Summary
This is a Request for Proposals (RFP) issued by the City of Summerville, Georgia for the design and construction of a 3,464 square foot sports-themed splash pad facility. The project requires qualified aquatic recreation and splash pad design-build firms to provide turnkey services including design, engineering, equipment procurement, site preparation, excavation, installation, and commissioning. The facility must feature durable poly-coated FunForm play elements from Water Odyssey/Fountain People, Inc., a modern flow-through water management system, a reinforced concrete slab with slip-resistant broom-finish and UV-stable polyurea safety coating, and interactive sports-inspired spray features suitable for users of all ages while maintaining ADA accessibility. A pre-bid conference is scheduled for May 21, 2026 at 10:30 a.m. at Summerville Parks and Recreation. Sealed proposals must be received by 10:00 a.m. on June 8, 2026, with proposals to be opened at 2:00 p.m. the same day. The deadline for submitting inquiries is May 26, 2026. Proposals must remain valid for 60 business days. The selected contractor shall be determined through evaluation of qualifications and proposal content, with price considered but not as the sole determining factor.
Bidders are required to submit a signed proposal with a 5% bid bond along with a Certificate of Non-Discrimination, E-Verify Compliance Affidavit, SAVE Compliance Affidavit, W-9 form, Certificate of Insurance, and Contractor Affidavits for any subcontractors. The successful respondent must maintain comprehensive general liability insurance in the amount of $1,000,000 per occurrence and per person, as well as vehicle liability insurance with minimum combined single limits of $1,000,000 per occurrence. The scope of work specifies minimum required spray features manufactured exclusively by Water Odyssey/Fountain People, Inc., including distribution manifolds, sequencing controllers, and various themed aquatic components such as the Crookett spray feature, Batter-Up and Goal spray features, Jet Way, Water Rail, Water Flower, drainage systems, and bucket features. The City reserves the right to reject all submissions, cancel the solicitation, and make awards in its sole discretion.
View the file
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
RFP-2026-126-Recreation Splash Pad
City of Summerville P. O. Box 180. Summerville, GA 30747
Phone: 706-859-0900
Web: http://www.summervillega.org
CITY OF SUMMERVILLE
REQUEST FOR PROPOSALS
Recreation Facility Splash Pad
Sealed proposals will be received by the City of Summerville, 120 Georgia Ave., Summerville, Georgia 30747 until 10:00 a.m. on 06/08/2026 for a 3,464 square feet flow-through Splash Pad. All proposals must be good for 60 business days. All proposals are subject to the provisions of the conditions outlined in this document. Proposals shall be opened promptly on the same day at 2:00 p.m. at the City Hall, Council Room, and their contents will be made public for the information of the Respondents, and others properly interested. The proposals will not be awarded until the applicable designated city officials have had ample time to review each proposal. Proposals must be submitted in sealed envelopes with "RFP-2026-126-Recreation Splash Pad" clearly marked on the outside of the envelope for easy identification by the City of Summerville. Any proposals received later than the specified time will not be accepted/considered. The City will not be responsible for late submissions caused by the postal service, other carriers, or any other delivery problems regardless of the reason.
Proposals submitted by USPS should be addressed to:
City of Summerville
PO Box 180
Summerville, GA 30747
ATTN: PURCHASING AGENT
Proposals submitted by Federal Express, United Parcel Services, etc. and should be addressed to: City of Summerville
120 Georgia Ave
Summerville, GA 30747
ATTN: PURCHASING AGENT
http://www.summervillega.org/
The City of Summerville reserves the right to engage in discussions with or request additional information from any or all responsible Respondents who submit proposals which appear to be eligible for the award, for the purpose of clarification to assure full understanding of and responsiveness to the RFP requirements herein. In the event the City elects to negotiate a contract with the successful vendor, any contract shall contain, at a minimum, the term and conditions (or substantially the same term and conditions) as hereinafter stated. The City reserves the right, in its sole discretion, to reject all submissions, reissue a subsequent RFP, terminate, restructure or amend this procurement process at any time. The final selection and contract negotiation rest solely with the City.
This solicitation does not commit the City of Summerville to award a contract/purchase order, to pay any costs incurred in the preparations of a proposal, or to procure or contract for services. The City of Summerville reserves the right to reject any and all responses, to cancel this solicitation, and to make an award deemed in its own best interest.
INSTRUCTIONS FOR PROPOSALS:
All Proposals must include:
1. Signed Proposal
2. Signed Certificate of Non-Discrimination
3. Signed E-Verify Compliance Affidavit
4. Signed Save Compliance Affidavit
5. Request for Taxpayer I.D. Number (W-9)
6. Certificate of Insurance
7. Contractor Affidavit (If using Sub-Contractors, we require a Contractor Affidavit from each Sub-Contractor)
8. Bid Bond Required: 5%
Signed Proposals
All proposals must be signed by an authorized officer or agent of the company submitting the proposal and delivered in sealed envelopes to City Hall no later than the time and dates indicated above. Proposals received after the time and date indicated above will not be considered. Faxed proposals will not be accepted under any circumstances. The City will assume no responsibility for oral instructions or suggestions. All official correspondences in regard to the specifications should be directed to and will be issued by the designated
City official. No oral statement of any person shall modify or otherwise change, or affect the terms, conditions or specifications stated in the resulting contract. The City of
Summerville shall not be legally bound by any amendment or interpretation that is not in writing. The City will rank, based upon the evaluation criteria, all responsible and responsive vendors.
