Ceiling-mounted speakers. Sound distribution audio playback for video and computer sources. (Table Speakerphone-Requires analog phone line with connection to ceiling speakers - Single channel wireless mike.)

o Cabinet contains all system devices, free standing.

o Optional:

• Large Training Room Multi-Purpose Space o 4000 lumen XGA projector with ambient light.

o Electric screen wall-mounted 100” diagonal.

o Two computer connections for one each desktop and laptop. AV, HDMI, and component connections required.

o Color-touch panel control system with user-friendly controls for all devices (Optional:

Wireless).

o Ceiling-mounted speakers. Sound distribution audio playback for video and computer sources. (Table speakerphone-Requires analog phone line with connection to ceiling speakers - Single channel wireless mike.)

o AV closet / room o Optional:

• VCR/DVD combo unit

• Multifunction presentation pc

LESSOR: ________ GOVERNMENT: ________ Page 5

❖ Large conference rooms are often dividable into multiple sections using sound-isolating, moveable partitions. Each partitioned area can be equipped as a separate room as sized above; however, it is important that there is adequate sound insulation between each space.

❖ If the space includes multiple columns or odd shape space, there should be monitors, 42”+ in multiple locations to cover the visibility for the attendees and audiences.

Break Room, Pantry and Appliances:

In order to maintain work efficiency, each regional office may have a break room equipped with adequate appliances to serve employee’s need.

The following provides a guideline based on normal practices in current commercial and government facilities. These standards will be revised accordingly if any deficiencies found.

Break Room:

o A wet (with sink and cold/hot water lines) break room for a foot print of up to

20,000 SF of single floor space o An additional break room for every 10,000 SF of space there after o If a regional office is located in multiple floors, each floor to have a separate break room if the space on each floor is above 10,000 SF of space o Break room to be equipped with direct exhaust fan o Break room should have a door equipped with closer o Break room to have a minimum of 8 linear feet of cabinetry including overhead cabinets. All counter tops to be ADA compliance.

o There to be at least three drawers with cabinets o Break room to be equipped with direct exhaust fan o For every 50-75 employee:

• A full size Energy Star refrigerator/freezer, side by side, equipped with ice maker (water line to be provided). The icemakers may not be located in-the-door, nor may the refrigerator have water dispensing capabilities. (page 5, of the VA Financial Policy Volume V, Chapter 10B, 100502, A, B, C)

• Two full size microwave ovens with oven capability, one at ADA compliance height

• One coffee machine

• Two vending machines

• Three under counter recycling compartments for glass, cans, and trash

• Two round/square table for four with chairs

Pantry:

o Pantry should have at least 5 feet of cabinetry including overhead cabinets. All counter tops to be ADA compliance.

o A full size refrigerator equipped with ice maker (water line to be provided). The icemakers may not be located in-the-door, nor may the refrigerator have water dispensing capabilities. (page 5, of the VA Financial Policy Volume V, Chapter 10B, 100502, A, B, C) o A full size microwave ovens with oven capability, one at ADA compliance height o A full height under counter recycling compartment o Depending upon the location, pantry can be accessed via an adequate opening with no door

LESSOR: ________ GOVERNMENT: ________ Page 6

Elevator Requirements:

Vandal-resistant buttons, cab access hatch, keyed and operable from above (outside), recessed lighting with vandal-resistant lens, stop button inside cab with key lock and stop button override located at first floor panel. All elevator cabs, opening to VBA (full floor tenant) floors, where VBA is the only tenant, should be equipped with programmable Card Key access, per VA ID standards and security requirements. Please refer to the security section under this guideline.

Employee Parking:

As retrieved from the GAO website on 03 February 2012 at http://www.gao.gov/special.pubs/d04261sp.

pdf. Page 503.

This subject has been discussed in section C.13.j(1) of Chapter 4. As a result the parking related regulations have been selected below and summarized as follow:

Commuting and parking:

o Along with commuting goes parking. It is equally clear that parking incident to ordinary commuting is also a personal expense. 63 Comp. Gen. 270 (1984); 43 Comp.

