RFQ 2214 Project Manual & Photos.pdf

PDF 1 MB Posted

Attached to
Dubuque DL Exterior Exit & Interior Painting
Solicitation number
645-RFQ-2214-2026
Issued by
Dubuque County, Iowa

About this file

The documents are standard material specifications for the Iowa Department of Transportation's project 645-RFQ-2214-2026, specifically for the Dubuque District Location (DL) Exterior Exit and Interior Painting project. The project involves comprehensive renovation work including exterior and interior painting, door hardware installation, hollow metal door and frame replacement, and associated surface preparation and finishing. The specifications cover detailed requirements for rough carpentry, joint sealants, hollow metal doors and frames, door hardware, and interior painting across multiple sections with precise technical standards and performance criteria.

The specifications outline detailed material requirements, including specific paint systems, hardware finishes, door types, and installation methodologies. The project emphasizes compliance with various industry standards such as ASTM, BHMA, and ADA requirements. Material selections include galvannealed steel for doors and frames, specific paint types like high-performance architectural interior latex and epoxy-modified latex, and hardware with warranties ranging from two to five years. The documents provide comprehensive guidance on surface preparation, application methods, quality assurance, and execution standards to ensure a high-quality, durable renovation of the facility's interior and exterior surfaces.

View the file

Other files

File Type Posted
1345397-event.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Iowa Department of Transportation

645-RFQ-2214-2026: Dubuque DL Exterior Exit & Interior Painting

Project Manual & Photos asmelse Text Box

DUBUQUE FLOOR PLAN

asmelse Line asmelse

SCALE: 1/2"=1'-0"

DUBUQUE EXTERIOR ELEVATION

asmelse Line asmelse

Line asmelse Line asmelse Line asmelse Line asmelse Line asmelse Line asmelse Line asmelse Polygon asmelse Polygon asmelse Polygon

Polygon

Callout

CONCRETE STOOP WITH 8" WIDE X 4'-0" DEEP TRENCH FOOTING

asmelse Callout

HM DOOR FRAME WITH DRIP EDGE

AND FLUSH DOOR

PREPPED FOR PANIC DEVICE INTERIOR AND EXIT ONLY ACCESS ON EXTERIOR

asmelse Callout

LINTLE

asmelse Text Box

DUBUQUE WALL SECTION

asmelse Line asmelse

Callout

PAINT WALL GRAY

FROM FLOOR TO CEILING, AROUND FURNTIURE

0-Standard Material Specifications - 1219 10-Sep-2025

Page

Rough Carpentry 06 1000

SECTION 06 1000

ROUGH CARPENTRY

PART 1 GENERAL

1.01 SECTION INCLUDES

A. Rough opening framing for doors, windows, and roof openings.

B. Miscellaneous wood nailers, furring, and grounds.

1.02 REFERENCE STANDARDS

A. ANSI A208.1 - American National Standard for Particleboard; 2022.

B. ASTM A153/A153M - Standard Specification for Zinc Coating (Hot-Dip) on Iron and Steel

Hardware; 2023.

C. ASTM E84 - Standard Test Method for Surface Burning Characteristics of Building Materials;

2024.

D. AWPA U1 - Use Category System: User Specification for Treated Wood; 2025.

E. ICC-ES AC38 - Acceptance Criteria for Water-Resistive Barriers; 2016, with Editorial Revision

(2021).

F. PS 1 - Structural Plywood; 2023.

G. PS 2 - Performance Standard for Wood Structural Panels; 2019.

H. PS 20 - American Softwood Lumber Standard; 2025.

I. SPIB (GR) - Standard Grading Rules; 2021.

J. WWPA G-5 - Western Lumber Grading Rules; 2025.

1.03 SUBMITTALS

A. Product Data: Provide technical data on insulated sheathing and application instructions.

B. Warranty Documentation: Submit manufacturer warranty and ensure that forms have been completed in Owner's name and registered with manufacturer.

1.04 DELIVERY, STORAGE, AND HANDLING

A. General: Cover wood products to protect against moisture. Support stacked products to prevent deformation and to allow air circulation.

PART 2 PRODUCTS

2.01 GENERAL REQUIREMENTS

A. Dimension Lumber: Comply with PS 20 and requirements of specified grading agencies.

1. Species: Douglas Fir-Larch, unless otherwise indicated.

2. If no species is specified, provide species graded by the agency specified; if no grading agency is specified, provide lumber graded by grading agency meeting the specified requirements.

3. Grading Agency: Grading agency whose rules are approved by the Board of Review, American Lumber Standard Committee at www.alsc.org, and who provides grading service for the species and grade specified; provide lumber stamped with grade mark unless otherwise indicated.

4. Lumber of other species or grades is acceptable provided structural and appearance characteristics are equivalent to or better than products specified.

