Installation of 120'x42" tile at Highway IA-10 and Station 400+00 (MP 87.85) in Buena Vista County
Solicitation number
645-RFB-2031-2026
Issued by
Carroll County, Iowa

About this file

This document is a Highway Right of Way Utility Permit issued by the Iowa Department of Transportation (Iowa DOT), District 3 Office, for a utility installation project in Buena Vista County. The permit #11U-2025-001 authorizes the placement of a 42-inch tile crossing across highway IA 10, specifically located at Highway Station 400+00 (milepost 87.85). The project involves installing 120 feet of 42-inch diameter tile using trenchless construction methods, with work planned for Summer 2025. The permit is valid from 07-23-25 to 07-23-26 and requires the contractor to supply all labor, materials, and equipment for the installation.

The project specifications mandate that materials must meet specific requirements, including restrained joint ductile iron pipe, restrained joint PVC pipe, or steel casing pipe with a minimum wall thickness of 0.375 inches. The installation must follow the Iowa DOT's Standard Specifications for Highway and Bridge Construction Series 2015, Section 2553. Special attention is required to avoid damaging an existing 10-inch tile in the area, with the contractor responsible for any repairs at their own expense. The project includes traffic control requirements (TC-202) and must adhere to standard road plans for subdrain and tile line replacements, ensuring minimal disruption to existing drainage systems.

View the file

Other files

File Type Posted
1331662-event.pdf PDF
Appendix C - Supplemental Spec (2553).pdf PDF
Appendix A - Trenchless Specifications.pdf PDF
A101_2017+sample+2 (1).pdf PDF
Appendix B - Utility Policy.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

IOWA DEPARTMENT OF TRANSPORTATION

District 3 Office 6409 Gordon Dr.

Sioux City, IA 51106

7-23-25

Dear Applicant:

Enclosed is a copy of your approved Highway Right of Way Utility Permit #11U-2025-001 in the name of

. Keep one copy for your records and provide another copy to be made available at the job site during construction.

#11U-2025-001 is for the placement of 42-inch tile crossing across highway IA 10 in Buena Vista County. The area of the proposed construction is located on IA 10 at approximate Highway Station 400+00 to Highway Station 400+00 or milepost 87.85 to milepost 87.85 as shown on attached exhibit in Buena Vista County.

Special Requirements: Refer to attached As-built requirement and Special Requirements. Please contact a minimum of 48hrs in advance to start of construction.

If you have any questions, or need further assistance please feel free to give me a call at the above address.

Sincerely, JR: jr Enclosures

IA 10 Buena Vista

FA 745 B 1

42 inch Tile Crossing at 400+00 or MP 87.85. The tile crossing will be from South ROW to the North ROW. The entire pipe must be jacked when in the ROW. Traffic control will be TC-202.

20,29 93 35 IA 10 .55 West

CO. RD M-54

87.85 400+00 Both

NHSN-010-4(012)--2R-11

11U-2025-001

07-23-26

07-23-25

1. Project number: NHSN-010-4(012)--2R-11

2. Location: 0.55 Miles West of M54 on IA 10

3. Project Description: 42" Tile Crossing using trenchless construction.

4. Cost Estimate:

5. Funding Source:

6. Work Completion Date: Summer 2025

7. DOT Contact:

8. CARS 511 Not needed.

9. Staff Action:

10. Standard Road Plans: TC-1, TC-202, DR-302, DR-122

11. PDF’s of any specs: See # 15

12. Tile Exhibit: See attachments.

13. Aerial Photo: See attachments on permit

14. As-builts: See attachments.

15. Contractor to supply all labor, materials, and equipment to install 120-ft feet of 42” diameter tile across highway 10 and Station 400+00 (MP 87.85) Materials shall meet one of the following requirements:

Section 2553.02 a.2.b. restrained joint ductile iron pipe or restrained joint PVC pipe or Section 2553.02 b steel casing pipe with minimum wall thickness of 0.375 inches. Refer to IM 440 for specifications casing.

Tile crossing from ROW to ROW to be installed via trenchless construction. The trenchless construction shall meet the lowa DOT's Standard Specifications for Highway and Bridge Construction Series 2015, Section 2553.

Do Not damage the existing 10 inch tile in the area, if damaged the contractor will need to fix it at their own expense. The 10 inch tile still needs to be functional.

