RFI 36C26225Q0334.docx

DOCX document 35 KB Posted

Attached to
6515--Wound Imaging Device
Solicitation number
36C26225Q0334
Issued by

About this file

This is a Request for Information (RFI)/Sources Sought Notice issued by the Department of Veterans Affairs (VA) Loma Linda Healthcare System seeking information about wound imaging devices and software. The VA is specifically interested in products similar to WoundVision's Scout system, which includes imaging devices, software subscriptions, EMR integration, and protection plans. The required solution must provide photographic and thermographic imaging capabilities, precise wound measurement, HIPAA-compliant software, and EMR integration capabilities.

Responses are due by January 16, 2025, at 4:00 PM PT and should be submitted via email to Bridgett.Sharma@VA.gov. Respondents must provide detailed capability statements, business size status under NAICS 334510 (1,250 employee standard), manufacturing/distribution status, FDA clearance information, Buy American Act compliance, delivery timeframes, and pricing information for market research purposes. The agency is particularly interested in information about federal contract vehicles (GSA/NAC/SAC/BPA/NASA SEWP) and compliance with small business requirements including limitations on subcontracting and the non-manufacturer rule.

View the file

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

THIS REQUEST FOR INFORMATION (RFI) / SOURCES SOUGHT NOTICE IS ISSUED SOLELY FOR INFORMATION AND PLANNING PURPOSES. THIS IS NOT A SOLICITATION.

SUBMISSION OF INFORMATION ABOUT PRICING, DELIVERY, THE MARKET, AND CAPABILITIES IS HIGHLY ENCOURAGED AND ALLOWED UNDER THIS RFI FOR PLANNING PURPOSES IN ACCORDANCE WITH (IAW) FAR 15.201(e).

DISCLAIMER

This RFI is issued solely for information and planning purposes and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. IAW FAR 15.201(e), responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI.

RFI/SOURCES SOUGHT DESCRIPTION

This is NOT a solicitation announcement. This is an RFI/Sources Sought Notice only. The purpose of this RFI/Sources Sought Notice is to gain information about potential qualified sources and their size classification relative to NAICS 334510 (size standard of 1,250 Employees). Responses to this RFI/Sources Sought Notice will be used by the Government to make appropriate acquisition decisions. After review of the responses to this RFI/Sources Sought Notice, further RFIs and/or a solicitation or other announcements may be published.

The Department of Veterans Affairs (VA) is seeking sources capable of providing wound imaging devices and software for the VA Loma Linda Healthcare System and that can address the draft salient characteristics.

Brand Name Information Manufacturer: WoundVision, LLC

Manufacturer Part #
Item Description
QTY

SSL100-SHS

Scout Software Self- Hosted Cloud (1-YR Software Subscription)

1 EACH

(1 YEAR)

SCA200

Scout Imaging Device Purchase

3 EACH

SSL100-EMR

HL7 EMR Integration (1- YR Subscription License)

(1 YEAR)

SCA200-HS

Scout Imaging Device Hot Swap

SPP200

Scout (SCA200) 1-Year Protection Plan

4 EACH

(4 YEARS)

SSL100-PM

Scout Project Management - Service Agreement

SCT100

Scout Clinical Training

1 JOB

Equal-to Product Information:

Main components: Wound Imaging Device and Software Possible Capabilities: See the draft salient characteristics below.

The VA Loma Linda Healthcare System requires a wound imaging device and accompanying software that allows for precise and accurate wound size measurement and temperature measurements.

1) Must be a photographic and thermographic (long-wave infrared) skin and wound imaging device that comes with software

2) Must be able to precisely and accurately measure wound sizes and simultaneously provide a physiological view of the wound or skin

3) Must be able to provide objective and quantitative measurements of the wound and skin temperature changes for physiological documentation of the success of treatment goals and outcomes

4) Software must be HIPAA-compliant

5) Software must be capable of able interfacing with the electronic medical record

The list of draft characteristics is intended to be descriptive, not restrictive, of the supplies and/or services that are required.

If your company is interested and capable of providing the required supplies/services, please provide the information indicated below. Response to this notice should include company name, address, point of contact, size of business pursuant to the following questions:

(1) Submit your capabilities statement illustrating how your organization can/cannot meet the list of draft salient characteristics described below. For instances where your company cannot meet the draft salient characteristic(s), please explain. For instances where your company can meet the draft salient characteristic(s), please show how your company meets/exceeds each requirement.

(2) Please review the list of draft salient characteristics and provide any additional feedback or suggestions. If none, please reply as N/A.

(3) Please indicate the size status and representations of your business, such as but not limited to: Service-Disabled Veteran-Owned Small Business (SDVOSB), Veteran-Owned Small Business (VOSB), HUBZone, Woman Owned Small Business (WOSB), Large Business, etc.

(4) Is your company considered small under the NAICS code identified in this RFI?

(5) Are you the manufacturer, authorized distributor, and/or can your company provide a solution to the required supplies/services described in the list of draft salient characteristics?

(6) If you are a large business, do you have any designated/authorized distributors? If so, please provide their company name, telephone, point of contact and size status (if available).

(7) If you’re a small business and you are an authorized distributor/reseller for the items identified above, do you alter; assemble; modify; the items requested in any way? If you do, state how and what is altered; assembled; modified.

(8) Limitations on Subcontracting: How does your business ensure compliance with the limitations on subcontracting as outlined in 13 CFR § 125.6?

(9) Are the items you are identifying/providing considered Commercial of the Shelf (COTS) items as defined in FAR Part 2.101 under commercial items?

(10) Non-Manufacturer Rule: If applicable, can you confirm your business complies with the Non-Manufacturer rule? Specifically, does your company: Provide a product from a small business manufacturer or processor? Not exceed 500 employees? Primarily engage in the retail or wholesale trade and normally sell the type of item being supplied? Take ownership or possession of the item(s) with its personnel, equipment or facilities in a manner consistent with industry practice?

(11) Please indicate whether your product conforms to the requirements of the Buy American Act?

(12) What is your lead time to deliver a single unit with all components? Is there scale in lead time with greater quantities? Please elaborate.

(13) Does your proposed equipment have FDA clearance? Please specify what FDA clearance(s) have been obtained.

(14) Does your company have a Federal Supply Schedule (FSS) GSA/NAC/SAC/BPA/NASA SEWP or any other Federal Government contract? If so, please provide the contract number(s).

(15) If you are an FSS GSA/NAC/SAC/BPA/NASA SEWP or any other Federal Government contract holder, are all the items/solutions you are providing information about available on your schedule/contract? Please state if all or some items are available on the contract.

(16) General pricing of your products/solution is encouraged. Pricing will be used for the purpose of market research only. It will not be used to evaluate for any type of award.

(17) Please provide your SAM.gov Unique Entity ID number.

Responses to this notice shall be submitted via email to Bridgett.Sharma@VA.gov. Telephone responses will not be accepted. Responses must be received no later than Thursday, January 16, 2025, by 4:00 PM PT.

All responses to this RFI/Sources Sought will be used for planning purposes only. Responses to this RFI/Sources Sought Notice are not considered a request to be added to a prospective bidders list or to receive a copy of the solicitation. If further RFIs and/or a solicitation or other announcement is issued because of the information provided from this RFI, all interested parties must respond to the specific posting separately in accordance with the specifications of that announcement.

File details come from the government source that posted it. Updated .