RFP # 729 Aquatic Herbicide Admin Doc Amendment 2 MP 6-10-25.docx
DOCX document 291 KB Posted
- Attached to
- AQUATIC HERBICIDE APPLICATOR SERVICES
- Solicitation number
- 729
- Issued by
- Kootenai County, Idaho
About this file
This is an amendment document to RFP #729 for Aquatic Herbicide Applicator Services issued by the Idaho State Department of Agriculture (ISDA) Division of Purchasing. The solicitation seeks qualified contractors to supply and apply designated herbicides for treatment of Eurasian Watermilfoil and other aquatic noxious weeds in Idaho waters. The original proposal submission deadline was May 6, 2025. The contract will require contractors to demonstrate professional certification in herbicide application, environmental compliance, and adherence to safety protocols. Prospective vendors must possess expertise in precision herbicide application with consideration for environmental impact and integration with existing state infrastructure and maintenance systems.
Specific pricing terms, contract award value, and budget ranges are not explicitly detailed in the available documentation. No set-asides are identified in the file. The contract does not reference incumbent vendors. While standard Idaho state procurement practices may encourage participation from small businesses, disadvantaged business enterprises, and local vendors, no formal restrictions or preferences are stated. Contractors should anticipate performance requirements related to environmental regulations, safety standards, and technical specifications for aquatic herbicide application. The specific contract term and any renewal options are not addressed in the amendment document provided.
View the file
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
STATE OF IDAHO
DIVISION OF PURCHASING
FOR THE
IDAHO STATE DEPARTMENT OF AGRICULTURE
REQUEST FOR PROPOSAL
Aquatic Applicator Services RFP # 729 Amended 06/10/2025
TABLE OF CONTENTS
| RFP ADMINISTRATIVE INFORMATION | 1 | |
| 1 | OVERVIEW | 2 |
| 2 | QUESTIONS | 4 |
| 3 | INSTRUCTIONS FOR SUBMISSION OF PROPOSAL | 6 |
| 4. | PROPOSAL FORMAT | 8 |
| 5. | PROPOSAL REVIEW, EVALUATION, AND AWARD | 9 |
| 6. | MANDATORY SUBMISSION REQUIREMENTS | 12 |
| 7. | BUSINESS INFORMATION | 13 |
| 8. | ORGANIZATION AND STAFFING | 14 |
| 9. | SCOPE OF WORK | 15 |
| ATTACHMENT 1 – PRE-PROPOSAL CONFERENCE REGISTRATION FORM | 21 | |
| ATTACHMENT 2 – OFFEROR QUESTIONS | 22 | |
| ATTACHMENT 3 – MODIFICATION AND EXCEPTION FORM | 24 | |
| ATTACHMENT 4 – COVER FORM | 25 | |
| APPENDIX A – IDAHO TERMS AND CONDITIONS BACKGROUND AND LIMITATIONS | 28 | |
| APPENDIX B – REPORTS | 31 | |
| APPENDIX C – SPECIAL TERMS AND CONDITIONS | 32 |
RFP ADMINISTRATIVE INFORMATION
RFP Title:
Aquatic Applicator Services
RFP Project Description:
The Division of Purchasing (DOP), on behalf of the Idaho State Department of Agriculture (ISDA) , is seeking Aquatic Applicator Services Contractors to apply designated herbicides for the treatment of Eurasian Watermilfoil and other invasive species in waters of Idaho.
RFP Lead:
Michael Piccono, Purchasing Officer Division of Purchasing 650 West State St, RM 100, Boise, ID 83702 Michael.Piccono@adm.idaho.gov 208-332-1612
| Submitting Sealed Proposal Electronically via IPRO: |
| Electronic Submission: |
IPRO LOGIN
Pre-Proposal Conference Date/Time:
Pre-Proposal Conference Location:
Tuesday April 8th at 9:00 AM Mountain Time
Virtually on Microsoft Teams
Deadline to Receive Questions:
See IPRO Header
RFP Closing Date:
See IPRO Header
Public Opening Date:
The following business day after closing
Initial Term of Contract and Renewals:
Initial Term one and one half (1.5) years anticipated August 1, 2025 to Dec. 31, 2025. Upon mutual, written agreement, the Contract may be renewed, extended or amended. The anticipated total Contract term is June August 1, 2025 to December 31, 2030.
| RFP # 729 AQUATIC HERBICIDE APPLICATOR SERVICES |
| 2 |
OVERVIEW
1.1. Purpose
The Division of Purchasing (DOP), on behalf of the Idaho State Department of Agriculture (ISDA) , is seeking Aquatic Applicator Services Contractors to apply designated herbicides for the treatment of Eurasian Watermilfoil and other invasive plant and animal species in waters of Idaho. (See Areas A, B, and C on Attachment 6).
1.2. Definitions
AI – Active Ingredient APAP – Aquatic Pesticide Application Plan APAR – Aquatic Pesticide Application Report EWM – Eurasian watermilfoil FAA – Federal Aviation Administration NSDES – National Pollutant Discharge Elimination System PDMP – Pesticide Discharge Management Plan PGP – Pesticide General Permit USEPA – United States Environmental Protection Agency
1.3. Background Information
The project requires aquatic herbicide treatment of Eurasian watermilfoil (EWM) and other aquatic noxious weeds in the lakes and river systems of Areas A, B and C on Appendix D, State of Idaho Area Map. Herbicide treatments have historically been conducted for the treatment of Eurasian watermilfoil in four (4) waterbodies annually in Area A; Hayden, Cocolalla, Priest and Pend Oreille Lakes, however, ISDA needs to have the flexibility to be able to treat in other waters across the State of Idaho, if high levels of Eurasian watermilfoil or other aquatic noxious weeds are found.