The City will begin negotiations with the top-ranked vendor or vendors and will continue with negotiation down the ranking until a satisfactory contract with the City is finalized if any. The terms and conditions of the contract will be no less advantageous than the provisions of the RFP or the Vendor's proposal. The City reserves the right to make a partial award or to split the award at its sole discretion.
DEFINITIONS:
Responsible Respondent means a respondent who has the capability in all respects to fully perform contract requirements and the integrity and reliability, which will assure good faith performance.
Responsive Respondent means a respondent who has submitted a bid, which conforms in all material respects to the Request for Proposal.
CHANGES:
Any changes to the specifications in this request for proposal package shall be in writing and an addendum will be distributed to all prospective respondents so each respondent can compete equitably.
Any changes in this request for proposal after the purchase order/contract agreement has been awarded must be with the written consent of the designated city official or the City
Manager; otherwise, the responsibility for such changes lies with the vendor.
INQUIRIES:
Questions concerning this Request for Proposals (RFP) should be directed to the Parks and
Recreation Director Adam Wilson at 706-936-2671 or by email at
AWilson@summervillega.org. The deadline for the submission of all inquiries is
05/26/2026. Any changes to the specifications in the proposal package shall be in writing and an addendum will go out to all prospective respondents so each vendor can compete equitably.
mailto:AWilson@summervillega.org
AWARD OF CONTRACT:
Selection shall be made of one or more Respondents deemed fully qualified and best performing among those submitting bids. Negotiations shall be conducted with the
Respondents so selected. Price shall be considered, but may not be the sole determining factor. After negotiations have been conducted with each Respondent so selected, the City shall select the Respondent(s), which in its opinion, has made the best bid, and recommend that a contract(s) be awarded to the Respondent.
All contracts shall be in accordance with the laws of the State of Georgia. The City of
Summerville may cancel this RFP; reject proposals or any portion thereof at any time prior to an award, and is not required to furnish a statement of the reason why a particular bid was not deemed to be the most advantageous.
EVALUATION PROCEDURE:
All proposals will be evaluated and ranked by the City of Summerville. Negotiations and/or award of a contract may be initiated without further contact with the other Respondents.
BASIS FOR AWARD:
A committee of the City of Summerville Staff will review RFP submittals and will make its recommendation. The Committee may make such reasonable investigation, as it deems proper and necessary to determine the ability of the Respondent to perform the work/services.
SELECTION PROCESS:
The City shall select the most qualified Respondent. Each response shall be subject to the same review and evaluation process.
INSURANCE REQUIREMENTS:
The successful respondent shall agree to hold harmless, indemnify and defend the City of
Summerville, its agents, and employees from any claims for property damages or personal injury (including death resulting therefrom). Such claims are not limited to actual, consequential, incidental or punitive damages. The successful respondent shall agree to maintain sufficient comprehensive general liability insurance in the amount of
$1,000,000.00 per occurrence and $1,000,000.00 per person. Proof of such insurance shall be given to the City by an appropriate certificate-of-insurance issued by the successful respondent’s insurance agent. The successful respondent shall maintain vehicle liability insurance with minimum combined single limits of $1,000,000.00 per occurrence.
SCOPE OF SERVICES :
Pre-Bid Conference 05/21/2026-10:30 AM at Summerville Parks and Rec. 220 Hwy. 100
Summerville, Georgia 30747. If you need to make an appointment, contact the Parks &
Recreation Director at 706-936-2671 or by email at awilson@summervillega.org.
The City of Summerville, Ga is soliciting sealed proposals from qualified aquatic recreation and splash pad design-build firms for the construction of a new 3,464 square foot sports-themed splash pad facility featuring durable poly-coated FunForm play elements and a modern flow-through water management system configuration. The pad shall be round and consist of a reinforced concrete slab with a slip-resistent broom-finish and UV-stable polyurea safety coating to reduce falls. The selected contractor shall provide turnkey services including design, engineering, equipment procurement, site preparation, excavation, installation, and commissioning of an engaging, family-oriented aquatic play environment that promotes recreation, safety, ADA accessibility, and long-term operational efficiency. The project is intended to create a visually appealing destination attraction incorporating interactive sports-inspired spray features, themed components, and high-quality recreational amenities suitable for users of all ages. All spray features and products shall be manufactured by Water Odyssey™/ Fountain People, Inc., P.O. Box 807, San Marcos TX, 78667, 4600 Hwy. 123, San Marcos TX, 78666, telephone: 512-392-1155, facsimile: 512-392-1154, website: www.waterodyssey.com and must meet ASTM safety standards, be ADA compliant, and inspected by a Certified Playground Safety Inspector prior to shipment of product. All proposals should meet the minimum number of features listed in the RFP scope below. Additional features are allowed to be included in the RFP;
however, the minimum required must be met in order for the RFP to be considered.
