Revised Elevator Drawings Amendment 0002.pdf
PDF 4 MB Posted
- Solicitation number
- 36C255
About this file
This document package includes structural foundation plans, elevations, and details for the Relocate Community Living Center Project 589-335 in response to Solicitation Number 36C255 from the Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 15. The package provides architectural drawings showing the proposed building design, including foundation plans, sections, and elevations. It depicts the proposed building layout, structural elements, elevators, stairs, and other constructed features. Specifications for materials, reinforcement, and construction methods are noted. The solicitation seeks design and construction services to relocate the Community Living Center facility.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C25520R0021 0002.docx | DOCX document | |
| ATTENDANCE ROSTER Amendment 0002.xlsx | XLSX spreadsheet |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
2 4
EE
E.5
FF
G.5
K
N
P
P
/2
/1
/4
/4
9' - 0" 2' - 8"
9' - 8 1/2"
F12 C7
F11 C7 F7
F6
F9F8
F6
F5
F5
F6
F6
F5
F5
F7
TOF= -14' - 8"
2' - 0"
1.7
F8
S-301
F8 C4
48' - 2 3/4"
/1
/2
/4
S-500
VB-4
1' - 0 3/4" 20' - 9 3/4" 13' - 1 1/4" 3' - 1 3/4" 28' - 7" 13' - 6 15/16"
1' - 1"
1' - 0 3/4" 37' - 0 3/4" 28' - 7" 34' - 2 3/4" 1' - 9"
1' - 1"
77.562°
9' - 9 1/2"
FTG.
STEP
TOF= -15' - 6"
TOF= -11' - 8"
TOF= -9' - 0"
/4
S-300
S-300
S-300
10' - 0 5/16"
1' - 10 1/4"
11' - 9 9/16"
2' - 11 1/4"
26' - 7 5/8" 13' - 4" 9' - 4"
H
H.2
S-300
1' - 0 1/4" 20' - 0" 1' - 7 3/4"
/4
/4
/4
18' - 8 13/16" 18' - 2" 20' - 0"
11' - 6 1/4"
9' - 9 1/2" 1' - 0 1/4"
9 1/2"
1' - 10 1/2"
S-5005
V B
-5
/4
/2
TOF= -19' - 0"
TOF= -14' - 8"
F4F4 F4
F4
F4 F4
F4
F4 F4 F4
F4F4
TSL= -20' - 0"
TOF= -14' - 8"
F7F7F6
FTG.
STEP
F4
F4
S-300
P4 P1P8
P4
P1
P6
P2
P1 P1 P4
P6P2
P1
P1
P1
P1P1
P4
P1
P2 P1 P1
P3
P5
P2
P2
F4
F4
S-300
TOF= -15' - 8 1/128"
FTG HAUNCH
FTG HAUNCH
SEE 4/S300
TOF= -19' - 0"
P1
TOF= -15' - 6"
F T
G
S T
E P
/4
34' - 0" 4' - 1 1/2"
/4
/4
77.5 62°
M
J
/4
/2
TOC= -14' - 5"
TOC= -14' - 5"
TOC= -14' - 5"
TOC= -13' - 0"
TOC= -13' - 0"
11 3/4"
11"
1' - 6" 7' - 9" 8 1/4"
/4
9"9"
9" 8' - 5 5/16" 9" 8 7/8"
9"
9"8
9"
9"
TOF= -14' - 8"
TYP UNO
/4
/2
T U
N N
E L O
P E
N
IN
G x
/4
/4
F T
G
S T
E P
F T
G
S T
E P
TOF= -14' - 8"
S-301
S-301
8" 16' - 3"
2' - 0"
8" 2' - 0"
/4
8" 16' - 3"
2' - 0"
8"
2' - 0" 28' - 5 11/16"
21' - 10 3/16"
1' - 0"
3/4"
1' - 8" 17' - 6 3/4"
1' - 7" 9"
11' - 7 1/4"
9" 9"
7' - 9" 6' - 4" 16' - 1 3/4"
9" 9"
20' - 4 3/16"
9"
1' - 8"
31' - 8 5/8"
9" 9"
12' - 4 5/8"
1' - 10"
/4
/1
9" 9"
S-004
S-301
1' - 8"
S-302
1' - 8"
S-300
S-300
S-300
P4 P1 P1TOF= -14' - 8"
G
FTG.
STEP
S-302
/4
/4
1' - 4"
1' - 4"
S-302
S-302
S-302
S-302
S-301
S-301
S-301 TOC= -8' - 6"
TOC= -11' - 0"
TOC= -8' - 6"
TOC= -11' - 0"
F4
/2
3/8"
8' - 4"
1' - 0" 8"
1' - 0"
TOF= -16' - 6"
TOF= -17' - 6 1/128"
P1
/2
/2
/2
/2
/2
9 1/4"
1' - 0"
7 3/4"
S-300
S-300
S-300
S-300
S-301
S-300
S-300
S-300
S-300 TUNNEL - SEE CIVIL
& ARCH DWGS
TOF= -14' - 8"
TOF= -14' - 8"
S-301
SIM
CA
N.2
F5 P1
/4
/8
/2
S-004
1. SEE SHEET S-001 FOR GENERAL STRUCTURAL NOTES, INCLUDING MATERIAL
STRENGTHS.
2. SEE SHEET S-004 FOR CMU WALL REINFORCING SCHEDULES.
3. SEE SHEET S-003 FOR TYPICAL SLAB ON GRADE DETAILS.
4. SEE SHEET S-003 FOR TYPICAL FOUNDATION DETAILS.
5. REFER TO THE ARCHITECTURAL DRAWINGS AND/OR COORDINATE WITH
THE ARCHITECT REGARDING MISSING DIMENSIONS.
