This document is a city response to questions received regarding Request for Proposals (RFP) 2024-04 for Brownfield Cleanup Grant - Professional Services. The City of Perry, Georgia issued this RFP to procure professional services for a brownfield cleanup project. The response provides answers to two specific questions raised about the site's water infrastructure and the availability of additional Phase II environmental assessment reports. The city confirms that the water tower on the target parcel is connected to the city's water system, and includes the requested January and August 2021 Phase II reports as an addendum to the original October 2019 assessment.

The Phase II reports detail the results of groundwater sampling conducted in December 2020, which found elevated levels of tetrachloroethene (PCE) in monitoring wells across the site. The city recommends that the current property owner submit a release notification to the state environmental agency based on these findings. The reports also provide an updated conceptual site model and groundwater flow assessment for the project area.

View the file

Other files

File Type Posted
RFP 2024_04 Perry _ Brownfield Consultant.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

1211 Washington Street | P.O. Box 2030 | Perry, Georgia 31069-6030 www.perry-ga.gov

DATE: July 12, 2024

PROJECT: Brownfield Cleanup Grant – Professional Services

RFP 2024-04

As of July 12, 2024, the City has received the following questions pertaining to RFP 2024- 04 that have not been addressed via addendum:

1. Is the water tower on Parcel 0p0020012000 connected to a water will, or is there a water well situated anywhere on this parcel?

ANSWER:

o The tower is connected to the City’s water infrastructure which is groundwater supplied.

The wells, however, are not in the vicinity of this parcel.

2. The Phase II that was provided in the first Addendum to this RFP is dated October 22, 2019. The Draft ABCA references some other supplemental Phase II work which was completed in January and August of 2021. Is there a way to also get a copy of these assessment reports from 2021?

ANSWER:

o Included with this document are the additional Phase II reports.

January 11, 2021

Mr. Robert Smith, Assistant City Manager City of Perry 1121 Washington Street Perry, Georgia 31069

RE: Phase II Environmental Site Assessment Addendum #1

Stanley Assemblage Site 1101, 1107, and 1109 Macon Street 1102 and 1104 Meeting Street

Perry, Houston County, Georgia 31069

Dear Mr. Smith:

Cardno, on behalf of the City of Perry (City), respectfully submits this letter as an Addendum to the Phase II Environmental Site Assessment (ESA) that was submitted on October 22, 2019, for the above referenced assemblage, herein referred to as the “Subject Property” or “Site.” This addendum addresses the analysis of additional groundwater samples collected from groundwater monitoring wells installed on the Subject Property during the 2019 Phase II ESA. The City intends to purchase the property from the current owner. At the time of the 2019 Phase II ESA report, the City intended to purchase eight (8) parcels referenced in the Phase II ESA; however, the acquisition has been reduced to the five parcels listed above and depicted in the attached figures.

The actions discussed herein were completed in order to update the conceptual site model for the property by providing current groundwater monitoring data.

This work was completed under guidelines set forth in the Site-Specific Quality Assurance Project Plan Addendum dated December 23, 2020, and approved by Ms. Olga Perry of USEPA on December 28, 2020. Additionally, this assessment was performed under and funded by the City of Perry Environmental Protection Agency (EPA) FY2018 Community-wide Brownfield Assessment Grant.

Groundwater Sampling Activities

Cardno mobilized to the Subject Property on December 29, 2020, to sample groundwater monitoring wells MW-1 through MW-3. Prior to sampling, the wells were gauged for depth to groundwater then purged with a Mega Monsoon low flow pump until a minimum of three well volumes were purged and groundwater quality parameters were stabilized. Groundwater quality parameters measured include pH, temperature, conductivity, and dissolved oxygen, and turbidity were measured using an In-Situ Horiba water-quality meter. Equipment calibration documentation is included in Appendix A.

A summary of each installed groundwater well is as follows:

Monitoring Well MW-1 was installed on 1109 Macon Street adjacent to the former dry cleaner, listed on the Georgia Environmental Protection Division (EPD) Hazardous Site Inventory (HSI) as EPD ID# 10940. The monitoring well was purged of over three well volumes, and after groundwater parameters were stabilized, a groundwater sample was collected on December 29, 2020, and analyzed for VOCs via USEPA Method 8260B.

6611 Bay Circle Suite 220 Norcross, Georgia 30071

USA

Phone 678-421-0080 www.cardno.com

Mr. Robert Smith Stanley Assemblage January 11, 2021 Phase II Environmental Site Assessment – Addendum#1

Monitoring Well MW-2 was installed on 1101 Macon Street, south of the former dry cleaner. The monitoring well was purged of over three well volumes, and after groundwater parameters were stabilized, a groundwater sample was collected on December 29, 2020, and analyzed for VOCs via USEPA Method 8260B.

Monitoring Well MW-3 was installed on 1102 Meeting Street, southwest of the former dry cleaner.

The monitoring well was purged of over three well volumes, and after groundwater parameters were stabilized, a groundwater sample was collected on December 29, 2020, and analyzed for VOCs via USEPA Method 8260B.

Three groundwater samples, one duplicate groundwater sample, and one trip blank were submitted to Analytical Environmental Services (AES) laboratories in Norcross, Georgia under chain-of-custody protocol. A groundwater analytical summary (detections only) is provided in Table 1.

A summary of groundwater sampling logs can be found in Appendix B.

Quality Assurance and Quality Control Methods

Samples were labeled with a distinct sample identification number, the sampler’s initials, and the date of the collection. Each sample container was properly sealed, labeled, and placed on ice in a cooler for deliver to AES within the sample hold times. A properly completed chain-of-custody form was initiated in the field and accompanied the samples when submitted to the laboratory for analyses. One QA/QC sample was collected and analyzed for the following: MW-2 (Duplicate):

VOCs.

Copies of the chain-of-custody forms are shown in the laboratory analytical reports included as Appendix C.

Groundwater Analytical Results

A comparison of the laboratory analytical results of the collected groundwater samples to the Georgia EPD MTC or samples that exhibited detections above the laboratory method detection limits is presented in Table 1 with locations depicted on Figure 1. In summary:

Tetrachloroethene (PCE) was identified at concentrations above the EPD Media Target Concentration (MTC) of 0.005 mg/L in groundwater samples collected from all three monitoring wells (MW-1 through MW-3), with a maximum concentration of 0.65 mg/L detected in MW-3.

PCE concentration increased in all three monitoring wells between the May 2019 and December 2020 sampling events as follows: from 0.22 to 0.33 mg/L in MW-1, from 0.046 to 0.080 mg/L in MW-2, and from 0.26 to 0.65 mg/L in MW-3.

Remaining VOC constituents were not detected at levels above laboratory method detection limits.

Groundwater analytical results from both sampling events are summarized in Table 1. Analytical results from the December 2020 sampling event are presented in their entirety in the laboratory analytical report included in Appendix C.

Laboratory Analyses Quality Control (QC) Observations and Interpretations

No significant QA/QC issues were encountered by the laboratory. All samples were received in good condition, with all spikes and surrogates were recovered within established limits; and all method-specified holding times were met. A duplicate groundwater sample was collected from MW-2 and analyzed for VOCs. Analytical results derived from this sample were similar to analytical results from MW-2 (MW-2 duplicate detected PCE at 0.077 mg/L), with no abnormalities detected.

The Laboratory Analytical Report is included as Appendix C.

Groundwater Elevation Data Collection & Shallow Groundwater Flow Direction

To assist in determining the direction of groundwater flow within the boundaries of the Subject Property, elevation data was collected from the monitoring wells. Elevations were recorded relative to an arbitrary datum to assist in the evaluation of shallow groundwater flow direction.

Depth-to-groundwater measurements were taken from top of casing.

A comparison of shallow water table elevations measured on December 29, 2020, to an arbitrary benchmark indicated a shallow groundwater gradient flowing predominantly towards the southwest towards Big Indian Creek located 2,700 feet west of the Site.

An inferred groundwater elevation summary is present in Table 2 and shallow groundwater gradient is depicted on Figures 2a and 2b.

Investigative-Derived Waste

Investigative-derived waste (IDW) generated during this sampling event included recovered groundwater from purging monitoring wells, which was contained in one 55-gallon drum. The drum was staged on the Subject Property, and labeled as non-hazardous waste with waste generator information provided. The purge water will be characterized and properly disposed via appropriate legal means a permitted disposal facility.