Gen. 131 (1963); B-162021, July 6, 1977.

o However, an agency may provide employee parking facilities if it determines that the lack of parking facilities will significantly impair the operating efficiency of the agency and will be detrimental to the hiring and retention of personnel. 72

Comp. Gen. 139 (1993); 49 Comp. Gen. 476 (1970); B-168946, Feb. 26, 1970;

o General Government Appropriation Act authorizes federal agencies to participate in state or local government programs designed to encourage employees to use public transportation. Pub. L. No. 101-509, § 629, 104 Stat. 1389, 1478 (Nov. 5, 1990).

o A government employee does not have a right to a parking space, with or without charge, and an agency is under no obligation to furnish one. See American

Federation of Government Employees v. Freeman, 498 F. Supp. 651, 654–55 (D.D.C. 1980) (government employee does not have a “property interest in free parking”); B-168096, Dec. 6, 1975 (furnishing of parking is not a right but a privilege).

o However, GAO noted that, if the Commission employees with disabilities pay substantially more to park closer to the building than employees without disabilities, the differential portion may be paid under our holding in 63 Comp. Gen.

270 (1984) o Nevertheless, the government may choose to provide parking facilities as an aid to operating efficiency and the hiring and retention of personnel. E.g., 63 Comp.

Gen. 270, 271 (1984); B-168096, Jan. 5, 1973 o The government has the discretionary authority under the Federal Property and

Administrative Services Act to charge employees for parking space furnished for their use. American Federation of Government Employees v. Carmen, 669 F.2d 815 (D.C. Cir.

1981). See also 55 Comp. Gen. 897 (1976); 52 Comp. Gen. 957, 960–61 (1973); B-155817, Mar.

11, 1966.

Finishes and Materials:

Carpet:

As a general rule VBA suggests the use of commercial type 24”x24” carpet tile (Modules) of heavy use with mergeable dye lots for longevity and uniform design.

In more specific technical terms, the physical performance should be as follow:

http://www.gao.gov/special.pubs/d04261sp.pdf http://www.gao.gov/special.pubs/d04261sp.pdf

LESSOR: ________ GOVERNMENT: ________ Page 7 o Tuft Bind (ASTM D-1335) loop pile, 8.0 lbs. minimum average value o Delamination Resistance of Secondary Backing: 2.5 lbs. per inch minimum o Colorfastness Crocking (AATCC 165); color transfer class 4 minimum, wet and dry o Electrostatic Propensity (AATCC 134); General use commercial carpet – 3.5 kV max o Flammability Properties: Carpet installation must comply with all applicable flammability regulations. Check state and local building and fire codes for specific requirements.

o Indoor Air Quality, carpet, adhesives, seam sealer, Cushion and underlayment:

Compliance with CRI Green Label Plus and Indoor Air Quality Testing Program o Delamination: Minimum of 2.5 per inch delamination resistance as ASTM D3936 o Soil/Stain Protection (AATCC 175-1991) > 8.0 on the Red 40 Stain Scale o Fungicidal (AATCC 174, Part lll) No growth with mold warranty o Dimensional Stability (Aachen Method Din 54318) < 0.10% change o Smoke Density (ASTM E662) < 450 Flaming Mode o Yarn Weight 18 oz. per yd2 o Cushion: always use manufacturer recommended cushions

First Impression:

The VBA First Impression Program is a comprehensive, nationwide effort to improve the appearance of the main entrance and Public Contact areas inside of the regional offices. Although it depends on the configuration of each site, the program is comprised of unifying and common identification signage by creating a powerful fusion of images that visually depicts the Veterans Affairs mission, goals and outreach programs, supporting its United States of America veterans. These graphic images convey the first impression of the Agency's services to both visitors and employees.

These environmental graphic displays help to demonstrate the Agency's mission of supporting and caring for the needs of service personnel and their families as well as how these services have developed and been enhanced over the years.

The design of the graphic feature could be of any combination of images from soldiers, military fields, joyful events or ceremonies, or only basic phrases or encouraging, celebrating words, images of monumental flags, VA logos or basic background accent colors.

The following should be of high consideration when designing the features with images of veterans:

o Utmost effort should be taken to consider images of both sexes o All effort should be taken to include images of all military services in the artwork collage o Make sure that no name is visible or readable o Consider all happy and joyful images rather than advocating conflict or war o Use images showing VBA division’s mission such as education, home loans, training, healthcare support, etc.