6. FINISHED FLOOR ELEVATION = -14’-0” UNLESS NOTED OTHERWISE. WHICH
CORRESPONDS TO AN ACTUAL ELEVATION OF 722'-0"
7. PROVIDE 6” NORMAL WEIGHT CONCRETE SLAB ON GRADE REINFORCED
WITH 6x6/W2.9 x W2.9 WWR PLACED IN UPPER THIRD OF SLAB.
8. PLACE SLAB ON 15 MIL. VAPOR BARRIER, OVER 4” MINIMUM CRUSHED &
COMPACTED ROCK. COMPACT TO 95% STANDARD PROCTOR.
9. SEE ARCHITECTURAL DRAWINGS FOR LOCATIONS OF RAMPS, DEPRESSED
SLABS, STEPPED SLABS, STOOPS AND NON-BEARING PARTITION WALLS.
10. PLACE ALL EXTERIOR STOOP SLABS OVER COMPACTED CLEAN GRANULAR
FILL MATERIAL PER TYPICAL DETAILS. DEPTH TO MATCH LOCAL FROST
REQUIREMENTS.
11. TOP OF EXTERIOR FOOTING ELEVATION -14’-8” UNLESS NOTED OTHERWISE
ON PLAN.
12. TOP OF INTERIOR FOOTING ELEVATION -14’-8” UNLESS NOTED OTHERWISE
ON PLAN.
13. COORDINATE TOP OF FOOTING ELEVATIONS WITH CROSSING
MECHANICAL PLUMBING LINE INVERTS AND ELECTRICAL LINE LOCATIONS.
STEP FOOTINGS DOWN ON EITHER SIDE OF LINE AND SLEEVE THROUGH
FOUNDATION WALLS.
14. ASSUMED TOP OF BEDROCK ELEVATION VARIES FROM EL 720'-0" ON THE EAST
END OF THE SITE TO 710'-0" ON THE WEST SIDE.
15. SEE ARCHITECTURAL & CIVIL DRAWINGS FOR FOUNDATION AND
UNDERSLAB DRAINAGE SYSTEM.
NOTE:
USE BASE PLATE TYPE LISTED IN THE COLUMN SCHEDULE UNLESS DIRECTED
OTHERWISE BY DETAIL REFERENCE OR SECTION CUT. (ESPECIALLY @ BRACE FRAMES)
SEE SHEET S-003 FOR BASE PLATE DETAILS
Engineering, Inc.
18207 Edison Avenue
Chesterfield, Missouri 63005
Phone: 636.530.7770 Fax: 636.530.7877
Missouri Certificate of Authority #NC 001244
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
BANCROFT ARCHITECTS + ENGINEERS Bancroft AE No.
700 Nicholas Blvd. Suite 300 Elk Grove Village, IL 60007
T:847.952.9362 www.bancroft-ae.com Department of Veterans Affairs
VA CONTRACT NO.
Revisions: Date
KEY PLAN:
N
18207 Edison Avenue Chesterfield, MO 63005 T (636) 530-7770 F (636) 530-7877 MO. Certificate of Authority #NC 001244
C U se r s
\d m e le n d e z\
D o cu m e n ts
\V A
C -C
L C
R
S
T R
U C
.2 .1 d m e le n d e zV
U P
A .r vt /2
/2
:5
:1
A
M
STRUCTURAL FOUNDATION BASEMENT
PLAN
16-123
HARRY S. TRUMAN VAMC
RELOCATE CLC
800 HOSPITAL DRIVE COLUMBIA, MO
02/28/18 MVV JMH
589-335
S-100
BID DOCUMENTS
VA255-16-C-0234
NORTH
SCALE: 1/8" = 1'-0"
STRUCTURAL FOUNDATION BASEMENT PLAN
STRUCTURAL COLUMN SCHEDULE
MARK SIZE BASE PL TYPE
C1 HSS6x6x5/16 BP-1
C2 HSS6x6x3/8 BP-1
C3 HSS6x6x1/2 BP-7
C4 HSS7x7x3/8 BP-3
C5 HSS7x7x1/2 BP-3
C6 HSS7x7x5/8 BP-3
C7 HSS8x8x5/8 BP-2
C8 HSS5X0.250 BP-4
C9 HSS4x4x5/16 BP-6
C11 HSS6x6x5/8 BP-1
C12 HSS8x8x3/8 BP-9
C13 HSS6x6x1/4 BP-1
STRUCTURAL FOOTING SCHEDULE
MARK SIZE REINFORCING
F4 4'-0"x4'-0"x1'-6" (6) #4 EA WAY BOT
F5 5'-0"x5'-0"x1'-6" (7) #5 EA WAY BOT