C029 Crookett
1. Anchor Base: The (1) below grade anchor base shall be constructed of type 304 stainless steel to mate with a component’s shaft base plate. The anchor base shall each have a bonding/grounding connection and 2" FPT inlet. The anchor base shall be supplied with 3/8" threaded, 18/8 stainless steel anchor/leveling bolts with nuts, washers and a wooden pour template.
2. Construction Cover: The temporary cover shall be an adhesive polyethylene tape.
3. Shaft: The above grade frame shall be constructed of 3” type 304 stainless steel pipe with 3” machined type 304 flanged base plate.
4. Gasket: The leak preventing seal shall be an O-Ring of 70 durometer EPDM
5. Fasteners: All accessible fasteners shall be tamper-resistant 18/8 stainless steel.
mailto:awilson@summervillega.org http://www.waterodyssey.com/
6. Dimensions: Approximate dimensions shall be 4’7” H x 5’0” W.
7. Nozzles: Nozzles shall be a machined brass foam jet and eight Magic Flow stainless steel jet stream nozzles.
8. Interactive water effect: The spray pattern shall be eight inward-radiating streams with an aerated column of water emitting from the cone of the spray feature.
9. Hydraulic Requirements: The designed operational water supply shall be 18GPM
@ 20PSI.
10. Finish: When specified for solid, patterned or theme painted coloring the component shall be coated with Aqua Armor™; a UV stabilized, textured structural elastomeric polymer with a UV and chlorine resistant sealer coat.
11. ColorCast™ Accent: A color impregnated, rigid urethane polymer with resistance to chlorine and UV.
13. Age Group Design Standards: The spray feature shall be designed for all ages.
DISTRIBUTION MANIFOLD DM-04000-16-BR-PM
1. Distribution Header: The distribution manifold header shall be 4” type 304 stainless steel pipe with flanged connections on both ends.
2. Water Hammer Arrestor: The water hammer arrestor shall be 2” copper and brass construction with pre-set operating pressure of 10-35 PSI.
3. Drain Valve: The distribution manifold header shall have a ¾” hose bib style drain valve constructed of cast bronze.
4. Pressure Gauge: The distribution manifold header shall have a 0-60 PSI discharge side pressure gauge
5. Solenoid Valves: The distribution manifold header shall have 16 solenoid valves constructed die cast bronze with stainless steel hardware, DIN connector with 15’ cord and 24 VAC UL Recognized.
6. Balancing Valves: The distribution manifold header shall include 16 true union ball valves constructed of schedule 80 PVC for balancing and throttling the discharges.
7. Mounting Brackets: Shall be supplied with (3) Floor mount frames type 304 stainless steel with (3) stainless steel u-bolt.
Dynamic Sequencing Controller
A. DSC series aquatic play area controller provides independent custom re-programming and adjustment by the owner’s staff. The controller shall accept custom programming in the field from the aquatic playground operator. The controller shall have a SD card slot for play scenario back up.
B. DSC-8-16-A With Factory Mounted and Pre-Wired on Manifold Assembly Option
1. Housing: The 17 1/2” x 15 1/2” x 8” enclosure shall carry a NEMA 4X rating with a lockable hasp.
2. Input Power Supply: The input power supply shall be 120VAC/60 Hertz, 20 Amps capacity.
3. Power Cord: The power cord shall be 6 foot, 16-3 type SJT with grounded plug.
4. Output Power Supply: The output power supply shall be 24VAC/60 Hertz, 0.75
Amps capacity continuous per output.
5. Cord Seals: The cord seals shall be PVC compression seal fittings with neoprene gland for 16-2 solenoid valve cables.
6. Time Clock: The time clock shall be integral, electronic, 7 day, 24 hour.
7. Interface: The user interface shall be an integral keypad with 20 keys and a 4 x 20 backlit LCD display.
8. Programmable Events: The programmable events shall be timed duration, cycled, defined, random and/or cued sequencing. The events shall be field adjustable.
9. Programming: The programming shall be through the keyboard interface, set at the factory and shall be field adjustable.
10. Controller: This configuration shall have 8 12V DC digital inputs and 16 24V AC digital outputs.
11. Safety and Compliance: The Dynamic Sequencing Controller shall be CAN/CSA, ETL and Underwriters’ Laboratories Listed. The DSC controller shall comply with
Part 15 of the FCC Rules.
12. As manufactured by Water Odyssey™/ Fountain People, Inc., P.O. Box 807, San
Marcos TX, 78667, 4600 Hwy. 123, San Marcos TX, 78666, telephone: 512-392-
1155, facsimile: 512-392-1154, website: www.waterodyssey.com
F2056 Batter-Up! Fun Forms™ Aqua Sprayer
1. Anchoring Method: The Water Odyssey™ Fun Forms™ Aqua Sprayer secures to the cured slab with concrete anchors and fasteners as supplied by manufacturer.
The Aqua Sprayer water supply line shall terminate flush to the desired grade level and location, approximate center of the installed Aqua Sprayer, with a 1 1/2”FPT plumbing adapter supplied by the installer. The adapter shall be designed for compliance with bonding/grounding requirements of the jurisdiction having authority.