The materials and methods use to display the graphic features could be of the use of one or multiple possible variety of medias such as film on glazing, wall paper, Dibond or similar sturdy board material, stretch fabric, or any other proposed new material to express and display the VBA features and mission the best. The graphic feature could also be used to provide translucent and privacy while allowing natural light to the space in addition to enhancing the workplace environment.

LESSOR: ________ GOVERNMENT: ________ Page 8

There are variety methods of installation available which could be of on glazing, free hanging, and wall hanging, using graphic display bolts, tension cables or combination of all pending on the design and graphic design team’s suggestion and proposed details.

Installation of the graphics will be prioritized based on newly designed or renovated regional offices as part of the construction documents only.

If a location is selected at the time of the realignment, attention should be paid to provide additional structural support for the intended walls if larger features are considered.

Possible Locations:

Pending on availability of funds the placements of the First Impression Graphics are:

o Main Lobby – Full height fabric panels or other large medias o Public Contact reception/waiting area - Inkjet print on Melamine Panel or print on frosted film over glazing if is available o Walls within VSC in strategic location - Mural Graphics printed on Wallpaper o Interview Rooms – Glazing facing Public area

Flag Poles:

If required by the lease, a ground mounted flagpole, located preferably at the left of the entrance or front of the building, close or adjacent to the main entrance. It is preferable for the flag to be illuminated. The height of the pole should be around 32 feet.

Placement:

If you are facing the building, the proper placements of flags are as follow:

o If the center flag pole is taller in height, the US flag is in the center with State flag on the left and VA flag on the right.

If the flag poles are in line and in the same height, from left to right are: US, State and the VA flag.

Furniture:

Adequate and functional furniture should be selected and installed for all workspaces. The standard sizes to follow the VA general guideline for each category and grade as specified in a memorandum dated 17th of September 2013 as follow:

o SES Position: 150 Square Feet office o GS 15 and 14 Supervisor Position: 100 Square Feet office o GS 14 non-Supervisory, GS 13 and below Position: 56 Square Feet workstation o Intern Position: 48 Square Feet workstation o Contractor Position: 36 Square Feet workstation

For more detailed description refer to Space Size Standards below and VBA Master Program spreadsheet.

SES Office:

SES private office to receive free standing modular L shape furniture with adequate lower and overhead storage, wardrobe, mobile pedestal and rear credenza. There should be a task chair along with two guest chairs. A lateral matching color five high file cabinet to be included. There should be a tackable board, task light, monitor arm for two monitors, key board and mouse tray.

LESSOR: ________ GOVERNMENT: ________ Page 9

Office:

Private office to receive free standing modular L shape furniture with adequate lower and overhead storage, wardrobe and mobile pedestal. There should be a task chair along with two guest chairs. There should be a tackable board, task light, monitor arm for two monitors, key board and mouse tray.

Workstation:

Standard workstation to be of stackable tile, off modular system furniture with one two high file cabinet and overhead shelf/storage, wardrobe with side open shelves and mobile pedestal with top cushion. The standard height of panels is 48” for all sides except the spine panels which is shared with the side workstation and should be at 56” high. It is highly recommended to have the top tile to be of non- transparent/opaque glass or Plexiglas type for light transfer and privacy.

There should be a minimum of three accessories, task light, monitor arm for two monitors, small magnetic write-on-board with eraser shelf, a key board and mouse tray and a task chair. The system furniture should have at least three power outlets and a data receptacle. The system furniture should be capable of cable management to ensure easy access and securing of all required cables.

Other Considerations:

All specific requirements and needs other than standards such as special chairs, movable worksurface, additional lighting, and different paneling height or configuration requests should be submitted through Human Resources Office as “Reasonable Accommodation Consideration” for approval before implementation.

Interior Lighting, Daylighting, and Control Systems:

In order to effectively address the lighting issues and concerns, it is highly recommended to have all enclosed workplaces, including offices on the interior side of the floor in order to allow and provide natural light to the interior open office space. This will allow natural light to get into the working area to benefit all employees.. The interior offices will have glass sidelight facing the open office area. Also the lighting systems must be sensitive to the interior and architectural design while providing an adequate quality and quantity of illumination throughout the space and building. Yet, the lighting system must maintain an energy efficient design that, at minimum, meets ASHRAE/IES Standard 90.1 lighting power density requirements. In addition, the lighting design shall attempt to minimize maintenance requirements.

