RFP 104-26 Bus Stop Sign Fabrication and Installation Services SOW.pdf

PDF 816 KB Posted

Attached to
RFP 104-26: Bus Stop Sign Fabrication and Installation Services
Solicitation number
BD-27-1206-40000-40000-131695
Issued by
Massachusetts

About this file

This Scope of Work document, issued by the Massachusetts Bay Transportation Authority (MBTA), requests proposals for bus stop sign fabrication and installation services across the MBTA's 150-route bus network serving 50 municipalities in Eastern Massachusetts. The project encompasses the fabrication and installation of approximately 2,500 double-sided bus stop signs at bus stops across the network over a 12-month period from December 1, 2026 through November 30, 2027. The MBTA will provide vendors with batches of sign changes organized on a corridor basis, including stop location information, latitude, longitude, Stop ID, and stop name, along with descriptions of required work such as sign replacement, signpost replacement, new signpost installation, or sign removal. Vendors must use MBTA-approved digital graphic files without alteration, maintain geotagged documentation of all installations, conduct work in phases on a corridor or route level, and meet recurring progress meetings with the Bus Stop Team. The vendor must also be capable of relocating signs within 72 hours of notification and comply with Dig Safe requirements at least 72 business hours in advance of any excavation.

The material cost estimate provided by the MBTA totals $336,014 and includes galvanized steel sign posts ($70,000), 3M reflective sheeting ($85,344), aluminum sheets ($151,200), printer inks ($19,170), and miscellaneous hardware ($10,300). Front bus stop signs must be either 42" or 53" in height and 14" wide, while rear/generic signs must be 31.75" in height and 12" wide, all fabricated from .080 grade aluminum with digital printing and clear over-laminate featuring ASTM Type III retro-reflectivity (3M 3930 Series High Intensity Prismatic). Signposts must conform to MassDOT Section 840 specifications and include zinc-coated steel construction meeting ASTM-A366 standards with all fasteners and hardware constructed of Type 316L stainless steel. All sample color chips and full-size sign samples must be submitted to the MBTA for approval prior to production. Labor costs vary based on the vendor's installation rate, with the project structured to minimize travel time between stops, typically 1-2 minutes apart.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Bus stop signage replacement program (2026)

Requests for Proposals

Project Overview The Massachusetts Bay Transportation Authority operates bus service in 50 municipalities in Eastern Massachusetts. The bus network comprises 150 routes that serve approximately 6,850 bus stops. Per the MBTA’s 2025 Bus Stop Design Guidelines (BSDG), each bus stop is designated with a bus stop sign that includes the MBTA’s logo, the route(s) and destination(s). Some bus stops require additional generic signs to designate the rear of the bus stop zone (pages 88-90). The location of bus stops and corresponding placement of bus stop signage is managed by the MBTA’s Bus Stop Team, within the Service Planning Department.

An assessment of signage across the MBTA’s bus network determined that 49% of signs are missing, badly faded, or display inaccurate passenger information. Additionally, the MBTA has adopted a new standard for bus stop signage that calls for larger signs that support larger text to increase visibility and legibility of the bus network. The MBTA hereby requests proposals from qualified vendors to fabricate and install 2,500 bus stop signs at bus stops across the MBTA bus network.

Scope of Work The MBTA seeks bus stop sign fabrication and installation services to install approximately 2,500 updated, double-sided bus stop signs at bus stops across the network over a 12-month period from December 1, 2026 – November 30, 2027. Options for additional signage work may be considered depending on the vendor’s performance.

Each bus stop sign may have some aspect that needs to be addressed such as:

• The existing sign is mounted on a bent, damaged signpost and both the post and sign need to be replaced.

• The existing sign is mounted to a signpost or utility pole in good condition, and the sign needs to be replaced.

• Front or rear sign is missing, but the pole is in good condition.

• Front or rear sign is missing and needs a pole installed.

• The existing sign is mounted to an existing signpost or utility pole, but the existing placement is not compliant with BSDG and ADA standards and the new sign must be installed on a new signpost.

• Sign and/or signpost needs to be removed.