2. Connection Point: A 1 1/2”MPS machined PVC Fun Forms™ Stab Fitting connection with Viton® O-ring threads into installer supplied plumbing adapter and mates the Aqua Sprayer with a water tight seal.
3. Fasteners: All accessible fasteners shall be tamper-resistant stainless steel as supplied by the manufacturer. A special tool, supplied by the manufacturer, will be required for safe removal of spray feature, and to deter theft and vandalism.
4. Construction Material & Finish: The main body of the Fun Forms™ component shall be constructed of a hard foam core, and totally encapsulated with Aqua
Armor™; a UV stabilized, textured structural elastomeric polymer with a UV and chlorine resistant sealer coat. Finish texture shall be slip-resistant to reduce risk of injury.
5. Dimensions: Approximate dimensions shall be 2’-0” x 2’-0” x 10’-0” High.
6. Nozzles: The Aqua Sprayer nozzles shall be machined stainless steel and emit an array of outward arching streams from the handle of the bat. The nozzles shall be free of finger entrapment hazards.
7. Hydraulic Requirements: The designed operational water supply shall provide
30GPM @ 6PSI.
8 Age Group Design Standards: The Aqua Sprayer shall be designed for children of all ages.
F3056 Goooaal! Fun Forms™ Aqua Spout
1. Anchoring Method: The Water Odyssey™ Fun Forms™ Aqua Spout secures to
The Aqua Spout water supply line shall terminate flush to the desired grade level and location, approximate center of the installed Aqua Spout, with a 1”FPT plumbing adapter supplied by the installer. The adapter shall be designed for compliance with bonding/grounding requirements of the jurisdiction having authority.
2. Connection Point: A 1”NPS machined PVC Fun Forms™ Stab Fitting connection with Viton® O-ring threads into installer supplied plumbing adapter and mates the
Aqua Spout with a water tight seal.
3. Fasteners: All accessible fasteners shall be tamper-resistant stainless steel as supplied by the manufacturer. A special tool, supplied by the manufacturer, will be required for safe removal of spray feature, and to deter theft and vandalism.
4. Construction Material & Finish: The main body of the Fun Forms™ component shall be constructed of a hard foam core with rigid baseplate. The entire feature is totally encapsulated with Aqua Armor™; a UV stabilized, textured structural elastomeric polymer with a UV and chlorine resistant sealer coat. Finish texture shall be slip-resistant to reduce risk of injury.
5. Dimensions: Approximate dimensions shall be 20” x 20” x 10” High.
6. Nozzles: The Aqua Spout nozzle shall be machined PVC and produce a multiple stream arching water effect. Nozzle shall be free of finger entrapment hazards.
7. Hydraulic Requirements: The designed operational water supply shall provide
9GPM @ 2PSI.
8. Age Group Design Standards: The Aqua Spout shall be designed for children of all ages.
F3059-W82049 Volleyball Fun Forms™ Aqua Spout
The Aqua Spout water supply line shall terminate flush to the desired grade level and location, approximate center of the installed Aqua Spout, with a 1”FPT plumbing adapter supplied by the installer. The adapter shall be designed for compliance with bonding/grounding requirements of the jurisdiction having authority.
2. Connection Point: A 1”NPS machined PVC Fun Forms™ Stab Fitting connection with Viton® O-ring threads into installer supplied plumbing adapter and mates the
Aqua Spout with a water tight seal.
3. Fasteners: All accessible fasteners shall be tamper-resistant stainless steel as supplied by the manufacturer. A special tool, supplied by the manufacturer, will be required for safe removal of spray feature, and to deter theft and vandalism.
4. Construction Material & Finish: The main body of the Fun Forms™ component shall be constructed of a hard foam core with rigid baseplate. The entire feature is totally encapsulated with Aqua Armor™; a UV stabilized, textured structural elastomeric polymer with a UV and chlorine resistant sealer coat. Finish texture shall be slip-resistant to reduce risk of injury.
5. Dimensions: Approximate dimensions shall be 20” x 20” x 10” High.
6. Nozzles: The Aqua Spout nozzle shall be machined PVC and produce a multiple stream arching water effect. Nozzle shall be free of finger entrapment hazards.
7. Hydraulic Requirements: The designed operational water supply shall provide
5GPM @ 3PSI.
8. Age Group Design Standards: The Aqua Spout shall be designed for children of
F3060 Homerun Fun Forms™ Aqua Spout
The Aqua Spout water supply line shall terminate flush to the desired grade level and location, approximate center of the installed Aqua Spout, with a 1”FPT plumbing adapter supplied by the installer. The adapter shall be designed for compliance with bonding/grounding requirements of the jurisdiction having authority.
2. Connection Point: A 1”NPS machined PVC Fun Forms™ Stab Fitting connection with Viton® O-ring threads into installer supplied plumbing adapter and mates the
Aqua Spout with a water tight seal.
3. Fasteners: All accessible fasteners shall be tamper-resistant stainless steel as supplied by the manufacturer. A special tool, supplied by the manufacturer, will be required for safe removal of spray feature, and to deter theft and vandalism.