The treatment acreage will be determined following aquatic plant surveys conducted during the spring of each year. ISDA estimates treatment acreage for aquatic noxious weeds, for the 2025 season, at two hundred (200) acres. At this time, most of the estimated treatment acreage is expected in Area A, with one annual treatment in Area B and one annual treatment in Area C. The need for treatments in all regions may emerge following annual aquatic plant surveys. All acreage estimates in this RFP are estimates only. There is no guarantee of annual acreage to be treated.
Aquatic noxious weed treatments will occur in water ranging from six (6) inches to forty-five (45) feet in water depth using injection hose or granular application that can deliver herbicide to the specific depths in the water column. Significant water exchange issues have been encountered in waterbodies across the State of Idaho in the past due to high water flow, high wind and wave action. Because of this, the Contractor needs to be flexible with the application schedule and must be able to adjust treatment schedules depending on lake and weather conditions. Due to water exchange conditions, Contractor also must have the capability to conduct application at night in order to maximize treatment efficacy during periods of calm conditions. Additionally, ISDA requires that the Contractor use drone application methods to treat bodies of water during spring drawdown periods when part of the lake bottom is exposed.
At ISDA’s discretion, the awarded Contractor for this service may be required to perform aquatic application services for the treatment of invasive mussels in lakes, ponds, or streams where they may be found. This would be in addition to the anticipated aquatic plant treatments. There is no minimum for this type of work.
The Contractor must coordinate with the ISDA on all treatment operations and must allow inspections and oversight by ISDA staff. ISDA will make the final determination for each treatment on the specific depth at which the specified herbicides will be delivered. Treatments will not be initiated until ISDA determines that conditions are acceptable for successful treatment. Herbicide residue analysis water testing will be conducted directly by ISDA and will not be required of the Contractor.
1.4. Resulting Contract
If the State awards a contract from this Solicitation, it will do so by issuing a Contract document from the State’s eProcurement system, IPRO POWERED BY LUMA, which will be an acceptance of the successful offer. The Contract will be comprised of that contract document; this RFP, including any incorporated documents; the successful Proposal, including any clarifications requested by the state of Idaho (State); and an artifact formalizing any requirements agreed upon through contract discussions or negotiations, if applicable.
The following documents are incorporated into this RFP as if set out in their entirety, whether or not they are attached in IPRO POWERED BY LUMA:
· Solicitation Instructions for Vendor
· Standard Contract Terms and Conditions
· Regional Map
· Licensing Table
If not attached in IPRO POWERED BY LUMA, the documents may be found on the “Information for Vendors” page of DOP’s website, www.purchasing.idaho.gov. If multiple versions of any of these documents are available on the website, the version in effect on the day the RFP was issued shall apply.
2.
QUESTIONS
2.1. Restrictions on Communications
From the issue date of this RFP, until a contract is awarded, or the RFP is cancelled, vendors are prohibited from communications regarding this RFP with the ISDA staff, evaluation committee members, or other associated individuals, except the Division of Purchasing.
2.2. Pre-Proposal Conference
A non-mandatory pre-proposal conference will be held at the location and time as indicated in Section 1, page 1 of this RFP. This will be your opportunity to ask questions, in person, with the ISDA staff. All parties interested are invited to participate either by attending the conference or by an established call in number. Those choosing to participate must pre-register to receive phone conferencing and meeting details by submitting the completed Attachment 1 - Pre-Proposal Conference Registration Form via email to the RFP Lead. Parties interested are asked to register by 5:00 PM Mountain Time Monday April 7th, 2025. Any oral answers given by the State during the pre-proposal conference are unofficial and will not be binding on the State. Conference attendance is at the participant’s own expense.
2.3. Questions
2.3.1. This solicitation is issued via the State’s e-Procurement system, IPRO POWERED BY LUMA. The RFP Lead is the only contact for this Solicitation. All correspondence must be in writing. In the event that it becomes necessary to revise any part of this RFP, amendments will be posted at IPRO. It is the responsibility of parties interested in this RFP to monitor IPRO for any updates or amendments. Any oral interpretations or clarifications of this RFP must not be relied upon. All changes to this RFP will be in writing and must be posted to IPRO to be valid.
2.3.2. Questions or other correspondence must be submitted in writing to the RFP Lead (see contact information in the RFP Administrative Information, page 1). QUESTIONS MUST BE RECEIVED BY 11:59:59 P.M. MOUNTAIN TIME ON THE DATE LISTED IN THE RFP ADMINISTRATIVE INFORMATION.
2.3.3. Written questions must be submitted using Attachment 2 - Offeror Questions. Official answers to all written questions will be posted on IPRO POWERED BY LUMA as an amendment to this RFP, DO NOT SUBMIT QUESTIONS VIA IPRO.
2.4. Vendor Proposed Modifications and Exceptions to Requirements, Terms, and Conditions
2.4.1. Vendors must submit any proposed modifications to the requirements, terms, or conditions of the RFP on Attachment 2 - Offeror Questions prior to the deadline to submit questions. Questions regarding these requirements must contain the following:
· The rationale for the specific requirement being unacceptable to the party submitting the question (define the deficiency).
· Recommended verbiage for the State’s consideration that is consistent in content, context, and form with the State’s requirement that is being questioned.
· Explanation of how the State’s acceptance of the recommended verbiage is fair and equitable to both the State and to the party submitting the question.
2.4.2. In the event that a Proposal contains modifications or exceptions to any Solicitation requirements, terms, or conditions which are not addressed during the question and answer period, they must be identified and submitted on Attachment 3 - Modification and Exception Form and must contain the same information outlined in Section 2.3.1, above. The State will not consider any modifications or exceptions that are not identified specifically on Attachment 3.
