Draft Specifications - REQT-IHS-2026-00225.pdf
PDF 144 KB Posted
- Solicitation number
- REQT-IHS-2026-00225
About this file
This is a Draft Specifications document for a Sources Sought Notice (REQT-IHS-2026-00225) issued by the Indian Health Service, Portland Area, for market research purposes and vendor feedback.
The Indian Health Service seeks annual licensing and Standard Maintenance and Support Services (MSS) for the Western Oregon Service Unit's AudioCARE automated patient telephone system, which has operated since 2011. The requirement covers one existing production environment for a base period (January 1, 2027–December 31, 2027) plus four one-year option periods through December 31, 2031. The contractor must provide eight specific software components: ACS-SO4 (base server supporting four telephone lines), AudioReminder, TMReminder, AudioRefill, AudioContact, ACS-TM-BASE (SMS platform with 120,000 annual text segments included), AudioCommunicator-STD (voice mass communications), and TMCommunicator (text mass communications). All components must be active, configured, tested, and fully operational on January 1, 2027, with no post-start implementation period. The system maintains interfaces with the Resource and Patient Management System (RPMS) for scheduling and pharmacy functions and processes appointment, prescription, refill, and contact information.
Standard MSS includes unlimited telephone support during business hours (8:00 AM–5:00 PM EST on business days), incident tracking through telephone, email, and Government-approved remote methods, replacement hardware within one business day of failure confirmation, application patches and supported updates, documentation, and remote installation and training for mass-communication applications. The contractor must identify covered components, hardware age, parts-availability limitations, and whether replacement parts, labor, shipping, and on-site work are included. Day-one acceptance requires demonstration of all licensed components, functioning refill and reminder capabilities, RPMS interfaces, operational voice and text mass communications, entitlement evidence, documentation, and completion of installation-related training. The system must maintain 24-hour patient access to refill requests (except during Government-approved maintenance), preserve patient preferences and opt-in/opt-out status, and provide seven days' advance notice of planned downtime. The requirement is for license and maintenance renewal only; migration to different platforms or separately chargeable work requires prior written Contracting Officer authorization. Performance will be monitored through license verification, incident and hardware-replacement records, functional testing, and SMS usage tracking.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| IHS-IEE-Representation-Form_Jan-2022.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
INDIAN HEALTH SERVICE | Portland Area Draft Specifications | REQT-IHS-2026-00225
1. Title Western Oregon Service Unit AudioCARE Automated Patient Telephone Refill, Appointment Reminder, and Mass Communication System - Annual License and Maintenance Support Renewal These draft specifications describe anticipated requirements for market research under Sources Sought Notice REQT-IHS-2026-00225. They are provided for vendor feedback and are not a solicitation.
2. Background The Western Oregon Service Unit (WOSU) has operated an AudioCARE automated patient telephone system since 2011 for prescription refill requests, appointment reminders, patient contact management, and pharmacy workload reporting. The system provides patients with 24-hour access to submit refill requests and records time-stamped refill workflow events.
The production environment exchanges appointment information with the Resource and Patient Management System (RPMS) scheduling package and prescription information with the RPMS pharmacy package. This follow-on requirement continues licensing, maintenance, and support without interruption and includes voice and text mass-communication capabilities for Government-approved notices.
3. Scope Provide annual licensing and Standard Maintenance and Support Services (MSS) for one existing production environment for a base year and four one-year option periods. Include all components in Section 4.1, covered AudioCARE server/equipment maintenance, application patches and supported updates, remote troubleshooting, configuration, testing, documentation, and installation-related training for the mass-communication applications.
All required licenses, modules, interfaces, and functions, including AudioCommunicator-STD and TMCommunicator, shall be active, configured, tested, and operational on January 1, 2027. No post-start implementation or phase-in period is contemplated. All required capabilities shall remain available throughout each exercised period, subject to approved maintenance and incident handling.
The requirement sustains and enhances the existing AudioCARE environment. It does not authorize migration to a different platform, unrelated systems, or separately chargeable work without prior written Contracting Officer authorization.
4. Specific Tasks or Specifications
4.1 Covered modules and capacity
Provide one license/coverage unit for each component below. The base server shall support four telephone lines. Software and text-message delivery fees for the annual SMS allowance shall be included.
Component Required function
ACS-SO4 Base AudioCARE server and telephony support for four telephone lines.
AudioReminder Automated appointment reminders by telephone.
TMReminder Automated appointment reminders by text message.
AudioRefill Prescription inquiry and refill requests by telephone.
AudioContact Patient contact management, opt-in/opt-out preferences, and contact-information verification and updates.