B. Provide sustainably harvested wood; see Section 01 6000 - Product Requirements for requirements.

2.02 DIMENSION LUMBER FOR CONCEALED APPLICATIONS

A. Grading Agency: Southern Pine Inspection Bureau, Inc; SPIB (GR).

B. Sizes: Nominal sizes as indicated on drawings, S4S.

Page

Rough Carpentry 06 1000

C. Moisture Content: S-dry or MC19.

D. Stud Framing (2 by 2 through 2 by 6 ):

1. Grade: No. 2.

E. Miscellaneous Framing, Blocking, Nailers, Grounds, and Furring:

1. Lumber: S4S, No. 2 or Standard Grade.

2. Boards: Standard or No. 3.

2.03 ACCESSORIES

A. Metal and Finish of Fasteners:

1. Untreated Wood: Unfinished steel.

B. Fasteners and Anchors:

1. Metal and Finish: Hot-dipped galvanized steel complying with ASTM A153/A153M for high humidity and preservative-treated wood locations, unfinished steel elsewhere.

2. Anchors: Toggle bolt type for anchorage to hollow masonry.

3. Nails, Brads and Staples: ASTM F 1667.

4. Power-Driven Fasteners: NES NER-272.

5. Wood Screws: ASME B18.6.1.

C. Die-Stamped Connectors: Hot dipped galvanized steel, sized to suit framing conditions.

D. Water-Resistive Barrier: Plastic sheet complying with ICC-ES AC38.

PART 3 EXECUTION

3.01 INSTALLATION - GENERAL

A. Select material sizes to minimize waste.

B. Reuse scrap to the greatest extent possible; clearly separate scrap for use on site as accessory components, including: shims, bracing, and blocking.

3.02 TOLERANCES

A. Framing Members: 1/4 inch from true position, maximum.

B. Variation from Plane, Other than Floors: 1/4 inch in 10 feet maximum, and 1/4 inch in 30 feet maximum.

3.03 CLEANING

A. Do not leave wood, shavings, sawdust, etc. on the ground or buried in fill.

B. Prevent sawdust and wood shavings from entering the storm drainage system.

END OF SECTION

Page

Joint Sealants 07 9200

SECTION 07 9200

JOINT SEALANTS

PART 1 GENERAL

1.01 SECTION INCLUDES

A. Nonsag gunnable joint sealants.

B. Joint backings and accessories.

1.02 REFERENCE STANDARDS

A. ASTM C834 - Standard Specification for Latex Sealants; 2017 (Reapproved 2023).

B. ASTM C919 - Standard Practice for Use of Sealants in Acoustical Applications; 2024.

C. ASTM C1193 - Standard Guide for Use of Joint Sealants; 2025.

D. ASTM C1330 - Standard Specification for Cylindrical Sealant Backing for Use with Cold Liquid-

Applied Sealants; 2023.

E. ASTM D695 - Standard Test Method for Compressive Properties of Rigid Plastics; 2023.

F. SCAQMD 1168 - Adhesive and Sealant Applications; 1989, with Amendment (2022).

1.03 SUBMITTALS

A. Product Data: Submit manufacturer's technical datasheets for each product to be used; include the following:

1. Physical characteristics, including movement capability, VOC content, hardness, cure time, and color availability.

2. List of backing materials approved for use with the specific product.

3. Substrates that product is known to satisfactorily adhere to and with which it is compatible.

4. Substrates the product should not be used on.

5. Substrates for which use of primer is required.

6. Installation instructions, including precautions, limitations, and recommended backing materials and tools.

B. Color Cards for Selection: Where sealant color is not specified, submit manufacturer's color cards showing standard colors available for selection.

C. Executed warranty.

1.04 QUALITY ASSURANCE

A. Manufacturer Qualifications: Company specializing in manufacturing the products specified in this section with minimum three years documented experience.

B. Installer Qualifications: Company specializing in performing the work of this section and with at least three years of documented experience.

1.05 WARRANTY

A. Manufacturer Warranty: Provide 2-year manufacturer warranty for installed sealants and accessories that fail to achieve a watertight seal, exhibit loss of adhesion or cohesion, or do not cure. Complete forms in Owner's name and register with manufacturer.

B. Extended Correction Period: Correct defective work within 2-year period commencing on Date of Substantial Completion.

PART 2 PRODUCTS

2.01 JOINT SEALANT APPLICATIONS

A. Scope:

1. Exterior Joints:

a. Seal the following joints:

1) Joints between doors, windows, and other frames or adjacent construction.

2. Interior Joints:

Page

Joint Sealants 07 9200

a. Seal the following joints:

1) Joints between window frames and adjacent construction.

3. Interior Joints: Do not seal interior joints unless specifically indicated to be sealed. Interior joints to be sealed include, but are not limited to, the following items.

a. Joints between door, window, and other frames and adjacent construction.

b. Other joints indicated below.