2.4.3. The State has sole discretion to determine if the modifications or exceptions submitted by an Offeror would result in a material change or otherwise threaten the integrity of the procurement process. See Appendix A - Idaho Terms and Conditions Background and Limitations. Pursuant to IDAPA 38.05.01.084.e, the State may only negotiate non-material modifications or exceptions. Modifications or exceptions which the State determines to be material, or which otherwise threaten the integrity of the procurement process, will not be accepted or negotiated. In the event that the Offeror has conditioned its Proposal on the State’s acceptance or negotiation of its proposed modifications or exceptions, and the modifications or exceptions are deemed material, the Offeror will be given the opportunity to retract the proposed modifications or exceptions from its Proposal. Failure to do so will result in the Offeror’s Proposal being found non-responsive, after which it will receive no further consideration.
2.4.4. Non-material modifications or exceptions may be discussed with the apparent successful Offeror, at the discretion of the State; however, the State shall have the right to reject any and all such modifications and/or exceptions, or to call an end to such discussions, and to instruct the Offeror to amend its Proposal and remove the modifications and/or exceptions. Failure to do so may result in the State finding the Proposal non-responsive.
2.4.5. Except as otherwise provided within the Solicitation, the State will not consider modifications or exceptions to the requirements, terms, or conditions which are proposed after the RFP Closing Date.
INSTRUCTIONS FOR SUBMISSION OF PROPOSAL
3.
3.1. General Instructions
3.1.1. Proposals must be submitted electronically, as detailed below. Except as otherwise addressed in this solicitation, all submission materials must be submitted at the same time (in a single package or electronic submission). If multiple submissions are received, only the latest timely submission will be considered.
3.1.2. Alternate proposals are not allowed.
3.1.3. All electronic files must be in Microsoft Word or Excel format; the only exception is for financials, brochures or other information only available in an alternate format.
3.1.4. It is mandatory to submit your Proposal electronically via IPRO POWERED BY LUMA, all Offerors participating in this Solicitation must establish an account in the IPRO system, as it is necessary in order to process and/or award the resulting Contract(s). Establishing an account is free and only takes a few minutes.
3.2. Trade Secrets
Paragraph 28 of the Solicitation Instructions to Vendors describes trade secrets to “include a formula, pattern, compilation, program, computer program, device, method, technique or process that derives economic value, actual or potential, from not being generally known to, and not being readily ascertainable by proper means by other persons and is subject to the efforts that are reasonable under the circumstances to maintain its secrecy.” In addition to marking each page of the document with a trade secret notation (as applicable; and as provided in Paragraph 28 of the Solicitation Instructions to Vendors), Offerors must also:
3.2.1. Identify with particularity the precise text, illustration, or other information contained within each page marked “trade secret” (it is not sufficient to simply mark the entire page). The specific information you deem “trade secret” within each noted page must be highlighted, italicized, identified by asterisks, contained within a text border, or otherwise clearly delineated from other text/information and specifically identified as a “trade secret.”
3.2.2. Provide a separate document entitled “List of Redacted Trade Secret Information” which provides a succinct list of all trade secret information noted in your Proposal; listed in the order it appears in your submittal documents, identified by Page #, Section #/Paragraph #, Title of Section/Paragraph, specific portions of text/illustrations; or in a manner otherwise sufficient to allow the State’s procurement personnel to determine the precise text/material subject to the notation. Additionally, this list must identify with each notation the specific basis for your position that the material be treated as exempt from disclosure and how the exempting the material complies with the Public Records Law.
3.2.3. Submit a redacted copy of the Proposal with all trade secret information removed or blacked out. The redacted copy must be submitted electronically, with the word “redacted” in the file name, whether the Proposal is submitted manually or electronically.
3.3. Electronic Submission
3.3.1. Electronically submitted Proposals must be submitted through IPRO POWERED BY LUMA. When submitting through IPRO, enter your Cost in IPRO as “$0.01,” and UPLOAD YOUR TECHNICAL PROPOSAL, SEPARATE COST PROPOSAL, AND ALL OTHER REQUIRED SUBMITTAL ITEMS. Remember to submit an additional redacted version of the proposal if you have identified trade secrets.
3.3.2. Vendors are strongly encouraged to begin the process of submitting the response far enough in advance of the End Time to allow for resolution of technical difficulties. Be advised that the state is not responsible for a Vendor’s failure to timely submit a responsive submission due to any technical or technological difficulties. See IDAPA 38.05.01.61.02.
3.3.3. Submitting via IPRO POWERED BY LUMA, be advised that the Offeror for Proposal evaluation and award purposes is the entity profile under which the Proposal is submitted in IPRO, which must be the same legal entity presented in the uploaded response materials. If the entity identified on the state supplied Signature Page differs from the entity under which you submit your Proposal in IPRO, the information provided on the Signature Page prevails.
3.3.4. Offerors are further advised to upload response materials with descriptive file names, organized and consolidated in a manner which allows evaluators to efficiently navigate the Offeror’s response; as the State will print uploaded documents for evaluation in the manner received via IPRO.
4. PROPOSAL FORMAT
1.
2.
3.
These instructions describe the format to be used when submitting a Proposal. The format is designed to ensure a complete submission of information necessary for an equitable analysis and evaluation of submitted Proposals. There is no intent to limit the content of Proposals.
4.1. Table of Contents
Include a table of contents in the Technical Proposal identifying the contents of each section, including page numbers of major Sections.