ACS-TM-BASE Base SMS platform, including software and delivery fees for up to 120,000 text-message segments per annual period.
AudioCommunicator-STD Voice mass communications, including approved operational notices, surveys, wellness messages, and recall notices.
TMCommunicator Text mass communications; software add-on to AudioCommunicator.
The six components from ACS-SO4 through ACS-TM-BASE are renewed components identified in the prior order. AudioCommunicator-STD and TMCommunicator are additional applications identified in the current requirement; both are required to be operational on day one of the base period.
The 120,000 annual SMS allowance is shared across the covered text-message applications. The quoted counting convention treats the first 160 characters as one segment and each additional 153 characters as another segment. Respondents shall identify any other encoding or segmentation rules, usage reporting, and rates for additional segments.
Usage above the included allowance requires prior Government authorization for any additional charge.
4.2 Operational capabilities and interfaces
- Maintain telephone refill access 24 hours per day, except during Government-approved maintenance windows or interruptions outside contractor control.
- Maintain appointment reminders, patient preferences, contact information, refill validation, time-stamped status tracking, workload reports, and existing RPMS scheduling and pharmacy interfaces.
- Enable Government-authorized voice and text campaigns, including recipient selection, preference handling, message processing, delivery/status reporting, and stop/cancellation controls as applicable.
4.3 Standard support and hardware maintenance
- Provide unlimited telephone support during standard business hours, 8:00 AM to 5:00 PM
Eastern Standard Time (EST), under Standard MSS. Respondents shall identify business days, holidays, daylight-saving treatment, support contacts, and escalation procedures.
- Accept and track incidents through telephone, email, and Government-approved remote methods. Diagnose reported failures, communicate status and workarounds, and document resolution.
- Provide replacement hardware/systems for covered failures within one business day after diagnosis and confirmation of hardware failure. This is a hardware-provision milestone; it does not establish a one-business-day diagnosis or full-service-restoration guarantee.
- Identify covered AudioCARE server, telephony hardware, and core application components. Identify hardware age, parts-availability limitations, and any exclusions for damage outside normal use, including power events or environmental damage.
- Identify whether replacement parts, labor, shipping, return shipping, on-site work, and travel are included. No additional charge or uncovered replacement is authorized without prior written Contracting Officer approval.
Respondents shall provide proposed initial-response and restoration targets by incident severity, escalation arrangements, and any on-site response commitment. Standard MSS is the anticipated support level. Twenty-four-hour emergency support and recurring remote refresher training shall not be represented as included unless expressly offered and accepted.
4.4 Software updates and change control
- Provide application patches and supported updates needed to maintain the covered
AudioCARE functions, operational compatibility, and application security. Include updates to user documentation, training aids, and voice recordings for approved operational changes.
- Coordinate changes with Government IT and pharmacy staff; test compatibility and functions before production deployment. For material changes, provide release information, test results, implementation steps, and a Government-approved recovery approach.
- Preserve existing RPMS interfaces and data integrity. Identify any custom programming, host-system modification, site merger, or other work excluded from Standard MSS; such additional work requires separate written authorization.
- Coordinate application compatibility with Government-managed firewall settings, operating-system security patches, and antivirus updates. The Government retains control of those infrastructure settings and approvals.
4.5 Training and documentation
Include remote installation, compatibility testing, telephone-based installation training, and complete documentation for the additional communication applications. Training shall enable designated staff to manage approved campaigns, patient preferences, reports, and campaign stop/cancellation controls before day-one operational acceptance.
Respondents shall identify the included number and duration of training sessions, participant capacity, materials, and any limits. Identify any separately priced on-site or recurring refresher training. No fixed quantity of recurring refresher or on-site training is assumed under Standard MSS.
5. Performance Monitoring The Government-designated technical representative will verify license entitlements and Standard MSS coverage at the start of each period and monitor support through incident records, hardware-replacement records, functional testing, and review of documentation and training completion.
- Verify each Section 4.1 component and required day-one capability, including voice and text mass communications.
- Test refill requests, appointment reminders, patient contact preferences, tracking, reports, and RPMS data exchange after material changes.
- Review SMS allowance and usage reports, reported incidents, escalation actions, replacement timing, and correction of deficiencies.
6. Security Requirements The system processes appointment, prescription, contact, and refill-status information.
Contractor personnel shall protect sensitive Government and patient information and comply with Federal, HHS, and IHS privacy and information security requirements identified by the Government.
- Limit access to authorized personnel with a valid need to know and the minimum privileges necessary. Use only approved accounts, authentication, remote-access methods, and support tools.
- Obtain approval for on-site access to the secure IT room and remote access to production systems. Shared accounts are prohibited unless expressly approved by the Government.