Illumination Level:

Required illumination level for typical interior spaces is indicated in the table below.

These ranges of illumination require the average illumination at the desk (workplane) to be greater than the minimum value and less than the maximum value. For those areas not listed in the table, the IES Lighting Handbook may be used as a guide.

Lighting requirements by Space Type:

Area/Activity Footcandles Office – Enclosed and open 41 – 55 Conference Meeting/Hearing/Multipurpose 25 – 40 Training/Classroom 40 – 55 High Density Filing Space 41 – 55 Lobby 16 – 25

LESSOR: ________ GOVERNMENT: ________ Page 10

Lounge/Reception 25 – 40 Restrooms 16 – 25 Corridor/Transition 16 – 25 Stairs 16 – 25 File Storage 16 – 25 Storage 9 – 16 Electrical/Mechanical Rooms 16 – 25

Computer Room/Data Closet

Product Criteria:

25 – 40 o All luminaires shall be pendent or recessed. No surface mounted fixture is allowed except in electrical/mechanical, telephone rooms and storage areas, and where ceiling height or plenum is limited.

o On projects which include new building construction or renovation of the entire regional office, the fixture shall be pendent indirect fixture throughout, if ceiling height allows, except service and electrical/mechanical spaces.

o On projects which include addition to the existing facility or partial renovation, the fixture to follow the existing condition or building standards.

o In leased spaces, light fixtures for areas such as building common area, core facilities, common lobbies and rest rooms to follow building standards.

o Indirect/direct fixtures shall have a minimum 2% indirect component and maximum 50% direct component.

o Where parabolic fixtures are used, louvers shall be semi-specular or diffused finishes; specular finishes shall not be used.

o All recessed downlights must use compact fluorescent or ceramic metal halide lamps. No incandescent technology shall be used.

o Many fixtures have different lamp and ballast options. For ease of maintenance, all similar building luminaires shall use the same lamps and ballasts.

o All linear fluorescent lamps must be SuperT8 or T5, low mercury lamps.

o When applicable, programmed start ballasts shall be specified for use in linear fixtures that are frequently switched on/off, such as with occupancy controls, with the exception of exit signs.

Conference, Hearing and Training Rooms:

These spaces shall have a combination of lighting options to provide multiple scenes for space flexibility. The use of dimming is only allowed for these spaces.

Other Special Areas:

Special lighting design concepts are encouraged in these areas:

o Main Entrance Lobbies o Elevator Lobbies o Public Corridors o Public Areas o Auditorium o Conference and Training Rooms o Dining/Pantry Areas and Services

Interview Rooms:

Interview Rooms are essential place to receive visitors and veterans to conduct the review of their business in a secure, safe and personal environment. All Interview rooms should be covered by appropriate Wi-Fi wireless networking technology for flexibility and easy use.

LESSOR: ________ GOVERNMENT: ________ Page 11

The followings are basic recommendations and considerations for the design:

• The space should be located adjacent to the Public Contact.

• The size of the room should be minimum of 8’-0” X 12’-0” to allow for a wheelchair.

• All partition walls to be slab to slab with cavity inserted sound attenuation insulation.

• The room to have two doors on opposite sides of the length, one for VBA employee opening to the secure area and the other for the visitor opening into public area.

• The space is considered an enclosed office preferably with glass partition on both entry sides. The glass partition could be covered with stripped film or graphic feature for semi privacy.

• The room should be equipped with Duress Alarm push button, preferably wireless for easier and more flexible use secured with Velcro under the worksurface on the side of VBA employee.

• The door leading to the secure area (VBA offices) should be equipped with cardkey access system from inside the room. The cardkey system to be connected to the building emergency system for fail safe-open upon activation of such emergency system.

• Provide delayed egress equipment – Use of the card reader on the interview room side, and request to exit (REX) switch (electronic operator) integral to the lever on the corridor side, will inhibit any alarm. The delayed egress equipment will be interfaced to the fire alarm for automatic release. Should an individual scale the counter and attempt to open the door, a sounder will sound, an alarm will annunciate at the security station, and a delayed egress timer will initiate, programmable for 15 or 30 seconds, to provide sufficient time for staff and security to respond. Since the standard delayed egress hardware are push bars, with the intention that the door swings out, for the design of the Interview Room, a maglocks type arrangement will need to be used on these doors instead.

