The document is a product specification sheet for the Ripley LightWatchman® Button Wire-In Photocontrol, potentially relevant to the Linda Vista Avenue Street Light Conversion project in California. The specification details a photoelectric control device designed for post-top luminaires, outdoor decorative fixtures, and signage applications. The product is available in three voltage configurations (7001, 7002, 7003 models), with or without a single-gang stainless steel wall plate, and is UL Listed. The device meets ANSI standards C136.10, C136.24, and C136.41, and offers a rugged design suitable for flush-mount tight fitting installations.

The technical specifications highlight key performance characteristics, including a voltage range of 105-135V to 200-305V, an operating temperature range of -40°C to +70°C, and a load rating of 1000 Watts for Tungsten or 1200 VA for ballast. The photocontrol features a chemically coated cadmium sulfide cell, operates at light levels of 2 foot-candles (turn on) and 10 foot-candles (turn off), and includes color-coded lead wires. The device has a time delay of 1 to 4 minutes and a dielectric strength of 5000 volts between current-carrying parts and metal surfaces, making it a robust solution for outdoor lighting control applications.

View the file

Other files

Show all 14

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Wire-In Photocontrol LightWatchman® Button

Flush-mount Tight Fitting Installations

Rugged design, available in three voltages, with or without wall plate

UL Listed

Applications Post-top Luminaires

Outdoor Decorative Fixtures

Signage

Meets or exceeds rigid quality requirements of applicable ANSI C136.10, and C136.24 and C136.41

700X-WP

700X

Wiring

Line

Load

Common

7001 7001-WP 7002 7002-WP 7003 7003-WP

Wall Plate None

Single-gang Stainless

Steel Plate with gasket

None

Single-gang Stainless

Steel Plate with gasket

None

Single-gang Stainless

Steel Plate with gasket

Nominal Voltage 60 Hz 120 208/220 208—277

Voltage Range 105—135 200—250 200—305

Fail Mode On (contacts normally closed)

Switch SPST heavy duty, thermal bi-metallic

Load Rating 1000 Watt Tungsten / 1200 VA Ballast

Operating Temperature -40C to +70C (-40F to +158F)

Photocell Chemically coated cadmium sulfide

Dielectric Strength 5000 Volts between current carrying parts and metal surfaces

Time Delay 1 to 4 minutes

Operating Light Levels Turn On 2 FC ± 1 / Turn Off by 10 FC

Lead Wires Color Coded

#18 AWG

Common: White Line: Black Load: Red

Wire Temperature Rating 150C 90C 150C

Wire Length Minimum 15” long, stripped 1/2”

Nipple 3/8” NPT

Nut 3/8” NPT, thermoplastic

.825 20.95mm

.750 19.05mm

1.115 20.31mm

2.053

52.15mm

3/8”- 18 THREAD