- Do not copy, retain, transmit, or remove patient or Government information outside authorized environments without written approval.
- Support application-security updates and vulnerability remediation, preserve relevant logs, and report suspected security/privacy incidents within the Government-designated timelines.
7. Government-Furnished Equipment and Information Subject to security controls, the Government will provide authorized access to the existing production system and covered server environment; available configuration and interface information, logs, maintenance history, and technical contacts; approved test data; and facility, network, and remote access needed for authorized work.
The Government will provide approved message content, recipient criteria, business rules, release authorization, maintenance windows, change-control procedures, and applicable policies. Contractor tools, personnel, support infrastructure, and incidental materials needed for included work shall be provided by the contractor.
8. Other Pertinent Information or Special Considerations Plan and perform work to minimize disruption to refill processing, appointment reminders, patient communications, and pharmacy operations. Coordinate testing, training, changes, and any approved on-site work with Government pharmacy and IT personnel.
- Do not change production systems or initiate patient communications without prior Government authorization.
- Preserve opt-in/opt-out preferences, contact information, workload reports, and time-stamped operational logs.
- Provide seven days advance notice of planned downtime, except emergency maintenance;
use Government-approved maintenance windows.
- Do not select recipients, author clinical content, or release patient messages except as specifically authorized by the Government.
a. Identification of Possible Follow-on Work The requirement includes four one-year options. Future hardware refresh, custom interface programming, expanded capacity, Premium MSS, or additional training may be considered separately. Exercise of options and authorization of additional work are not guaranteed.
b. Inspection and Acceptance Criteria Day-one acceptance requires active licenses and support for all covered components;
functioning refill, voice/text reminder, contact-management, tracking, reporting, and RPMS-interface capabilities; and operational voice and text mass communications. The contractor shall provide entitlement evidence, support contacts, documentation, and functional-test results.
The mass-communication functions shall pass a Government-approved test campaign by the start of the base period, including authorized recipients, patient preferences, message processing, status/log reporting, and stop/cancellation controls as applicable. Installation-related training shall be completed for designated staff. No deferred implementation period is included.
Subsequent updates and covered maintenance shall preserve required functions and pass applicable checks. Deficiencies shall be corrected within the agreed service commitments or another timeframe accepted in writing by the Contracting Officer or authorized representative. Acceptance does not waive applicable warranty rights.
9. Risk Control Prevent coverage lapses through renewal verification before each period starts. Manage service interruptions through documented escalation, agreed response/restoration targets, approved remote access, and the covered hardware-replacement commitment. Confirm equipment age and parts availability before award, because the Standard MSS terms identify limitations for systems beyond their four-year technical life.
Reduce update and security risks through approved access, testing, recovery procedures, and coordinated maintenance. Monitor SMS consumption and obtain authorization before incurring excess-usage charges. Verify day-one readiness of both additional communication applications before accepting performance.
10. Place of Performance Primary support shall be provided remotely through Government-approved methods. Any authorized on-site troubleshooting, repair, testing, inspection, or training will occur at:
Chemawa Indian Health Center Western Oregon Service Unit 3750 Chemawa Road NE Salem, OR 97305
11. Period of Performance The anticipated base period and four one-year option periods are:
Period Start date End date
Base period January 1, 2027 December 31, 2027
Option year 1 January 1, 2028 December 31, 2028
Option year 2 January 1, 2029 December 31, 2029
Option year 3 January 1, 2030 December 31, 2030
Option year 4 January 1, 2031 December 31, 2031
Total potential duration is five years if all options are exercised. Options require written Government exercise and are not guaranteed.
12. Delivery and Performance Schedule Milestone Required timing
Base-period readiness All required licensing, Standard MSS, modules, interfaces, and functions operational on January 1, 2027.
Mass communications and training
Voice/text capabilities configured and tested, required documentation delivered, and installation-related training completed by the base-period start.
Option-period continuity Renew licenses, SMS allowance, and maintenance coverage effective January 1 of each exercised option, through December 31 of the same year.
Covered hardware failure Replacement hardware/systems provided within one business day after diagnosis and confirmation of the covered failure.
Other incidents and updates
Follow the service commitments established in the award and Government-approved change/maintenance schedules.
Respondents shall identify any inability to meet the required day-one schedule and explain proposed support commitments or exclusions in their capability statements.
| 4.1 Covered modules and capacity |
| 4.2 Operational capabilities and interfaces |
| 4.3 Standard support and hardware maintenance |
| 4.4 Software updates and change control |
| 4.5 Training and documentation |
| a. Identification of Possible Follow-on Work |
| b. Inspection and Acceptance Criteria |
File details come from the government source that posted it. Updated .