• There should be continuous work surface furniture from side to side equipped with modesty panel, equally dividing the length of the room.

• There is a need for a task chair for employee and two guest chairs for visitors.

• The room should be equipped with power and data receptacles on one side of the worksurface.

• The room should be equipped with a monitor, PC, keyboard and mouse, and a docking station placed on the side with receptacles.

• No storage or file cabinets will be provided in this room.

• The ceiling lights should be controlled by sensor switch.

• The rooms should be graphically numbered on the outside facing public area for easy assignment.

Quantity of the Interview Rooms:

Regional Office:

The methodology to determine and calculate the number of needed Interview Rooms should be as follow:

o Average daily visitors X 45 min. average time per visitor/60 min./6 hrs. a day =

Number of Interview Rooms

As an example; in an average scenario for a Regional Office with medium traffic of 75 numbers of visitors per day, there is a need for 10 Interview Rooms.

Mail Room Design Requirement:

Ideally, the mail room should be located near Receiving and Discharge area.

LESSOR: ________ GOVERNMENT: ________ Page 12

• The mail room should be generally situated in a single room without outside windows.

Where outside windows exist, they shall be secure (security screens) to prevent easy access. The mail room shall have a Dutch door and a hand washing sink if possible. The mail room shall be served a dedicated constant volume air handling unit in accordance w/

TDG 15720.

• If it requires outside mailboxes, the mailbox doors shall have either keyed or combination locked doors.

• A roll up door mounted behind the mailboxes (on the rear access mailroom side) is required to secure the mailboxes.

• A secure package inspection room will be equipped with an extra large x-ray machine. All packages delivered to the building must be x-rayed prior to delivery.

PIV Office Requirements:

The office size should be similar to any standard 100 sf space with the possibility of the door be located on the long side providing longer room for placement of camera and background board.

The room should have at least a power duplex outlet on each wall and at least two data and phone on opposite shorter walls. The lighting should be treated similar to a standard office layout.

The furniture should consist of:

• A work desk,

• task chair,

• Side table for equipment,

• An isle for the background board,

• Tall lockable storage closet furniture for equipment,

• The office door should be equipped with standard office hardware and key system.

Satellite Dish:

The Knowledge Network (VAKN) is the VA Satellite Distribution Network that distributes informational and educational programming for VA employees. The installation of the dish has to be part of the renovation project or be coordinated with the RO’s local POC for accuracy and requirements. The location of the installation of such device has a direct relation to the location of the computer room.

The installation will progress through the following steps:

Technician Site Visit:

• A local satellite technician will contact the POC to schedule a Site Survey. The POC needs to be present at the time of the survey visit. The POC will identify a building where the computer room will best serve the location of the satellite receiver for CDN/LAN access.

• Also to be identified any room which requires satellite capability where the satellite broadcast would best be viewed for large groups and not from the desktop.

• A roof/location plan shall be submitted showing the proposed location.

• If a leased building or land is involved a landlord representative should give approval prior to the installation.

• The dish can be roof mounted with a non-penetrating roof mount which includes a frame, roof pad and cinder blocks or ground mounted with a single pole.

Installation:

• After the Survey the local satellite technician will contact the POC to schedule the installation. The POC needs to be present at the time of the installation to assure its compliance to the requirements as covered during the site visit. The install should only

LESSOR: ________ GOVERNMENT: ________ Page 13 take a few hours.

• The POC will acknowledge approval at the conclusion of the install.

• The installer should show the POC a signal from the satellite.

