This document is an RFQ (Request for Quote) Attachment 1 - Schedule of Prices and Salient Characteristics for autoclave biological indicators and chemical integrators. The solicitation is for two specific products from 3M: 65 cases of Attest Rapid Steam BI (Part Number 1292-S) and 150 cases of Comply SteriGage Steam Chemical Integrator (Part Number 1243A). Both products are specialized sterilization indicators with specific technical requirements, including ISO compliance, detailed performance characteristics, and compatibility with specific reading equipment.
The delivery will be to the USDA NBAF (National Bio and Agro-Defense Facility) in Manhattan, KS, with a flexible delivery schedule over a 12-month performance period. The RFQ is an unrestricted solicitation under NAICS code 339113, with quotes due by 5pm Pacific Time on 07/31/2025, to be submitted via email to Michael.hassett@usda.gov. The government seeks quotes for these scientific measurement products with specific technical specifications for sterilization process monitoring, allowing batch deliveries to be mutually agreed upon by both parties.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| RFQ 1232SA25Q0391 - Terms and Conditions.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
RFQ 1232SA25Q0391
Attachment 1 – Schedule of Prices and Salient Characteristics
Description
Part
Number Vendor Quantity
Unit of
Issue
Unit
Price Amount
Salient
Characteristics to be
Met
Attest
Rapid
Steam BI, or equivalent 1292-S 3M 65
600 /
Case $ $
Self-contained biological indicator;
Geobacillus stearothermophilus spore strip and sealed glass ampoule with growth indicator; 106 population; dual indicator system; ISO
11138-1:2017 and
ISO 1138-3:2017
compliant; chemical process indicator label; fluorescent result in 3 hours;
compatible with 3M
Attest 390 Auto-
Reader.
Comply
SteriGage
Steam
Chemical
Integrator, or equivalent 1243A 3M 150
1000 /
Case $ $
ISO 11140-1:2014
Type 5 Integrating
Indicator; moving front ink technology with "ACCEPT" and
"REJECT" zones that indicate whether process conditions necessary for sterilization were met
; scannable 2-D barcode containing lot code and expiration;
length 5.1cm; width:
1.9cm; for use in
121-135 C steam sterilization cycles.
RFQ 1232SA25Q0391
Attachment 1 – Schedule of Prices and Salient Characteristics
Delivery address: USDA NBAF
Attn: Amy Lyons/BRM
1200 Kretschmer Drive
Suite 100
Manhattan, KS 66502
Delivery schedule: We would like flexibility to request these in batches as needed over the 12-month period of performance. This delivery schedule will be mutually agreed upon by both parties.