Request for Information / Sources Sought Notice Summary

This is a Request for Information (RFI) and Sources Sought Notice issued by the Department of Veterans Affairs (VA) for the Long Beach VA Medical Center. The notice is for information and planning purposes only and does not constitute a solicitation. The VA is seeking qualified sources capable of providing a Dosimeter Set, specifically one (1) CRC 55W Dose Calibrator with color touch screen and well counter, along with associated accessories including well detector auxiliary lead shield, cesium-137 and europium-152 rod sources, Epson roll printer with twelve rolls of paper, well insert, vial syringe/dipper, protective screen cover, and one year of premier support.

The required product must meet salient characteristics including a touch screen color display, USB/PC communications with software upgrade capability, printer functionality, 28-programmable nuclide keys with at least 80-nuclides in memory, built-in dose calibration and quality control features, automatic chamber QC with linearity testing, compatibility with nuclear medicine information management systems, 256-channel MCA with spectrum analysis, well counter for wipe tests with user-definable protocols, automated well QC including Chi-Square and MDA calculations, manual and automatic ROI capability, pre-set F-18 measurement key, and automated linearity and geometry testing. Responses must be submitted via email to Claudia.hansley@va.gov by August 10, 2026, at 1:00 PM PDT. Respondents should address fourteen numbered questions covering capabilities, business size classifications relative to NAICS 339113 (750 employees), manufacturer status, subcontracting compliance, COTS applicability, lead times, lifecycle support, FDA clearance, leasing options, federal contracts, and pricing. Additionally, respondents must provide detailed Buy America Act compliance information including country of origin, domestic content percentages, manufacturer location, and product designation under applicable trade agreements.

View the file

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

THIS REQUEST FOR INFORMATION (RFI) / SOURCES SOUGHT NOTICE IS ISSUED

SOLELY FOR INFORMATION AND PLANNING PURPOSES.

THIS IS NOT A SOLICITATION.

SUBMISSION OF INFORMATION ABOUT PRICING, DELIVERY, THE MARKET, AND

CAPABILITIES IS HIGHLY ENCOURAGED AND ALLOWED UNDER THIS RFI FOR

PLANNING PURPOSES IN ACCORDANCE WITH (IAW) FAR 15.201(e).

DISCLAIMER

This RFI is issued solely for information and planning purposes and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. IAW FAR 15.201(e), responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI.

SOURCES SOUGHT/RFI DESCRIPTION

This is NOT a solicitation announcement. This is a Sources Sought Notice / RFI only. The purpose of this Sources Sought Notice / RFI is to gain information about potential qualified sources and their size classification relative to NAICS 339113 (size standard of 750 Employees). Responses to this Sources Sought Notice / RFI will be used by the Government to make appropriate acquisition decisions. After review of the responses to this Sources Sought Notice / RFI, further RFIs and/or a solicitation or other announcements may be published.

The Department of Veterans Affairs (VA) is seeking sources capable of providing Dosimeter Set that can address the attached list of DRAFT requirements for Long Beach VA Medical Center.

The list of DRAFT characteristics is intended to be descriptive, not restrictive, of the supplies/services that are required.

If your company is interested in and capable of providing the required supplies/services, please provide the information indicated below. Response to this notice should include company name, address, point of contact, size of business pursuant to the following questions:

(1) Submit your capabilities statement illustrating how your organization can/cannot meet the list of DRAFT/SALIENT CHARACTERISTICS requirements. For instances where your company cannot meet the DRAFT/SALIENT CHARACTERISTICS requirement(s), please explain. For instances where your company can meet the DRAFT/SALIENT CHARACTERISTICS requirement(s), please show how your company meets/exceeds each requirement.

(2) Please review the list of DRAFT/SALIENT CHARACTERISTICS requirements and provide any additional feedback or suggestions. If none, please reply as N/A.

(3) Please indicate the size status and representations of your business, such as but not limited to: Service-Disabled Veteran-Owned Small Business (SDVOSB), Veteran- Owned Small Business (VOSB), HUBZone, Woman Owned Small Business (WOSB), Large Business, etc.

(4) Is your company considered small under the NAICS code identified in this RFI?

(5) Are you the manufacturer, authorized distributor, and/or can your company provide a solution to the required supplies/services described in the list of DRAFT/SALIENT

CHARACTERISTICS?

(6) If you are a large business, do you have any designated/authorized distributors? If so, please provide their company name, telephone, point of contact and size status (if available).