4. Construction Material & Finish: The main body of the Fun Forms™ component shall be constructed of a hard foam core with rigid baseplate. The entire feature is totally encapsulated with Aqua Armor™; a UV stabilized, textured structural elastomeric polymer with a UV and chlorine resistant sealer coat. Finish texture shall be slip-resistant to reduce risk of injury.
5. Dimensions: Approximate dimensions shall be 14” x 14” x 7” High.
6. Nozzles: The Aqua Spout nozzle shall be machined PVC and produce a multiple stream arching water effect. Nozzle shall be free of finger entrapment hazards.
7. Hydraulic Requirements: The designed operational water supply shall provide
5GPM @ 2PSI.
F3061 Blitz Fun Forms™ Aqua Spout
The Aqua Spout water supply line shall terminate flush to the desired grade level and location, approximate center of the installed Aqua Spout, with a 1”FPT plumbing adapter supplied by the installer. The adapter shall be designed for compliance with bonding/grounding requirements of the jurisdiction having authority.
2. Connection Point: A 1”NPS machined PVC Fun Forms™ Stab Fitting connection with Viton® O-ring threads into installer supplied plumbing adapter and mates the
Aqua Spout with a water tight seal.
3. Fasteners: All accessible fasteners shall be tamper-resistant stainless steel as supplied by the manufacturer. A special tool, supplied by the manufacturer, will be required for safe removal of spray feature, and to deter theft and vandalism.
4. Construction Material & Finish: The main body of the Fun Forms™ component shall be constructed of a hard foam core with rigid baseplate. The entire feature is totally encapsulated with Aqua Armor™; a UV stabilized, textured structural elastomeric polymer with a UV and chlorine resistant sealer coat. Finish texture shall be slip-resistant to reduce risk of injury.
5. Dimensions: Approximate dimensions shall be 20” x 12” x 7” High.
6. Nozzles: The Aqua Spout nozzle shall be machined PVC and produce a multiple vertical solid stream water effect. Nozzle shall be free of finger entrapment hazards.
7. Hydraulic Requirements: The designed operational water supply shall provide
6GPM @ 2PSI.
W009 Touch N’ Go™ Wired
1. Shaft: The above grade shaft, and base plate shall be constructed of 4” type 304 stainless steel with bonding/grounding connection.
2. Base Plate: Shall be type 304 stainless steel.
3. Anchors: Anchors shall be (4) stainless steel concrete anchors supplied by the manufacturer.
4. Fasteners: All accessible fasteners shall be tamper-resistant 18/8 stainless steel.
5. Activator Housing: Activator housing shall be machined PVC.
6. Activator Cord: Shall be supplied with 150’ of 18/3 type SJTOW submersible cable pre-wired to activator button, supplied.
7. Finish: When specified for solid, patterned or theme painted coloring the component shall be coated with Aqua Armor™; a UV stabilized, textured structural elastomeric polymer with a UV and chlorine resistant sealer coat.
W011C Jet Way™ Conserving
1. Housing: The below grade canister shall be constructed of 20 gauge deep-drawn type 304 stainless steel with bonding/grounding connection and 1" FPT inlet. It shall be supplied with 3/8" threaded anchor/leveling bolts with nuts, washers and a wooden pour template. The housing stabilizers and plate anchors shall be ½" x
5" machined brass with 30° hook bend. The temporary construction cover shall be a reusable flat 7" diameter HDPE (high density polyethylene) plate.
Bonding/grounding shall be compliant with codes of the jurisdiction having authority.
2. Top Plate: The operational cover shall be a 7" diameter, slightly domed, cast bronze plate with interchangeable nozzle assembly.
3. Finish: When specified for solid, patterned or theme painted coloring the component shall be coated with Aqua Armor™; a UV stabilized, textured structural elastomeric polymer with a UV and chlorine resistant sealer coat.
4. Fasteners: All accessible fasteners shall be tamper-resistant 18/8 stainless steel.
5. Gaskets: The leak preventing seal shall be an O-Ring of 70 Durometer EPDM.
6. Nozzle: The interchangeable nozzle for 7” diameter operational plates shall be constructed of precision machined brass.
7. Hydraulic Requirements: The designed operational water supply shall be 2-5GPM
@ 1-8PSI and produce a spray height of 2’-6”, reference drawings.
8. Interactive Water Effect: The spray pattern shall be a vertical stream spray.
9. Dimensions: The top plate diameter shall be 7”.
W062C Water Rail™ Conserving
1. Anchor Base: The below grade anchor base shall be constructed of type 304 have a bonding/grounding connection and 2" FPT inlet. It shall be supplied with
3/8" threaded, 18/8 stainless steel anchor/leveling bolts with nuts, washers and a wooden pour template. The temporary construction cover shall be an adhesive polyethylene tape. Bonding/grounding shall be compliant with codes of the jurisdiction having authority.
2. Construction Material: The above grade frame shall be constructed of 6” type 304 stainless steel pipe with type 304 flanged base plates. The closed end base opposite the water supply line side shall be supplied with stainless steel concrete anchors, 18/8 stainless steel tamper-resistant fasteners and a threaded drain plug.
3. Finish: When specified for solid, patterned or theme painted coloring the component shall be coated with Aqua Armor™; a UV stabilized, textured structural elastomeric polymer with a UV and chlorine resistant sealer coat.
