Required_Specifications_1.pdf

PDF 125 KB Posted

Attached to
infrasound acoustic monitors
Solicitation number
140G0326Q0153
Issued by

About this file

This is a Technical Specifications document for infrasound acoustic monitoring sensors required by the USGS Volcano Science Center for volcano monitoring purposes. All sensors must be delivered by September 30, 2026, and must be existing products currently in production with an established performance history; units modified or developed solely to meet these requirements are not acceptable.

The sensors must meet strict calibration and performance standards, with individual calibration within ±5% of nominal values traceable to a nationally accredited external laboratory. Signal characteristics require nominal sensitivity of 0.0275V/Pa@1Hz or greater and a full scale range of 720Pa peak-to-peak or greater, with differential output type and maximum signal output of 20VPP. Operational specifications include frequency response flat to within ±3dB from 0.02Hz to 240Hz or wider, band-limited self-noise of 5mPa RMS from 0.05 to 200Hz or less, and dynamic range of 110dB or greater. Power requirements specify a DC supply range of 11.5V to 18V or wider with reverse polarity protection and current consumption of 150mW or less. Physical characteristics limit sensors to 4 inches diameter or smaller and 3.5 inches tall or shorter, with minimum three acoustic entry points, operating temperature range of -40°C to +65°C, humidity tolerance of 90% or greater, and housing constructed of corrosion-resistant materials isolated from ground.

View the file

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Technical Specifications for Acoustic Monitoring Sensor

The USGS Volcano Science Center (VSC) requires infrasound acoustic monitors for the purposes of volcano monitoring. These sensors must meet the following specifications:

Deliver:

• Must be delivered by September 30, 2026

General:

- Individual sensor calibration must be within +-5% of acceptable nominal values

- Nominal calibration values must be traceable to a nationally accredited external laboratory calibration chamber and shown to meet requirements

- Sensor must be in current production and have an established, proven, and acceptable performance history o This acquisition is directed at existing products only, not at product design and development o Units that have been modified or developed solely to meet the requirements of this acquisition are not acceptable

Signal Characteristics:

- Nominal Sensitivity: .0275V/Pa@1Hz or greater

- Full Scale Range: 720Pa peak to peak full scale input range or greater

Sensor Output Specifications:

- Output type: Differential

- Maximum signal output: 20VPP

Operational frequency band and self-noise

- Frequency response: Flat to within +-3dB from .02Hz to 240Hz or wider band

- Band-limited Self Noise: 5mPa RMS from 0.05 to 200Hz or less

- Dynamic Range: 110dB or greater

Power requirements:

- DC supply range: 11.5V to 18V or wider with reverse polarity protection

- DC current consumption: 150mW or less

Physical Characteristics:

- 4” diameter or smaller

- 3.5” tall or shorter

- Acoustic entry points: minimum of three

- Operating temperature: -40C to +65C

- Humidity tolerance: 90% or greater immunity to humidity

- Housing must be of corrosion resistant material(s) that are isolated from ground.