4.2. Format
Proposals shall follow the numerical order of this RFP beginning with Section 6 and continuing through the end of the applicable RFP Attachments, including all mandatory submission items detailed in Section 6 and identified throughout the RFP. Proposal sections and subsections must be identified with the corresponding numbers and headings used in this RFP. In your response, restate the RFP section and/or Section, followed with your response.
Offerors are encouraged to use a different color font, bold text, italics, or other indicator to clearly distinguish the RFP section from the Offeror’s response. Except for brochures, financials, work samples, or other similar submission items, all electronic Proposals must be submitted in Microsoft Word or Excel, and must not be locked. Offerors are strongly cautioned against including website links or imbedded documents in the Proposal (Except where required in Scope of Work Section 9.6 Website); the State will not be responsible for the RFP Lead or any evaluator’s failure to consider information outside of or imbedded in the Proposal.
4.3. Evaluation Codes
(M) Mandatory Response - failure to respond to any (M) section, or to comply with any mandatory specification or requirement, will render Offeror’s Proposal non-responsive and no further evaluation will occur.
(ME) Mandatory and Evaluated Response - failure to respond to any (ME) section, or to comply with any mandatory specification or requirement in an (ME) section, will render Offeror’s Proposal non-responsive and no further evaluation will occur. Offeror must respond to these sections as directed; points will be awarded based on predetermined criteria.
(E) Evaluated Response - a response is desired and will be evaluated. If Offeror cannot meet the requirement, or chooses not to respond for any reason, zero (0) points will be awarded for the section. If Offeror responds, points will be awarded based on predetermined criteria.
Note: Offerors are directed to IDAPA 38.05.01.074.03.a, as well as IDAPA 38.05.01.091.05, which allow the designated State official to waive minor informalities as well as minor deviations. The State also reserves the right to seek clarification on any (M), (ME), or (E) requirement.
5. PROPOSAL REVIEW, EVALUATION, AND AWARD
4.
5.1. Overview
The objective of the State in soliciting and evaluating Proposals is to ensure the selection of a firm or individual that will produce the best possible results for the funds expended.
5.1.1. All Proposals will be reviewed first to ensure that they meet the Mandatory Submission Requirements of the RFP as addressed in Sections noted with an (M) or (ME). Any Proposal(s) not meeting the Mandatory Submission Requirements will be found non-responsive.
5.1.2. Evaluation Criteria
Technical Proposal:
| Mandatory Submission Requirements | Pass/Fail | |
| Business Information (Section 7) | 150 points | |
| Organization and Staffing (Section 8) | 250 points | |
| Scope of Work (Section 9) | 400 points | |
| (Demonstrations If Conducted) | 200 Points | |
| Cost Proposal | 200 points | |
| TOTAL POINTS | 1,000 points | |
| (Total Points if Demonstrations are Conducted) | 1,200 points |
1.
2.
3.
4.
5.
5.1.
5.2. Technical Proposal
5.2.1. The Technical Proposal will be reviewed first on a “pass” or “fail” basis to determine compliance with those requirements listed in the RFP with an (M) or (ME). All Proposals which are determined by the State, in its sole discretion, to be responsive in this regard will continue in the evaluation process outlined in this Section.
5.2.2. The Technical Proposal will be evaluated and scored utilizing one (1) or more Technical Proposal Evaluation Committee(s).
5.2.3. The scores for the Technical Proposal will be normalized as follows: The Technical Proposal with the highest raw technical score will receive all available Technical Points: 800 points. Other Proposals will be assigned a portion of the maximum available Technical Points, using the formula:
800 X raw score of technical Proposal being evaluated highest raw technical score.
5.3. Presentations
At the State’s option, up to three (3) Offerors, with the highest raw score after the evaluation of the Technical Proposal is complete, may be asked to make presentations. If the State holds presentations, they will be mandatory for all invited Offerors and will be evaluated.
5.3.1. The scores for the Presentations will be normalized as follows: The Presentation with the highest raw score will receive all available Presentation Points: 200 points. Other Offerors will be assigned a portion of the maximum available Presentation Points, using the formula:
200 X raw score of Presentation being evaluated highest raw Presentation score.
5.4. Cost Proposal
5.4.1. The Cost Proposal will only be opened and evaluated for Offerors who receive the top three technical scores. The Offeror must provide a fully-burdened, all-inclusive cost for each item of the Cost Proposal (Attachment 5).
5.4.2. The scores for the Cost Proposal will be normalized as follows: The cost evaluation will be based on the Total Cost of Projects on the Evaluation Projects that ISDA has created for evaluation purposes only (see sample provided on Attachment 5 Cost Proposal. The costs each offeror provides in Attachment 5 Cost Proposal shall be entered into the same Evaluation Projects for evaluation. Offerors will not be informed which units, pricing, herbicides, and areas will be used in evaluation prior to submitting their proposal. These evaluation projects will be blind to offerors and will be finalized by ISDA prior to the RFP Close Date.
5.4.3. The Proposal with the lowest overall Total Cost of Projects proposed will receive all available Cost Points: 200 points. Other Proposals will be assigned a portion of the maximum available Cost Points using the formula:
200 X Lowest overall Total Cost of Projects______ Overall Total Cost of Projects being evaluated.
5.5. Responsibility
Pursuant to IDAPA 38.05.01.081, the RFP Lead may, in the State’s sole discretion, require the apparent high point Offeror to provide documentation to demonstrate its responsibility. The RFP Lead may request documentation including, but not limited to: credit or financial reports, and references. Failure to provide requested documentation may result in the Offeror being deemed non-responsible. Nothing herein shall prevent the State from using other means to determine Offeror’s responsibility.
5.6. Award
Award of Contract will be made to the responsive, responsible Offeror whose Proposal receives the highest number of total normalized points.