B. Type Ext-1 - Exterior Joints: Use non-sag non-staining silicone sealant, unless otherwise indicated.

C. Type Int-1 - Interior Joints: Use non-sag Acrylic emulsion, paintable, latex sealant, unless otherwise indicated.

1. Type Int-1 - Wall and Ceiling Joints in Non-Wet Areas: Acrylic emulsion latex sealant.

2.02 ACCESSORIES

A. Sealant Backing Rod, Closed-Cell Type:

1. Cylindrical flexible sealant backings complying with ASTM C1330 Type C.

2. Size: 25 to 50 percent larger in diameter than joint width.

B. Masking Tape: Self-adhesive, nonabsorbent, nonstaining, removable without adhesive residue, and compatible with surfaces adjacent to joints and sealants.

C. Joint Cleaner: Noncorrosive and nonstaining type, type recommended by sealant manufacturer; compatible with joint forming materials.

PART 3 EXECUTION

3.01 EXAMINATION

A. Verify that joints are ready to receive work.

B. Verify that backing materials are compatible with sealants.

C. Verify that backer rods are of the correct size.

3.02 PREPARATION

A. Remove loose materials and foreign matter that could impair adhesion of sealant.

B. Clean joints, and prime as necessary, in accordance with manufacturer's instructions.

C. Perform preparation in accordance with manufacturer's instructions and ASTM C1193.

D. Mask elements and surfaces adjacent to joints from damage and disfigurement due to sealant work; be aware that sealant drips and smears may not be completely removable.

3.03 INSTALLATION

A. Install this work in accordance with sealant manufacturer's requirements for preparation of surfaces and material installation instructions.

B. Provide joint sealant installations complying with ASTM C1193.

C. Measure joint dimensions and size joint backers to achieve width-to-depth ratio, neck dimension, and surface bond area as recommended by manufacturer.

D. Install bond breaker backing tape where backer rod cannot be used.

E. Install sealant free of air pockets, foreign embedded matter, ridges, and sags, and without getting sealant on adjacent surfaces.

F. Do not install sealant when ambient temperature is outside manufacturer's recommended temperature range, or will be outside that range during the entire curing period, unless manufacturer's approval is obtained and instructions are followed.

G. Nonsag Sealants: Tool surface concave, unless otherwise indicated; remove masking tape immediately after tooling sealant surface.

H. Concrete Floor Joint Filler: After full cure, shave joint filler flush with top of concrete slab.

Page

Joint Sealants 07 9200

3.04 FIELD QUALITY CONTROL

A. Remove and replace failed portions of sealants using same materials and procedures as indicated for original installation.

Page

Hollow Metal Doors and Frames 08 1113

SECTION 08 1113

HOLLOW METAL DOORS AND FRAMES

PART 1 GENERAL

1.01 SECTION INCLUDES

A. Non-fire-rated hollow metal doors and frames.

1.02 ABBREVIATIONS AND ACRONYMS

A. ANSI: American National Standards Institute.

B. HMMA: Hollow Metal Manufacturers Association.

C. NFPA: National Fire Protection Association.

D. SDI: Steel Door Institute.

E. UL: Underwriters Laboratories.

1.03 REFERENCE STANDARDS

A. ADA Standards - 2010 ADA Standards for Accessible Design; 2010.

B. ANSI/SDI A250.3 - Test Procedure and Acceptance Criteria for Factory Applied Finish Coatings for Steel Doors and Frames; 2025.

C. ANSI/SDI A250.4 - Test Procedure and Acceptance Criteria for Physical Endurance for Steel

Doors, Frames and Frame Anchors; 2024.

D. ANSI/SDI A250.8 - Specifications for Standard Steel Doors and Frames (SDI-100); 2023.

E. ANSI/SDI A250.10 - Test Procedure and Acceptance Criteria for Prime Painted Steel Surfaces for Steel Doors and Frames; 2025.

F. ASTM A653/A653M - Standard Specification for Steel Sheet, Zinc-Coated (Galvanized) or Zinc-

Iron Alloy-Coated (Galvannealed) by the Hot-Dip Process; 2023.

G. ASTM A1008/A1008M - Standard Specification for Steel, Sheet, Cold-Rolled, Carbon, Structural, High-Strength Low-Alloy, High-Strength Low-Alloy with Improved Formability, Required Hardness, Solution Hardened, and Bake Hardenable; 2024.

H. ASTM A1011/A1011M - Standard Specification for Steel, Sheet and Strip, Hot-Rolled, Carbon, Structural, High-Strength Low-Alloy, High-Strength Low-Alloy with Improved Formability, and Ultra-High Strength; 2023.

I. BHMA A156.115 - Hardware Preparation in Steel Doors and Frames; 2016.

J. ICC A117.1 - Accessible and Usable Buildings and Facilities; 2017.

K. NAAMM HMMA 830 - Hardware Selection for Hollow Metal Doors and Frames; 2002.

L. NAAMM HMMA 831 - Hardware Locations for Hollow Metal Doors and Frames; 2024.

M. NAAMM HMMA 840 - Guide Specifications for Receipt, Storage and Installation of Hollow Metal

Doors and Frames; 2024.