F6 6'-0"x6'-0"x1'-6" (9) #5 EA WAY BOT
F6A 6'-0"x6'-0"x1'-4" (6) #6 EA WAY TOP & BOT
F7 7'-0"x7'-0"x2'-0" (7) #6 EA WAY TOP & BOT
F8 8'-0"x8'-0"x2'-0" (10) #6 EA WAY TOP & BOT
F9 9'-0"x9'-0"x2'-0" (9) #7 EA WAY TOP & BOT
F10 10'-0"x10'-0"x2'-0" (9) #8 EA WAY TOP & BOT
F11 11'-0"x11'-0"x2'-3" (10) #8 EA WAY TOP & BOT
F12 12'-6"x12'-6"x2'-0" (10) #9 EA WAY TOP & BOT
F35-6 34'-9"x6'-0"x2'-0" (5) #9 TOP & BOT LONG, #5@9" OC TOP & BOT SHORT
F35-7 35'-3 1/4"x7'-0"x2'-0" (7) #9 TOP & BOT LONG, #6@12"OC TOP & BOT SHORT
F35-10 34'-9"x10'-0"x2'-0" (9) #9 TOP & BOT LONG, #6@10" OC TOP & BOT SHORT
FOUNDATION BASEMENT PLAN NOTES
STRUCTURAL PIER/PILASTER SCHEDULE
MARK SIZE REINFORCING
P1 18 x 18 PILASTER (4) #9 VERT & #3 TIES @ 12" OC + (3) #3 TIES IN TOP 5"
P2 20 x 18 PILASTER (4) #9 VERT & #3 TIES @ 12" OC + (3) #3 TIES IN TOP 5"
P3 21 x 18 PILASTER (8) #9 VERT & #3 TIES @ 12" OC + (3) #3 TIES IN TOP 5"
P4 28 x 18 PILASTER (10) #9 VERT & #3 TIES @ 12" OC + (3) #3 TIES IN TOP 5"
P5 22 x 22 PILASTER (8) #8 VERT & #3 TIES @ 12" OC + (3) #3 TIES IN TOP 5"
P6 20 x 21 PILASTER (4) #9 VERT & #3 TIES @ 12" OC + (3) #3 TIES IN TOP 5"
P8 24 x 18 PILASTER (4) #9 VERT & #3 TIES @ 12" OC + (3) #3 TIES IN TOP 5"
P9 24 x 24 PILASTER (8) #7 VERT & #3 TIES @ 10" OC + (3) #3 TIES IN TOP 5"
60% CD SUBMISSION 06/21/17
90% CD SUBMISSION 09/26/17
90% CD RE-SUBMISSION 12/01/17
100% CD SUBMISSION 01/10/18
BID DOCUMENTS 02/28/18
ADDENDUM 1 02/25/20
/2
PLAN
PER
BASEMENT
2" MIN
8 1/4"
5"
1"
6"
2' - 0"
#4 DOWELS @ 12" O.C.
4'-0"
2'-0"
(3)-#5 CONT.
C L A
S S
B
L A
P
#4 @ 12" O.C.
#6 @ 12" O.C.
#4 @ 16" O.C.
#4 @ 8" O.C.
DOWELS TO
MATCH VERT.
(1)-#4 x CONT.
CL
CONT WATERSTOP
6" LT GA STUD @ 16" OC PER SPECS
(MIN THICKNESS @ NORTH & WEST
EXTERIOR WALLS TO BE 68 MIL)
SEE GENERAL NOTES FOR WIND
PRESSURE ON THESE WALLS
PLAN
PER
8 1/4"
5"
1"
6"
(3)-#5 CONT.
2' - 0"
C L A
S S
B
L A
P
#4 DOWELS @ 12" O.C.
4'-0"
2'-0"
(1)-#4 x CONT.
#4 @ 12" O.C.
#6 @ 12" O.C.
#4 @ 16" O.C.
#4 @ 8" O.C.
CL
CONT WATERSTOP
6" LT GA STUD @ 16" OC PER SPECS
(MIN THICKNESS @ NORTH & WEST
EXTERIOR WALLS TO BE 68 MIL)
SEE GENERAL NOTES FOR WIND
PRESSURE ON THESE WALLS
9" 3"
BASEMENT
6" 6"
SEE TYPICAL EMBED PL
DETAILS ON SHT S-400
#6 @ 12" O.C.
#4 @ 12" O.C.
#4 @ 8" O.C.
#4 @ 16" O.C.
(3)-#5 CONT.
C L A
S S
B
L A
P
DOWELS TO
MATCH VERT.
#4 DOWELS @ 12" O.C.
4'-0"
2'-0"
#4 DOWELS @ 12" O.C.
4'-0"
2'-0"
(1)-#4 x CONT.
(1)-#4 x CONT.
E
CONT WATERSTOP
BRACE WALL UNTIL 7 DAYS
AFTER SLAB ON GRADE IS
POURED
2' - 0"
3/4"
BASEMENT
6" 6"
#6 @ 12" O.C.
#4 @ 12" O.C.
#4 @ 8" O.C.
#4 @ 16" O.C.
(3)-#5 CONT.
C L A
S S
B
L A
P
DOWELS TO
MATCH VERT.
(1)-#4 x CONT.(1)-#4 x CONT.
#4 DOWELS @ 12" O.C.
4'-0"
2'-0"
#4 DOWELS @ 12" O.C.