4. Gaskets: The leak preventing seal shall be an O-Ring of 70 durometer EPDM.
5. Fasteners: All accessible fasteners shall be tamper-resistant 18/8 stainless steel.
6. Nozzle: The (9) Nozzles shall be machined brass precision jets.
7. Hydraulic Requirements: The designed operational water supply shall be 5-7GPM
@ 3-7PSI.
8. Interactive Water Effect: The spray pattern shall be an angled row of solid streams.
9. Dimensions: The approximate height shall be 4’04”.
W071 Water Flower™
1. Housing: The below grade canister shall be constructed of 20 gauge deep-drawn type 304 stainless steel with bonding/grounding connection and 1" FPT inlet. It shall be supplied with 3/8" threaded anchor/leveling bolts with nuts, washers and a wooden pour template. The housing stabilizers and plate anchors shall be ½" x
5" machined brass with 30° hook bend. The temporary construction cover shall be a reusable flat 7" diameter HDPE (high density polyethylene) plate.
Bonding/grounding shall be compliant with codes of the jurisdiction having authority.
2. Top Plate: The operational cover shall be a 7" diameter, slightly domed, cast bronze plate with interchangeable nozzle assembly.
3. Finish: When specified for solid, patterned or theme painted coloring the component shall be coated with Aqua Armor™; a UV stabilized, textured structural elastomeric polymer with a UV and chlorine resistant sealer coat.
4. Fasteners: All accessible fasteners shall be tamper-resistant 18/8 stainless steel.
5. Gaskets: The leak preventing seal shall be an O-Ring of 70 Durometer EPDM.
6. Nozzle: The interchangeable nozzle for 7” diameter operational plates shall be constructed of precision machined brass.
7. Hydraulic Requirements: The designed operational water supply shall be 10GPM
@ 1PSI and produce a spray height of 1’.
8. Interactive Water Effect: The spray pattern shall be a sheet effect in the shape of a morning glory flower.
9. Dimensions: The top plate diameter shall be 7”.
W200 Plain Drain™
1. Sump Housing: The below grade canister shall be formed polyethylene with a 4"
Slip outlet.
2. Top Grate: The operational grate shall be a 12" square, constructed of heavy-duty
FRP. The grate shall have a skid resistant surface urethane coating. The grate shall be
ADA compliant
3. Strainer Basket: The sump shall include a mesh molded polyurethane strainer basket.
4. Fasteners: All accessible fasteners shall be tamper-resistant 18/8 stainless steel.
5. Hydraulic Criteria: The designed operational gravity drain capacity shall be
6. 50 GPM with less than a ½” weir water depth.
7. Finish: When specified for painted coloring the component shall be coated with Aqua
Armor™; a UV stabilized, textured structural elastomeric polymer.
W344 Duet Jet™ Mini Series
1. Housing: The below grade housing shall be constructed of machine cast bronze with bonding/grounding connection and 2" FPT inlet. It shall be supplied with ¼”-20 threaded anchor/leveling bolts with nuts, and washers. Bonding/grounding shall be compliant with codes of the jurisdiction having authority.
2. Top Plate: The operational cover shall be a 3" diameter brass stock with ¼” thick top flange. Overall length shall be approximately 1”. The Top Plate nozzle insert shall have 2”NPS (straight) threads.
3. Finish: The finish shall be polished brass.
4. Fasteners: All accessible fasteners shall be tamper-resistant 18/8 stainless steel.
5. Nozzle: The nozzle shall be precision machined orifice.
6. Hydraulic Requirements: The designed operational water supply shall be 4-12GPM
@ 2-6PSI and produce a throw of 2’00”-10’00”, reference drawings.
7. Interactive Water Effect: The spray pattern shall be two arching streams.
8. Dimensions: The top plate shall be 3” diameter.
W362C-W82049 Big Sqwerts Softball™ Water Conserving
1. Anchor Base: The below grade anchor base shall be constructed of type 304 stainless steel to mate with a component’s shaft base plate. The anchor base shall have a bonding/grounding connection and 2" FPT inlet. It shall be supplied with 3/8" threaded, 18/8 stainless steel anchor/leveling bolts with nuts, washers and a wooden pour template. The temporary construction cover shall be an adhesive polyethylene tape Bonding/grounding shall be compliant with codes of the jurisdiction having authority.
2. Construction Material: The shaft shall be 3” type 304 stainless steel pipe with a machined type 304 base plate. The joints shall be a precision machined Delrin® flow control joint factory adjusted for 90° to 360° directional flow. The body shall be type 304 stainless steel manifold housed in a vandal resistant polymer body.
The main body of the theme-carved component shall be constructed of a hard foam core
3. Finish: When specified for solid, patterned or theme painted coloring the component shall be coated with Aqua Armor™; a UV stabilized, textured structural elastomeric polymer with a UV and chlorine resistant sealer coat
4. Gaskets: The leak preventing seal shall be an O-Ring of 70 durometer EPDM
5. Fasteners: All accessible fasteners shall be tamper-resistant 18/8 stainless steel.
6. Nozzle: The nozzle shall be a precision machined brass foam nozzle that produces a foam jet spray effect that is soft to touch and gentle on impact.