N. NAAMM HMMA 861 - Guide Specifications for Commercial Hollow Metal Doors and Frames;

2014.

O. SDI 117 - Manufacturing Tolerances for Standard Steel Doors and Frames; 2023.

1.04 SUBMITTALS

A. Product Data: Materials and details of design and construction, hardware locations, reinforcement type and locations, anchorage and fastening methods, and finishes.

B. Shop Drawings: Details of each opening, showing elevations, glazing, frame profiles, and any indicated finish requirements.

C. Color selection chart ( provide 1 original paper copy and 1 PDF copy), showing factory finishes, colors, and surface texture.

Page

Hollow Metal Doors and Frames 08 1113

D. Installation Instructions: Manufacturer's published instructions, including any special installation instructions relating to this project.

1.05 QUALITY ASSURANCE

A. Manufacturer Qualifications: Provide hollow metal doors and frames from SDI Certified manufacturer: https://steeldoor.org/sdi-certified/#sle.

B. Installer Qualifications: Company specializing in performing work of the type specified and with at least three years of documented experience.

C. Maintain at project site copies of reference standards relating to installation of products specified.

1.06 DELIVERY, STORAGE, AND HANDLING

A. Comply with NAAMM HMMA 840 or ANSI/SDI A250.8 (SDI-100) in accordance with specified requirements.

B. Protect with resilient packaging; avoid humidity build-up under coverings; prevent corrosion and adverse effects on factory applied painted finish.

PART 2 PRODUCTS

2.01 PERFORMANCE REQUIREMENTS

A. Requirements for Hollow Metal Doors and Frames:

1. Steel Sheet: Comply with one or more of the following requirements; galvannealed steel complying with ASTM A653/A653M, cold-rolled steel complying with ASTM A1008/A1008M, or hot-rolled pickled and oiled (HRPO) steel complying with ASTM A1011/A1011M, commercial steel (CS) Type B, for each.

2. Accessibility: Comply with ICC A117.1 and ADA Standards.

3. Door Top Closures: Flush end closure channel, with top and door faces aligned.

4. Door Edge Profile: Manufacturers standard for application indicated.

5. Typical Door Face Sheets: Flush.

6. Glazed Lights: Non-removable stops on non-secure side; sizes and configurations as indicated on drawings. Style: Manufacturer's standard.

7. Hardware Preparations, Selections and Locations: Comply with NAAMM HMMA 830 and

NAAMM HMMA 831 or BHMA A156.115 and ANSI/SDI A250.8 (SDI-100) in accordance with specified requirements.

8. Zinc Coating for Typical Interior and/or Exterior Locations: Provide metal components zinc-coated (galvanized) and/or zinc-iron alloy-coated (galvannealed) by the hot-dip process in accordance with ASTM A653/A653M, with manufacturer's standard coating thickness, unless noted otherwise for specific hollow metal doors and frames.

a. Based on SDI Standards: Provide at least A40/ZF120 (galvannealed) when necessary, coating not required for typical interior door applications, and at least A60/ZF180 (galvannealed) for corrosive locations.

B. Combined Requirements: If a particular door and frame unit is indicated to comply with more than one type of requirement, comply with the specified requirements for each type; for instance, an exterior door that is also indicated as being sound-rated must comply with the requirements specified for exterior doors and for sound-rated doors; where two requirements conflict, comply with the most stringent.

2.02 HOLLOW METAL DOORS

A. Exterior Doors including interior garage bay openings: Thermally insulated.

1. Based on SDI Standards: ANSI/SDI A250.8 (SDI-100).

a. Level 1 - Standard-duty.

b. Physical Performance Level C, 250,000 cycles; in accordance with ANSI/SDI A250.4.

c. Model 1 - Full Flush.

d. Door Face Metal Thickness: 20 gauge, 0.032 inch, minimum.

e. Zinc Coating: A60/ZF180 galvannealed coating; ASTM A653/A653M.

Page

Hollow Metal Doors and Frames 08 1113

2. Door Core Material: Polyurethane, 1.8 lbs/cu ft minimum density.

3. Door Thermal Resistance: R-Value of 8.7, minimum, for installed thickness of polyurethane.

4. Door Thickness: 1-3/4 inches, nominal.

5. Weatherstripping: Refer to Section 08 7100.

2.03 HOLLOW METAL FRAMES

A. Comply with standards and/or custom guidelines as indicated for corresponding door in accordance with applicable door frame requirements.

B. Exterior Door Frames: Full profile/continuously welded type.

1. Galvanizing: Components hot-dipped zinc-iron alloy-coated (galvannealed) in accordance with ASTM A653/A653M, with A40/ZF120 coating.

2. Frame Metal Thickness: 16 gage, 0.053 inch, minimum.

3. Frame Finish: Factory finished.

4. Weatherstripping: Separate, see Section 08 7100.

5. Thermal break: NFRC 102, U-Value of 0.36.

2.04 FINISHES

A. Primer: Rust-inhibiting, complying with ANSI/SDI A250.10, door manufacturer's standard.

B. Factory Finish: Complying with ANSI/SDI A250.3, manufacturer's standard coating.

1. Color: As selected by Architect from manufacturer's standard range.

2.05 ACCESSORIES

A. Silencers: Resilient rubber, fitted into drilled hole; provide three on strike side of single door, three on center mullion of pairs, and two on head of pairs without center mullions.

B. Temporary Frame Spreaders: Provide for factory- or shop-assembled frames.

PART 3 EXECUTION

3.01 EXAMINATION

A. Verify existing conditions before starting work.

B. Verify that opening sizes and tolerances are acceptable.

C. Verify that finished walls are in plane to ensure proper door alignment.

3.02 PREPARATION

A. Coat inside of frames to be installed in masonry or to be grouted, with bituminous coating, prior to installation.

3.03 INSTALLATION

A. Install doors and frames in accordance with manufacturer's instructions and related requirements of specified door and frame standards or custom guidelines indicated.

B. Coordinate frame anchor placement with wall construction.

C. Comply with glazing installation requirements of Section 08 8000.

D. Touch up damaged factory finishes.

3.04 TOLERANCES

A. Clearances Between Door and Frame: Comply with related requirements of specified frame standards or custom guidelines indicated in accordance with SDI 117 or NAAMM HMMA 861.

B. Maximum Diagonal Distortion: 1/16 inch measured with straight edge, corner to corner.

3.05 ADJUSTING

A. Adjust for smooth and balanced door movement.

B. Adjust sound control doors so that seals are fully engaged when door is closed.

Page

Door Hardware 08 7100

SECTION 08 7100

DOOR HARDWARE

PART 1 GENERAL

1.01 SECTION INCLUDES

A. Hardware for hollow metal doors.

B. Thresholds.

C. Weatherstripping and gasketing.

1.02 RELATED REQUIREMENTS

A. Section 08 1113 - Hollow Metal Doors and Frames.

1.03 REFERENCE STANDARDS

A. ADA Standards - 2010 ADA Standards for Accessible Design; 2010.

B. BHMA A156.1 - Standard for Butts and Hinges; 2021.

C. BHMA A156.3 - Exit Devices; 2025.

D. BHMA A156.4 - Door Closers and Pivots; 2024.

E. BHMA A156.5 - Cylinders and Input Devices for Locks; 2020.

F. BHMA A156.6 - Standard for Architectural Door Trim; 2021.

G. BHMA A156.7 - Template Hinge Dimensions; 2022.

H. BHMA A156.8 - Door Controls - Overhead Stops and Holders; 2021.

I. BHMA A156.15 - Release Devices - Closer Holder, Electromagnetic and Electromechanical;

2021.

J. BHMA A156.18 - Standard for Materials and Finishes; 2020.

K. BHMA A156.21 - Thresholds; 2025.

L. BHMA A156.22 - Standard for Gasketing; 2021.

M. BHMA A156.31 - Electric Strikes and Frame Mounted Actuators; 2024.

N. BHMA A156.115 - Hardware Preparation in Steel Doors and Frames; 2016.

O. ICC A117.1 - Accessible and Usable Buildings and Facilities; 2017.

P. NFPA 101 - Life Safety Code; Most Recent Edition Adopted by Authority Having Jurisdiction, Including All Applicable Amendments and Supplements.

Q. UL 437 - Standard for Key Locks; Current Edition, Including All Revisions.

1.04 ADMINISTRATIVE REQUIREMENTS

A. Coordinate the manufacture, fabrication, and installation of products that door hardware is installed on.

B. Furnish templates for door and frame preparation to manufacturers and fabricators of products requiring internal reinforcement for door hardware.

1.05 SUBMITTALS

A. Product Data: Manufacturer's catalog literature for each type of hardware, marked to clearly show products to be furnished for this project, and includes construction details, material descriptions, finishes, and dimensions and profiles of individual components.

B. Shop Drawings - Door Hardware Schedule: Submit detailed listing that includes each item of hardware to be installed on each door. Use door numbering scheme as included in Contract Documents.

1. Prepared by or under supervision of Architectural Hardware Consultant (AHC).

2. List groups and suffixes in proper sequence.

3. Provide complete description for each door listed.

Page

Door Hardware 08 7100

4. Provide manufacturer name, product names, and catalog numbers; include functions, types, styles, sizes and finishes of each item.

