This is a technical specifications document for RFB 2026-38, a state and local contract opportunity issued by Cazenovia, New York, for elevator modernization services at the Cazenovia Sheriff's building located at 6 Sullivan Street, Cazenovia, NY 13035. The project scope requires the contractor to furnish all labor, materials, and equipment necessary to modernize an existing elevator system. Key specifications include the installation of a new TAC 20 controller or similar microprocessor-based control system compliant with all ADA regulations, replacement of the power unit with a new submersible unit including motor, pump, hydraulic valve, muffler, oil reservoir tank, and hydraulic fluid, and replacement of all hoistway, machine room, and car wiring as necessary. The specifications mandate reuse of existing components including the jack, car sling/platform, car guides, and cab interior where feasible, while new components must be provided for the door operation system, door restrictors, electronic safety edge, car operating panel with brushed stainless steel finish, car arrival lanterns, hall pushbuttons, and hall position indicators. New pit stop switches and a new shutoff valve for the jack are also required, along with removal and disposal of existing oil in compliance with EPA standards and installation of new EPA-compliant oil.
The document does not contain pricing information, set-asides, incumbent contractor details, response or due dates, bidder's meeting information, award dates, or contract term details. The building will be equipped with a County-owned backup generator for full building operation during the project, and the elevator will be connected to this generator during the modernization work. All materials and workmanship must comply with ASME A17.1/CSA B44-2025 Code standards, and the contractor must provide an owner's manual and job specification prints upon completion.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
RFB 2026-38 Attachment 1 – Technical Specifications RFB 2026-38
RFB 2026-38 - CAZENOVIA ELEVATOR MODERNIZATION – REBID
MINIMUM SPECIFICATIONS
Scope: Furnish all labor, materials and equipment to provide elevator modernization at Cazenovia Sherriff’s building @ 6 Sullivan St. Cazenovia NY 13035. This building will have backup generator for full building operation.
General: Contractor shall provide a new TAC 20 controller or similar. The elevator control system will be compliant with all ADA regulations and will be microprocessor-based and software-oriented. The system will operate in real time, continuously analyzing the cars changing position, condition, and workload and will include the following features:
Solid state starter Auto fan/light shutoff Onboard diagnostic tool Tenant security 3-1 Non-proprietary Owner’s manual and job specification prints Tape selector with steel tape and mounting hardware for leveling and limits
Wiring Package: All hoistway, machine room, and car wiring, including travel cable, will be replaced as necessary to fulfill the requirement of the new microprocessor controls. New duct to be provided.
Power Unit: New submersible power unit. The power unit replacement includes the motor, pump, hydraulic valve, muffler, oil reservoir tank, hydraulic fluid, isolation assembly and all necessary hardware. Elevator will be connected to County-owned generator during the course of the project.
Jack: Reuse existing jack. A new shutoff valve will be installed.
Oil: Removal and disposal of all existing oil in compliance with EPA standards.
Installation of new EPA-compliant oil.
Car Sling/Platform: Reuse existing. New toe guard to be provided.
Car Guides: Reuse existing.
Cab Interior: Reuse existing.
RFB 2026-38 Attachment 1 – Technical Specifications RFB 2026-38
Car Door Operation: Provide new closed loop door operation feature, designed to operate the car and hoistway doors simultaneously. Door movements will be electrically cushioned at both limits of travel.
Car Door Restrictors: Mechanical door restrictors will be provided in accordance with ASME A17.1/CSA B44-2025 Code.
Door Protection: Provide new electronic safety edge.
Hoistway Jamb Braille: Reuse existing to extent that it is ADA compatible.
Car Operating Panel: A new brushed stainless steel car operating panel will be provided accommodating all features provided by the microprocessor-based controls. The new car operating panel will be provided with new push buttons, ADA-compliant telephone, car position indicator, emergency lighting and Braille.
The existing two-year-old phone may be used, or a new phone may be installed if not compatible with the upgraded controls, to tie into to our emergency control system via SIP line (to be installed).
Car Arrival Lanterns: New car arrival lanterns with brushed stainless-steel finish will be provided.
Floor Passing Signal: An ADA-compliant audible signal will be provided to indicate to a passenger on the elevator that the elevator is stopping or passing a floor.
Alarm Bell: An emergency alarm bell will be connected to a plainly marked push button in the elevator operating panel and to the battery-operated emergency light device.
Hall Pushbuttons: New surface mounted fusion brushed stainless steel hall pushbutton fixtures will be installed at each landing. The new fixtures will include the fire exiting signs. The main egress floor will contain the fire service key switch and required language.
Hall Position Indicators & Lanterns: New brushed stainless steel fusion hall position indicators.
Pit Ladders/Pit Equipment: Reuse existing pit ladder. A new pit stop switch will be provided.