Conclusion and Recommendation

Based on the results of this Phase II ESA Addendum, Cardno makes the following recommendation:

PCE concentrations and groundwater gradient is consistent between the May 2019 and December 2020 sampling events.

The PCE concentrations reported in groundwater samples collected from monitoring wells MW-1, MW-2, and MW-3 were all above the Georgia EPD’s MTC for PCE. Based on these results, Cardno recommends that this letter report be provided to the current owner, as they are required to submit a release notification to the Georgia Environmental Protection Division’s (EPD) Hazardous Sites Response and Remediation Program, within 30 days of discovery.

Please contact the undersigned if further information or clarification is necessary.

Sincerely, Sam Urban Cardno Project Manager Direct Line: 678.496.7966 Sam.Urban@cardno.com

Douglas Strait, PE For Cardno Project Manager Direct Line: 770.316.2466 Douglas.Strait@cardno.com

Appendices Figures Tables Appendix A Equipment Calibration Appendix B Groundwater Sampling Logs Appendix C Laboratory Analytical Report mailto:Sam.Urban@cardno.com mailto:Douglas.Strait@cardno.com

Figures

Tables

VOCs 8 RCRA METALS

(mg/L) (mg/L)

05.09.2019 0.22 0.0326

12.29.2020 0.33 N/A

05.09.2019 0.046 0.0419

12.29.2020 0.08 N/A

05.09.2019 0.26 0.0289

12.29.2020 0.65 N/A

0.005 2.0

Notes:

MTCs = Media Target Concentrations

VOC (Volative Organic Compound)

RCRA (Resource Conservation and Recovery Act) mg/L = milligrams per liter

MTCs

Monitoring Well No.

Date Collected

Tetrachloroethene Barium

Sample

MW-1

MW-2

MW-3

Concentrations in bold and highlighted (yellow) exceed GA MTCs

FACILITY NAME: STANLEY ASSEMBLAGE

PERRY, GA

Laboratory Analyses

TABLE 1: GROUNDWATER ANALYTICAL

SUMMARY (DETECTIONS ONLY)

W ell N u m b er

D ate

C asin g E levatio n

D ep th o f W ell

W ell B o tto m

E levatio n D ep th to W ater P o ten tio m etric S u rface E levatio n

05.09.2019 100.71

63.9 36.81

53.33 47.38

12.29.2020 100.71

63.9 36.81

51.83 48.88

05.09.2019 100.90

60.62 40.28

54.56 46.34

12.29.2020 100.90

60.62 40.28

52.95 47.95

05.09.2019 99.55

60.59 38.96

53.64 45.91

M W

-3 12.29.2020

99.55 60.59

38.96 52.26

47.29

F A

C

IL

IT

Y

N A

M E

: S T

A N

L E

Y A

S S

E M

B L

A G

E

T A

B L

E 2: G

R O

U N

D W

A T

E R

E L

E V

A T

IO

N

S U

M M

A R

Y

P E

R R

Y , G

A

M W

-1

M W

-2

Appendix A

Equipment Calibration

Appendix B

Groundwater Sampling Logs

Appendix C

Laboratory Analytical Report

January 04, 2021

Dear Order No:

RE:

Analytical Environmental Services, Inc. received samples on for the analyses presented in following report.

“No problems were encountered during the analyses except as noted in the Case Narrative or by qualifiers in the report or QC Summary. Additionally, all results for the associated Quality Control samples were within

EPA and/or AES established limits.

AES’s accreditations are as follows:

-NELAP/State of Florida Laboratory ID E87582 for analysis of Non-Potable Water, Solid & Chemical

Materials, Air & Emissions Volatile Organics, and Drinking Water Microbiology & Metals, effective

07/01/20-06/30/21.

State of Georgia, Department of Natural Resources ID #800 for analysis of Drinking Water Metals, effective through 06/30/21 and Total Coliforms/ E. coli, effective 04/20/20-04/24/23.

-AIHA-LAP, LLC Laboratory ID: 100671 for Industrial Hygiene samples (Metals and PCM Asbestos), Environmental Lead (Paint, Soil, Dust Wipes, Air), and Environmental Microbiology (Fungal) Direct

Examination, effective until 11/01/21.

These results relate only to the items tested as received. This report may only be reproduced in full.

If you have any questions regarding these test results, please feel free to call.

Sincerely, Project Manager

2012T82

Sam Urban Cardno

6611 Bay Circle Peachtree Corners GA 30071

Stanley Assemblage

Ioana Pacurar

12/30/2020 9:50:00 AM

Sam Urban:

P a g e o f 1

2012T82-001

4-Jan-21Date:Analytical Environmental Services, Inc

Analyses Date Analyzed Dilution

Factor BatchIDUnitsQual

Reporting

Limit Result

Client:

Groundwater

12/29/2020 3:37:00 PM

MW-1

Matrix:

Collection Date:

Client Sample ID:

Stanley Assemblage

Cardno

Lab ID:

Project Name:

Analyst

(SW5030B)TCL VOLATILE ORGANICS SW8260D

1,1,1-Trichloroethane BRL 5.0 ug/L 308188 1 12/30/2020 12:49 OM

1,1,2,2-Tetrachloroethane BRL 5.0 ug/L 308188 1 12/30/2020 12:49 OM

1,1,2-Trichloroethane BRL 5.0 ug/L 308188 1 12/30/2020 12:49 OM

1,1-Dichloroethane BRL 5.0 ug/L 308188 1 12/30/2020 12:49 OM

1,1-Dichloroethene BRL 5.0 ug/L 308188 1 12/30/2020 12:49 OM

1,2,4-Trichlorobenzene BRL 5.0 ug/L 308188 1 12/30/2020 12:49 OM

1,2-Dibromo-3-chloropropane BRL 5.0 ug/L 308188 1 12/30/2020 12:49 OM

1,2-Dibromoethane BRL 5.0 ug/L 308188 1 12/30/2020 12:49 OM

1,2-Dichlorobenzene BRL 5.0 ug/L 308188 1 12/30/2020 12:49 OM

1,2-Dichloroethane BRL 5.0 ug/L 308188 1 12/30/2020 12:49 OM

1,2-Dichloropropane BRL 5.0 ug/L 308188 1 12/30/2020 12:49 OM

1,3-Dichlorobenzene BRL 5.0 ug/L 308188 1 12/30/2020 12:49 OM

1,4-Dichlorobenzene BRL 5.0 ug/L 308188 1 12/30/2020 12:49 OM

2-Butanone BRL 50 ug/L 308188 1 12/30/2020 12:49 OM

2-Hexanone BRL 10 ug/L 308188 1 12/30/2020 12:49 OM

4-Methyl-2-pentanone BRL 10 ug/L 308188 1 12/30/2020 12:49 OM

Acetone BRL 50 ug/L 308188 1 12/30/2020 12:49 OM

Benzene BRL 5.0 ug/L 308188 1 12/30/2020 12:49 OM

Bromodichloromethane BRL 5.0 ug/L 308188 1 12/30/2020 12:49 OM

Bromoform BRL 5.0 ug/L 308188 1 12/30/2020 12:49 OM

Bromomethane BRL 5.0 ug/L 308188 1 12/30/2020 12:49 OM

Carbon disulfide BRL 5.0 ug/L 308188 1 12/30/2020 12:49 OM

Carbon tetrachloride BRL 5.0 ug/L 308188 1 12/30/2020 12:49 OM

Chlorobenzene BRL 5.0 ug/L 308188 1 12/30/2020 12:49 OM

Chloroethane BRL 10 ug/L 308188 1 12/30/2020 12:49 OM

Chloroform BRL 5.0 ug/L 308188 1 12/30/2020 12:49 OM

Chloromethane BRL 10 ug/L 308188 1 12/30/2020 12:49 OM cis-1,2-Dichloroethene BRL 5.0 ug/L 308188 1 12/30/2020 12:49 OM cis-1,3-Dichloropropene BRL 5.0 ug/L 308188 1 12/30/2020 12:49 OM

