Request_for_Quotes_(Sunset_Park_-_Replacing_Powerlines_-_Main_Service_to_Field_#1).pdf
PDF 326 KB Posted
- Solicitation number
- 2027-12QQ
- Issued by
- Fort Bend County, Texas
About this file
This is a Request for Quotations issued by the City of Rosenberg, Texas, for electrical infrastructure work at Sunset Park. The project involves replacing overhead powerlines from the main service to field #1, including removal of overhead electrical wiring, three telephone poles, and one pole anchor bolt; saw cutting the driveway for trench access; trenching and installing pipe and wire over approximately 450 feet; rewiring three area lights; and energizing and testing the new wiring system. The scope requires all labor, materials, equipment, permits, and inspections to be included in vendor proposals. The quotation was released on October 12, 2026, with a response deadline of October 23, 2026, at 3:00 pm. Responses must be submitted electronically through the City's procurement portal at https://procurement.opengov.com/portal/rosenbergtx. The project is located at Sunset Park, 2017 Mulcahy Street, Rosenberg, Texas 77471, and involves a 208-3 phase, 200-amp service upgrade.
This is not a formal solicitation, and the City of Rosenberg has indicated that a contract may or may not be formed from this request. If a formal solicitation becomes necessary, vendors will be notified. Vendors submitting quotes must certify they have reviewed the Request for Quotations and are authorized to submit on behalf of their organization. The project contact is Cary Lamensky, Director of Parks and Recreation, and the procurement contact is Blake Skiles, Procurement Manager. No specific pricing terms, set-asides, or funding source information is provided in this quotation document.
View the file
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
REQUEST FOR QUOTATIONS
Solicitation #2027-12QQ
REQUEST FOR QUOTES (SUNSET PARK - REPLACING
POWERLINES - MAIN SERVICE TO FIELD #1)
City of Rosenberg
2110 4th Street
Rosenberg, TX 77471
RELEASE DATE: October 12, 2026
DEADLINE FOR QUESTIONS: undefined
RESPONSE DEADLINE: October 23, 2026, 3:00 pm
RESPONSES MUST BE SUBMITTED ELECTRONICALLY TO:
https://procurement.opengov.com/portal/rosenbergtx https://procurement.opengov.com/portal/rosenbergtx
City of Rosenberg
REQUEST FOR QUOTATIONS
Request for Quotes (Sunset Park - Replacing Powerlines - Main Service to Field #1)
I. Introduction II. Request for Quotes
III. Vendor Questionnaire
Request For Quotations #2027-12QQ Title: Request for Quotes (Sunset Park - Replacing Powerlines - Main Service to Field #1)
1. Introduction
1.1. Summary
The City of Rosenberg is seeking quotes from qualified vendors for Sunset Park - Replacing Powerlines -
Main Service to Field #1. This should include all labor, materials, equipment, permits, and inspections.
1.2. Background
Please note this is not a formal solicitation. A contract may or may not be formed from this request. If a formal solicitation is deemed necessary, vendors will be notified.
1.3. Contact Information
Project Contact:
Cary Lamensky
Director of Parks and Recreation
Email: clamensky@rosenbergtx.gov
Phone: (832) 595-3962
Procurement Contact:
Blake Skiles
Procurement Manager
Email: tskiles@rosenbergtx.gov
Phone: (832) 595-3363
Department:
Parks
1.4. Timeline
Release Request Date October 12, 2026
Quote Submission Deadline October 23, 2026, 3:00pm mailto:clamensky@rosenbergtx.gov tel:(832)595-3962 mailto:tskiles@rosenbergtx.gov tel:(832)595-3363
2. Request for Quotes
2.1. Requirements
Sunset Park
2017 Mulcahy Street
Rosenberg, TX 77471
Replacing power lines from main service to field #1
208- 3 phase 200 amp
Proposal shall include all labor, materials, equipment, permits, and inspection.
1. Remove the overhead electrical wiring between the main service and the electrical box for field#1.
2. Remove 3 telephone poles supporting the wires to be removed.
3. Remove one pole anchor bolt.
4. Saw cut driveway for access to trench.
5. Trench and install pipe and wire between the main service and the electrical box for field #1.
(appox. 450 ft.)
6. Rewire 3 area lights that will lose power when removing overhead wiring.
7. Energize and test new wiring system.
3. Vendor Questionnaire
3.1. Are you submitting a quote?*
☐ Yes
☐ No
*Response required
When equals "Yes"
3.1.1. Certification*
Vendor certifies they have read this Request for Quotes, viewed any Exhibits (if applicable), and are authorized to submit this quote on behalf of their organization.
Vendor further understands this is not a formal solicitation. A contract may or may not be formed from this request. If a formal solicitation is deemed necessary, vendors will be notified.
☐ Yes
☐ No
*Response required
When equals "Yes"
3.1.2. Quote Document*
Please upload your quote here.
*Response required
When equals "No"
3.1.3. No Bid Comment
Please let us know why you are submitting a no bid.
| 1. Introduction |
| 1.1. Summary |
| 1.2. Background |
| 1.3. Contact Information |
| 1.4. Timeline |
| 2. Request for Quotes |
| 2.1. Requirements |
| 3. Vendor Questionnaire |
| 3.1. Are you submitting a quote?* |
| 3.1.1. Certification* |
| 3.1.2. Quote Document* |
| 3.1.3. No Bid Comment |
File details come from the government source that posted it. Updated .