16. Contractor for Connection:

From:

To:

Subject: FW: Marathon main Date: Wednesday, July 23, 2025 1:32:50 PM Attachments:

Sent: Monday, February 17, 2025 12:15 PM

Subject: Re: Marathon main

CAUTION:

This email originated from outside the Iowa Department of Transportation.

Do not click links or open attachments unless you recognize the sender and know the content is safe.

We will have 3000 feet of 24" and 5000 feet of 36". The pipe size at the road crossing will be 36" and the depth will be almost 9' on the north side and almost 8' on the south side. Stone owns both sides of the crossing. It will be 750 feet east of the driveway or 3000 feet west of M54.

On your map, can you provide sizes of tile that you are proposing. I will need that to size the size of pipe at crossing. What depth will you be at? I can get a list of the property owners off Beason, but will need to send you the permit for signatures of each property owner.

iowadot.gov

Sent: Thursday, February 13, 2025 4:39 PM

Subject: Marathon main

CAUTION:

This email originated from outside the Iowa Department of Transportation.

Do not click links or open attachments unless you recognize the sender and know the content is safe.

I've attached a pdf map of the main we are wanting to install near Marathon. The approximate gps coordinates are 42.850946, -95.003446.

Let me know if you need anything else. Thank you.

https://iowadot.gov/ jraymer Line jraymer Callout Station 400+00 or MP 87.85. 42 inch tile crossing. Farmer plans to pattern tile the area north and south of the roadway with a 36 inch tile. Minimum 8 ft depth at ROW ditch bottom. Bore from ROW to ROW.

necessary.

concrete where

Remove existing

(if necessary)

Connecting band

0.1

0.1

0.1

0.1

0.2

0.2

0.2

0.3

0.3

0.4

0.5

0.6

0.6

0.7

2.0

2.3

2.6

2.8

3.4

4.0

4.5

5.1

5.7

6.2

6.9

7.5

8.1

8.7 inches

D

Diameter, lbs.

Mesh

Wire

N.A.

N.A.

N.A.

N.A.

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

1'-6''

12'' min.

12'' m in.

if necessary

Remove headwall

(if necessary)

Connecting band

12'' min.

12'' min.

Flow

Concrete pipe pipe elbow (if necessary)

Standard prefab corrugated

Corrugated pipe

Variable to new adapter if possible

Tie in old steel reinforcing

Flow

Box Culvert Existing Concrete

Flow

INLET OUTLET

Fillet

1'-6''

Fillet

3''

CONCRETE PIPE TO CONCRETE BOX CULVERT

Corrugated pipe

CONCRETE PIPE TO CORRUGATED PIPE

Concrete pipe

Flow

3'' for 24'' Dia. pipe

'' for 18'' Dia. pipe

Fl ow pipe elbow (if necessary)

Standard prefab corrugated

CORRUGATED PIPE TO CONCRETE PIPE

Concrete pipe

Concrete

cu. yds.

(''C-2'')

Concrete for Fillet

cu. yds.

TYPE ''C-2''

TYPE ''C-3''

TYPE ''C-1''

TYPE ''C-4''

CONCRETE PIPE TO CONCRETE PIPE

T

T

T

FOR "C-2" ADAPTORS

QUANTITIES PER LINEAR FOOT

ESTIMATED ENCASEMENT

min. embedment of culvert with 10"

26" long in top half

Epoxy 4 #5 bars

Standard Road Plan DR-121.

Pipe connector. See

Standard Road Plan DR-121.

Pipe connector. See to match alignment with concrete pipe.

corrugated pipe. Holes may be field drilled in corrugated pipe collar (either tongue or groove end) to a standard section of a method approved by the Engineer for attaching a concrete

Type "C-3" and "C-4" adaptors may be shop fabricated using site using methods approved by the Engineer.

Form and construct Type "C-1" and "C-2" adaptors on the job as directed, will be paid for as "Removal of Existing Structures".

Removal and disposal of headwall, wingwall, or other concrete, indicated is incidental to the pipe culvert.

The cost of furnishing all materials and constructing adaptor as

No payment will be made for individual adaptors.

Thickness of wall of concrete pipe. See AASHTO M 170.

two bolts at approximate equal intervals.

connector holes may be used if available. Place remaining around each connection at equal intervals. Existing pipe

5/8 inch (min.) bolts in 7/8 inch (min.) holes. Four bolts

Positive type joint coupling required.