Cyclohexane BRL 5.0 ug/L 308188 1 12/30/2020 12:49 OM

Dibromochloromethane BRL 5.0 ug/L 308188 1 12/30/2020 12:49 OM

Dichlorodifluoromethane BRL 10 ug/L 308188 1 12/30/2020 12:49 OM

Ethylbenzene BRL 5.0 ug/L 308188 1 12/30/2020 12:49 OM

Freon-113 BRL 10 ug/L 308188 1 12/30/2020 12:49 OM

Isopropylbenzene BRL 5.0 ug/L 308188 1 12/30/2020 12:49 OM m,p-Xylene BRL 5.0 ug/L 308188 1 12/30/2020 12:49 OM

Methyl acetate BRL 5.0 ug/L 308188 1 12/30/2020 12:49 OM

Methyl tert-butyl ether BRL 5.0 ug/L 308188 1 12/30/2020 12:49 OM

Methylcyclohexane BRL 5.0 ug/L 308188 1 12/30/2020 12:49 OM

Methylene chloride BRL 5.0 ug/L 308188 1 12/30/2020 12:49 OM o-Xylene BRL 5.0 ug/L 308188 1 12/30/2020 12:49 OM

Styrene BRL 5.0 ug/L 308188 1 12/30/2020 12:49 OM

Tetrachloroethene 330 50 ug/L 308188 10 12/31/2020 13:06 OM

Toluene BRL 5.0 ug/L 308188 1 12/30/2020 12:49 OM trans-1,2-Dichloroethene BRL 5.0 ug/L 308188 1 12/30/2020 12:49 OM

Qualifiers: * Value exceeds maximum contaminant level

BRL Below reporting limit

H Holding times for preparation or analysis exceeded

N Analyte not NELAC certified

B Analyte detected in the associated method blank

E Estimated (value above quantitation range)

S Spike Recovery outside limits due to matrix

Narr See case narrative

F Analyzed in the lab which is a deviation from the method

< Less than Result value

> Greater than Result value J Estimated value detected below Reporting Limit

2012T82-001

Analyses Date Analyzed Dilution

Factor BatchIDUnitsQual

Reporting

Limit Result

Client:

Groundwater

12/29/2020 3:37:00 PM

MW-1

Matrix:

Collection Date:

Client Sample ID:

Stanley Assemblage

Cardno

Lab ID:

Project Name:

Analyst

(SW5030B)TCL VOLATILE ORGANICS SW8260D

trans-1,3-Dichloropropene BRL 5.0 ug/L 308188 1 12/30/2020 12:49 OM

Trichloroethene BRL 5.0 ug/L 308188 1 12/30/2020 12:49 OM

Trichlorofluoromethane BRL 5.0 ug/L 308188 1 12/30/2020 12:49 OM

Vinyl chloride BRL 2.0 ug/L 308188 1 12/30/2020 12:49 OM

Surr: 4-Bromofluorobenzene 95.5 74.9-127 %REC 308188 1 12/30/2020 12:49 OM

Surr: 4-Bromofluorobenzene 97.6 74.9-127 %REC 308188 10 12/31/2020 13:06 OM

Surr: Dibromofluoromethane 103 78.9-121 %REC 308188 1 12/30/2020 12:49 OM

Surr: Dibromofluoromethane 103 78.9-121 %REC 308188 10 12/31/2020 13:06 OM

Surr: Toluene-d8 98.6 81.5-120 %REC 308188 10 12/31/2020 13:06 OM

Surr: Toluene-d8 100 81.5-120 %REC 308188 1 12/30/2020 12:49 OM

Qualifiers: * Value exceeds maximum contaminant level

BRL Below reporting limit

H Holding times for preparation or analysis exceeded

N Analyte not NELAC certified

B Analyte detected in the associated method blank

E Estimated (value above quantitation range)

S Spike Recovery outside limits due to matrix

Narr See case narrative

F Analyzed in the lab which is a deviation from the method

< Less than Result value

2012T82-002

Analyses Date Analyzed Dilution

Factor BatchIDUnitsQual

Reporting

Limit Result

Client:

Groundwater

12/29/2020 11:56:00 AM

MW-2

Matrix:

Collection Date:

Client Sample ID:

Stanley Assemblage

Cardno

Lab ID:

Project Name:

Analyst

(SW5030B)TCL VOLATILE ORGANICS SW8260D

1,1,1-Trichloroethane BRL 5.0 ug/L 308188 1 12/30/2020 13:13 OM

1,1,2,2-Tetrachloroethane BRL 5.0 ug/L 308188 1 12/30/2020 13:13 OM

1,1,2-Trichloroethane BRL 5.0 ug/L 308188 1 12/30/2020 13:13 OM

1,1-Dichloroethane BRL 5.0 ug/L 308188 1 12/30/2020 13:13 OM

1,1-Dichloroethene BRL 5.0 ug/L 308188 1 12/30/2020 13:13 OM

1,2,4-Trichlorobenzene BRL 5.0 ug/L 308188 1 12/30/2020 13:13 OM

1,2-Dibromo-3-chloropropane BRL 5.0 ug/L 308188 1 12/30/2020 13:13 OM

1,2-Dibromoethane BRL 5.0 ug/L 308188 1 12/30/2020 13:13 OM

1,2-Dichlorobenzene BRL 5.0 ug/L 308188 1 12/30/2020 13:13 OM

1,2-Dichloroethane BRL 5.0 ug/L 308188 1 12/30/2020 13:13 OM

1,2-Dichloropropane BRL 5.0 ug/L 308188 1 12/30/2020 13:13 OM

1,3-Dichlorobenzene BRL 5.0 ug/L 308188 1 12/30/2020 13:13 OM

1,4-Dichlorobenzene BRL 5.0 ug/L 308188 1 12/30/2020 13:13 OM

2-Butanone BRL 50 ug/L 308188 1 12/30/2020 13:13 OM

2-Hexanone BRL 10 ug/L 308188 1 12/30/2020 13:13 OM

4-Methyl-2-pentanone BRL 10 ug/L 308188 1 12/30/2020 13:13 OM

Acetone BRL 50 ug/L 308188 1 12/30/2020 13:13 OM

Benzene BRL 5.0 ug/L 308188 1 12/30/2020 13:13 OM

Bromodichloromethane BRL 5.0 ug/L 308188 1 12/30/2020 13:13 OM

Bromoform BRL 5.0 ug/L 308188 1 12/30/2020 13:13 OM

Bromomethane BRL 5.0 ug/L 308188 1 12/30/2020 13:13 OM

Carbon disulfide BRL 5.0 ug/L 308188 1 12/30/2020 13:13 OM

Carbon tetrachloride BRL 5.0 ug/L 308188 1 12/30/2020 13:13 OM

Chlorobenzene BRL 5.0 ug/L 308188 1 12/30/2020 13:13 OM

Chloroethane BRL 10 ug/L 308188 1 12/30/2020 13:13 OM

Chloroform BRL 5.0 ug/L 308188 1 12/30/2020 13:13 OM

Chloromethane BRL 10 ug/L 308188 1 12/30/2020 13:13 OM cis-1,2-Dichloroethene BRL 5.0 ug/L 308188 1 12/30/2020 13:13 OM cis-1,3-Dichloropropene BRL 5.0 ug/L 308188 1 12/30/2020 13:13 OM

Cyclohexane BRL 5.0 ug/L 308188 1 12/30/2020 13:13 OM

Dibromochloromethane BRL 5.0 ug/L 308188 1 12/30/2020 13:13 OM

Dichlorodifluoromethane BRL 10 ug/L 308188 1 12/30/2020 13:13 OM

Ethylbenzene BRL 5.0 ug/L 308188 1 12/30/2020 13:13 OM

Freon-113 BRL 10 ug/L 308188 1 12/30/2020 13:13 OM

Isopropylbenzene BRL 5.0 ug/L 308188 1 12/30/2020 13:13 OM m,p-Xylene BRL 5.0 ug/L 308188 1 12/30/2020 13:13 OM

Methyl acetate BRL 5.0 ug/L 308188 1 12/30/2020 13:13 OM

Methyl tert-butyl ether BRL 5.0 ug/L 308188 1 12/30/2020 13:13 OM

Methylcyclohexane BRL 5.0 ug/L 308188 1 12/30/2020 13:13 OM

Methylene chloride BRL 5.0 ug/L 308188 1 12/30/2020 13:13 OM o-Xylene BRL 5.0 ug/L 308188 1 12/30/2020 13:13 OM