4'-0"
2'-0"
CL
2' - 0"
CONT WATERSTOP
BRACE WALL UNTIL 7
DAYS AFTER SLAB ON
GRADE IS POURED
0"
FIRST FLOOR
-14' - 0"
BASEMENT
S-300
8" 1' - 0" 8' - 4" 1' - 8" 8"
1' - 7 3/4"9' - 4 1/4"
1' - 8"
8' - 4"
3/8"
FTG HAUNCH BEYOND
SEE 4/S300
#5 @ 12" OC EA WAY
TOP & BOT
#4 @ 12" OC EA WAY
EA FACE - DWLS TO
MATCH
#4 CONT - TYP
.#5 @ 12"
#5 @ 8"
#8 @ 12"
#4 DWL @
12" OC - TYP
2'-0" 4'-0"
CONT WATERSTOP
FTG BEYOND
PER PLAN
L6x4x5/16 - CONT (LLV) w/ 3/4" Ø ANCH @ 24" OC
INTO FULLY GROUTED CELL
TYP UNO
CONT 12" CMU BOND BM
REINF w/ (2) #5 CONT
GROUT SOLID CONT
TYP @ FLOOR LEVEL
12" CMU WALL
REINF w/ #5 @ 24" OC
DWLS TO MATCH
GROUT SOLID @ ALL
REINF - TYP
12" CMU WALL
REINF w/ #5 @ 24" OC
DWLS TO MATCH
GROUT SOLID @ ALL
REINF - TYP
CONT WATERSTOP
0"
FIRST FLOOR
-14' - 0"
BASEMENT
8" 6 1/2"
6 1/2" 1' - 8" 11' - 0"
SEE TYPICAL EMBED PL
DETAILS ON SHT S-400
(3)-#5 CONT.
#4 @ 12" O.C.
#6 @ 12" O.C.
#4 @ 16" O.C.
#4 @ 8" O.C.
#4 @ 12" OC EA WAY
DWLS TO MATCH
#4 CONT - TYP
#4 DWL @ 12" OC - TYP
#4 CONT - TYP
#4 DOWELS @ 12" O.C.
4'-0"
2'-0"
REINF PIT SLAB PER
SECT 13/S-300
.#4 @ 12"
BRACE WALL UNTIL
14 DAYS AFTER ALL
WALLS ARE POURED
#5 @ 8"
#8 @ 12"
C L A
S S
B
L A
P
DOWELS TO
MATCH VERT.
CONT
WATERSTOP
G
2' - 0"
BRACE WALL
UNTIL 7 DAYS
AFTER SLAB
ON GRADE IS
POURED
SEE PLAN
6" LT GA STUD @
16" OC PER SPEC
12" CMU WALL
REINF w/ #5 @ 24" OC
DWLS TO MATCH
GROUT SOLID @ ALL
REINF - TYP
8" CMU WALL
REINF w/ #5 @ 24" OC
DWLS TO MATCH
GROUT SOLID @ ALL
REINF - TYP
CONT
WATERSTOP
CONT
WATERSTOP
PLAN
PER
BASEMENT
5"
1"
6"
2' - 0"
#4 DOWELS @ 12" O.C.
4'-0"
2'-0"
(3)-#5 CONT.
C L A
S S
B
L A
P
#4 @ 12" O.C.
#6 @ 12" O.C.
#4 @ 16" O.C.
#4 @ 8" O.C.
DOWELS TO
MATCH VERT.
(1)-#4 x CONT.
SEE TYPICAL EMBED PL
DETAILS ON SHT S-400
6" 1' - 0" 6"
CL
CONT WATERSTOP
BRACE WALL UNTIL 7
DAYS AFTER SLAB ON
GRADE IS POURED
6" LT GA STUD @
16" OC PER SPEC
PLAN
PER
BASEMENT
2' - 0"
#4 DOWELS @ 12" O.C.
4'-0"
2'-0"
(3)-#5 CONT.
C L A
S S
B
L A
P
#4 @ 12" O.C.
#6 @ 12" O.C.
#4 @ 16" O.C.
#4 @ 8" O.C.
DOWELS TO
MATCH VERT.
(1)-#4 x CONT.
SEE TYPICAL EMBED PL
DETAILS ON SHT S-400
6" 1' - 0" 6"
CL
CONT WATERSTOP
BRACE WALL UNTIL 7 DAYS
AFTER SLAB ON GRADE IS
POURED
0"
FIRST FLOOR
-14' - 0"
BASEMENT
S-300
11 3/8"1/4"8' - 4 3/8"11 5/8"
3/8"
/2
#5 @ 12" OC EA WAY
TOP & BOT
#4 CONT - TYP
T Y
P
C L A
S S
B
L A
P
#4 DWL @ 12" OC - TYP
#4 CONT - TYP
BRACE WALL UNTIL 7
DAYS AFTER SLAB ON
GRADE IS POURED
#5 @ 8"
#8 @ 12"
DOWELS TO
MATCH WALL
REINF. CONT WATERSTOP
.#5 @ 12"
L6x4x5/16 - CONT (LLV) w/ 3/4" Ø ANCH @ 24" OC
INTO FULLY GROUTED CELL
TYP UNO
CONT 12" CMU BOND BM
REINF w/ (2) #5 CONT
GROUT SOLID CONT
TYP @ FLOOR LEVEL
12" CMU WALL
REINF w/ #5 @ 24" OC
DWLS TO MATCH
GROUT SOLID @ ALL
REINF - TYP
#4 @ 12" OC EA WAY
EA FACE - DWLS TO
MATCH
8" 1' - 0" 8' - 4" 1' - 0" 1' - 4"
12" CMU WALL
REINF w/ #5 @ 24" OC
DWLS TO MATCH
GROUT SOLID @ ALL
REINF - TYP
CHAMFER SLAB EDGE
CONT WATERSTOP
#4 DWL @
12" OC - TYP
2'-0" 4'-0"
SEE SHEETSEE DETAIL
14 S-004
#9 VERT
#4 TIE @ 12"
WALL REINF PER
SECTION
SEE PLAN
WALL 1' - 0"
FTG HAUNCH
SEE PLAN
Engineering, Inc.