No. 8 wire - 30lbs/100 sq. ft. Lap ends 6 inches.

Use minimum reinforcing of wire mesh 6" x 6" - W2

Grout opening between pipes.

4 inches.

Thickness same as pipe thickness (T) but not less than

2000 D (Class III) and 3000 D (Class IV) Pipe

DR-122

REVISION

10-18-16

SHEET 1 of 1

REVISIONS:Corrected two typos in general notes.

APPROVED BY DESIGN METHODS ENGINEER

STANDARD ROAD PLAN

PIPE CULVERT CONNECTIONS

CONCRETE ADAPTERS FOR

CONSTRUCTION OF TYPE 'C'

REPLACEMENT SCHEDULE CASE 'A'

( Pipe size in inches )

PROPOSED SUBDRAIN SIZE D 5

Coated CMP Pipe

6Existing tile size + 6''

Concrete Pipe

Existing

Tile

Size

> 24

Depth as required.

Backfill

Earth required

Width as

Backfill

Earth

Limits

Construction

Shoulder

Pavement

Roadway

ROW Line

Existing Tile Subdrain

Top of Backslope

Toe of Foreslope

F lo w

Shoulder

Existing Tile Subdrain Limits

Construction

ROW Line

Remove or Abandon

Temporary Easement for Subdrain

Subdrain

Existing Tile

ROW Line

Variable

L Roadway

Foreslope ROW Line

Original Ground

FLOW

Existing Tile SubdrainExisting Tile Subdrain

CASE ''A''

SECTION A-A

CASE ''A''

SECTION B-B

CASE ''B''

SECTION C-C

TYPICAL PLAN FOR REPLACING OR RELOCATING EXISTING FIELD TILE

CASE ''B'' CASE ''C''CASE ''A''

1 2 1 2

D

1 2

A

C

A line when possible on most direct

Replace subdrain

A

A

A

C

C

B BB

B required

Width as not reconnected but outletted by the roadway and the line is

Where tile line is severed a more parallel alignment and the line is relocated in

Where tile line is within the ROW the line is reconnected.

by the roadway and

Where the tile line is severed ditch drainage into subdrain if approved by adjacent property owners.

downstream property owners. Perforated pipe may be used to allow

Inspection access is required to allow inspection by the upstream and subdrain according to the replacement schedule is required.

Dimension A indicates the R.O.W. limits in which replacement of tile one size larger than existing line.

Replace in kind (size and type) or with 'PE' slotted pipe, a minimum of full capacity for all connected drain systems.

When multiple drains are connected to one outlet, the outlet is to provide

DR-121

DR-305

no additional cost to the Contracting Authority.

Type 1 connection at required, furnish and install a

When concrete culvert pipe of 2000D (Class III) or stronger is by the Engineer.

Cap blind ends of subdrains with a metal cap or as approved drains in a functional condition.

of existing tile drains in such a way as to leave the existing tile minimum of disturbance to existing field tile. Connect to lines

Install relocated or replacement subdrain so as to cause a existing line.

outside the ROW limits using the same size of pipe as access at each end of replaced tile line. Replace tile lines replacement schedule shown below. Install an inspection

Replace tile lines within the ROW limits according to the

.'C', provide the Standard Subdrain Outlet shown in subdrain to outlet into the roadway ditch, as shown in Case

Case 'B'. In cases where new construction requires existing limits, relocate the tile outside the ROW line, as shown in is more parallel to the roadway and within the construction more nearly right angle. Where the existing tile line alignment as shown in Case 'A', relocate the tile line to accomplish a roadway intersects the tile line in an undesirable alignment, project, or outlet them in a ditch or channel. Where the construction, replace them within the ROW limits of the

When the existing tile lines are intercepted by roadway

104-5C

Possible Tabulation:

Subdrain Outlet

Standard Subdrain

Possible Contract Items:

4146.03

Standard Specifications.

of theground. Use PVC meeting the requirements of Article

4 inch diameter inspection access with cap. Minimum of 3 feet above corrugated pipe (Manning's Formula) assuming a 0.20% slope with n=0.013 for concrete pipe and n=0.025 for

Replacement sizes provide equivalent capacity based on a 6 inch settlement see DR-305.

