RFI 36C26225Q0523- MUSE NX.pdf

PDF 168 KB Posted

Attached to
6515--MUSE NX-iRhythm Integration Modules
Solicitation number
36C26225Q0523
Issued by

About this file

This is a Sources Sought Notice/Request for Information (RFI) from the Department of Veterans Affairs seeking information about potential sources capable of providing the MUSE NX upgrade for the GH Healthcare MUSE Cardiology Information Management System at the VA Loma Linda Healthcare System.

The required solution must include brand name software platform and hardware upgrade that will support, integrate, and interface with the current network of electrocardiography equipment, Holter monitoring devices, ECG testing equipment, and GE Healthcare Case Stress testing system deployed throughout AMAVHCS medical facilities. The NAICS code is 334510 with a size standard of 1,250 employees. Responses are due by February 24, 2025 at 4:00 PM PST and must be submitted via email to hayley.nuno@va.gov. Interested vendors should provide detailed information about their capabilities, business size status, FDA clearances, compliance with Buy American Act, lead times, pricing (for market research only), and various other qualifications as outlined in the 19 specific questions provided. The government emphasizes this is not a solicitation and responses will be used for planning purposes only.

View the file

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Sources Sought Notice

*= Required Field Sources Sought Notice

SUBJECT* MUSE NX-iRhythm Integration Modules

GENERAL INFORMATION

CONTRACTING OFFICE’S ZIP CODE* 90815

SOLICITATION NUMBER* 36C26225Q0523

RESPONSE DATE/TIME/ZONE 02-24-2025 4PM PACIFIC TIME, LOS

ANGELES, USA

ARCHIVE 30 DAYS AFTER THE RESPONSE DATE

RECOVERY ACT FUNDS N

SET-ASIDE

PRODUCT SERVICE CODE* 6515

NAICS CODE* 334510

CONTRACTING OFFICE ADDRESS Department of Veterans Affairs Network Contracting Office 22 4811 Airport Plaza Drive Suite 600 Long Beach, CA 90815

POINT OF CONTACT* Contract Specialist Hayley Nuno Hayley.nuno@va.gov

(562) 314-2653

PLACE OF PERFORMANCE

ADDRESS VA Loma Linda Healthcare System 11201 Benton Street

Loma Linda CA

POSTAL CODE 92357

COUNTRY

THIS REQUEST FOR INFORMATION (RFI) / SOURCES SOUGHT NOTICE IS ISSUED

SOLELY FOR INFORMATION AND PLANNING PURPOSES. THIS IS NOT A

SOLICITATION.

SUBMISSION OF INFORMATION ABOUT PRICING, DELIVERY, THE MARKET,

AND CAPABILITIES IS HIGHLY ENCOURAGED AND ALLOWED UNDER THIS RFI

FOR PLANNING PURPOSES IN ACCORDANCE WITH (IAW) FAR 15.201(e).

DISCLAIMER

This RFI is issued solely for information and planning purposes and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. IAW FAR 15.201(e), responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI.

SOURCES SOUGHT/RFI DESCRIPTION

This is NOT a solicitation announcement. This is a Sources Sought Notice / RFI only. The purpose of this Sources Sought Notice / RFI is to gain information about potential qualified sources and their size classification relative to NAICS 334510 (size standard of 1,250 Employees). Responses to this Sources Sought Notice / RFI will be used by the Government to make appropriate acquisition decisions. After review of the responses to this Sources Sought Notice / RFI, further RFIs and/or a solicitation or other announcements may be published.

The Department of Veterans Affairs (VA) is seeking sources capable of providing the Muse Nx upgrade.

The list of DRAFT characteristics is intended to be descriptive, not restrictive, of the supplies/services that are required.

SALIENT CHARACTERISTICS

• Brand Name only software platform and hardware upgrade for the GH Healthcare MUSE Cardiology Information Management System.