7. Hydraulic Requirements: The designed operational water supply shall be a 5-6
GMP GPM @ 5-8 PSI.
8. Interactive Water Effect: The effect shall be a directable spray of water.
9. Dimensions: The approximate dimension height shall be 4’ 4”.
W363C-W82049 Big Sqwerts Volleyball™ Water Conserving
1. Anchor Base: The below grade anchor base shall be constructed of type 304 have a bonding/grounding connection and 2" FPT inlet. It shall be supplied with
3/8" threaded, 18/8 stainless steel anchor/leveling bolts with nuts, washers and a wooden pour template. The temporary construction cover shall be an adhesive polyethylene tape Bonding/grounding shall be compliant with codes of the jurisdiction having authority.
2. Construction Material: The shaft shall be 3” type 304 stainless steel pipe with a machined type 304 base plate. The joints shall be a precision machined Delrin® flow control joint factory adjusted for 90° to 360° directional flow. The body shall be type 304 stainless steel manifold housed in a vandal resistant polymer body.
The main body of the theme-carved component shall be constructed of a hard foam core
3. Finish: When specified for solid, patterned or theme painted coloring the component shall be coated with Aqua Armor™; a UV stabilized, textured structural elastomeric polymer with a UV and chlorine resistant sealer coat
4. Gaskets: The leak preventing seal shall be an O-Ring of 70 durometer EPDM
5. Fasteners: All accessible fasteners shall be tamper-resistant 18/8 stainless steel.
6. Nozzle: The nozzle shall be a precision machined brass foam nozzle that produces a foam jet spray effect that is soft to touch and gentle on impact.
7. Hydraulic Requirements: The designed operational water supply shall be a 5-6
GMP GPM @ 5-8 PSI.
8. Interactive Water Effect: The effect shall be a directable spray of water.
9. Dimensions: The approximate dimension height shall be 4’ 4”.
W394-W80249 Softball, Soccer, Volleyball Buckets ™ bonding/grounding connection and 2" FPT inlet. It shall be supplied with 3/8" threaded, 18/8 stainless steel anchor/leveling bolts with nuts, washers and a wooden pour template.
2. Construction Material: The shaft shall be 4” type 304 stainless steel pipe with a machined type 304ss base plate. The body shall be type 304 stainless steel manifold housed in a vandal resistant polymer body. The main body of the theme-carved component shall be constructed of a hard foam core with Aqua Armor.
3. Finish: When specified for solid, patterned or theme painted coloring the component shall be coated with Aqua Armor™; a UV stabilized, textured structural elastomeric polymer with a UV and chlorine resistant sealer coat
4. Gaskets: The leak preventing seal shall be an O-Ring of 70 durometer EPDM
5. Fasteners: All accessible fasteners shall be tamper-resistant 18/8 stainless steel.
6. Nozzle: The nozzles/orifice shall be open pipe. Nozzle shall be free of finger entrapment hazards.
7. Hydraulic Requirements: The designed operational water supply shall be a maximum 5-10GPM @ 6PSI.
8. Interactive Water Effect: The effect shall be a dumping burst of water.
9. Dimensions: The approximate dimension height shall be 12’ 4”.
W403 Baseball Glove™ bonding/grounding connection and 2" FPT inlet. It shall be supplied with 3/8" threaded, 18/8 stainless steel anchor/leveling bolts with nuts, washers and a wooden pour template.
2. Closed End Base: 2 Stainless steel concrete anchors and a threaded drain plug.
3. Construction Material: The shaft shall be 4” type 304 stainless steel pipe with a machined type 304ss base plate. The body shall be type 304 stainless steel manifold housed in a vandal resistant polymer body. The main body of the theme-carved component shall be constructed of a hard foam core with Aqua Armor.
4. Finish: When specified for solid, patterned or theme painted coloring the component shall be coated with Aqua Armor™; a UV stabilized, textured structural elastomeric polymer with a UV and chlorine resistant sealer coat
5. Gaskets: The leak preventing seal shall be an O-Ring of 70 durometer EPDM
6. Fasteners: All accessible fasteners shall be tamper-resistant 18/8 stainless steel.
7. Nozzle: The nozzle shall be 7 stainless steel precision jets.
8. Hydraulic Requirements: The designed operational water supply shall be a maximum 9GPM @ 5PSI.
9. Interactive Water Effect: The effect shall be a precision spray of water.
10. Dimensions: The approximate dimension height shall be 4’ 8”.
W416 Welcome Sign ™ bonding/grounding connection and 2" FPT inlet. It shall be supplied with 3/8" threaded, 18/8 stainless steel anchor/leveling bolts with nuts, washers and a wooden pour template.
2. Construction Material: The shaft shall be 6” type 304 stainless steel pipe with a machined type 304ss base plate. The body shall be type 304 stainless steel manifold housed in a vandal resistant polymer body. The main body of the theme-carved component shall be constructed of a hard foam core with Aqua Armor.