18207 Edison Avenue
Chesterfield, Missouri 63005
Phone: 636.530.7770 Fax: 636.530.7877
Missouri Certificate of Authority #NC 001244
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
BANCROFT ARCHITECTS + ENGINEERS Bancroft AE No.
700 Nicholas Blvd. Suite 300 Elk Grove Village, IL 60007
T:847.952.9362 www.bancroft-ae.com Department of Veterans Affairs
VA CONTRACT NO.
Revisions: Date
KEY PLAN:
N
18207 Edison Avenue Chesterfield, MO 63005 T (636) 530-7770 F (636) 530-7877 MO. Certificate of Authority #NC 001244
C U se r s
\d m e le n d e z\
D o cu m e n ts
\V A
C -C
L C
R
S
T R
U C
.2 .1 d m e le n d e zV
U P
A .r vt /2
/2
:5
:1
A
M
STRUCTURAL FOUNDATION SECTIONS
16-123
HARRY S. TRUMAN VAMC
RELOCATE CLC
800 HOSPITAL DRIVE COLUMBIA, MO
02/28/18 MVV JMH
589-335
S-300
BID DOCUMENTS
VA255-16-C-0234
SCALE: 1/2" = 1'-0"1
FOUNDATION SECTION
SCALE: 1/2" = 1'-0"3
FOUNDATION SECTION
SCALE: 1/2" = 1'-0"5
FOUNDATION SECTION
SCALE: 1/2" = 1'-0"7
FOUNDATION SECTION
SCALE: 1/2" = 1'-0"13
FOUNDATION SECTION
SCALE: 1/2" = 1'-0"15
FOUNDATION SECTION
SCALE: 1/2" = 1'-0"23
FOUNDATION SECTION
SCALE: 1/2" = 1'-0"19
FOUNDATION SECTION
SCALE: 1/2" = 1'-0"21
FOUNDATION SECTION
SCALE: 1/2" = 1'-0"4
TYPICAL FOOTING HAUNCH DETAIL
60% CD SUBMISSION 06/21/17
90% CD SUBMISSION 09/26/17
90% CD RE-SUBMISSION 12/01/17
100% CD SUBMISSION 01/10/18
BID DOCUMENTS 02/28/18
FIRST FLOOR
0"
BASEMENT FLOOR
-14' - 0"
BOTTOM OF FOOTING 2
-15' - 8"
A-300
TOP OF METAL DECK 2
19' - 6"
TOP OF COPING
16' - 2 3/4"
A-301
1.7 1.5 13A-610
F
C
D
A
E
B
E
B
E
B
D
A
D
A
3 4
62 88
A-301
9 2
4 5
E
B
A-432
10111213
T/ CONCRETE DECK
14' - 6 1/2"
FIRST FLOOR
0"
BASEMENT FLOOR
-14' - 0"
BOTTOM OF FOOTING 2
-15' - 8"
A-300
BOTTOM OF FOOTING 1
-5' - 0"
TOP OF METAL DECK 2
19' - 6"
TOP OF COPING
16' - 2 3/4"
A-301
A-301
T/ ELEVATOR PIT
-20' - 0"
1.71.5
B/ OF ELEV. OVER-RUN
13' - 0"
1 3
A-612
A-612
A-612
A-610
4 4
8 88 9
2 4
7 4
6 2
3 110
4 66
H K L
10 11 12 13
T/ CONCRETE DECK
14' - 6 1/2"
ELEVATION GENERAL NOTES
1. FOOTINGS ARE SHOWN FOR REFERENCE ONLY - REFER
TO STRUCTURAL DRAWINGS FOR EXACT DIMENSIONS
AND LOCATIONS.
ELEVATION KEY NOTES
1. FOUNDATIONS - REFER TO STRUCTURAL
2. CAST STONE
3. FACE BRICK
4. GLAZING - REFER TO A-610 FOR GLAZING SCHEDULE AND
CURTAIN WALL ELEVATIONS AND STOREFRONT TYPES.
5. CONCRETE FOUNDATION WALL - STAINED TO MATCH
CAST STONE FINISH.
6. PREFINISHED COLOR-COATED ALUMINUM COPING
7. BOLLARD - REFER TO DETAIL ( )
8. SECURITY CAMERA - REFER TO ELECTRICAL
9. EXTERIOR WALL MOUNTED LIGHT FIXTURE - REFER
TO ELECTRICAL
10. HOSE BIB LOCATION - REFER TO PLUMBING DRAWINGS.
11. VACUUM EXHAUST - REFER TO SHEETS MG-101 & MG-102
12. EXTERIOR BUILDING SIGNAGE - REFER TO DETAIL ( )
13. CONTROL JOINT
/1 AS-100
/1 I-312
FIRST FLOOR
0"
BASEMENT FLOOR
-14' - 0"
BOTTOM OF FOOTING 2
-15' - 8"
A-301
TOP OF METAL DECK 2
19' - 6"
TOP OF COPING
16' - 2 3/4"
T/ ELEVATOR PIT
-20' - 0"
6.2
B/ OF ELEV. OVER-RUN
13' - 0"
A-611
T/ OF CONC. RETAINING
WALL
-8' - 6"
4 4
8 88 9
7 4
6 2
3 110
4 668
H K L
8 9
T/ CONCRETE DECK
14' - 6 1/2"
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
BANCROFT ARCHITECTS + ENGINEERS Bancroft AE No.
700 Nicholas Blvd. Suite 300 Elk Grove Village, IL 60007
T:847.952.9362 www.bancroft-ae.com Department of Veterans Affairs
VA CONTRACT NO.