5.7. Contract Term
The Contract resulting from this RFP is anticipated to begin June 1, 2025August 1, 2025. The initial term shall be one and one half (1.5) years. Upon mutual, written agreement, the Contract may be renewed, extended or amended. The anticipated total Contract term is August 1, 2025June 1, 2025 to December 31, 2030.
5.8. Billing
Invoice frequency: The Contractor must submit its invoice within thirty (30) calendar days after treatment conclusion. Invoices must include: contract number, date of treatment, area of treatment, number of acres treated, chemical used, price per acre.
Invoices are to be sent to:
Idaho State Department of Agriculture ATTN: Division of Plant Industries, Jeremey Varley PO Box 7249 Boise, ID 83707 Email : Jeremey.Varley@isda.idaho.gov
6. MANDATORY SUBMISSION REQUIREMENTS
The technical proposal begins with the mandatory items identified in this list and the following sections. NOTE: THIS CHECKLIST IS PROVIDED AS A COURTESY ONLY; OFFERORS ARE RESPONSIBLE FOR SUBMITTING ALL MANDATORY SECTIONS, ATTACHMENTS, SUBMITTAL ITEMS, ETC., REGARDLESS OF WHETHER THEY ARE IDENTIFIED IN THIS LIST.
☐ (M) Signature Page: All Proposals must be submitted with a state supplied Signature Page, attached separately in IPRO POWERED BY LUMA. For electronically submitted Proposals, submit a completed, scanned signature page. Your ORIGINAL Signature Page should be included at the FRONT of your ORIGINAL Technical Proposal
☐ (M) Cover Form: Complete, sign, and submit Attachment 4, Cover Form.
☐ (M) Acknowledgement of Amendments: If the RFP is amended, the Offeror must acknowledge each amendment with a signature on the acknowledgement form provided with each amendment or by acknowledging the Mandatory Question on IPRO powered by LUMA for each Amendment. Failure to return a signed copy of each amendment acknowledgement form with the Proposal may result in the Proposal being found non-responsive. See IDAPA 38.05.01.52.
☐ Section 7: Provide response to all (M) and (ME) sections, and any other required submittal items.
☐ Section 8: Provide response to all (M) and (ME) sections, and any other required submittal items.
☐ Section 9: Provide response to all (M) and (ME) sections, and any other required submittal items.
☐ (ME) Cost Proposal: Provide your cost information on the form provided in Attachment 5, Cost Proposal. Submit the Cost Proposal in a separately uploaded file or separately sealed envelope.
☐ Redacted copy of Technical Proposal and list of Trade Secret redactions, as detailed in Section 3.2.
☐ Review the required types and levels of insurance—these are mandatory requirements. If you do not already have the required types and levels of insurance, you are strongly encouraged to contact your insurance representative to find out if you will be able to obtain the required insurance. (The Offeror should not purchase additional insurance in reliance of being awarded a contract). If you are awarded a Contract, failure to provide proof of the required insurance will be grounds for termination of the Contract.
7. BUSINESS INFORMATION
6.
7.
7.1. (ME) Business Profile Provide a profile of your business including Offeror’s business history, description of current service area, and customer base.
7.2. (ME) Experience Describe in detail your knowledge and experience in providing services similar to those required in this RFP. Offeror must have a minimum of three (3) years of experience successfully completing herbicide treatments in partnership with State Governments or other Public Agencies.
7.3. (M) Organizational Chart Provide a copy of your organizational chart, including detail of any relationships with parent and subsidiary organizations.
7.4. (ME) Demonstrated Success Provide specific data demonstrating previous success with at least one watercraft application and one drone application.
8. ORGANIZATION AND STAFFING
Describe your qualifications to successfully complete the requirements of the RFP by providing a detailed response to the following:
8.
8.1. (ME) Project Lead Identify the person who will be the dedicated Project Lead if Offeror is awarded a contract. Provide a description of the proposed Project Lead’s experience and qualifications. You may submit a resume in response to this section.
8.2. (ME) Key Personnel and Qualifications Provide a list of key management, customer service and other roles to be used in the fulfillment of this Contract (in addition to the Project Lead). Provide role descriptions, including requisite qualifications and experience of the person(s)/role(s) identified, as well as an explanation of how the person in that role will contribute to the project. Your response should demonstrate the extent to which you have the expertise to accomplish the Scope of Work.
8.3. (M) Subcontractors If you intend to utilize subcontractors, describe the extent to which they will be used to comply with Contract requirements. Include each position providing service, and provide a detailed description of how the subcontractors are anticipated to be involved under the Contract. Include a description of how the Offeror will ensure that all subcontractors and their employees will meet all Scope of Work requirements. NOTE: The information provided for subcontractors, if any, will be evaluated as part of Section 8.2, Other Key Personnel and Qualifications.
If you do not intend to utilize subcontractor(s), provide a statement to that effect.
9. SCOPE OF WORK AMENDED 06/10/2025
All sections of the Scope of Work are required contract services. Use this Proposal outline as part of your response to the RFP. Keep in mind, the evaluators will be scoring your Proposal based on the methodologies proposed and the completeness of the response to each item listed below. You must describe in detail how you will meet each requirement marked (M) or (ME) below. Include personnel, proposed timelines, methodologies, and any pertinent information that will be required from the Agency in order to achieve full compliance with all tasks and deliverables.
9.1. (M) Certified Service Provider The Offeror must be a certified aquatic herbicide applicator in the State of Idaho. Offeror must provide a response to the following with their proposal:
Offeror must upload a copy of their company’s certified aquatic herbicide applicator license and a signed letter attesting to your company’s certification with their proposal. The letter must be signed by a ranking officer in the company who is submitting the proposal and is authorized to make such a declaration of certification. The letter must also contain language that indicates that by signing the document the author is authenticating that the certifications being made in the letter are true and accurate.
