About this file

This document is a Request for Information (RFI) issued by the Department of the Air Force Materiel Command Test Center for painting and epoxy coating installation services for the Anechoic Chamber Floor in Building 1030 at Edwards Air Force Base, California.

The key requirements include preparing the concrete and metal floor areas, installing an epoxy coating resistant to chemicals, painting grid lines, grid coordinate numbers, degree markings, and other elements according to a specific color scheme. Optional bid items include joint filling. The government will provide and install the required stencils, and the contractor will be responsible for painting the stenciled areas. The period of performance is 30 days after award. The government is seeking information from interested offerors, including company details, experience, business size, socioeconomic status, and any other relevant information. Responses are due by April 26, 2024 at 2:30pm PDT and should be submitted via email to the identified Contracting Officer and Contract Specialist.

View the file

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

REQUEST FOR INFORMATION (RFI) – PAINTING ANECHOIC CHAMBER FLOOR

BUILDING 1030

THIS IS A MARKET SURVEY FOR INFORMATION ONLY. THIS IS NOT A

SOLICITATION FOR PROPOSALS AND NO CONTRACT WILL BE AWARDED

FROM THIS SYNOPISIS. NO REIMBURSEMENT WILL BE MADE FOR ANY COSTS

ASSOCIATED WITH PROVIDING INFORMATION IN RESPONSE TO THIS

SYNOPSIS OR ANY FOLLOW-UP INFORMATION REQUESTS. THE PURPOSE OF

THIS SYNOPSIS IS TO GAIN KNOWLEDGE OF POTENTIALLY QUALIFIED

SOURCES AND THEIR SIZE CLASSIFICATIONS (SMALL BUSINESS, LARGE

BUSINESS, ETC.). PLEASE DO NOT REQUEST A COPY OF A SOLICITATION, AS

ONE DOES NOT EXIST.

- REQUIREMENTS –

Requirement for Painting and Epoxy Coating installation for the Anechoic Chamber Floor Building 1030.

The objective of this requirement is to secure the services of a qualified contractor to install an epoxy coating on a portion of the concrete and metal floor areas in Building 1030, Edwards Air Force Base (EAFB), California. The proposed epoxy coating shall be resistant to chemicals and be designed for use in an aircraft hangar environment. In addition to floor painting, optional bid items will include grid lines, grid coordinate painting, and joint filling. All grids will be painted on the floor to form an accurate (tolerance for grid is ¼” in 80’). The tolerance for the 360-degree markings are to be within 1/10th of a degree. The government will perform the layout work, provide, and install all required stencils. The contractor will be required to paint the stenciled areas and the degree marks.

• Prepare the areas to receive coating in accordance with the manufacturer’s recommendations, then coat the steel turntable and concrete area of the chamber known as the “hardback” in white, paint the tow-line in black, yellow, black, paint the perpendicular center line in black, yellow, black, paint the degree marks at 5 degree intervals in red and between the 5 degree intervals in black, static grounds in yellow, paint the egress door in black and yellow stripes, and all plate stenciling in ½” tall letters.

Note: The government will provide and install the stencils, the contractor shall paint. See drawings for a complete description of the required color scheme.

Turntable

• -The contractor shall paint a grid system on the turntable. The grid system shall be yellow

4-ft by 4-ft and correspond with the existing grid system. The yellow grid lines shall be (½-inch wide). See drawings for details on grid system.

• -Paint the grid coordinate numbers in each position as shown on the drawings. Grid coordinate lettering shall be 1” tall yellow.

• -The contractor shall prepare the concrete floor by filling the existing grid lines which are approximately 1/8” wide by ¼” deep saw cuts in the concrete. The filler material shall be compatible with the proposed coating and flush with the existing floor.

Hardback

• -The contractor shall paint a grid system on the concrete hardback area. The grid system shall be yellow 4-ft by 4-ft and correspond with the existing grid system. The yellow grid lines shall be (½-inch wide). See drawings for details on grid system.

• -Paint the grid coordinate numbers in each position as shown on the drawings. Grid coordinate lettering shall be 1” tall yellow.

• -Paint the plates in accordance with the color scheme shown on the drawings. Note: paint only the tops of plates, care shall be taken to avoid painting the edges.

FOB Destination Edwards AFB, CA 93524.

Period of Performance: 30 Days ARO

Information requested.

The Government requests interested offerors that can fully support this requirement furnish the following information:

1. Company name, DUNs number and Cage Code, address, points of contact, phone numbers and e-mail addresses.

2. Information should include a brief description of experience in providing the type of support described above. The information package must be clear, concise, and complete. The Air Force is under no obligation to provide feedback to the company, or to contact the company for clarification of any information submitted in response to this request.

3. Identification of business size (small or large) and identify the socioeconomic disadvantaged category, as defined the Federal Acquisition Regulation FAR Part 19 and also currently listed in the System for Award Management (SAM). Small business size standards are published by the U.S. Small Business Administration (SBA) and may be found at www.sba.gov/size/sizetable2002.html.

The potential Product Service Code is Z2AZ “Repair or Alteration of Other Administrative Facilities and Service Buildings”, and the North American Industry Classification System (NAICS) codes assigned to this procurement is 238330 “Flooring Contractors” and the Small Business Size Standard is $19,000,000.

http://www.sba.gov/size/sizetable2002.html

4. Any other information deemed useful to the Air Force. Information packages should be limited to no more than 1 pages.

Inquiries.

Any qualified and interested companies responding to this announcement must be able to support all areas. NO partial support responses from industry will be accepted.

Any inquiries are due on or before 25 April 2024 at 8:00am PDT. The due date and time for responses to this synopsis is 26 April 2024 at 2:30pm PDT on. Please send all responses via email to the Contracting Officer: Suzanna Kussman at suzanna.kussman@us.af.mil and the Contract Specialist: Kimberly McGee at kimberly.mcgee@us.af.mil.

mailto:suzanna.kussman@us.af.mil mailto:kimberly.mcgee@us.af.mil