The above scenarios will be categorized and will correspond to work instructions given to the vendor.

https://cdn.mbta.com/sites/default/files/2025-02/2025-02-bus-stop-design-guide.pdf

The MBTA will provide the vendor with batches of sign changes that include stop location information, latitude, longitude, the Stop ID, and the stop name (typically “STREET NAME @ CROSS STREET NAME” or an address, along with a description of the change needed (front sign, rear sign, new signpost, etc.). The vendor must use approved digital graphic files provided by the MBTA. The vendor must be able to access the digital library to produce the signs. The vendor must notify the MBTA before they produce signs.

Batches are intended to be provided on a corridor basis, so that multiple signage and/or signpost changes can be implemented while minimizing travel time to/from bus stop locations.

For new signage placement where there are not existing signs or signposts, the MBTA will provide drawings and/or physical markings on the sidewalk to help ensure that bus stop signs and signposts are properly located.

Any excavation to set new signposts will require the contractor to contact Dig Safe at 811 or

(111) 344-7233 at least 72 business hours in advance of when the vendor plans to excavate.

The vendor must record the installation of every sign and/or signpost with a geotagged image that is stored in a location accessible to the Bus Stop Team. To verify work, vendor should provide before and after photos at each location. The vendor must meet with the Bus Stop Team on a recurring basis to review progress and plan future work. The vendor must be able to conduct work in phases on a corridor or route level. The vendor must be able to fabricate signs in phases.

The vendor must be able to relocate signs within 72 hours of being notified to do so by the MBTA Bus Stop Team.

Specifications The following MBTA sign specifications are intended to ensure MBTA bus stop signs appear and perform consistently system wide. With that goal in mind, the following specifications must be adhered to while fabricating and installing MBTA bus stop signage. There are two different types of bus stop signs:

• Signs that display route number and destination information. These signs are placed at the front of the bus stop to designate where riders wait for the bus and are referred to as “front signs.” Each front sign is comprised of two pieces of sheet metal, designated as an “A” piece and a “B” piece. The “A” piece faces the direction of travel, and the “B” piece opposes the direction of travel. The A piece also regulates curbside activity and contains a red banner near the bottom of the sign that displays “NO STOPPING, $100 FINE, TOW ZONE.” The sign that opposes the direction of travel omits this regulatory language. These may also be referred to as the “A” side or the “B” side of the sign.

• Signs that display a graphic bus logo and a “No Parking” roundel. These signs are not required at every bus stop. When required, these signs are placed at the rear of the bus stop zone. These signs are referred to as “rear” or “generic” signs.

Example of a digital file for a front sign showing “A” and “B” pieces

Digital file for a rear/generic sign (left) and diagram indicating mounting specifications (right).

Sign fabrication specifications

1. Front bus stop signs: A pieces and B pieces will be 42” or 53” in height and 14” wide respectively.

2. “Rear” or “generic” bus stop signs are 31.75” in height and 12” wide respectively.

3. .080 grade aluminum shall be used

4. All bus stop signs will be digitally printed using MBTA standards, including bus route information and bus stop ID numbers.

5. All bus stop signs will be printed directly from the digital graphic files provided by the

MBTA. Under no circumstances is the artwork to be altered.

6. All bus stop signs must conform to MassDOT specifications for retro-reflectivity.

They should receive a clear over-laminate, with vertically oriented striping, to help protect the ink and reflective sheeting against degradation, with a degree of reflectivity that conforms to ASTM Type III – engineering grade. ASTM information is provided at: 2014 Traffic Sign Retroreflective Sheeting Identification Guide. The relevant section is as follows:

• For ASTM type III, manufactured by 3M, the 3930 Series is required, i.e. the High

Intensity Prismatic. The 3M Series 3430, Engineering Grade Prismatic, does not meet MassDOT standards.

7. Colors – The red should match Standard Highway Red, as specified in the Federal Highway Administration’s current edition of the Manual of Uniform Traffic Control Devices. In previous sign fabrication efforts using EFI wide-format printers, EFI TRAFFIC YELLOW CMYK PLUS 1M was the preferred option as it appeared to retain a strong color and not wash out in direct sunlight. Sample color chips must be provided to the MBTA for approval because variables in equipment, inks, and quality of output can differ dramatically among vendors.

8. For front signs, A and B pieces pre-drilled holes will be located 8” from the top part of the sign and 3” from the bottom of the sign. Pre-drilled holes shall not interfere with text, numbers, or other important graphic elements of the sign.

9. For rear signs, pre-drilled holes will be located .5” from the top of the part of the sign, and 17” below that on the 31.75” sign.”. Holes have been located to conform to spacing of a P-5 post and minimize impact to the artwork on the front of the sign.

The radius of the bottom of the signs shall be at .75” (not 1.5”).

10. Every sign must be properly prepared in accordance with the manufacturer's directions, including proper preparation of the sign substrate and sheeting to prevent bubbling, for example by using an etch primer on the aluminum.

11. Reflectivity warranty information to be provided by the vendor.

12. Vendors must provide certificates of conformance or materials certifications.

13. Fabricated signs to be installed in the City of Cambridge need to be provided to the city for installation.

Signpost and mounting hardware specifications

1. Signposts shall conform to Section A, 1-2 of MBTA Bus Stop Sign Specifications

(2026).

2. Signpost installation method shall conform to Section A, 3-5 of MBTA Bus Stop Sign

Specifications (2026).

3. Hardware, frames, and other securement fittings shall conform to Section B of MBTA

Bus Stop Sign Specifications (2026).

4. Installation of signs to signposts, wood telephone poles, and metal light poles shall conform with Section C, D, and E, of MBTA Bus Stop Sign Specifications (2026).

Sign placement https://highways.dot.gov/safety/other/visibility/2014-traffic-sign-retroreflective-sheeting-identification-guide

• All MBTA bus stop signposts to be positioned at 18” offset from the face of curb, at the location marked by paint, unless otherwise directed by the Bus Stop Team.

• New front bus stop signs and signposts are to be positioned at 90 degrees/perpendicular to the curb.

• New rear bus stop signs and posts are to be positioned at 60 degrees to the curb.

• For existing signposts that remain in place, the sign can be positioned per the existing post angle. If correctly installed it should be at 45-60 degrees to the curb.

Sample submissions

• Sample color chips will need to be provided by the vendor to the MBTA for approval.

• A full-size sample of the following signs will need to be provided by the vendor to the

MBTA for approval.

o 42” A piece o 42” B piece o 53” A piece o 53” B piece o Generic/rear sign

Cost estimate Based on signage work performed in 2025, the MBTA estimates the following cost of materials:

Item Description Quantity Unit Cost Total Galvanized Steel 10' x 2" x 2" square sign posts 14 Gauge

2500.00 $28.00 $70,000.00

3M ElectroCut Film 1170C, Clear 48" x 140 yds 75030157053

84.00 $486.00 $40,824.00

3M High Intensity Grade Prismatic 3930, White 48" x 140 yds 5075030121653

84.00 $530.00 $44,520.00

080 Aluminium 48" x 96" white/white sheets 700.00 $216.00 $151,200.00 Miscellaneous sundries (nuts, bolts and tools) 1.00 $10,300.0

$10,300.00

Sets of inks for printer 135.00 $142.00 $19,170.00 $336,014.00

Labor cost estimate depends on the rate of installation performed by the vendor, but this plan has been structured to minimize travel time between work sites. In most cases, the travel time between bus stops is approximately 1-2 minutes. Most bus stops in the MBTA network are placed 500’ to 1300’ apart from each other, but roadway networks can warrant lesser or greater distances between stops. Travel times between stops can be affected by construction, traffic, weather, special events, and other factors outside of the MBTA’s control.

Attachments MBTA Bus Stop Design Guide (2025)

Examples of good signage

Sign mounted to signpost

Example of a bus stop sign installed on a P5 post showing the “A” side and “B” side, and the digital artwork file at right.

Sign mounted to streetlight

Example of the “A” and “B” pieces for stop id 191 installed on a streetlight and the digital file for the signage.

https://cdn.mbta.com/sites/default/files/2025-02/2025-02-bus-stop-design-guide.pdf

Sign mounted to e-ink mast

Example of a bus stop sign installed on am e-ink mast showing the “A” side and “B” side, and the digital artwork file at right.

Bus Stop Sign and Sign Post Specifications

PART 1 - General Requirements

1.1 Signpost Materials and Installation Specifications

A. Signpost Specifications

1. P-5 Posts shall fabricated from steel and shall meet the requirements of Section 840 of the

2026 MassDOT Standard Specifications for Highways and Bridges, the Supplemental

Specifications to the Standard Specifications for Highways and Bridges, and the MassDOT

Standard Drawings for Signs and Supports and the Manual on Uniform Traffic Control

Devices.

2. Steel posts shall conform to ASTM-A366. The cross section of the posts shall be square tube formed of 12-gauge (.105” U.S.S. Gauge) cold-rolled carbon steel sheets which have been zinc coated (1.25 oz.) conforming to ASTM-A653, carefully rolled to size and welded directly in the corner by high frequency resistance welding, or equal, and externally scarfed to agree with corner radius.

a. Standard outside corner radius shall be 5/32”, +/- 1/64”

b. All bolts shall conform to ASTM-A307, Class A.

c. All bolts, nuts, and washers shall be Type 316L Stainless Steel.

3. All products and manufacturers shall be pre-approved per Massachusetts Highway

Division Standards – Qualified Traffic Control Equipment List.

B. Installation Methods

1. Front sign posts (Double sided ‘A’ and ‘B’ sign) shall be installed 90-degrees perpendicular to the curb.

2. Rear sign posts (Single sided) shall be installed at 60-degrees to curb to accommodate the sign angle requirements.

3. Ground Installation Method

a. Sign Post Anchor shall be driven to within 3-feet to 4-feet of surface.

b. Anchor sleeve shall be pre-cut so that holes will match and be flush with top of Sign

Post Anchor. Drive anchor sleeve until holes match as noted above. Then drive both the sign post anchor and the anchor sleeve until only one hole is exposed above the ground for bolt connection.

c. Insert sign post and bolt in place.

d. Driving caps must be used to drive posts as to not damage the sign post. Retain 4-feet of depth to reach theoretical frost line.

e. Refer to Part 4 – Installation Details, Detail 4.1

4. Concrete or Bituminous Concrete Surfaces Installation Method

a. Sign Post Anchor shall be driven to within 3-feet to 4-feet of surface.

1) For black top surfaces: Sign Post Anchor can be driven through black top surface without first making a hole.

2) For concrete surfaces: Cut a 12-inch by 12-inch square hole in the concrete surface. Drive sign post into place per specifications. Then infill hole with new concrete around sign post.

b. Anchor sleeve shall be pre-cut so that holes will match and be flush with top of Sign

Post Anchor. Drive anchor sleeve until holes match as noted above. Then drive both the sign post anchor and the anchor sleeve until only one hole is exposed above the ground for bolt connection.

c. Insert sign post and bolt in place.

d. Driving caps must be used to drive posts as to not damage the sign post. Retain 4-feet of depth to reach theoretical frost line.

e. Refer to Part 4 – Installation Details, Detail 4.2

5. Hollow Sidewalk Installation Method

a. Surface mount Sign Post Anchors shall be used at areas where a sign post cannot be driven into the ground.

b. Surface mounted anchors shall not be used on masonry sidewalks. Where surface mount anchors are necessary on masonry sidewalks, a minimum 18” x 18” x 4” concrete pad shall be poured to support the anchor.

c. Refer to Part 4 – Installation Details, Detail 4.3

1.2 Hardware

A. Hardware and Frames

1. Supply sign frames and hardware as indicated on the drawings.

2. Anchors and Inserts: Use Type-316L Stainless-Steel anchors and inserts for exterior installations and elsewhere as required for corrosion resistance. High strength bolts other than anchor bolts, nuts and washers shall conform to ASTM-F3125.

a. Stainless-steel strapping and stainless-steel clips shall meet the requirements of the

2026 MassDOT Standard Specifications for Highways and Bridges.

b. PVC or Neoprene washers shall be used to isolate dissimilar metals. Sign coatings shall not serve as a separation agent.

3. Tamper resistant fasteners to be stainless steel, 3/8 in. dia. button head Phillips socket pinhead.

a. Bolts shall be 3/8” (confirm size) Dia. Type-316L Stainless-Steel Button Head bolts with a slot in head and nut with lock-washer. Minimum of ¼” of threads beyond nuts on all signs after they are securely fastened.

4. All hardware shall be as indicated on drawings: 316L stainless-steel and conform to ASTM

A307, Class A.

5. Where mechanical fasteners and hardware are required, they shall be of adequate thickness, length and construction to properly secure the sign unit. Any visible portion of any mounting device shall be finished to match adjacent sign surface, unless otherwise specified.

6. Non-metallic Washers: Provide rigid PVC or neoprene separators between fasteners and non-compatible materials being joined.

7. Metal fasteners and hardware in contact with dissimilar metals shall have a protective coating or neoprene shields to prevent electrolytic action.

1.3 Sign Mounting Specifications

A. Front sign posts (Double sided ‘A’ and ‘B’ sign) shall be mounted 90-degrees perpendicular to the curb.

B. Rear sign posts shall be mounted at 60-degrees to curb to accommodate the sign angle requirements.

C. Installation of signs to metal sign post

1. All bolts shall conform to ASTM-A307, Class A.

2. All bolts, nuts, and washers shall be Type-316L Stainless-Steel.

3. Bolts shall be 3/8” (confirm size) Dia. Type-316L Stainless-Steel Button Head bolts with a slot in head and nut with lockwasher. Minimum of ¼” of threads beyond nuts on all signs after they are securely fastened.

4. PVC or Neoprene washers shall be used to isolate dissimilar metals. Sign coatings shall not serve as a separation agent.

D. Installation of signs to wood telephone pole

1. When affixing sign to existing telephone poles, Heavy Duty Type-316L Stainless Steel strapping and mounting clips shall be used.

a. Straps and clips shall meet the requirements of the 2026 MassDOT Standard

Specifications for Highways and Bridges.

2. All bolts shall conform to ASTM-A307, Class A.

3. All bolts, nuts, and washers shall be Type-316L Stainless-Steel.

4. Bolts shall be 3/8” (confirm size) Dia. Type-316L Stainless-Steel Button Head bolts with a slot in head and nut with lockwasher. Minimum of ¼” of threads beyond nuts on all signs after they are securely fastened.

5. PVC or Neoprene washers shall be used to isolate dissimilar metals. Sign coatings shall not serve as a separation agent.

E. Installation of signs to metal light pole

1. When affixing sign to existing light poles, Heavy Duty Type-316L Stainless Steel strapping and mounting clips shall be used.

a. Straps and clips shall meet the requirements of the 2026 MassDOT Standard

Specifications for Highways and Bridges.

2. All bolts shall conform to ASTM-A307, Class A.

3. All bolts, nuts, and washers shall be Type-316L Stainless-Steel.

4. Bolts shall be 3/8” (confirm size) Dia. Type-316L Stainless-Steel Button Head bolts with a slot in head and nut with lockwasher. Minimum of ¼” of threads beyond nuts on all signs after they are securely fastened.

5. PVC or Neoprene washers shall be used to isolate dissimilar metals. Sign coatings shall not serve as a separation agent.

PART 2 - Sign Panel Attachment Materials Specification

Part Stainless Steel

Bolts F593 Type 316L

Rivets Not Applicable

Nuts F594 Type 316L

Washers

Compatible with Materials Joined, PVC or Neoprene for isolation of dissimilar metals

PART 3 - Compensation

3.1 Method of Measurement

A. Payment items will be measured by each or lump sum, as noted in section 3.3.

3.2 Basis of Payment

A. Payment items in section 3.3 will be paid for at the contract unit price, which price shall be full compensation for design and construction of the completed structure including all excavation, gravel backfill and compaction. Rock excavation, when encountered, shall be paid under Class B

Rock Excavation.

B. Breakaway P-5 Post Assembly, single or double, shall be considered as one unit.

3.3 Payment Items

A. Sign Post……………………………………………………………….Each

B. Sign Post Anchor………………………………………………………Each

C. Sign Post Sleeve……………………………………………………….Each

D. Surface Mount Post Anchor…………………………………………...Each

PART 4 - Installation Details

4.1 Ground Installation Method:

4.2 Concrete or Bituminous Concrete Surfaces Installation Method:

4.3 Hollow Sidewalk Installation Method:

File details come from the government source that posted it. Updated .