Revisions: Date
KEY PLAN:
N
C :\U se r s
\d m el en de z\
D o c um en ts \5
-3
3 5 C ol um bi a
V A
M C
C
E N
T R
A L)
0_ dm el en de zV
U P
A 5.
rv t
2/
/2 0 2
:0 3:
P
M
EXTERIOR ELEVATIONS
16-123
HARRY S. TRUMAN VAMC
RELOCATE CLC
800 HOSPITAL DRIVE COLUMBIA, MO
05/11/2018 DM CR II EM
589-335
A-200
BID DOCUMENTS
VA255-16-C-0234
1/8" = 1'-0"
NORTH ELEVATION
1/8" = 1'-0" 2A
SOUTH ELEVATION - A
1/8" = 1'-0" 2B
SOUTH ELEVATION - B
4'0 8' 16'
4'0 8' 16'
4'0 8' 16'
BID DOCUMENTS 05/11/18
BASEMENT FLOOR
-14' - 0"
D E F J
BOTTOM OF FOOTING 2
-15' - 8"
A-300
TOP OF METAL DECK 2
19' - 6"
TOP OF COPING
16' - 2 3/4"
A-500
C
A-430
K NB
A-611
T/ OF CONC. RETAINING
WALL
-8' - 6"
T/ OF INTERMEDIATE
LANDING
-7' - 0"
D
A
D
A
E
B
D
A
E
B
D
A
E
B
D
A
8 9 6 3 2 4 486
G
G H
T/ CONCRETE DECK
14' - 6 1/2"
FIRST FLOOR
0"
BASEMENT FLOOR
-14' - 0"
BOTTOM OF FOOTING 2
-15' - 8"
BOTTOM OF FOOTING 1
-5' - 0"
A-500
A-411
TOP OF METAL DECK 2
19' - 6"
TOP OF COPING
16' - 2 3/4"
P
A-410A-610
A-611
A-411A-611
6 3 2
4 44 3 2 9
J
T/ CONCRETE DECK
14' - 6 1/2"
ELEVATION GENERAL NOTES
1. FOOTINGS ARE SHOWN FOR REFERENCE ONLY - REFER
TO STRUCTURAL DRAWINGS FOR EXACT DIMENSIONS
AND LOCATIONS.
ELEVATION KEY NOTES
1. FOUNDATIONS - REFER TO STRUCTURAL
2. CAST STONE
3. FACE BRICK
4. GLAZING - REFER TO A-610 FOR GLAZING SCHEDULE AND
CURTAIN WALL ELEVATIONS AND STOREFRONT TYPES.
5. CONCRETE FOUNDATION WALL - STAINED TO MATCH
CAST STONE FINISH.
6. PREFINISHED COLOR-COATED ALUMINUM COPING
7. BOLLARD - REFER TO DETAIL ( )
8. SECURITY CAMERA - REFER TO ELECTRICAL
9. EXTERIOR WALL MOUNTED LIGHT FIXTURE - REFER
TO ELECTRICAL
10. HOSE BIB LOCATION - REFER TO PLUMBING DRAWINGS.
11. VACUUM EXHAUST - REFER TO SHEETS MG-101 & MG-102
12. EXTERIOR BUILDING SIGNAGE - REFER TO DETAIL ( )
13. CONTROL JOINT
/1 AS-100
/1 I-312
FIRST FLOOR
0"
BASEMENT FLOOR
-14' - 0"
DEFJM B.9D.4E.5
BOTTOM OF FOOTING 2
-15' - 8"
A-300
BOTTOM OF FOOTING 1
-5' - 0"
TOP OF METAL DECK 2
19' - 6"
AB.1
TOP OF COPING
16' - 2 3/4"
H.2
T/ ELEVATOR PIT
-20' - 0"
CK
B/ OF ELEV. OVER-RUN
13' - 0"
N B
6 3 2
4 6 44 3 2 9
J
G
H G.5
T/ CONCRETE DECK
14' - 6 1/2"
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
BANCROFT ARCHITECTS + ENGINEERS Bancroft AE No.
700 Nicholas Blvd. Suite 300 Elk Grove Village, IL 60007
T:847.952.9362 www.bancroft-ae.com Department of Veterans Affairs
VA CONTRACT NO.
Revisions: Date
KEY PLAN:
N
C :\U se r s
\d m el en de z\
D o c um en ts \5
-3
3 5 C ol um bi a
V A
M C
C
E N
T R
A L)
0_ dm el en de zV
U P
A 5.
rv t
2/
/2 0 2
:0 3:
P
M
EXTERIOR ELEVATIONS
16-123
HARRY S. TRUMAN VAMC
RELOCATE CLC
800 HOSPITAL DRIVE COLUMBIA, MO
05/11/2018 DM CR II EM
589-335
A-201
BID DOCUMENTS
VA255-16-C-0234
1/8" = 1'-0"
WEST ELEVATION
1/8" = 1'-0" 4B
EAST ELEVATION - B
1/8" = 1'-0" 4A
EAST ELEVATION - A
4'0 8' 16'
4'0 8' 16'
4'0 8' 16'
BID DOCUMENTS 05/11/18
BASEMENT FLOOR
-14' - 0"
B/ OF FOOTING 2
-15' - 8"
FIRST FLOOR
0' - 0"
T/ OF METAL DECK
13' - 8 1/2"
T/ METAL DECK 2
19' - 6"
T/ COPING
16' - 2 3/4"
41.71.5 51 32
FIRST FLOOR
0"
BASEMENT FLOOR
-14' - 0"
BOTTOM OF FOOTING 2
-15' - 8"
TOP OF METAL DECK 2
19' - 6"
A-301
T/ ELEVATOR PIT
-20' - 0"
B/ OF ELEV. OVER-RUN
13' - 0"
A-612
63 9 2
2 4
A-301
A-432
10111213
T/ CONCRETE DECK
14' - 6 1/2"
ELEVATION GENERAL NOTES
1. FOOTINGS ARE SHOWN FOR REFERENCE ONLY - REFER
TO STRUCTURAL DRAWINGS FOR EXACT DIMENSIONS
AND LOCATIONS.