Offeror must refer to Appendix D for the Licensing Table. Offeror must upload each License and Certification listed that they have attained.
9.2. (ME) Application Equipment
9.2.1. ISDA shall make the final determination for each treatment on the specific depth, at which the specified herbicides will be delivered. At a minimum the Contractor must provide application equipment that is properly calibrated to deliver liquid herbicides at a high label rate to a specific depth in the water column to depths ranging from approximately six (6) inches to forty five (45) feet water depth. At a minimum this must include a real time GPS enabled treatment system that allows us to track the flow rate of the chemical and proximity within application area to track in water as prescribed by ISDA.
Describe how you will provide application equipment that is properly calibrated to deliver liquid herbicides at a high label rate to a specific depth in the water column to depths ranging from approximately six (6) inches to forty five (45) feet water depth.
Describe how you will provide application equipment that is properly calibrated to deliver granular herbicides to a waterbody.
Describe how you will provide a drone operating system that will, at minimum, record flight height, flight direction, relative flight data and application information such as rate and record where it is located in designated work areas.
Describe what form of active application tracking platforms/software your company is utilizing and what reports are generated from the use of the platform/software.
Demonstrate the extent to which your company is experienced in completing treatments using innovative treatment methods. These may include: lit line or benthic depth delivery systems, drip totes, and shallow water, less than 3 feet deep; for all applications the use of flow meters and tracking equipment to ensure accuracy of all prescribed herbicide applications; for drawdown applications methodologies and practices to effectively treat those areas during effective season
9.2.2. ISDA requires that the Offeror utilize an active electronic method of application monitoring, recording, and reporting that is equivalent to the Raven Viper Pro software/platform.
Note: The brand names referenced in this section are intended to be descriptive, but not restrictive and are used to indicate the quality and characteristics of the software//platform that will be satisfactory. The software/platform must actively record rates of application, application speeds, and GPS logs when applications are being made and track of travel.
Describe methods/technology used to deliver herbicide to specified water depths.
Describe in detail how application equipment is used during application to ensure herbicide is being delivered consistently to a specific depth in the water column over treatment areas that have various water depths as well as tracking when herbicide was applied and when it was not.
Describe in detail how your company (or your subcontractor) will implement a drone treatment over a drawn-down lakebed or similar surface and how you will provide application equipment that is properly calibrated to deliver liquid herbicides at a high label rate to a specific target location.
9.2.3. Two weeks prior to each application, ISDA will provide the Contractor with a Pre-Launch Checklist. The Contractor must demonstrate to the ISDA Project manager that your company’s equipment is installed and operational in accordance with this checklist prior to each project application. If the equipment does not meet all of the requirements in this Checklist the treatment may be postponed or cancelled at the discretion of ISDA. Contractor must also provide documentation of calibrations on application equipment, prior to work beginning.
9.3. Drone Operation Requirements
Contractor must maintain a FAA Drone Operator’s License.
9.3.1. If drone weight is less than fifty-five (55) pounds, if can be a Part 107 license.
9.3.2. If drone weight is greater than fifty-five (55) pounds, then the operator needs a full pilot’s license based on Federal FAA regulations. The operator license, FAA certificate, and FAA registration must be provided at time of proposal as part of your response to Section 9.1.
9.3.2.1. Drone equipment must be properly registered with the FAA.
9.3.2.2. Contractor must maintain required Aerial Application Pesticide License.
9.4. (ME) GPS/GIS Systems
9.4.1. Contractor must use GPS/GIS systems to produce and utilize shapefiles to accurately apply herbicides to designated treatment areas
9.4.2. ISDA requires the Contractor to utilize an active electronic method of application monitoring, recording, and reporting with outputs compatible with ESRI type files.
Provide a list of GPS and navigation equipment to be used and describe how this equipment is integrated into application equipment.
Note: The brand names referenced in this section are intended to be descriptive, but not restrictive and are used to indicate the quality and characteristics of the software/platform that will be satisfactory. The software/platform must actively record rates of application, application speeds, and GPS logs when applications are being made and track of travel.
9.4.3. The ISDA will provide polygons indicating treatment areas to the Contractor prior to treatment. The Contractor must evaluate this information and provide comment/recommendations to the ISDA on ways to make the treatment more effective and efficient.
9.4.4. Contractor must provide shapefiles of the treatment tracks (where herbicide was actively delivered to the waterbody as well as the track of the application vessel) to the ISDA following treatment.
Describe how you will use GPS/GIS systems to produce and utilize shapefiles to accurately apply herbicides to designated treatment areas.
9.5. (M) Herbicides
9.5.1. Contractor must provide the following aquatically labeled herbicides, to include coordinating herbicide delivery, arranging, staging and loading areas for each project:
9.5.1.1. liquid Triclopyr (44.4% active ingredient (AI) or greater);
9.5.1.2. liquid 2,4-D (46.3% AI or greater);
9.5.1.3. liquid Fluridone (41.7% AI or greater);
9.5.1.4. granular Fluridone (5% AI or greater);
9.5.1.5. liquid Endothall (40.3% AI or greater);
9.5.1.6. powder Flumioxazin (51% AI or greater);
9.5.1.7. liquid Florpyrauxifen-benzyl (2.7% AI or greater);
9.5.1.8. liquid Penoxulam (21.7% AI or greater);
9.5.1.9. liquid Imazamox (12.1% AI or greater);
9.5.1.10. Carfentrazone-ethyl (21.3% AI or greater);
9.5.1.11. liquid Diquat (37.3% AI or greater); and
9.5.1.12. Liquid Imazapyr (27.7% AI or greater).
ISDA will specify which herbicide will be used for each treatment project prior to treatment.
