STATEMENT OF WORK

FOR

GENIE LIFT REPAIR

JBSA LACKLAND A.F.B

3 Aug 2021

1. SCOPE OF WORK. Contractor shall repair a 135 foot Genie boom lift; model: ZX135V1 and serial number: ZX135H-4095. The Genie boom lift is located at 1260 EMT CIR, JBSA Lackland, TX building 10670. The Contractor shall be an authorized Genie dealer service center that is trained and qualified to work on the Genie Boom Lift. The Contractor shall inspect and repair the system to a fully functional operational status. The contractor shall provide industry standard practices for all repairs. All repairs shall be done in accordance to the manufacturer’s recommendations.

1.1 Warranty. Contractor shall provide warranty documentation on parts and labor for one year. This shall include a 6 month follow up and maintenance on any parts repaired on the Genie Lift. . The contractor shall respond within 24 hours upon notification of a repair issue.

1.2 Background. The unit was being driven and the wheel on the Genie Lift became loose and fluid started to leak. The unit had to be parked.

1.3 Requirement. The Contractor shall inspect the brakes, wheel drive, tires, lug nuts, wheel assembly and any other parts/components to determine what needs to be repaired and replaced. The contractor shall also conduct a safety inspection. The contractor shall repair and replace all parts/components needed to bring the system to a fully functional operational status.

Contractor shall supply all materials and replace/top off any fluids needed to have the machine ready for immediate use. All parts shall be an Original Equipment Manufacturer (OEM) part or a Genie approved replacement part. The contractor shall provide pictures and documentation of items being repaired. The contractor shall perform all work within 30 days of when the contract has been awarded at their location. The Contractor shall be responsible for providing all the required personnel, tool and equipment necessary to transport the Genie. The contractor shall be responsible for picking-up the Genie, transporting it to their location for inspection and repairs, and transporting the Genie to be dropped-off at 1260 EMT CIR, JBSA Lackland, TX building 10670.

2. HOURS OF OPERATION. The Contractor can reach the 502d CE Planning Engineering during the hours of 7:30 A. M. to 4:00 P. M., Monday through Friday. The point of contact (POC) to pick-up and drop-off the keys to the Genie will be either Luis Flores, Ruben Cepeda, or Rich Aguillon. Their contact information will be provided to the Contractor upon award.

3. QUALITY ASSURANCE. The government will perform inspections of the Contractor’s work, and acceptance of work shall only be provided when the Contractor’s work has been inspected and performance is deemed satisfactory. An authorized personnel from 502d CE Planning Engineering will perform the inspection and acceptance. The name of that individual shall be provided by the Power Pro shop POC, Richard Aguillon. The Planner and alternate POC is Edward Velez. Their contact information will be provided to the Contractor upon award.

4. MATERIAL SAFETY DATA SHEETS (MSDS). The 502d CE shall be provided with all the MSDS on all cleaning, solutions, and products that will be utilized prior to beginning work.

5. ENVIRONMENTAL COMPLIANCE. The contractor shall comply with all applicable federal, state, and local environmental laws and regulations.

6. CLEAN-UP. The contractor shall dispose of all generated waste off-site in accordance with all Federal, State and local laws and regulations.

GENIE LIFT REPAIR