Rio de La Plata Flood Control Project Sourrces Sought3.pdf

PDF 159 KB Posted

Attached to
Rio de La Plata Flood Control Project, North Coast Super-Aqueduct Relocation Project in Dorado and Toa Baja, Puerto Rico
Solicitation number
W51DQV25R00050003
Issued by

About this file

This is a Sources Sought notice issued by the U.S. Army Corps of Engineers, Caribbean District, for market research purposes regarding the Rio de La Plata Flood Control Project, North Coast Super-Aqueduct (NCSA) Relocation Project in Dorado and Toa Baja, Puerto Rico. The project involves relocating approximately 1,000 feet of a 72-inch diameter prestressed concrete cylinder pipe (PCCP) waterline to a 72-inch welded steel pipe (WSP) configuration installed between a parallel steel sheet pile system. The work includes installation of steel and high-density polyethylene (HDPE) temporary bypass pipes, water utility distribution accessories (manway, valves), cathodic corrosion protection, thrust blocks with deep foundations, braced steel sheet pile cofferdams with a minimum 15-foot differential head, and wet tapping operations. The project is critical as it serves approximately 190,000 clients (600,000 citizens) across north and metropolitan Puerto Rico. The prime contractor must either perform all wet tapping work activities or engage a first-tier subcontractor with a minimum of 15 years of experience in similar wet tapping requirements.

The estimated contract value ranges between $25,000,000 and $100,000,000, with full federal funding for an FY27 award. The estimated period of performance is approximately 560 calendar days following the Notice to Proceed. Responses are limited to 15 pages and must include firm identification information, interest in bidding, capability documentation with at least three comparable projects from the past 10 years, business classification (Small or Large), and details on anticipated subcontracting or teaming arrangements. The applicable NAICS code is 237110 (Water and Sewer Line and Related Structures Construction) with a small business size standard of $45 million. Responses must be submitted through the Procurement Integrated Enterprise Environment (PIEE) no later than 12:00 PM AST on May 7, 2025. Prior government contract experience is not required, but firms must be registered with the System for Award Management (SAM) to receive a contract award.

View the file

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Rio de La Plata Flood Control Project, North Coast Super-Aqueduct (NCSA) Relocation Project

San Juan, Puerto Rico

THIS NOTICE IS FOR SOURCES SOUGHT ONLY. THIS IS NOT A REQUEST FOR

PROPOSAL OR INVITATION FOR BID. SOLICITATION, SPECIFICATIONS, AND

DRAWINGS ARE NOT AVAILABLE.

The U.S. Army Corps of Engineers, Caribbean District is issuing this sources sought synopsis as a means of conducting market research to identify parties having an interest in and the resources to support this requirement for Indefinite Delivery Contract For Rio de La Plata Flood Control Project, North Coast Super-Aqueduct Relocation Project in Dorado and Toa Baja, Puerto Rico Within the Boundaries of the Caribbean District. The result of this market research will contribute to determining the method of procurement. The applicable North American Industry Classification System (NAICS) code for this proposed acquisition is 237110, Water and Sewer Line and Related Structures Construction. The small business size standard for NAICS 237110 is $45 Million.

THIS IS NOT A SOLICIATION FOR PROPOSAL AND NO CONTRACT WILL BE AWARDED

FROM THIS NOTICE. Submission of any information in response to this market survey is purely voluntary; no reimbursement will be made for any cost associated with providing information in response to this Sources Sought.

The purpose of this sources sought is to gain knowledge of interest, capabilities and qualifications of various members of the Water and Sewer Line and Related Structures Construction Community to include Small Disadvantage Business including firms participating on 8(a) Business development Program, Service-Disabled Veteran owned Small Business (SDVOSB); Veteran Owned Small Business, HUBZone Small Business, Small Business concern, Woman-Owned Small Business, or Economically Disadvantaged Woman-Owned Small Business and Other than Small Business Community (Unrestricted).

The Government must ensure there is adequate competition among the potential pool of responsible contractors.

This scope of work for the Rio de La Plata Flood Control Project, North Coast Super- Aqueduct (NCSA) Relocation Project includes relocation of approximately 1,000 feet of the NCSA to perform channel improvements in the area north of Highway PR-22 as part of a future project. The NCSA is a 72-inch diameter prestressed concrete cylinder pipe (PCCP) waterline that provides potable water from Arecibo to San Juan and is owned by the Puerto

Rico Aqueduct and Sewer Authority (PRASA). The relocated NCSA will be 72-inch welded steel pipe (WSP) installed between a parallel steel sheet pile system. Steel and high-density polyethylene (HDPE) temporary bypass pipes will be installed to minimize service interruptions during construction and provide flexibility of operation for future maintenance and/or repairs by PRASA. Work will require significant coordination with PRASA during construction. This water line provides potable water to approximately more than 190,000 clients (600,000 citizens) of the north and metropolitan areas of Puerto Rico. Due to the criticality of this water line, USACE requires the Prime Contractor to either perform all work activities related to the wet tapping of the water line or a first-tier subcontractor who will be under full control of the prime contractor. Experience of the wet tapping contractor shall not be less than 15 years in similar wet tapping requirements for this contract.

Current Order of Magnitude: Between $25,000,000.00 and $100,000,000.00

The contract will be Fully Funded for an FY27 award using 100% federal funding.

The project will have an estimated period of performance of approximately 560 calendar days after receipt of the Notice to Proceed (NTP).

Firm’s response to this Synopsis shall be limited to 15 pages and shall include the following information:

1. Firm’s name, address, a main point of contact (POC) telephone number, POC e-mail address, firm’s website if any, CAGE Code and UEI number, Company Size (Small or Large), in accordance with NAICS 237110.

2. Firm’s interest in proposal/bidding on the solicitation when it is issued.

3. Firm’s capability to perform a contract of this magnitude and complexity (include firm’s capability to execute comparable work performed within the past 10 years: This may and should be tailored specifically to the scope described above and with emphasis on projects that includes: (1) Construction and intervention of an active potable water pipeline at least 60 -inch diameter maintaining water service to customers without interruptions. This includes installation of water utility distribution accessories (manway, valves, etc.), cathodic corrosion protection, construction of thrust blocks including deep foundations, temporary bypass pipes, and wet tapping, (2) Construction of braced steel sheet pile cofferdams to facilitate excavation dewatering– the difference in water level (differential head) across the cofferdam must be a minimum of fifteen feet. Brief description of the work, customer name, timeliness of performance, customer satisfaction, and dollar value of the project) – provide at least 3 examples.

4. Firm’s business category, Other than small (Large), and if a Small Business, specify if your company is any of the following: Small Business, Small Disadvantaged Business including firms on the 8(a) Business development Program, Service-Disabled Veteran Owned Small Business (SDVOSB); Veteran Owned Small Business, HUBZone Small Business, Small Business concern, Women-Owned Small Business, or Economically Disadvantaged Women- Owned Small Business.

5. If significant subcontracting or teaming is anticipated in order to deliver technical capability, firms should address the structure of such arrangements to include Joint Venture information if applicable – existing and potential.

All responses to this sources sought notice/market research will be evaluated and used in determining acquisition strategy.

IMPORTANT: Submission of a Capabilities Statement is not a prerequisite to any potential future offerings, but participation will assist the Corps in tailoring requirements to be consistent with industry capabilities. This synopsis is for information and planning purposes only and is neither to be construed as a commitment by the Government nor will the Government pay for information solicited. Respondents WILL NOT be notified of the results of the evaluation. Statements that do not meet all requirements or not submitted within the allotted time will not be considered. Submit all capabilities statements through Procurement Integrated Enterprise Environment (PIEE) https://cac.piee.eb.mil/xhtml/unauth/home/login.xhtml . No hardcopy or facsimile submission will be accepted.

Submission Instructions: Interested Firms who consider themselves qualified to perform the above-listed services are invited to submit a response to this Sources Sought no later than 12:00 PM AST, 07 May 2025. All responses under this Sources Sought Notice must be submitted through PIEE.

Prior government contract work is not required for submitting a response under this sources sought.

You must be registered with the System for Award Management (SAM) in order to receive a Government contract award. To register go to www.sam.gov.

https://cac.piee.eb.mil/xhtml/unauth/home/login.xhtml http://www.sam.gov/

File details come from the government source that posted it. Updated .