Contractor must provide the MSDS or SDS and manufacturer label with their proposal (attached separately from the Technical Proposal in IPRO powered by Luma), for each herbicide specified in Attachment 5 Cost Proposal. These will be reviewed on a pass or fail basis for compliance. The Herbicides bid on Attachment 5 Cost Proposal shall be the herbicides required in performance of the contract unless otherwise approved in writing by the Idaho State Department of Agriculture.
9.6. (ME) Website
9.6.1. Contractor must provide a website which must provide accurate and timely information regarding treatments and treatment planning.
Describe how you will provide a website to post information to the public regarding treatment schedules, treatment areas, and general herbicide and treatment information.
Provide example(s) of websites. A link to each sample website is acceptable.
9.7. Treatment Notices
The Contractor must:
9.7.1. Hand deliver treatment notices to shoreline residents within a minimum of 0.25 miles of the treatment area a minimum of two (2) weeks prior to treatment.
9.7.2. Post docks, boat launch areas, shorelines and swim areas within a minimum of 0.25 miles of the treatment area a minimum of twenty-four (24) hours prior to treatment.
9.7.3. If herbicide label restriction requirements exceed 0.25 miles, then door-to-door posting and dock / shoreline posting will be extended to include all areas included in water use restriction area. Notifications will follow guidelines outlined in the following Guidelines for Herbicide Treatment Posting:
9.7.3.1. Public notice procedures:
9.7.3.1.1. Notification must inform affected persons about the project in general and let them know which chemical will be used to treat aquatic weeds; when the application will occur; and any water use restrictions found on the label. The notification must also include contact information, such as the name, phone number of the project sponsor, and provide a website address to provide additional information. ISDA will provide an electronic file of the posting notice. The successful Offeror is responsible for verifying information on the notice, as well as the printing and distribution of the notices.
9.7.3.1.2. Notification must be accomplished by hand delivery to structural living units located on individual parcels of shoreline properties a minimum of two (2) weeks prior to treatment. The successful Offeror must provide an address list for all recipients of notices to ISDA within 2weeks after delivery.
9.7.3.1.3. Signs must also be posted adjacent to the treatment area(s) a minimum of twenty-four (24) hours prior to treatment within a minimum of 0.25 miles of treatment areas. The signs must provide a brief description of the project including: project purpose; chemical used; any applicable water use restrictions; and the name and phone number of the project sponsor. At a minimum, posting must occur approximately every two hundred (200) feet along the shoreline of the treatment area or otherwise on trees or docks adjacent to the water body’s treatment area. Signs must also be posted at public access points around the water body. Signs must be posted in visible locations and must be posted in a manner so that they will remain in place and visible throughout the treatment and water use restriction period.
9.7.3.1.4. All NPDES and PGP posting requirements must be followed.
9.7.3.1.5. Contractor’s message on all dockside and dwelling postings must contain the same information as provided in notices sent by ISDA to all registered water rights holders via certified mail.
9.7.3.2. The Contractor must follow all provisions outlined in the EPA Pesticide General Permit (PGP) outlined in Section 7.3.
9.7.3.3. In all treatment situations, the current notification procedures outlined on the Idaho Department of Environmental Quality website at the time of the treatment will apply.
9.8. (ME) Schedule The Contractor must:
9.8.1. Allow for a flexible treatment schedule where application may be delayed or rescheduled due to weather and flow conditions.
Provide a response demonstrating how Contractor shall meet this requirement.
9.8.2. Provide nighttime applications. Treatments must be conducted at night unless otherwise directed by the ISDA. Treatment at night is intended to avoid daily wind patterns and to reduce wind induced water exchange impacts to the treatment.
Provide a response demonstrating how Contractor shall meet this requirement.
9.9. Contractor Representation
The Contractor must provide a knowledgeable representative to be present at up to three (3) public meetings per calendar year, if required, to help educate the public on the details of the herbicide application.
9.10. (ME) Sample Aquatic Pesticide Application Plan and Report (APAP and APAR) Provide a sample of a plan (APAP) from a previous treatment illustrating timeline for mobilizing and initiating herbicide applications. From the same treatment provide a sample report (APAR) as outlined in section 9.11.
9.11. Reports/Records/Documentation
The Contractor must provide an application plan (APAP) forty-eight (48) hours after receiving prescription from ISDA and a final report (APAR) to ISDA, electronically, within forty-eight (48) hours of the completion of each application. This report must, at a minimum, meet pesticide application record keeping requirements as stated in IDAPA 02.03.03 Application Records, Subsection 101 and include detail regarding treatment rates in each treatment area, volume of herbicide used in each treatment area, copies of application logs, corresponding shapefiles, and a detailed overview of the entire project including all items required in the Scope of Work.
9.12. Quality Assurance
The Contractor must allow for ISDA staff to provide oversight throughout the herbicide loading and application process for each application. ISDA shall make the final determination on the specific treatment schedule, rates, herbicide, herbicide volume and application depth for each treatment project prior to treatment.
9.13. NPDES Requirements
The Contractor must provide and retain all documents related to NPDES requirements for three (3) years. All NPDES requirements must be followed as stated in the EPA Pesticide General Permit including but not limited to adhering to the ISDA Notice of Intent (NOI) and Pesticide Discharge Management Plan (PDMP). The applicator is responsible for updating the PDMP for each treatment waterbody and must provide the PDMP to ISDA for review prior to treatment. The Contractor must review NPDES documents for accuracy and consistency following award of the contract.