• The equipment will include:

1- 1.8 meter “Prodelin” Satellite Dish or 2.4 meter (Outside CONUS) 1- Roof mount kit or ground pole 1- Digital Satellite Receiver (IRD) Integrated Receiver Decoder 1- Necessary cable from dish to satellite receiver Dish Installation Check List included

Technical Specification Requirement:

The following make and model of equipment must be used in support of this initiative in order to compliment the standardization, global IRD update capability and technical support of the existing network:

o Satellite Dish – “Prodelin” series 1183 1.8 meter (receive only) (CONUS

Installations) o Satellite Dish – “Prodelin” series 1252 2.4 meter (single pole receive only)

(Outside CONUS) o Satellite Receiver (IRD) – Scientific Atlanta/Cisco PowerVu D9865 - Receiver must be coded with VAM code from Scientific Atlanta o Low Noise Block Converter (LNB) - must meet or exceed specs of the Norsat

4508A:

• Input Freq.: 11.7-12.2 Ghz

• L.O Freq. 10.76 Ghz

• Output Freq. 950-1450 Mhz

• Signal/Noise: 0.8dB

• L.O. Stability : 500 kHz

• L.O. Phase Noise: -65dBc/Hz @ 1kHz

• Conversion Gain 57dB +/- 0.6dB/36 Mhz segment

• Output Level (1dB compression)

• Power Requirements +15 to +24 Volts, 100 mA

• Input VSWR: 2.0:1

*Changes in the make or model other than those specified will only be made if this equipment is no longer available by the manufacturer or the COTR requests a change for the benefit and requirements of a specific installation.

Signage:

When preparing the sign design and requirements for a project, it might require editing to add and indicate new signs or eliminate signs that are not needed. Also, it will be necessary to adapt the specifications to project requirements required for the specific project in which they are intended.

The following illustrations are intended to show the desired configuration and intent of the various sign types and are not in scale.

Office Interior Signage:

The VBA space requires clear and coordinated system of signage and way finding. A standardized system of signage, with flexible and interchangeable components, is required throughout the space and offices in compliance with specific ADA requirements and parameters of design

LESSOR: ________ GOVERNMENT: ________ Page 14 including location, size, color, and tactical qualities of signage and use of graphic symbols to assist non-readers.

In leased spaces within the federal building or privately own building, all signage will be as per building standard. This will allow easy repairs or replacement if needed.

The design, spec, color and locations of the signage have to be part of the construction document to provide a smooth process. Any local or national signage company can be identified on the documents to provide standard office signage complying with the above requirements.

At minimum or if there is no building standard, the office signage has to be as follow:

• 9” X 9” Acrylic plaque material in Pantone color 2955U

• 1 ¼” high room number at the top left corner, raised cut out 1/8” thick, ¾ ” from left side

• Room Number in white T3

• Three 5/8” high interchangeable slots, 5/16” apart, starting 3 ¾” from the top of the sign, below the room number with clear front window; for name, function or title and department or division

• Text in white font size 36 on black background printed on heavy stock paper cut to insert

• Font type Helvetica Bold typography

• Installed on wall 63” to top of the sign above finished floor

• The entire assembly should be of one piece and attached to the wall with double sided foam tape or silastic adhesive to make the relocation easy and flexible

For facilities collocated with VA medical center or standalone building on VA campus, the signage to follow VA Interior Signage at http://www.cfm.va.gov/til/signs/Signage09- Interior.pdf

Regional Office Exterior Monumental Signage:

VBA standalone facilities/buildings require distingue identification and signage to identify such establishment as well as directing visitors to the site main access road.

Such sign should be positioned so drivers have a clear, unobstructed view of the sign.

Landscaping around the sign should be kept low and sprinklers, if any, to be positioned as such so they project away from the sign.

The monumental signage has to follow:

• The size of the face of the sign to be 4’-0” x 8’-0” x 1’-0” http://www.cfm.va.gov/til/signs/Signage09-Interior.pdf http://www.cfm.va.gov/til/signs/Signage09-Interior.pdf

LESSOR: ________ GOVERNMENT: ________ Page 15

• The 20” high base can be constructed of concrete or other masonry material in color and texture to compliment the building design and material that will provide a coordinated architectural look with the building finishes

• The sign should have the 9 ½” high VA logo on the left upper corner 8” from the top and 1’-0” from the left side

• The text of: “Department of Veterans Affairs” should be in two lines equal to 9 ½” height of the VA logo 4” away

• Next text line: “VA Regional Office” should be 3 ½” high letters, 4 ½” below the above text

• Next text line: “Name of the State” should be 2 ½” high letters, 2” below the above text

• All text to be in Helvetica Bold

• Text in White T3

• Background color Pantone 2955U

• Particular care should be taken to ensure that sign footings and foundations are correctly matched to the sign being installed.

For more detail and description refer to VA Exterior Signage at:

http://www.cfm.va.gov/til/signs/Signage04-Exterior.pdf

Space Size Standards:

VBA standard dimensions and sizes for offices, workstation types and other functions are based on the following chart. Please refer to Master Program for the quantity and other related information.

These dimensions might change or modify based on VA mission or function change.

Function T Size S http://www.cfm.va.gov/til/signs/Signage04-Exterior.pdf

LESSOR: ________ GOVERNMENT: ________ Page 16

Transaction/Access Window:

The access window if requested is usually installed in Public Contact or where there is a security concern. This is also used in most satellite small offices. The window should have 36” minimum width and 36” minimum height, similar to the bank teller’s window, equipped with 3 equal solid offset non-operable clear tempered glass pieces ¼” thick minimum, providing sound transmission only with maximum of 2 ½” opening at the bottom to allow for paper exchange and transaction counter with 4” maximum projecting lip on the customer’s side and 6” inside, installed at 34” maximum height above finish floor (AFF) to comply with ADA requirements. Location of the window should be coordinated with staff furniture on the reception side for ease of access and communication.

y p e

F

W o r k

S p a c e

WorkStation A 6' X 6' 36

WorkStation B 8' X 6' 48

WorkStation C 8' X 7' 56

O f fi c e

Office D 10' X 10' 10

Office F 10' X 20' 15

C o f.

R m

Conference Room L a r g e

Seating 16-30 People

Conference Room M e d i u m

Seating 10-16 People

Conference Room S m al l

Seating 4-8 People

O th e r

S p a c e s

Equipment Area 10' X 12' 12

Library 10' X 12' 12

Pantry 8' X 10' 80

Private Rest Room 5' X 9' 45

Special Project Room

10' X 15' 15

Testing Room 10' X 15' 15

Work Area 10' X 12' 12

LESSOR: ________ GOVERNMENT: ________ Page 17

All furniture on the office side has to be coordinated and designed to clear the window base for accessibility.

Veterans Service Organizations (VSO):

Veterans Service Organizations (VSO) are entities which provide many services to the veterans but not as part of VA or VBA. VBA is not obligated to provide any space or furniture but has been providing them as a courtesy and will continue to do so. All VBA office standards are applicable for VSO offices.

• All VSO offices are preferred to be located separate and off the main entry lobby if possible.

• All VSO offices to have a shared waiting, conference and breakroom.

• All require breakroom equipment such as refrigerator and microwave oven will be provided as part of the original build out. Any additional individual or personalized equipment such as coffee machine is to be provided and purchased by each VSO.

• No equipment such as coffee machine, microwave oven or popcorn machine are not allowed in the office or open area.

• Each VSO office will include ONE single enclosed office in addition to their required workstations.

• All required audio visual, printing equipment, fax and copy machine are provided and purchased by each VSO.

Wall Types and Requirements:

Except for the following list all partitions are with 5/8” gyp boards, no sound attenuation, and to the underneath of the ceiling tiles:

Slab to Slab Partitions:

Partitions to be constructed with 5/8” gyp board, with batt insulation in the stud cavity for:

• All demising walls separating the VA space from other tenants in multi-tenant floors

• All demising walls between VSO suits

• All conference rooms

• Training rooms

• LAN and Computer room/closets

• Computer room – All four sides of the Computer room should receive type XP gypsum board, mold/mildew/moisture resistant, on the computer room side

Floor to ceiling Partitions:

Partitions to be constructed with 5/8” gyp board, with batt insulation 24” above the ceiling blanket on both sides of the partition for the Director’s office, Conference/training rooms and Break rooms.

LESSOR: ________ GOVERNMENT: ________ Page 18

Housing Plan Summary:

Functional Space Type ABOA SF

General Office

Office workstations/open office 44,770

Closed offices 12,230

Conference / Training

Eight (8) conference rooms 29,224

Storage

General Storage 5,525

Misc. 1,196

Special Spaces

Clinics/health units 195

Physical fitness 1,950

ADP (high density PC’s) 650

Joint-use / retail 3,185

Copy Center 325

Kitchen / Break Room 2,652

TOTAL 101,902