This is a Request for Information (RFI) issued by the Department of Veterans Affairs, Veteran Health Administration, Network Contracting Office 21, on behalf of VA Palo Alto Health Care System for market research purposes only. The RFI seeks information from qualified contractors regarding the replacement and installation of an updated anti-ligature overhead door alarm system designed to detect and notify caregivers of potential acts of self-harm within the Mental Health Inpatient Wings. The solicitation number is 36C26126Q0397, and responses should be directed to derek.brown7@va.gov. The work is classified under NAICS code 238990 (All Other Specialty Trade Contractors) and PSC 6350 (Miscellaneous Alarm, Signal, and Security Detection Systems). All business sizes are welcome to respond, including Service-Disabled Veteran Owned Small Businesses, Veteran Owned Small Businesses, and other small and large businesses.
The required scope of work includes removal and installation with retrofit of all parts and materials, with the contractor responsible for providing all labor, alarm devices, horns, flashing strobe lights, sensors, delivery, and accessories. Responders must provide company information, point of contact details, unique entity ID from the System of Awards Management, business size classification, information regarding GSA Federal Supply Schedule contracts if applicable, manufacturer authorization letters if relevant, and intended bid submission status. Additionally, respondents should indicate lead time needed from award notification to work commencement and provide recommendations for changes or clarifications to the performance work statement and general requirements. The system specifications include photoelectric beam detection on door frames, strobe or fixed lights at hallway doorsites, hallway horns, touch screen remote displays at nurse stations, capacity for up to 72 doors per control panel, event logging capabilities for 365 days, bypass options, and a silent test option. This RFI does not commit the Government to issue a solicitation or award a contract, and all response costs are the responsibility of the respondent.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Atatchment B - PAD-B520.pdf | ||
| Atatchment A - PAD-B520.pdf | ||
| VAPAHCS Mental Health Over Door Alarms PWS_Draft - Copy.docx | DOCX document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Request for Information This announcement constitutes a Special Notice. The purpose of this document is for market research purposes only. This document does not commit or obligate the Government in any manner. THIS IS NOT a Request for Quote (RFQ) or a Request for Proposal (RFP). This announcement shall not be construed as a commitment by the government to issue a solicitation or award a contract at this time. The documents included in this posting are not finalized.
Summary The Department of Veterans Affairs (VA) Veteran Health Administration (VHA), Network Contracting Office (NCO) 21, on behalf of VA Palo Alto Health Care System (VAPAHCS) has a need to replace the Top Door Alarm Gen1 system and install an updated alarm system to detect and notify caregivers of potential acts of self-harm when a door is used as a ligature point within its Mental Health Inpatient Wings.
This notice is to determine interest and capability of potentially qualified Businesses (All Sizes) relative to the North American Industry Classification code (NAICS): 238990 – All Other Specialty Trade Contractors. The Product Service Code (PSC) will be 6350 – Miscellaneous Alarm, Signal, and Security Detection Systems. The VA is not seeking proposals at this time and will not accept unsolicited proposals. All responses shall be solely in the form of information and materials.
Project Description Remove and install to include retrofit of all parts and materials for an anti-ligature overhead door alarm system. Contractor is to provide all labor, alarm devices, horns, flashing strobe lights sensors, delivery and any or all accessories to complete the project.
Point of Contact Potential offerors having the skills and capabilities necessary to perform the described services below are invited to provide feedback via email to: derek.brown7@va.gov.
All costs associated with responding to this RFI will be the sole responsibility of the respondent. PLEASE NOTE- The Government reserves the right to not respond to any questions received by industry in response to this posting. All submissions will be treated as business confidential materials, become Government property, and will not be returned.
Request for Information Questions:
RESPONSES MUST INCLUDE THE FOLLOWING INFORMATION:
· Company Name:
· Point of Contact (POC) name:
· Email address:
· Phone number:
· Unique Entity ID No. listed in the System of Awards Management (SAM):
· Business Size: (Service-Disabled Veteran Owned Small Business (SDVOSB), Veteran Owned Small Business (VOSB), Small Business Other, Small Business, or Large Business) for the NAICS code 238990.
· Please indicate whether you hold a GSA Federal-Supply-Schedule contract that covers this type of request. If so, please provide the Schedule contract number.
· If you are not the manufacturer of the proposed product, do you have an Authorized Distributorship Letter issued from the manufacturer (If applicable)?
· Does your firm intend to submit a bid for this requirement?
· How much lead time will your company need from notification of award to start of work?
· Are there any recommended changes/additions/clarifications needed to the performance work statement (PWS) that would enable you to adequately respond to an RFQ?
· Are there any recommended changes/additions/clarifications required in general?
· What type of service/warranty do you offer?
· Are there any customary commercial practices for the services/supplies sought?
Salient Characteristics
| • | Top Door Presence Detection - Photoelectric beams installed on the door frame header and top door face |
| • | Strobe or fixed light at each hallway doorsite; |
| • | Hallway horn; and |
| • | Visual and audible room display panel located in the nurse’s station. |
| • | Capacity – customized design provides coverage for up to 72 doors per control panel. |
| • | Self-Monitoring – built-in features allow the system to continuously verify circuit and power supply integrity. |
| • | Event Logging – records time stamped history that are downloadable for 365 days. |
| • | Touch Screen Remote Display – capable of supporting multiple nurse stations to interface with one master control panel. |
| • | By-Pass Options – allows a facility to by-pass a single room or group of rooms and continue to maintain system-wide integrity. |
| • | Silent Test Option – allows the facility to test the system without disturbing patients. |
| • | Local Keyed Reset Switch |
| o | Positioned in the wall beside the door jamb. |
| o | Cylinder is keyed by customer for added security. |
| o | System deactivation and reactivation occur simultaneously. |