• With will support, integrate, and interface with the current network of electrocardiography equipment deployed and utilization throughout the medical facilities within AMAVHCS

• Holter monitoring devices.

• Electrocardiogram (ECG testing equipment

• GE Healthcare Case Stress testing system

If your company is interested and capable of providing the required supplies/services, please provide the information indicated below. Response to this notice should include company name, address, point of contact, size of business pursuant to the following questions:

(1) Submit your capabilities statement illustrating how your organization can/cannot meet the list of SALIENT CHARACTERISTICS requirements. For instances where your company cannot meet the SALIENT CHARACTERISTICS requirement(s), please explain.

For instances where your company can meet the SALIENT CHARACTERISTICS requirement(s), please show how your company meets/exceeds each requirement.

(2) Please review the list of SALIENT CHARACTERISTICS requirements and provide any additional feedback or suggestions. If none, please reply as N/A.

(3) Please indicate the size status and representations of your business, such as but not limited to: Service-Disabled Veteran-Owned Small Business (SDVOSB), Veteran-Owned Small Business (VOSB), HUBZone, Woman Owned Small Business (WOSB), Large Business, etc.

(4) Is your company considered small under the NAICS code identified in this RFI?

(5) Are you the manufacturer, authorized distributor, and/or can your company provide a solution to the required supplies/services described in the list of SALIENT

CHARACTERISTICS.

(6) If you are a large business, do you have any designated/authorized distributors? If so, please provide their company name, telephone, point of contact and size status (if available).

(7) If you’re a small business and you are an authorized distributor/reseller for the items identified above, do you alter; assemble; modify; the items requested in any way? If you do, state how and what is altered; assembled; modified.

(8) Limitations on Subcontracting: How does your business ensure compliance with the limitations on subcontracting as outlined in 13 CFR § 125.6?

(9) Are the items you are identifying/providing considered Commercial of the Shelf (COTS) items as defined in FAR Part 2.101 under commercial items?

(10) Non-Manufacturer Rule: If applicable, can you confirm your business complies with the Non-Manufacturer rule? Specifically, does your company: Provide a product from a small business manufacturer or processor? Not exceed 500 employees? Primarily engage in the retail or wholesale trade and normally sell the type of item being supplied? Take ownership or possession of the item(s) with its personnel, equipment or facilities in a manner consistent with industry practice?

(11) Please indicate whether your product conforms to the requirements of the Buy American Act?

(12) What is your lead time to deliver a single unit with all components? Is there scale in lead time with greater quantities? Please elaborate.

(13) What is estimated life span of your solution? What support/services does that entail?

(14) Does your proposed equipment have FDA clearance? Please specify what FDA clearance(s) have been obtained.

(15) Does your organization offer a leasing solution? Please elaborate.

(16) Does your company have a Federal Supply Schedule (FSS) GSA/NAC/SAC/BPA/NASA SEWP or any other Federal Government contract? If so, please provide the contract number(s).

(17) If you are an FSS GSA/NAC/SAC/BPA/NASA SEWP or any other Federal Government contract holder, are all the items/solutions you are providing information about available on your schedule/contract? Please state if all or some items are available on the contract.

(18) General pricing of your products/solution is encouraged. Pricing will be used for the purpose of market research only. It will not be used to evaluate for any type of award.

(19) Please provide your SAM.gov Unique Entity ID/Cage Code number.

Responses to this notice shall be submitted via email to hayley.nuno@va.gov. Telephone responses will not be accepted. Responses must be received no later than Monday, February 24, 2025 by 4:00 PM PST.

All responses to this Sources Sought/RFI will be used for planning purposes only. Responses to this Sources Sought Notice / RFI are not considered a request to be added to a prospective bidders list or to receive a copy of the solicitation. If further RFIs and/or a solicitation or other announcement is issued as a result of the information provided from this RFI, all interested parties must respond to the specific posting separately IAW the specifications of that announcement.

File details come from the government source that posted it. Updated .