3. Finish: When specified for solid, patterned or theme painted coloring the component shall be coated with Aqua Armor™; a UV stabilized, textured structural elastomeric polymer with a UV and chlorine resistant sealer coat
4. Gaskets: The leak preventing seal shall be an O-Ring of 70 durometer EPDM
5. Fasteners: All accessible fasteners shall be tamper-resistant 18/8 stainless steel.
6. Nozzle: The nozzles shall be stainless steel precision jets. Nozzle shall be free of finger entrapment hazards.
7. Hydraulic Requirements: The designed operational water supply shall be a maximum 22GPM @ 10PSI.
8. Interactive Water Effect: The effect shall be a row of solid stream jets.
9. Dimensions: The approximate dimension height shall be 8’ x 1’2” x 14’
10. Graphics: The sign graphics shall be the Summerville Recreation Logo
WVB-60120-16 Above Grade Utility Cabinet
1. Enclosure Construction: 1/8th inch aluminum to NEMA 3R standards with 2 inch mounting flange on bottom.
2. Doors: Overlapping doors with full height stainless steel hinges, neoprene gasket, 3 position door stop assemblies and removable center post. Right door as 3 point latching, ¾ inch stainless steel handle with padlock hasp, corbin #2 lock, screened louvers with filter and one door switch bracket.
3. As manufactured by Water Odyssey™/ Fountain People, Inc., P.O. Box 807, San
Marcos TX, 78667, 4600 Hwy. 123, San Marcos TX, 78666, telephone: 512-392-
1155, facsimile: 512-392-1154, website: www.waterodyssey.com
CERTIFICATE OF NON-DISCRIMINATION
In connection with the performance of work under this contract, the vendor agrees as follows:
The vendor agrees not to discriminate against any employee or applicant for employment because of race, creed, color, sex, national origin, ancestry, or disability. The vendor shall take affirmative action to insure that employees are treated without regard to their race, creed, color, sex, national origin, ancestry, or disability. Such action shall include, but not be limited to the following: employment, upgrading, demotion, transfer, recruiting or recruitment, advertising, lay-off or termination, rates of pay or other compensation and selection for training, including apprenticeship.
In the event of the vendor’s non-compliance with this non-discrimination clause, the contract may be cancelled or terminated by the City of Summerville. The vendors may be declared, by the City of
Summerville, ineligible for further contracts with the City of Summerville until satisfactory proof of intent to comply shall be made by the vendor.
The vendor agrees to include this non-discrimination clause in any sub-contracts connected with the performance of this agreement.
Vendor
Signature
Title
City of Summerville, Georgia
E-Verify Compliance Affidavit
STATE OF GEORGIA
COUNTY OF _______________
By executing this affidavit, the undersigned contractor verifies its compliance with O.C.G.A. §13-10-91, stating affirmatively that the individual, firm or corporation which is engaged in the physical performance of services on behalf of the City of Summerville, Georgia has registered with, is authorized to use and uses the federal work authorization program commonly known as E-Verify, or any subsequent replacement program, in accordance with the applicable provisions and deadlines established in O.C.G.A. §13-10-91. Furthermore, the undersigned contractor will continue to use the federal work authorization program throughout the contract period and the undersigned contractor will contract for the physical performance of services in satisfaction of such contract only with subcontractors who present an affidavit to the contractor with the information required by O.C.G.A. §13-10-91(b).
Contractor hereby attests that its federal work authorization user identification number and date of authorization are as follows:
Federal Work Authorization User ID Number Signature (if less than 10 employees)
Date of Authorization Name of Contractor/Company
Name of Project Name of Public Employer
I hereby declare under penalty of perjury that the foregoing is true and correct.
Executed on ________ day of __________________, 20____.
Signature of Authorized Officer or Agent Printed Name of Officer or Agent
Subscribed and sworn before me
This ______ day of _________________, 20______.
My Commission Expires: ______________________
CITY OF SUMMERVILLE, GEORGIA
SAVE COMPLIANCE AFFIDAVIT
O.C.G.A. §50-36-1(f)(1)(B)
By executing this affidavit under oath, as an applicant for a Contract, as referenced in O.C.G.A. §50-36- 1, from the City of Summerville, Georgia, the undersigned applicant verifies one of the following with respect to my application for public benefit:
1) ___________ I am a United States citizen.
2) ___________ I am a legal permanent resident of the United States.
3) ___________ I am a qualified alien or non-immigrant under the Federal Immigration and Nationality Act with an alien number issued by the Department of Homeland Security or other federal immigration agency.
My alien number issued by the Department of Homeland Security or other federal immigration agency is: _____________________
The undersigned applicant also hereby verifies that he or she is 18 years of age or older and has provided at least one secure and verifiable document, as required by O.C.G.A. §50-36-1 (f)(1)(A), with this affidavit.
The secure and verifiable document provided with this affidavit can best be classified as:
In making the above representation under oath, I understand that any person who knowingly and willfully makes a false, fictitious, or fraudulent statement or representation in an affidavit shall be guilty of a violation of O.C.G.A. §16-10-20, and face criminal penalties as allowed by such criminal statutes.
Executed on ________ day of __________________, 20____.
Signature of Authorized Officer or Agent Printed Name of Officer or Agent
Subscribed and sworn before me This ______ day of _________________, 20______.
My Commission Expires: ______________________
File details come from the government source that posted it. Updated .