Styrene BRL 5.0 ug/L 308188 1 12/30/2020 13:13 OM

Tetrachloroethene 80 5.0 ug/L 308188 1 12/30/2020 13:13 OM

Toluene BRL 5.0 ug/L 308188 1 12/30/2020 13:13 OM trans-1,2-Dichloroethene BRL 5.0 ug/L 308188 1 12/30/2020 13:13 OM

Qualifiers: * Value exceeds maximum contaminant level

BRL Below reporting limit

H Holding times for preparation or analysis exceeded

N Analyte not NELAC certified

B Analyte detected in the associated method blank

E Estimated (value above quantitation range)

S Spike Recovery outside limits due to matrix

Narr See case narrative

F Analyzed in the lab which is a deviation from the method

< Less than Result value

2012T82-002

Analyses Date Analyzed Dilution

Factor BatchIDUnitsQual

Reporting

Limit Result

Client:

Groundwater

12/29/2020 11:56:00 AM

MW-2

Matrix:

Collection Date:

Client Sample ID:

Stanley Assemblage

Cardno

Lab ID:

Project Name:

Analyst

(SW5030B)TCL VOLATILE ORGANICS SW8260D

trans-1,3-Dichloropropene BRL 5.0 ug/L 308188 1 12/30/2020 13:13 OM

Trichloroethene BRL 5.0 ug/L 308188 1 12/30/2020 13:13 OM

Trichlorofluoromethane BRL 5.0 ug/L 308188 1 12/30/2020 13:13 OM

Vinyl chloride BRL 2.0 ug/L 308188 1 12/30/2020 13:13 OM

Surr: 4-Bromofluorobenzene 98.2 74.9-127 %REC 308188 1 12/30/2020 13:13 OM

Surr: Dibromofluoromethane 106 78.9-121 %REC 308188 1 12/30/2020 13:13 OM

Surr: Toluene-d8 100 81.5-120 %REC 308188 1 12/30/2020 13:13 OM

Qualifiers: * Value exceeds maximum contaminant level

BRL Below reporting limit

H Holding times for preparation or analysis exceeded

N Analyte not NELAC certified

B Analyte detected in the associated method blank

E Estimated (value above quantitation range)

S Spike Recovery outside limits due to matrix

Narr See case narrative

F Analyzed in the lab which is a deviation from the method

< Less than Result value

2012T82-003

Analyses Date Analyzed Dilution

Factor BatchIDUnitsQual

Reporting

Limit Result

Client:

Groundwater

12/29/2020 11:58:00 AM

MW-2

Matrix:

Collection Date:

Client Sample ID:

Stanley Assemblage

Cardno

Lab ID:

Project Name:

Analyst

(SW5030B)TCL VOLATILE ORGANICS SW8260D

1,1,1-Trichloroethane BRL 5.0 ug/L 308188 1 12/30/2020 13:37 OM

1,1,2,2-Tetrachloroethane BRL 5.0 ug/L 308188 1 12/30/2020 13:37 OM

1,1,2-Trichloroethane BRL 5.0 ug/L 308188 1 12/30/2020 13:37 OM

1,1-Dichloroethane BRL 5.0 ug/L 308188 1 12/30/2020 13:37 OM

1,1-Dichloroethene BRL 5.0 ug/L 308188 1 12/30/2020 13:37 OM

1,2,4-Trichlorobenzene BRL 5.0 ug/L 308188 1 12/30/2020 13:37 OM

1,2-Dibromo-3-chloropropane BRL 5.0 ug/L 308188 1 12/30/2020 13:37 OM

1,2-Dibromoethane BRL 5.0 ug/L 308188 1 12/30/2020 13:37 OM

1,2-Dichlorobenzene BRL 5.0 ug/L 308188 1 12/30/2020 13:37 OM

1,2-Dichloroethane BRL 5.0 ug/L 308188 1 12/30/2020 13:37 OM

1,2-Dichloropropane BRL 5.0 ug/L 308188 1 12/30/2020 13:37 OM

1,3-Dichlorobenzene BRL 5.0 ug/L 308188 1 12/30/2020 13:37 OM

1,4-Dichlorobenzene BRL 5.0 ug/L 308188 1 12/30/2020 13:37 OM

2-Butanone BRL 50 ug/L 308188 1 12/30/2020 13:37 OM

2-Hexanone BRL 10 ug/L 308188 1 12/30/2020 13:37 OM

4-Methyl-2-pentanone BRL 10 ug/L 308188 1 12/30/2020 13:37 OM

Acetone BRL 50 ug/L 308188 1 12/30/2020 13:37 OM

Benzene BRL 5.0 ug/L 308188 1 12/30/2020 13:37 OM

Bromodichloromethane BRL 5.0 ug/L 308188 1 12/30/2020 13:37 OM

Bromoform BRL 5.0 ug/L 308188 1 12/30/2020 13:37 OM

Bromomethane BRL 5.0 ug/L 308188 1 12/30/2020 13:37 OM

Carbon disulfide BRL 5.0 ug/L 308188 1 12/30/2020 13:37 OM

Carbon tetrachloride BRL 5.0 ug/L 308188 1 12/30/2020 13:37 OM

Chlorobenzene BRL 5.0 ug/L 308188 1 12/30/2020 13:37 OM

Chloroethane BRL 10 ug/L 308188 1 12/30/2020 13:37 OM

Chloroform BRL 5.0 ug/L 308188 1 12/30/2020 13:37 OM

Chloromethane BRL 10 ug/L 308188 1 12/30/2020 13:37 OM cis-1,2-Dichloroethene BRL 5.0 ug/L 308188 1 12/30/2020 13:37 OM cis-1,3-Dichloropropene BRL 5.0 ug/L 308188 1 12/30/2020 13:37 OM

Cyclohexane BRL 5.0 ug/L 308188 1 12/30/2020 13:37 OM

Dibromochloromethane BRL 5.0 ug/L 308188 1 12/30/2020 13:37 OM

Dichlorodifluoromethane BRL 10 ug/L 308188 1 12/30/2020 13:37 OM

Ethylbenzene BRL 5.0 ug/L 308188 1 12/30/2020 13:37 OM

Freon-113 BRL 10 ug/L 308188 1 12/30/2020 13:37 OM

Isopropylbenzene BRL 5.0 ug/L 308188 1 12/30/2020 13:37 OM m,p-Xylene BRL 5.0 ug/L 308188 1 12/30/2020 13:37 OM

Methyl acetate BRL 5.0 ug/L 308188 1 12/30/2020 13:37 OM

Methyl tert-butyl ether BRL 5.0 ug/L 308188 1 12/30/2020 13:37 OM

Methylcyclohexane BRL 5.0 ug/L 308188 1 12/30/2020 13:37 OM

Methylene chloride BRL 5.0 ug/L 308188 1 12/30/2020 13:37 OM o-Xylene BRL 5.0 ug/L 308188 1 12/30/2020 13:37 OM

Styrene BRL 5.0 ug/L 308188 1 12/30/2020 13:37 OM

Tetrachloroethene 77 5.0 ug/L 308188 1 12/30/2020 13:37 OM

Toluene BRL 5.0 ug/L 308188 1 12/30/2020 13:37 OM trans-1,2-Dichloroethene BRL 5.0 ug/L 308188 1 12/30/2020 13:37 OM

Qualifiers: * Value exceeds maximum contaminant level

BRL Below reporting limit

H Holding times for preparation or analysis exceeded

N Analyte not NELAC certified

B Analyte detected in the associated method blank

E Estimated (value above quantitation range)

S Spike Recovery outside limits due to matrix

Narr See case narrative

F Analyzed in the lab which is a deviation from the method

< Less than Result value

2012T82-003

Analyses Date Analyzed Dilution

Factor BatchIDUnitsQual

Reporting

Limit Result

Client:

Groundwater

12/29/2020 11:58:00 AM

MW-2

Matrix:

Collection Date:

Client Sample ID:

Stanley Assemblage

Cardno

Lab ID:

Project Name:

Analyst

(SW5030B)TCL VOLATILE ORGANICS SW8260D

trans-1,3-Dichloropropene BRL 5.0 ug/L 308188 1 12/30/2020 13:37 OM

Trichloroethene BRL 5.0 ug/L 308188 1 12/30/2020 13:37 OM

Trichlorofluoromethane BRL 5.0 ug/L 308188 1 12/30/2020 13:37 OM

Vinyl chloride BRL 2.0 ug/L 308188 1 12/30/2020 13:37 OM

Surr: 4-Bromofluorobenzene 96.6 74.9-127 %REC 308188 1 12/30/2020 13:37 OM

Surr: Dibromofluoromethane 103 78.9-121 %REC 308188 1 12/30/2020 13:37 OM

Surr: Toluene-d8 100 81.5-120 %REC 308188 1 12/30/2020 13:37 OM

Qualifiers: * Value exceeds maximum contaminant level

BRL Below reporting limit

H Holding times for preparation or analysis exceeded

N Analyte not NELAC certified

B Analyte detected in the associated method blank

E Estimated (value above quantitation range)

S Spike Recovery outside limits due to matrix

Narr See case narrative

F Analyzed in the lab which is a deviation from the method

< Less than Result value

2012T82-004

Analyses Date Analyzed Dilution

Factor BatchIDUnitsQual

Reporting

Limit Result

Client:

Groundwater

12/29/2020 1:20:00 PM

MW-3

Matrix:

Collection Date:

Client Sample ID:

Stanley Assemblage

Cardno

Lab ID:

Project Name:

Analyst

(SW5030B)TCL VOLATILE ORGANICS SW8260D

1,1,1-Trichloroethane BRL 5.0 ug/L 308188 1 12/30/2020 12:24 OM

1,1,2,2-Tetrachloroethane BRL 5.0 ug/L 308188 1 12/30/2020 12:24 OM

1,1,2-Trichloroethane BRL 5.0 ug/L 308188 1 12/30/2020 12:24 OM

1,1-Dichloroethane BRL 5.0 ug/L 308188 1 12/30/2020 12:24 OM

1,1-Dichloroethene BRL 5.0 ug/L 308188 1 12/30/2020 12:24 OM

1,2,4-Trichlorobenzene BRL 5.0 ug/L 308188 1 12/30/2020 12:24 OM

1,2-Dibromo-3-chloropropane BRL 5.0 ug/L 308188 1 12/30/2020 12:24 OM

1,2-Dibromoethane BRL 5.0 ug/L 308188 1 12/30/2020 12:24 OM

1,2-Dichlorobenzene BRL 5.0 ug/L 308188 1 12/30/2020 12:24 OM

1,2-Dichloroethane BRL 5.0 ug/L 308188 1 12/30/2020 12:24 OM

1,2-Dichloropropane BRL 5.0 ug/L 308188 1 12/30/2020 12:24 OM

1,3-Dichlorobenzene BRL 5.0 ug/L 308188 1 12/30/2020 12:24 OM

1,4-Dichlorobenzene BRL 5.0 ug/L 308188 1 12/30/2020 12:24 OM

2-Butanone BRL 50 ug/L 308188 1 12/30/2020 12:24 OM

2-Hexanone BRL 10 ug/L 308188 1 12/30/2020 12:24 OM

4-Methyl-2-pentanone BRL 10 ug/L 308188 1 12/30/2020 12:24 OM

Acetone BRL 50 ug/L 308188 1 12/30/2020 12:24 OM

Benzene BRL 5.0 ug/L 308188 1 12/30/2020 12:24 OM

Bromodichloromethane BRL 5.0 ug/L 308188 1 12/30/2020 12:24 OM

Bromoform BRL 5.0 ug/L 308188 1 12/30/2020 12:24 OM

Bromomethane BRL 5.0 ug/L 308188 1 12/30/2020 12:24 OM

Carbon disulfide BRL 5.0 ug/L 308188 1 12/30/2020 12:24 OM

Carbon tetrachloride BRL 5.0 ug/L 308188 1 12/30/2020 12:24 OM

Chlorobenzene BRL 5.0 ug/L 308188 1 12/30/2020 12:24 OM

Chloroethane BRL 10 ug/L 308188 1 12/30/2020 12:24 OM

Chloroform BRL 5.0 ug/L 308188 1 12/30/2020 12:24 OM

Chloromethane BRL 10 ug/L 308188 1 12/30/2020 12:24 OM cis-1,2-Dichloroethene BRL 5.0 ug/L 308188 1 12/30/2020 12:24 OM cis-1,3-Dichloropropene BRL 5.0 ug/L 308188 1 12/30/2020 12:24 OM

Cyclohexane BRL 5.0 ug/L 308188 1 12/30/2020 12:24 OM

Dibromochloromethane BRL 5.0 ug/L 308188 1 12/30/2020 12:24 OM

Dichlorodifluoromethane BRL 10 ug/L 308188 1 12/30/2020 12:24 OM

Ethylbenzene BRL 5.0 ug/L 308188 1 12/30/2020 12:24 OM

Freon-113 BRL 10 ug/L 308188 1 12/30/2020 12:24 OM

Isopropylbenzene BRL 5.0 ug/L 308188 1 12/30/2020 12:24 OM m,p-Xylene BRL 5.0 ug/L 308188 1 12/30/2020 12:24 OM

Methyl acetate BRL 5.0 ug/L 308188 1 12/30/2020 12:24 OM

Methyl tert-butyl ether BRL 5.0 ug/L 308188 1 12/30/2020 12:24 OM

Methylcyclohexane BRL 5.0 ug/L 308188 1 12/30/2020 12:24 OM

Methylene chloride BRL 5.0 ug/L 308188 1 12/30/2020 12:24 OM o-Xylene BRL 5.0 ug/L 308188 1 12/30/2020 12:24 OM

Styrene BRL 5.0 ug/L 308188 1 12/30/2020 12:24 OM

Tetrachloroethene 650 50 ug/L 308188 10 12/30/2020 14:27 OM

Toluene BRL 5.0 ug/L 308188 1 12/30/2020 12:24 OM trans-1,2-Dichloroethene BRL 5.0 ug/L 308188 1 12/30/2020 12:24 OM

Qualifiers: * Value exceeds maximum contaminant level

BRL Below reporting limit

H Holding times for preparation or analysis exceeded

N Analyte not NELAC certified

B Analyte detected in the associated method blank

E Estimated (value above quantitation range)

S Spike Recovery outside limits due to matrix

Narr See case narrative

F Analyzed in the lab which is a deviation from the method

< Less than Result value

2012T82-004

Analyses Date Analyzed Dilution

Factor BatchIDUnitsQual

Reporting

Limit Result

Client:

Groundwater

12/29/2020 1:20:00 PM

MW-3

Matrix:

Collection Date:

Client Sample ID:

Stanley Assemblage

Cardno

Lab ID:

Project Name:

Analyst

(SW5030B)TCL VOLATILE ORGANICS SW8260D

trans-1,3-Dichloropropene BRL 5.0 ug/L 308188 1 12/30/2020 12:24 OM

Trichloroethene BRL 5.0 ug/L 308188 1 12/30/2020 12:24 OM

Trichlorofluoromethane BRL 5.0 ug/L 308188 1 12/30/2020 12:24 OM

Vinyl chloride BRL 2.0 ug/L 308188 1 12/30/2020 12:24 OM

Surr: 4-Bromofluorobenzene 96.5 74.9-127 %REC 308188 1 12/30/2020 12:24 OM

Surr: 4-Bromofluorobenzene 98.8 74.9-127 %REC 308188 10 12/30/2020 14:27 OM

Surr: Dibromofluoromethane 102 78.9-121 %REC 308188 1 12/30/2020 12:24 OM

Surr: Dibromofluoromethane 101 78.9-121 %REC 308188 10 12/30/2020 14:27 OM

Surr: Toluene-d8 99.3 81.5-120 %REC 308188 1 12/30/2020 12:24 OM

Surr: Toluene-d8 99.4 81.5-120 %REC 308188 10 12/30/2020 14:27 OM

Qualifiers: * Value exceeds maximum contaminant level

BRL Below reporting limit

H Holding times for preparation or analysis exceeded

N Analyte not NELAC certified

B Analyte detected in the associated method blank

E Estimated (value above quantitation range)

S Spike Recovery outside limits due to matrix

Narr See case narrative

F Analyzed in the lab which is a deviation from the method

< Less than Result value

2012T82-005

Analyses Date Analyzed Dilution

Factor BatchIDUnitsQual

Reporting

Limit Result

Client:

Aqueous

12/29/2020

TB-122920

Matrix:

Collection Date:

Client Sample ID:

Stanley Assemblage

Cardno

Lab ID:

Project Name:

Analyst

(SW5030B)TCL VOLATILE ORGANICS SW8260D

1,1,1-Trichloroethane BRL 5.0 ug/L 308188 1 12/30/2020 11:34 OM

1,1,2,2-Tetrachloroethane BRL 5.0 ug/L 308188 1 12/30/2020 11:34 OM

1,1,2-Trichloroethane BRL 5.0 ug/L 308188 1 12/30/2020 11:34 OM

1,1-Dichloroethane BRL 5.0 ug/L 308188 1 12/30/2020 11:34 OM

1,1-Dichloroethene BRL 5.0 ug/L 308188 1 12/30/2020 11:34 OM

1,2,4-Trichlorobenzene BRL 5.0 ug/L 308188 1 12/30/2020 11:34 OM

1,2-Dibromo-3-chloropropane BRL 5.0 ug/L 308188 1 12/30/2020 11:34 OM

1,2-Dibromoethane BRL 5.0 ug/L 308188 1 12/30/2020 11:34 OM

1,2-Dichlorobenzene BRL 5.0 ug/L 308188 1 12/30/2020 11:34 OM

1,2-Dichloroethane BRL 5.0 ug/L 308188 1 12/30/2020 11:34 OM

1,2-Dichloropropane BRL 5.0 ug/L 308188 1 12/30/2020 11:34 OM

1,3-Dichlorobenzene BRL 5.0 ug/L 308188 1 12/30/2020 11:34 OM

1,4-Dichlorobenzene BRL 5.0 ug/L 308188 1 12/30/2020 11:34 OM

2-Butanone BRL 50 ug/L 308188 1 12/30/2020 11:34 OM

2-Hexanone BRL 10 ug/L 308188 1 12/30/2020 11:34 OM

4-Methyl-2-pentanone BRL 10 ug/L 308188 1 12/30/2020 11:34 OM

Acetone BRL 50 ug/L 308188 1 12/30/2020 11:34 OM

Benzene BRL 5.0 ug/L 308188 1 12/30/2020 11:34 OM

Bromodichloromethane BRL 5.0 ug/L 308188 1 12/30/2020 11:34 OM

Bromoform BRL 5.0 ug/L 308188 1 12/30/2020 11:34 OM

Bromomethane BRL 5.0 ug/L 308188 1 12/30/2020 11:34 OM

Carbon disulfide BRL 5.0 ug/L 308188 1 12/30/2020 11:34 OM

Carbon tetrachloride BRL 5.0 ug/L 308188 1 12/30/2020 11:34 OM

Chlorobenzene BRL 5.0 ug/L 308188 1 12/30/2020 11:34 OM

Chloroethane BRL 10 ug/L 308188 1 12/30/2020 11:34 OM

Chloroform BRL 5.0 ug/L 308188 1 12/30/2020 11:34 OM

Chloromethane BRL 10 ug/L 308188 1 12/30/2020 11:34 OM cis-1,2-Dichloroethene BRL 5.0 ug/L 308188 1 12/30/2020 11:34 OM cis-1,3-Dichloropropene BRL 5.0 ug/L 308188 1 12/30/2020 11:34 OM

Cyclohexane BRL 5.0 ug/L 308188 1 12/30/2020 11:34 OM

Dibromochloromethane BRL 5.0 ug/L 308188 1 12/30/2020 11:34 OM

Dichlorodifluoromethane BRL 10 ug/L 308188 1 12/30/2020 11:34 OM

Ethylbenzene BRL 5.0 ug/L 308188 1 12/30/2020 11:34 OM

Freon-113 BRL 10 ug/L 308188 1 12/30/2020 11:34 OM

Isopropylbenzene BRL 5.0 ug/L 308188 1 12/30/2020 11:34 OM m,p-Xylene BRL 5.0 ug/L 308188 1 12/30/2020 11:34 OM

Methyl acetate BRL 5.0 ug/L 308188 1 12/30/2020 11:34 OM

Methyl tert-butyl ether BRL 5.0 ug/L 308188 1 12/30/2020 11:34 OM

Methylcyclohexane BRL 5.0 ug/L 308188 1 12/30/2020 11:34 OM

Methylene chloride BRL 5.0 ug/L 308188 1 12/30/2020 11:34 OM o-Xylene BRL 5.0 ug/L 308188 1 12/30/2020 11:34 OM

Styrene BRL 5.0 ug/L 308188 1 12/30/2020 11:34 OM

Tetrachloroethene BRL 5.0 ug/L 308188 1 12/30/2020 11:34 OM

Toluene BRL 5.0 ug/L 308188 1 12/30/2020 11:34 OM trans-1,2-Dichloroethene BRL 5.0 ug/L 308188 1 12/30/2020 11:34 OM

Qualifiers: * Value exceeds maximum contaminant level

BRL Below reporting limit

H Holding times for preparation or analysis exceeded

N Analyte not NELAC certified

B Analyte detected in the associated method blank

E Estimated (value above quantitation range)

S Spike Recovery outside limits due to matrix

Narr See case narrative

F Analyzed in the lab which is a deviation from the method

< Less than Result value

2012T82-005

Analyses Date Analyzed Dilution

Factor BatchIDUnitsQual

Reporting

Limit Result

Client:

Aqueous

12/29/2020

TB-122920

Matrix:

Collection Date:

Client Sample ID:

Stanley Assemblage

Cardno

Lab ID:

Project Name:

Analyst

(SW5030B)TCL VOLATILE ORGANICS SW8260D

trans-1,3-Dichloropropene BRL 5.0 ug/L 308188 1 12/30/2020 11:34 OM

Trichloroethene BRL 5.0 ug/L 308188 1 12/30/2020 11:34 OM

Trichlorofluoromethane BRL 5.0 ug/L 308188 1 12/30/2020 11:34 OM

Vinyl chloride BRL 2.0 ug/L 308188 1 12/30/2020 11:34 OM

Surr: 4-Bromofluorobenzene 96.9 74.9-127 %REC 308188 1 12/30/2020 11:34 OM

Surr: Dibromofluoromethane 104 78.9-121 %REC 308188 1 12/30/2020 11:34 OM

Surr: Toluene-d8 100 81.5-120 %REC 308188 1 12/30/2020 11:34 OM

Qualifiers: * Value exceeds maximum contaminant level

BRL Below reporting limit

H Holding times for preparation or analysis exceeded

N Analyte not NELAC certified

B Analyte detected in the associated method blank

E Estimated (value above quantitation range)

S Spike Recovery outside limits due to matrix

Narr See case narrative

F Analyzed in the lab which is a deviation from the method

< Less than Result value

Analytical Environmental Services, Inc Date: 4-Jan-21

Analyses Dilution

Factor BatchIDUnitsQual

Reporting

Limit Result

SUMMARY OF ANALYTES DETECTED

2012T82-001

Groundwater12/29/2020 3:37:00 PM

MW-1

Matrix:Collection Date:

Client Sample ID: Lab ID:

(SW5030B)TCL VOLATILE ORGANICS SW8260D

Tetrachloroethene 330 50 ug/L 308188 10

2012T82-002

Groundwater12/29/2020 11:56:00 AM

MW-2

Matrix:Collection Date:

Client Sample ID: Lab ID:

(SW5030B)TCL VOLATILE ORGANICS SW8260D

Tetrachloroethene 80 5.0 ug/L 308188 1

2012T82-003

Groundwater12/29/2020 11:58:00 AM

MW-2

Matrix:Collection Date:

Client Sample ID: Lab ID:

(SW5030B)TCL VOLATILE ORGANICS SW8260D

Tetrachloroethene 77 5.0 ug/L 308188 1

2012T82-004

Groundwater12/29/2020 1:20:00 PM

MW-3

Matrix:Collection Date:

Client Sample ID: Lab ID:

(SW5030B)TCL VOLATILE ORGANICS SW8260D

Tetrachloroethene 650 50 ug/L 308188 10

H Holding times for preparation or analysis exceeded

Qualifiers: * Value exceeds maximum contaminant level

BRL Below reporting limit

N Analyte not NELAC certified

B Analyte detected in the associated method blank

E Estimated (value above quantitation range)

S Spike Recovery outside limits due to matrix

Narr See case narrative

F Analyzed in the lab which is a deviation from the method

< Less than Result value

SAMPLE/COOLER RECEIPT CHECKLIST

1. Client Name: AES Work Order Number:

2. Carrier: FedEx UPS USPS Client Courier Other

Yes No N/A Details Comments

3. Shipping container/cooler received in good condition? damaged leaking other

4. Custody seals present on shipping container?

5. Custody seals intact on shipping container?

6. Temperature blanks present?

7.

Cooler temperature(s) within limits of 0‐6⁰C? [See item 13 and 14 for temperature recordings.]

Cooling initiated for recently collected samples / ice present

8. Chain of Custody (COC) present?

9. Chain of Custody signed, dated, and timed when relinquished and received?

10. Sampler name and/or signature on COC?

11. Were all samples received within holding time?

12. TAT marked on the COC? If no TAT indicated, proceeded with standard TAT per Terms & Conditions.

13. Cooler 1 Temperature ⁰C Cooler 2 Temperature ⁰C Cooler 3 Temperature ⁰C Cooler 4 Temperature ⁰C

Cooler 5 Temperature ⁰C Cooler 6 Temperature ⁰C Cooler 7 Temperature ⁰C Cooler 8 Temperature ⁰C

15. Comments:

I certify that I have completed sections 1‐15 (dated initials).

Yes No N/A Details Comments

16. Were sample containers intact upon receipt?

17. Custody seals present on sample containers?

18. Custody seals intact on sample containers?

19. Do sample container labels match the COC?

incomplete info illegible no label other

20. Are analyses requested indicated on the COC?

21. Were all of the samples listed on the COC received?

samples received but not listed on COC samples listed on COC not received

22. Was the sample collection date/time noted?

23. Did we receive sufficient sample volume for indicated analyses?

24. Were samples received in appropriate containers?

25. Were VOA samples received without headspace (< 1/4" bubble)?

26. Were trip blanks submitted? listed on COC not listed on COC

27. Comments:

I certify that I have completed sections 16-27 (dated initials).

Yes No N/A Details Comments

28. Have containers needing chemical preservation been checked? *

29. Containers meet preservation guidelines?

30. Was pH adjusted at Sample Receipt?

I certify that I have completed sections 28‐30 (dated initials).

tech Typewritten Text

Client:

BatchID:Workorder:

Project Name:

ANALYTICAL QC SUMMARY REPORT

Stanley Assemblage

2012T82

Cardno

308188

RPT Limit QualAnalyte Result SPK value SPK Ref Val %REC Low Limit High Limit RPD Ref Val %RPD RPD Limit

SampleType: BatchID: Analysis Date: Seq No:TestCode: 308188MBLK 12/30/2020TCL VOLATILE ORGANICS SW8260D

Units: Prep Date:Sample ID: Client ID: Run No:ug/L 12/30/2020 443392MB-308188

10107243

1,1,1-Trichloroethane 5.0BRL

1,1,2,2-Tetrachloroethane 5.0BRL

1,1,2-Trichloroethane 5.0BRL

1,1-Dichloroethane 5.0BRL

1,1-Dichloroethene 5.0BRL

1,2,4-Trichlorobenzene 5.0BRL

1,2-Dibromo-3-chloropropane 5.0BRL

1,2-Dibromoethane 5.0BRL

1,2-Dichlorobenzene 5.0BRL

1,2-Dichloroethane 5.0BRL

1,2-Dichloropropane 5.0BRL

1,3-Dichlorobenzene 5.0BRL

1,4-Dichlorobenzene 5.0BRL

2-Butanone 50BRL

2-Hexanone 10BRL

4-Methyl-2-pentanone 10BRL

Acetone 50BRL

Benzene 5.0BRL

Bromodichloromethane 5.0BRL

Bromoform 5.0BRL

Bromomethane 5.0BRL

Carbon disulfide 5.0BRL

Carbon tetrachloride 5.0BRL

Chlorobenzene 5.0BRL

Chloroethane 10BRL

Chloroform 5.0BRL

Chloromethane 10BRL

Qualifiers:

J Estimated value detected below Reporting Limit

BRL Below reporting limit H Holding times for preparation or analysis exceeded

N Analyte not NELAC certified

B Analyte detected in the associated method blank

E Estimated (value above quantitation range)

S Spike Recovery outside limits due to matrix

< Less than Result value> Greater than Result value

R RPD outside limits due to matrix

Rpt Lim Reporting Limit

BatchID:Workorder:

Project Name:

ANALYTICAL QC SUMMARY REPORT

Stanley Assemblage

2012T82

Cardno

308188

RPT Limit QualAnalyte Result SPK value SPK Ref Val %REC Low Limit High Limit RPD Ref Val %RPD RPD Limit

SampleType: BatchID: Analysis Date: Seq No:TestCode: 308188MBLK 12/30/2020TCL VOLATILE ORGANICS SW8260D

Units: Prep Date:Sample ID: Client ID: Run No:ug/L 12/30/2020 443392MB-308188

10107243 cis-1,2-Dichloroethene 5.0BRL cis-1,3-Dichloropropene 5.0BRL

Cyclohexane 5.0BRL

Dibromochloromethane 5.0BRL

Dichlorodifluoromethane 10BRL

Ethylbenzene 5.0BRL

Freon-113 10BRL

Isopropylbenzene 5.0BRL m,p-Xylene 5.0BRL

Methyl acetate 5.0BRL

Methyl tert-butyl ether 5.0BRL

Methylcyclohexane 5.0BRL

Methylene chloride 5.0BRL o-Xylene 5.0BRL

Styrene 5.0BRL

Tetrachloroethene 5.0BRL

Toluene 5.0BRL trans-1,2-Dichloroethene 5.0BRL trans-1,3-Dichloropropene 5.0BRL

Trichloroethene 5.0BRL

Trichlorofluoromethane 5.0BRL

Vinyl chloride 2.0BRL

Surr: 4-Bromofluorobenzene 048.35 50.00 96.7 74.9 127

Surr: Dibromofluoromethane 051.12 50.00 102 78.9 121

Surr: Toluene-d8 050.47 50.00 101 81.5 120

Qualifiers:

J Estimated value detected below Reporting Limit

BRL Below reporting limit H Holding times for preparation or analysis exceeded

N Analyte not NELAC certified

B Analyte detected in the associated method blank

E Estimated (value above quantitation range)

S Spike Recovery outside limits due to matrix

< Less than Result value> Greater than Result value

R RPD outside limits due to matrix

BatchID:Workorder:

Project Name:

ANALYTICAL QC SUMMARY REPORT

Stanley Assemblage

2012T82

Cardno

308188

RPT Limit QualAnalyte Result SPK value SPK Ref Val %REC Low Limit High Limit RPD Ref Val %RPD RPD Limit

SampleType: BatchID: Analysis Date: Seq No:TestCode: 308188LCS 12/30/2020TCL VOLATILE ORGANICS SW8260D

Units: Prep Date:Sample ID: Client ID: Run No:ug/L 12/30/2020 443392LCS-308188

10107239

1,1-Dichloroethene 5.045.84 50.00 91.7 69 136

Benzene 5.050.58 50.00 101 73.7 126

Chlorobenzene 5.051.37 50.00 103 73.5 124

Toluene 5.050.58 50.00 101 76.8 125

Trichloroethene 5.054.24 50.00 108 70.9 124

Surr: 4-Bromofluorobenzene 047.68 50.00 95.4 74.9 127

Surr: Dibromofluoromethane 051.77 50.00 104 78.9 121

Surr: Toluene-d8 050.71 50.00 101 81.5 120

RPT Limit QualAnalyte Result SPK value SPK Ref Val %REC Low Limit High Limit RPD Ref Val %RPD RPD Limit

SampleType: BatchID: Analysis Date: Seq No:TestCode: 308188MS 12/30/2020TCL VOLATILE ORGANICS SW8260D

MW-3 Units: Prep Date:Sample ID: Client ID: Run No:ug/L 12/30/2020 4433922012T82-004AMS

10107338

1,1-Dichloroethene 50226.8 200.0 113 63.8 146

Benzene 50223.7 200.0 112 70.2 137

Chlorobenzene 50231.3 200.0 116 72.7 141

Toluene 50232.7 200.0 116 67 141

Trichloroethene 50244.5 200.0 122 69.3 141

Surr: 4-Bromofluorobenzene 0494.0 500.0 98.8 74.9 127

Surr: Dibromofluoromethane 0508.2 500.0 102 78.9 121

Surr: Toluene-d8 0493.8 500.0 98.8 81.5 120

RPT Limit QualAnalyte Result SPK value SPK Ref Val %REC Low Limit High Limit RPD Ref Val %RPD RPD Limit

SampleType: BatchID: Analysis Date: Seq No:TestCode: 308188MSD 12/30/2020TCL VOLATILE ORGANICS SW8260D

MW-3 Units: Prep Date:Sample ID: Client ID: Run No:ug/L 12/30/2020 4433922012T82-004AMSD

10107345

1,1-Dichloroethene 50210.1 20.8200.0 105 63.8 146 226.8 7.64

Benzene 50220.6 20200.0 110 70.2 137 223.7 1.40

Qualifiers:

J Estimated value detected below Reporting Limit

BRL Below reporting limit H Holding times for preparation or analysis exceeded

N Analyte not NELAC certified

B Analyte detected in the associated method blank

E Estimated (value above quantitation range)

S Spike Recovery outside limits due to matrix

< Less than Result value> Greater than Result value

R RPD outside limits due to matrix

BatchID:Workorder:

Project Name:

ANALYTICAL QC SUMMARY REPORT

Stanley Assemblage

2012T82

Cardno

308188

RPT Limit QualAnalyte Result SPK value SPK Ref Val %REC Low Limit High Limit RPD Ref Val %RPD RPD Limit

SampleType: BatchID: Analysis Date: Seq No:TestCode: 308188MSD 12/30/2020TCL VOLATILE ORGANICS SW8260D

MW-3 Units: Prep Date:Sample ID: Client ID: Run No:ug/L 12/30/2020 4433922012T82-004AMSD

10107345

Chlorobenzene 50228.8 20200.0 114 72.7 141 231.3 1.09

Toluene 50230.8 20200.0 115 67 141 232.7 0.820

Trichloroethene 50236.4 17.9200.0 118 69.3 141 244.5 3.37

Surr: 4-Bromofluorobenzene 0494.8 0500.0 99.0 74.9 127 494.0 0

Surr: Dibromofluoromethane 0509.4 0500.0 102 78.9 121 508.2 0

Surr: Toluene-d8 0499.0 0500.0 99.8 81.5 120 493.8 0

Qualifiers:

J Estimated value detected below Reporting Limit

BRL Below reporting limit H Holding times for preparation or analysis exceeded

N Analyte not NELAC certified

B Analyte detected in the associated method blank

E Estimated (value above quantitation range)

S Spike Recovery outside limits due to matrix

< Less than Result value> Greater than Result value

R RPD outside limits due to matrix

End of Report

Stanley Assemblage - Phase II ESA Addendum_FINAL_01.11.2021.pdf
Stanley Assemblage - Phase II ESA Addendum Dividers.pdf
GW 12.29.2021 - 2012T82_REPORT.pdf
draft 3 printable
Untitled
Button3:
Button2:
Part 1 Client Name: Cardno
workorder: 2012T82
Part 1 Carrier FedEx: Off
Part 1 UPS: Off
Part 1 USPS: Off
Part 1 Client: On
Part 1 Courier: Off
Part 1 Other:
Part 1 Shipping Container: Yes
Part 1 damaged: Off
Part 1 leaking: Off
Part 1 other: Off
Part 1 damaged leaking other:
Part 1 Custody Seals Present: No
Part 1 Custody seals present on shipping container:
Part 1 Custody seals:
Part 1 Custody Seals intact: NA
Part 1 damaged leaking otherCustody seals intact on shipping container:
Part 1 Text4:
Part 1 Temp:
blanks Present: Yes
Part 1 damaged leaking otherTemperature blanks present:
Part 1 Text5:
Part 1 Cooler temp within limits: yes
Part 1 Cooling initiated for recently collected samples ice present:
Part 1 present: Off
Part 1 Chain of Custody: Yes
Part 1 Cooling initiated for recently collected samples ice presentChain of Custody COC present:
Part 1 Text6:
Part 1 Chain of custody signed: Yes
Part 1 Cooling initiated for recently collected samples ice presentChain of Custody signed dated and timed when reliquished and received:
Part 1 Text7:
Part 1 Sampler name and/or signature on COC: yes
Part 1 Cooling initiated for recently collected samples ice presentSampler name andor signature on COC:
Part 1 Text8:
Part 1 Were the samples recieved within holdingtime: yes
Part 1 Cooling initiated for recently collected samples ice presentWere all samples received within holding time:
Part 1 Text9:
Part 1 TAT marked on the COC: yes
Part 1 If no TAT: Off
Part 1 Cooler 1 Temperature: 0.6
Part 1 Cooler 2 Temperature:
Part 1 Cooler 3 Temperature:
Part 1 Cooler 4 Temperature:
Text2: 14.
Part 1 Cooler 5 Temperature:
Part 1 Cooler 6 Temperature:
Part 1 Cooler 7 Temperature:
Part 1 Cooler 8 Temperature:
Part 1 Comments:
Part 1 I certify that I have completed sections 116 dated intials: NZ 12/30/20
Part 2 Were sample containers intact upon reciept: yes
Part 2 Text2:
Part 2 Text10:
Part 2 Custody seals present: no
Part 2 Text11:
Part 2 Text12:
Part 2 Custody seals intact: NA
Part 2 Text13:
Part 2 Text14:
Part 2 Do sample container labels match the COC: Yes
Part 2 undefined: Off
Part 2 illegible: Off
Part 2 incomplete info illegible no label other:
Part 2 undefined_2: Off
Part 2 other coc: Off
Part 2 Are analyses requested indicated on the COC: yes
Part 2 incomplete info illegible no label otherAre analyses requested indicated on the COC:
Part 2 Text15:
Part 2 Were all of the samples listed on the COC received?: yes
Part 2 Check Box3: Off
Part 2 samples received but not listed on COC samples listed on COC not received:
Part 2 Check Box4: Off
Part 2 Was the sample collection date/time noted?: yes
Part 2 samples received but not listed on COC samples listed on COC not receivedWas the sample collection datetime noted:
Part 2 Text16:
Part 2 Did we receive sufficient sample volume for indicated analyses?: yes
Part 2 samples received but not listed on COC samples listed on COC not receivedDid we receive sufficient sample volume for indicated analyses:
Part 2 Text17:
Part 2 Were samples received in appropriate containers?: yes
Part 2 samples received but not listed on COC samples listed on COC not receivedWere samples received in appropriate containers:
Part 2 Text18:
Part 2 Were VOA samples received without headspace (< 1/4" bubble)?: yes
Part 2 samples received but not listed on COC samples listed on COC not receivedWere VOA samples received without headspace 14 bubble:
Part 2 Text19:
Part 2 Were trip blanks submitted?: yes
Part 2 listed on COC: On
Part 2 not listed on COC: Off
Part 2 listed on COC not listed on COC:
Part 2 Comments:
Text3: This section only applies to samples where pH can be checked at Sample Receipt.
Part 2 I certify that I have completed sections 1527 dated intials: SH 12/30/20
Part 3 Have containers needing chemical preservation been checked?: na
Part 3 Text20:
Part 3 Text23:
Part 3 Containers meet preservation guidelines?: NA
Part 3 Text21:
Part 3 Text24:
Part 3 Was pH adjusted?: na
Part 3 Text22:
Part 3 Text25:
Text4: * Note: Certain analyses require chemical preservation but must be checked in the laboratory and not upon Sample Receipt such as Coliforms, VOCs and Oil & Grease/TPH.
Text5: This also excludes metals by EPA 200.7, 200.8 and 245.1 which will be verified between 16 and 24 hours after preservation.
Part 3 I certify that I have completed sections 2830 dated intials: SH 12/30/20