Standard Subdrain Outlet

DR-302

REVISION

4-18-23

SHEET 1 of 1

REVISIONS: Added note 3. Renumbered notes 4-8.

APPROVED BY DESIGN METHODS ENGINEER

STANDARD ROAD PLAN

(FARM TILE REPLACEMENT)

STANDARD

SUBDRAINS

1 2 3

1 2 3 1 2 3 connection is approved by the Engineer.

A t-fitting or saddle connection is required unless an alternate

DR-305

DR-121

4146.03

104-5C http://www.iowadot.gov/design/SRP/IndividualStandards/dr305.pdf http://www.iowadot.gov/design/SRP/IndividualStandards/dr121.pdf ../../GS/content/4146.htm https://iowadot.gov/design/tnt/PDFsandWebFiles/IndividualPDFs/0104-05C.PDF

Traffic Control

Possible Contract Item:

TC-402

TC-202

SLOW-MOVING OPERATION

VEHICLE STOPPED ON SHOULDER FOR LESS THAN ONE HOUR

1000'

Direction of Traffic

Traffic Sign

Or

LEGEND

Pickup

PickupPickup

48" x 48"

W21-6

SURVEY

CREW

48" x 48"

W20-1

ROAD

WORK

AHEAD

TC-402

TC-202

or For work lasting longer than one hour, refer to strobe light.

Equip all vehicles with an amber revolving light or amber whenever appropriate.

lane as possible. Entrances and driveways should be used

When parked, locate vehicles as far from the open traffic

Do not allow work to interfere with the flow of traffic.

TC-1

REVISION

10-15-19

SHEET 1 of 1

REVISIONS:New logo.

APPROVED BY DESIGN METHODS ENGINEER

STANDARD ROAD PLAN

(TWO-LANE OR MULTI-LANE)

WORK NOT AFFECTING TRAFFIC

http://www.iowadot.gov/design/SRP/IndividualStandards/etc402.pdf http://www.iowadot.gov/design/SRP/IndividualStandards/etc202.pdf

END

ROAD WORK

48" x 24"

G20-2A

ROAD

WORK

AHEAD

48" x 48"

W20-1

SHOULDER

DROP

OFF

48" x 48"

W8-9A

END

ROAD WORK

48" x 24"

G20-2A

ROAD

WORK

AHEAD

48" x 48"

W20-1

Traffic Control

Possible Contract Item:

A

B

Shoulder Line

5 devices

T

Length of Work Area

A

LEGEND

Traffic Sign

Work Area

Direction of Traffic

A B C T

100'40'250'500'

700' 350'

500'1000'

80'

100' 200'

200'

40 - 45

50 or greater

35 or less

Spacing = C

42" Channelizer

1107.08 strobe light.

foot centers or use a vehicle with an amber revolving light or amber

For work areas less than 200 feet long, use channelizers spaced at 20

Specifications does not apply. Reduce channelizer spacing to 40 feet.

of the Standard temporary fillet requirement of Article

When the length of a pavement edge drop-off is 1000 feet or less, the

1107.08.K2

For work lasting less than one hour, refer to TC-1.

of the Standard Specifications.

Shoulder edge drop-offs shall be mitigated according to Article during non-working hours.

No pavement edge drop-offs greater than pavement depth will be allowed sign.

When a pavement edge drop-off exists, install a SHOULDER DROP-OFF

TC-202

REVISION

4-18-23

SHEET 1 of 1

REVISIONS: Added speed limit note.

APPROVED BY DESIGN METHODS ENGINEER

STANDARD ROAD PLAN

OF TRAVELED WAY

WORK WITHIN 15 FT

(mph)*

SPEED LIMIT

* Speed Limit refers to regulatory speed limit before road work.

1107.08

1107.08.K2

TC-1

http://www.iowadot.gov/erl/current/GS/content/1107.htm http://www.iowadot.gov/erl/current/GS/content/1107.htm https://iowadot.gov/design/SRP/IndividualStandards/tc001.pdf

AS-BUILT RURAL(no tc213).pdf
As-built Plans 115.8(8)
Special Requirements
dr122.pdf
edr122-001.pdf
dr302.pdf
dr302
tc001.pdf
etc001
tc202.pdf
tc202

File details come from the government source that posted it. Updated .