ELEVATION KEY NOTES
1. FOUNDATIONS - REFER TO STRUCTURAL
2. CAST STONE
3. FACE BRICK
4. GLAZING - REFER TO A-610 FOR GLAZING SCHEDULE AND
CURTAIN WALL ELEVATIONS AND STOREFRONT TYPES.
5. CONCRETE FOUNDATION WALL - STAINED TO MATCH
CAST STONE FINISH.
6. PREFINISHED COLOR-COATED ALUMINUM COPING
7. BOLLARD - REFER TO DETAIL ( )
8. SECURITY CAMERA - REFER TO ELECTRICAL
9. EXTERIOR WALL MOUNTED LIGHT FIXTURE - REFER
TO ELECTRICAL
10. HOSE BIB LOCATION - REFER TO PLUMBING DRAWINGS.
11. VACUUM EXHAUST - REFER TO SHEETS MG-101 & MG-102
12. EXTERIOR BUILDING SIGNAGE - REFER TO DETAIL ( )
13. CONTROL JOINT
/1 AS-100
/1 I-312
EFIS WALL FINISH
8 88 9 4
A-202
5/8" PRESSURE TREATED
PLYWOOD SHEATHING
2" EXPANDED
POLYSTYRENE
INSULATION BOARD
ADHERED TO SHEATHING
REINFORCING MESH
EMBEDDED IN BASECOAT
FINISH COAT
AIR/WATER BARRIER
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
BANCROFT ARCHITECTS + ENGINEERS Bancroft AE No.
700 Nicholas Blvd. Suite 300 Elk Grove Village, IL 60007
T:847.952.9362 www.bancroft-ae.com Department of Veterans Affairs
VA CONTRACT NO.
Revisions: Date
KEY PLAN:
N
C :\U se r s
\d m el en de z\
D o c um en ts \5
-3
3 5 C ol um bi a
V A
M C
C
E N
T R
A L)
0_ dm el en de zV
U P
A 5.
rv t
2/
/2 0 2
:0 3:
P
M
BUILDING ELEVATIONS BID ITEM 5 AND
16-123
HARRY S. TRUMAN VAMC
RELOCATE CLC
800 HOSPITAL DRIVE COLUMBIA, MO
05/11/2018 DM CR II EM
589-335
A-202
BID DOCUMENTS
VA255-16-C-0234
1/8" = 1'-0"
PARTIAL NORTH ELEVATION
4'0 8' 16'
1/8" = 1'-0"
SOUTH ELEVATION - BID ITEM 5 AND 8
4'0 8' 16'
BID DOCUMENTS 05/11/18
ADDENDUM 1 02/25/20
3/4" = 1'-0"
BID ITEM 8 - WALL SECTION
0 1' 2' 3'
BASEMENT FLOOR
-14' - 0"
BOTTOM OF FOOTING 2
-15' - 8"
BOTTOM OF FOOTING 1
-5' - 0"
A-411
TOP OF METAL DECK 2
19' - 6"
TOP OF COPING
16' - 2 3/4"
B/ OF ELEV. OVER-RUN
13' - 0"
P 9
A-4103
A-411
VACUUM EXHAUST - REFER
TO SHEETS MG-101 & MG-102
I-312
CORRIDOR
C0K03
GALLERIA
C1K06
VESTIBULE
K100B
VESTIBULE
K100A
T/ CONCRETE DECK
14' - 6 1/2"
FIRST FLOOR
0"
BASEMENT FLOOR
-14' - 0"
F
BOTTOM OF FOOTING 2
-15' - 8"
BOTTOM OF FOOTING 1
-5' - 0"
H.2 K
B/ OF ELEV. OVER-RUN
13' - 0"
G HG.5
T/ CONCRETE DECK
14' - 6 1/2"
FIRST FLOOR
0"
BASEMENT FLOOR
-14' - 0"
BOTTOM OF FOOTING 2
-15' - 8"
T/ ELEVATOR PIT
-20' - 0"
K
B/ OF ELEV. OVER-RUN
13' - 0"
A-302
T/ OF INTERMEDIATE
LANDING
-7' - 0"
G HG.5
T/ CONCRETE DECK
14' - 6 1/2"
FIRST FLOOR
0"
BASEMENT FLOOR
-14' - 0"
BOTTOM OF FOOTING 2
-15' - 8"
T/ ELEVATOR PIT
-20' - 0"
B/ OF ELEV. OVER-RUN
13' - 0"
A-302
G HG.5
T/ CONCRETE DECK
14' - 6 1/2"
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
BANCROFT ARCHITECTS + ENGINEERS Bancroft AE No.
700 Nicholas Blvd. Suite 300 Elk Grove Village, IL 60007
T:847.952.9362 www.bancroft-ae.com Department of Veterans Affairs
VA CONTRACT NO.