(7) If you’re a small business and you are an authorized distributor/reseller for the items identified above, do you alter; assemble; modify; the items requested in any way? If you do, state how and what is altered; assembled; modified.

(8) Limitations on Subcontracting: How does your business ensure compliance with the limitations on subcontracting as outlined in 13 CFR § 125.6?

(9) Are the items you are identifying/providing considered Commercial of the Shelf (COTS) items as defined in FAR Part 2.101 under commercial items?

(10) Non-Manufacturer Rule: If applicable, can you confirm your business complies with the non-manufacturer rule? Specifically, does your company: Provide a product from a small business manufacturer or processor? Not exceed 500 employees?

Primarily engage in the retail or wholesale trade and normally sell the type of item being supplied? Take ownership or possession of the item(s) with its personnel, equipment or facilities in a manner consistent with industry practice?

(11) What is your lead time to deliver a single unit with all components? Is there scale in lead time with greater quantities? Please elaborate.

(12) What is estimated life span of your solution? What support/services does that entail?

(13) Does your proposed equipment have FDA clearance? Please specify what FDA clearance(s) have been obtained.

(14) Does your organization offer a leasing solution? Please elaborate.

(15) Does your company have a Federal Supply Schedule (FSS) GSA/NAC/SAC/BPA/NASA SEWP or any other Federal Government contract? If so, please provide the contract number(s).

(16) If you are an FSS GSA/NAC/SAC/BPA/NASA SEWP or any other Federal Government contract holder, are all the items/solutions you are providing information about available on your schedule/contract? Please state if all or some items are available on the contract.

(17) General pricing of your products/solution is encouraged. Pricing will be used for the purpose of market research only. It will not be used to evaluate any type of award.

(18) Please provide your SAM.gov Unique Entity ID/Cage Code number.

Buy America Compliance

Respondents shall provide sufficient detail to determine compliance with the Buy American Act, including country of origin, domestic content, and availability of domestic alternatives. Responses should be complete and supported with verifiable information.

1. Please identify the country of origin for the end product(s) being offered. Include the location of final assembly/manufacture.

2. Please provide the percentage of domestic content (by cost) for each product(s).

Describe the origin of the major components.

3. Does your product qualify as a “domestic end product” in accordance with the Buy American Act?

4. If the proposed product is not compliant, are you able to provide a BAA-compliant domestic alternative?

5. Please identify the manufacturer’s name and location for the product(s). Confirm whether the manufacturer is U.S.-based.

6. Identify the country of origin of each product and indicate whether the product qualifies as a U.S.-made or designated-country end product in accordance with the Trade Agreements Act.

Responses to this notice shall be submitted via email to Claudia.hansley@va.gov.

Telephone responses will not be accepted. Responses must be received no later than 10 Aug 2026 by 1:00 PM PDT.

All responses to this Sources Sought/RFI will be used for planning purposes only.

Responses to this Sources Sought Notice / RFI are not considered a request to be added to a prospective bidders list or to receive a copy of the solicitation. If further RFIs and/or a solicitation or other announcement is issued as a result of the information provided from this RFI, all interested parties must respond to the specific posting separately IAW the specifications of that announcement.

SALIENT CHARACTERISTICS

a) Must have a touch screen color display

b) Must have USB/PC Communications and able to do software upgrade via USB or flash drive

c) Must have printer capability

d) Must be 28-programmable nuclide keys and with at least 80-nuclides in memory

e) Must have built-in dose calibration, quality control and self-diagnostics

f) Must have automatic chamber QC including linearity

g) Must be compatible with nuclear medicine information management systems via

USB

h) Must have at least 256 channel MCA with detailed spectrum for identification analysis

i) Must have well counter for wipe tests

j) Must be user-definable protocols for wipe testing

k) Must have automated well QC including Chi-Square and MDA

l) Must have a manual and automatic ROI

m) Must include a pre-set key for F-18 measurements

n) Must be able to report: Well counter reports for autocalibration, system test, MDA, and Chi-

o) Must have squares are archived and searchable by date, type, and activity

p) Must be automated linearity and geometry testing

1 EA – BRAND NAME/PART # CRC 55W Dose Calibrator (color touch screen) with Well Counter

Includes Well Detector Auxiliary Lead Shield, Cesium 137 Rod Source, Europium 152 Rod Source, Epson Roll Printer, 12 roll Epson Paper, Well Insert (alcohol & break resistant) for dose calibrator chamber, Vial Syringe/Dipper, Protective/Removable Screen Cover, 1 Year Premier Support for the CRC-55W Dose Calibrator

File details come from the government source that posted it. Updated .