5. Include account of abbreviations and symbols used in schedule.

C. Maintenance Data: Include data on operating hardware, lubrication requirements, and inspection procedures related to preventative maintenance.

D. Project Record Documents: Record actual locations of concealed equipment, services, and conduit.

E. Maintenance Materials and Tools: Furnish the following for Owner's use in maintenance of project.

1. Tools: One set of each special wrench or tool applicable for each different or special hardware component, whether supplied by hardware component manufacturer or not.

1.06 QUALITY ASSURANCE

A. Manufacturer Qualifications: Company specializing in manufacturing products specified in this section with minimum three years of documented experience.

B. Supplier Qualifications: Company with certified Architectural Hardware Consultant (AHC) to assist in work of this section.

1.07 DELIVERY, STORAGE, AND HANDLING

A. Package hardware items individually; label and identify each package with door opening code to match door hardware schedule.

1.08 WARRANTY

A. Manufacturer's Warranty: Provide warranty against defects in material and workmanship for period indicated. Complete forms in Owner's name and register with manufacturer.

1. Closers: Five years, minimum.

2. Exit Devices: Three years, minimum.

3. Locksets and Cylinders: Three years, minimum.

4. Other Hardware: Two years, minimum.

PART 2 PRODUCTS

2.01 DESIGN AND PERFORMANCE CRITERIA

A. Provide specified door hardware as required to make doors fully functional, compliant with applicable codes, and secure to extent indicated.

B. Provide individual items of single type, of same model, and by same manufacturer.

C. Provide door hardware products that comply with the following requirements:

1. Applicable provisions of federal, state, and local codes.

2. Accessibility: ADA Standards and ICC A117.1.

3. Hardware Preparation for Steel Doors and Steel Frames: BHMA A156.115.

2.02 HINGES

A. Hinges: Comply with BHMA A156.1, Grade 1.

1. Butt Hinges: Comply with BHMA A156.1 and BHMA A156.7 for templated hinges.

a. Provide hinge width required to clear surrounding trim.

2. Provide hinges on every swinging door.

3. Provide five-knuckle full mortise butt hinges unless otherwise indicated.

4. Provide ball-bearing hinges at each door with closer.

5. Provide non-removable pins on exterior outswinging doors.

6. Provide non-removable pins on interior outswinging doors at locations as indicated.

7. Provide power transfer hinges where electrified hardware is mounted in door leaf.

8. Provide following quantity of butt hinges for each door:

a. Doors up to 60 inches High: Two hinges.

b. Doors From 60 inches High up to 90 inches High: Three hinges.

Page

Door Hardware 08 7100

c. Doors 90 inches High up to 120 inches High: Four hinges.

2.03 EXIT DEVICES

A. Manufacturers:

1. Basis of Design: Von Duprin, an Allegion brand ;99 Series : www.allegion.com/us/#sle. .

B. Exit Devices: Comply with BHMA A156.3, Grade 1.

1. Lever design to match lockset trim.

2. Provide cylinder with cylinder dogging or locking trim.

3. Provide exit devices properly sized for door width and height.

4. Provide strike as recommended by manufacturer for application indicated.

5. Provide UL (DIR) listed exit device assemblies for fire-rated doors and panic device assemblies for non-fire-rated doors

6. .Grooved case.

2.04 CYLINDRICAL LOCKS

2.05 CLOSERS

A. Manufacturers; Surface Mounted:

1. Basis of Design: LCN 4040 .

B. Closers: Comply with BHMA A156.4, Grade 1.

1. Type: Surface mounted to door.

2. Provide door closer on each exterior door.

3. At corridor entry doors, mount closer on room side of door.

4. At outswinging exterior doors, mount closer on interior side of door.

2.06 FLOOR STOPS

A. Manufacturers:

B. Floor Stops: Comply with BHMA A156.16, Grade 1 and Resilient Material Retention Test as described in this standard.

1. Provide floor stops when wall surface is not available; be cautious not to create a tripping hazard.

2. Type: Manual hold-open , with bumper floor stop .

3. Material: Stainless steel housing with rubber insert.

2.07 THRESHOLDS

A. Thresholds: Comply with BHMA A156.21.

1. Provide threshold at interior doors for transition between two different floor types , and at openings from garage spaces to interior spaces at office area. , unless otherwise indicated.

2. Provide threshold at each exterior door, unless otherwise indicated.

3. Type: Flat surface.

4. Material: Aluminum.

5. Threshold Surface: Fluted horizontal grooves across full width.

6. Field cut threshold to profile of frame and width of door sill for tight fit.

7. Provide non-corroding fasteners at exterior locations.

2.08 WEATHERSTRIPPING AND GASKETING

A. Weatherstripping and Gasketing: Comply with BHMA A156.22.

1. Head and Jamb Type: Adjustable.

2. Door Sweep Type: Door shoe with drip cap .

3. Material: Aluminum , with neoprene weatherstripping .

4. Provide weatherstripping on each exterior door at head, jambs, and meeting stiles of door pairs, unless otherwise indicated.

5. Provide door bottom sweep on each exterior door, unless otherwise indicated.

Page

Door Hardware 08 7100

2.09 RAIN GUARD

A. Rain Guard: Comply with BHMA A156.22.

1. Head: Adjustable.

2. Material: Aluminum .

B. Provide door rain guard on each exterior door, unless otherwise indicated.

C. Provide applicable gasketing on doors indicated as "Lightproof."

2.10 SILENCERS

A. Silencers: Provide at equal locations on door frame to mute sound of door's impact upon closing.

1. Single Door: Provide three on strike jamb of frame.

2. Material: Rubber, gray color.

2.11 FINISHES

A. Finishes: Provide door hardware of same finish, unless otherwise indicated.

1. Finish: 626; satin chromium plated over nickel, with brass or bronze base material (former US equivalent US26D) ; BHMA A156.18.

2. Exceptions:

a. Where base material metal is specified to be different, provide finish that is an equivalent appearance in accordance with BHMA A156.18.

PART 3 EXECUTION

3.01 EXAMINATION

A. Verify that doors and frames are ready to receive this work; labeled, fire-rated doors and frames are properly installed, and dimensions are as indicated on shop drawings.

3.02 INSTALLATION

A. Install hardware in accordance with manufacturer's instructions and applicable codes.

B. Use templates provided by hardware item manufacturer.

C. Do not install surface mounted items until application of finishes to substrate are fully completed.

D. Door Hardware Mounting Heights: Distance from finished floor to center line of hardware item.

As indicated in following list; unless noted otherwise in Door Hardware Schedule or on drawings.

1. Mounting heights in compliance with ADA Standards:

a. Locksets: 40-5/16 inch.

b. Exit Devices: 40-5/16 inch.

E. Set exterior door thresholds with full-width bead of elastomeric sealant at each point of contact with floor providing a continuous weather seal; anchor thresholds with stainless steel countersunk screws.

3.03 ADJUSTING

A. Adjust hardware for smooth operation.

B. Adjust gasketing for complete, continuous seal; replace if unable to make complete seal.

3.04 CLEANING

A. Clean adjacent surfaces soiled by hardware installation.

3.05 PROTECTION

A. Protect finished Work under provisions of Section 01 7000 - Execution and Closeout

Requirements.

B. Do not permit adjacent work to damage hardware or finish.

Ames Remodels 09 9123 - 1 Interior Painting

SECTION 09 9123

INTERIOR PAINTING

PART 1 GENERAL

1.01 SECTION INCLUDES

A. Surface preparation.

B. Field application of paints.

C. Scope: Finish interior surfaces exposed to view, unless fully factory-finished and unless otherwise indicated.

D. Do Not Paint or Finish the Following Items:

1. Items factory-finished unless otherwise indicated; materials and products having factory-applied primers are not considered factory finished.

2. Items indicated to receive other finishes.

3. Items indicated to remain unfinished.

4. Fire rating labels, equipment serial number and capacity labels, bar code labels, and operating parts of equipment.

5. Floors, unless specifically indicated.

6. Glass.

7. Concealed pipes, ducts, and conduits.

1.02 REFERENCE STANDARDS

A. MPI (APSM) - Master Painters Institute Architectural Painting Specification Manual; Current

Edition.

B. SSPC-SP 1 - Solvent Cleaning; 2015, with Editorial Revision (2016).

C. SSPC-SP 6/NACE No.3 - Commercial Blast Cleaning; 2006.

1.03 SUBMITTALS

A. Product Data: Provide complete list of products to be used, with the following information for each:

1. Manufacturer's name, product name and/or catalog number, and general product category

(e.g., "alkyd enamel").

2. MPI product number (e.g., MPI #47).

3. Cross-reference to specified paint system products to be used in project; include description of each system.

B. Samples: Submit one paper "draw down" samples, 8-1/2 by 11 inches in size, illustrating range of colors available for each finishing product specified.

1. Where sheen is specified, submit samples in only that sheen.

1.04 QUALITY ASSURANCE

A. Applicator Qualifications: Company specializing in performing the type of work specified with minimum three years experience and approved by manufacturer .

1.05 DELIVERY, STORAGE, AND HANDLING

A. Deliver products to site in sealed and labeled containers; inspect to verify acceptability.

B. Container Label: Include manufacturer's name, type of paint, brand name, lot number, brand code, coverage, surface preparation, drying time, cleanup requirements, color designation, and instructions for mixing and reducing.

C. Paint Materials: Store at minimum ambient temperature of 45 degrees F and a maximum of 90 degrees F, in ventilated area, and as required by manufacturer's instructions.

1.06 FIELD CONDITIONS

A. Do not apply materials when surface and ambient temperatures are outside the temperature ranges required by the paint product manufacturer.

Ames Remodels 09 9123 - 2 Interior Painting

B. Follow manufacturer's recommended procedures for producing best results, including testing of substrates, moisture in substrates, and humidity and temperature limitations.

C. Provide lighting level of 80 fc measured mid-height at substrate surface.

PART 2 PRODUCTS

2.01 PAINTS AND FINISHES - GENERAL

A. Paints and Finishes: Ready-mixed, unless intended to be a field-catalyzed paint.

1. Provide paints and finishes of a soft paste consistency, capable of being readily and uniformly dispersed to a homogeneous coating, with good flow and brushing properties, and capable of drying or curing free of streaks or sags.

2. Supply each paint material in quantity required to complete entire project's work from a single production run.

3. Do not reduce, thin, or dilute paint or finishes or add materials unless such procedure is specifically described in manufacturer's product instructions.

2.02 PAINT SYSTEMS - INTERIOR

A. Paint I-OP - Interior Surfaces to be Painted, Unless Otherwise Indicated: Including gypsum board .

1. Two top coats and one coat primer.

2. Top Coat(s): High Performance Architectural Interior Latex; MPI #138, 139, 140, 141, or

142.

a. Products:

1) Sherwin-Williams ProMar 200 HP Series, Eg-Shel. (MPI #139)

3. Top Coat Sheen:

a. Eggshell: MPI gloss level 3; use this sheen at all locations.

B. Paint I-OP-MD-DT - Medium Duty Door/Trim: For surfaces subject to frequent contact by occupants, including metals and wood:

1. Medium duty applications include doors and door frames .

2. Two top coats and one coat primer.

3. Top Coat(s): Interior Epoxy-Modified Latex; MPI #115 or 215.

a. Products:

1) Sherwin-Williams Waterbased Catalyzed Epoxy, Semi-Gloss.

C. Paint MI-OP-2A - Ferrous Metals, Primed, Alkyd, 2 Coat:

1. Touch-up with alkyd primer.

2. Gloss: Two coats of alkyd enamel .

3. Semi-gloss: Two coats of alkyd enamel .

D. Paint GI-OP-2A - Gypsum Board/Plaster, Alkyd, 2 Coat:

1. One coat of alkyd primer sealer.

2. Eggshell: One coat of alkyd enamel .

2.03 PRIMERS

A. Primers: Provide the following unless other primer is required or recommended by manufacturer of top coats.

1. Interior Drywall Primer Sealer.

PART 3 EXECUTION

3.01 EXAMINATION

A. Verify that surfaces are ready to receive work as instructed by the product manufacturer.

B. Examine surfaces scheduled to be finished prior to commencement of work. Report any condition that may potentially affect proper application.

C. Test shop-applied primer for compatibility with subsequent cover materials.

Ames Remodels 09 9123 - 3 Interior Painting

D. Measure moisture content of surfaces using an electronic moisture meter. Do not apply finishes unless moisture content of surfaces is below the following maximums:

1. Gypsum Wallboard: 12 percent.

3.02 PREPARATION

A. Clean surfaces thoroughly and correct defects prior to application.

B. Prepare surfaces using the methods recommended by the manufacturer for achieving the best result for the substrate under the project conditions.

C. Remove or mask surface appurtenances, including electrical plates, hardware, light fixture trim, escutcheons, and fittings, prior to preparing surfaces or finishing.

D. Seal surfaces that might cause bleed through or staining of topcoat.

E. Gypsum Board: Fill minor defects with filler compound. Spot prime defects after repair.

F. Ferrous Metal:

1. Solvent clean according to SSPC-SP 1.

2. Remove rust, loose mill scale, and other foreign substances using methods recommended in writing by paint manufacturer and blast cleaning in accordance with SSPC-SP 6/NACE No.3. Protect from corrosion until coated.

G. Wood Surfaces to Receive Opaque Finish: Wipe off dust and grit prior to priming. Seal knots, pitch streaks, and sappy sections with sealer. Fill nail holes and cracks after primer has dried;

sand between coats. Back prime concealed surfaces before installation.

3.03 APPLICATION

A. Apply products in accordance with manufacturer's written instructions and recommendations in

"MPI Architectural Painting Specification Manual".

B. Do not apply finishes to surfaces that are not dry. Allow applied coats to dry before next coat is applied.

C. Apply each coat to uniform appearance in thicknesses specified by manufacturer.

D. Vacuum clean surfaces of loose particles. Use tack cloth to remove dust and particles just prior to applying next coat.

E. Reinstall electrical cover plates, hardware, light fixture trim, escutcheons, and fittings removed prior to finishing.

3.04 CLEANING

A. Collect waste material that could constitute a fire hazard, place in closed metal containers, and remove daily from site.

3.05 PROTECTION

A. Protect finishes until completion of project.

B. Touch-up damaged finishes after Substantial Completion.