Revisions: Date
KEY PLAN:
N
C :\U se r s
\d m el en de z\
D o c um en ts \5
-3
3 5 C ol um bi a
V A
M C
C
E N
T R
A L)
0_ dm el en de zV
U P
A 5.
rv t
2/
/2 0 2
:0 3:
P
M
BUILDING SECTIONS
16-123
HARRY S. TRUMAN VAMC
RELOCATE CLC
800 HOSPITAL DRIVE COLUMBIA, MO
05/11/2018 DM CR II EM
589-335
A-301
BID DOCUMENTS
VA255-16-C-0234
1/8" = 1'-0"
BUILDING SECTION 3
1/4" = 1'-0"
BUILDING SECTION AT LINK CORRIDOR
1/4" = 1'-0"
BUILDING SECTION AT STAIR
1/4" = 1'-0"
BUILDING SECTION AT ELEVATOR
4'0 8' 16'
0 2' 4' 8' 0 2' 4' 8' 0 2' 4' 8'
BID DOCUMENTS 05/11/18
BASEMENT FLOOR
-14' - 0"
BOTTOM OF FOOTING 2
-15' - 8"
BOTTOM OF FOOTING 1
-5' - 0"
T/ ELEVATOR PIT
-20' - 0"
B/ OF ELEV. OVER-RUN
13' - 0"
G HG.5
T/ CONCRETE DECK
14' - 6 1/2"
FIRST FLOOR
0"
BASEMENT FLOOR
-14' - 0"
BOTTOM OF FOOTING 2
-15' - 8"
BOTTOM OF FOOTING 1
-5' - 0"
T/ OF INTERMEDIATE
LANDING
-7' - 0"
R
IS
E
R S
R
IS
E
R S
G H
0" 15' - 5"
CONCRETE FILLED
METAL
PAN LANDING
2" CONCRETE FILLED PAN
TREAD W/ VINYL STAIR TREAD
(TD-1)
STEEL ANGLE WITH SLOTTED
BOLT CONNECTION
STEEL HEADER CHANNEL
STEEL ANGLE
TREAD SUPPORT
T/O INTERMEDIATE
LANDING
-7' - 0"
BASEMENT FLOOR
-14' - 0"
CONCRETE SLAB FLOOR. SEE
STRUCTURAL DRAWINGS.
STRUCTURAL STEEL CLIP ANGLE. WELD
TO STRINGER AND BOLT TO FLOOR WITH
EXPANSION BOLT.
STEEL STRINGER WITH
CLOSURE PLATE.
2" CONCRETE FILLED
PAN TREAD W/ VINYL
STAIR TREAD (TD-1)
PREFORMED RISER AND
NOSING. WELD TO STRINGER.
1 1/2" DIAMETER STEEL PIPE
CONTINUOUS HAND RAIL.
3/4" STEEL TUBE BALUSTERS
AT 4 3/4" OC (TYPICAL).
1 1/2" DIAMETER STEEL PIPE
NEWEL.
T/ OF INTERMEDIATE
LANDING
-7' - 0"
FACE OF CONCRETE
FOUNDATION WALL
CONCRETE FILLED
METAL PAN LANDING.
STEEL CHANNEL STRINGER.
BEAR 4" INTO CONC. WALL.
(SEE STRUCT. DWGS.)
STEEL SUPPORT ANGLE
(SEE STRUCT. DWGS.)
HANDRAIL SHALL
TRANSITION TO
LEVEL HEIGHT
REQUIRED AT ALL
LANDINGS
TYPICAL HANDRAIL
BRACKET ANCHORED
TO WALL
1 1/2" DIAMETER STEEL
PIPE HANDRAIL. RETURN
ENDS TO WALL.
1 1/2" CLEAR
1' - 0"
1' - 0"
4 '- 0" MAX.
1' - 0"
1' - 11"
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
BANCROFT ARCHITECTS + ENGINEERS Bancroft AE No.
700 Nicholas Blvd. Suite 300 Elk Grove Village, IL 60007
T:847.952.9362 www.bancroft-ae.com Department of Veterans Affairs
VA CONTRACT NO.
Revisions: Date
KEY PLAN:
N
C :\U se r s
\d m el en de z\
D o c um en ts \5
-3
3 5 C ol um bi a
V A
M C
C
E N
T R
A L)
0_ dm el en de zV
U P
A 5.
rv t
2/
/2 0 2
:0 8:
P
M
STAIR AND ELEVATOR DETAILS
16-123
HARRY S. TRUMAN VAMC
RELOCATE CLC
800 HOSPITAL DRIVE COLUMBIA, MO
05/11/2018 DM CR II EM
589-335
A-302
BID DOCUMENTS
VA255-16-C-0234
1/2" = 1'-0"
SECTION AT ELEVATOR
1/2" = 1'-0"
SECTION AT STAIR
1 1/2" = 1'-0"
STAIR DETAIL SECTION
1 1/2" = 1'-0"
SECTION AT STAIR DETAIL 2
1 1/2" = 1'-0"
SECTION AT STAIR LANDING
NOT TO SCALE
WALL MOUNTED HANDRAIL AT STAIR
0 1' 2' 4'
0 1' 2'
0 1' 2' 4'
0 1' 2'
0 1' 2'
BID DOCUMENTS 05/11/18
| S-100 - STRUCTURAL FOUNDATION BASEMENT PLAN.pdf (p.1) |
| S-300 - STRUCTURAL FOUNDATION SECTIONS.pdf (p.2) |
| A-200-A302.pdf (p.3-7) |
File details come from the government source that posted it. Updated .