9.13.1. In all treatment situations, the current notification procedures outlined on the Idaho Department of Environmental Quality website at the time of the treatment will apply.
9.14. Federal, State, and Local Requirements
Contractor must comply with all Federal, State, and local laws and requirements, including but not limited to:
9.14.1. United States Environmental Protection Agency (USEPA)
9.14.2. National Pollutant Discharge Elimination System (NPDES)
9.14.3. Pesticide Discharge Management Plan (PDMP)
9.14.4. Pesticide General Permit (PGP) Permit related information is included in the Aquatic Pesticide Application Plan (APAP) and submitted to ISDA prior to treatment.
9.15. (ME) Spill and Link Prevention The Contractor must be responsible for the organization and coordination of the herbicide product delivery, arranging for herbicide staging, loading areas, project cleanup and container disposal, as well as a risk management and response plan for chemical spills, and must perform these functions in accordance with Idaho Statute IDAPA 02.03.03 Rules Governing Pesticide and Chemigation Use and Application.
Describe how this will be accomplished for this project. Describe all application equipment and methods that are used to improve application accuracy, application efficiency and safety and spill/leak prevention as this pertains to both aquatic applications (on-water) and drone applications. Depending on herbicide type, minimum spill or leak prevention plans must meet pesticide label requirements.
9.16. (ME) Quagga Treatments ISDA reserves the right under this contract to utilize the Contractor for application services for the treatment of invasive mussels in lakes, ponds, or streams where they may be found. This work would be in addition to the anticipated aquatic plant treatments. There is no minimum or maximum amount guaranteed or implied for this type of work.
9.16.1. Agency Responsibilities
9.16.1.1. For quagga mussel treatments, ISDA will lead the application planning and pesticide selection. Specifically, ISDA will be responsible for treatment planning and selecting products.
9.16.1.2. If a treatment is determined by ISDA to be necessary, the treatment prescriptions will be provided to the Contractor at the time of implementation.
9.16.1.3. ISDA will provide a treatment calendar for Contractor activities. The treatment completion timeframe will be determined at the discretion of ISDA.
9.16.1.4. ISDA will provide warehousing for pesticides during any Quagga treatment response.
9.16.1.5. ISDA will handle site security during any Quagga treatment response.
9.16.1.6. ISDA will coordinate with other state or federal agencies, if necessary, to provide logistical assistance for the response.
9.16.2. Contractor Responsibilities
9.16.2.1. The Contractor must meet with the ISDA Point of Contact for a pre-treatment conference. The Contractor must be responsible for all application services, including the provision of treatment products, equipment and supplies.
9.16.2.2. Contractor must be responsible for transportation of pesticides/ chemical required for application to and from the warehouse and/or staging sites. Contractor is responsible for having the proper equipment to load and unload supplies. ISDA may provide equipment and an operator to assist in loading and unloading supplies, if equipment is available, including but not limited to: forklifts, telehandlers, trucks, and trailers.
The Contractor must complete set up, treatment, and take down activities according to the treatment calendar provided by the agency.
9.16.2.3. If the treatment product is being supplied in totes, the Contractor must provide all connections for the totes in the quantities required, including, but not limited to, hoses, pumps, and metered gravity boxes.
9.16.2.4. If watercraft are required for the treatment, the Contractor is responsible for providing and transporting the watercraft and all required treatment equipment for their watercraft to complete the treatment. In some situations where access requires use of Helicopter to launch or retrieve watercraft, ISDA will provide and coordinate such service. Such service must only be required if approved in writing by ISDA prior to initiating services.
9.16.2.5. All Contractor personnel must be qualified (licensed and certified) in order to be at the treatment sites. Required qualifications include:
9.16.2.6. Current, valid Pesticide Applicator License for all applicators
9.16.2.7. Mixing & Loading Certificate for Hazardous Material for all mixers & loaders
Describe your experience completing treatments for water-based invasive mollusks. Describe your experience using metered drip boxes or float systems to apply targeted amounts of pesticide into flowing water systems. At a minimum this should be metered float boxes targeting 1 to 25 oz per minute, demonstrating an understanding of how to calibrate and target key mixing sites to ensure accuracy. Describe all application equipment and methods that are used to improve application accuracy, application efficiency and safety and spill/leak prevention as this pertains to aquatic applications (on-water) and tote-based applications. Depending on pesticide type, minimum spill or leak prevention plans must meet pesticide label requirements.
9.17. (M) Quagga Molluscicides
9.17.1. Contractor must provide the following aquatically labeled molluscicides to include coordinating pesticide delivery, arranging, staging and loading areas should a project be required:
9.17.1.1. Natrix (EPA Reg # 67690-81)
9.17.1.2. Earthtec QZ (EPA Reg # 64962-1)
ISDA will specify which molluscicide will be used for each treatment project prior to treatment. ISDA may also specify the use of additional non-EPA registered products, should the need arise and will coordinate all Section 18 EPA exemptions for the use of products specific to each treatment area. For the purposes of this contract the products listed above are currently the only 2 registered products for use in Idaho for the treatment of Quagga and Zebra Mussels.
Contractor must provide the MSDS or SDS and manufacturer label with their proposal (attached separately from the Technical Proposal in IPRO powered by Luma), for each molluscicide specified in Attachment 5 Cost Proposal. These will be reviewed on a pass or fail basis for compliance. The Molluscicides bid on Attachment 5 Cost Proposal shall be the molluscicides required in performance of the contract unless otherwise approved in writing by the Idaho State Department of Agriculture.
ATTACHMENT 1 – PRE-PROPOSAL CONFERENCE REGISTRATION FORM
RFP…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .