Reiner_StatementOfWork_ReglassingReactorAgitator.pdf

PDF 71 KB Posted

Attached to
Notice of Intent to Sole Source: DeDietrich Agitator Repair for SA1500 Reactor.
Solicitation number
1176190
Issued by

About this file

This is a Statement of Work for the USDA Forest Service Forest Products Laboratory detailing the repair and reinstallation of a DeDietrich agitator for an SA1500 glass-lined reactor. The contractor shall receive a damaged glass-lined agitator, inspect it for repairability, and if confirmed, remove all glass, repair the underlying steel structure, reglass according to original 2012 specifications, confirm reglassing integrity, ship to the Forest Products Laboratory, send a service engineer for installation with a new cartridge seal, and confirm final glass integrity. The work takes place in Building 29 of the Forest Products Laboratory. The reactor operates in a concentrated sulfuric acid environment (64% at 45°C) used to quench cellulose nanocrystal reactions, followed by bleaching with chlorine dioxide and neutralization with concentrated sodium hydroxide.

The contractor shall provide a service report detailing installation and glass integrity confirmation as the primary deliverable. The government will assist with installation and ensure the equipment's working order. The contractor is responsible for all travel arrangements and determining necessary staffing levels. Service technicians will be escorted while on-site due to security requirements. The contractor retains no rights to data generated except for the service report containing installation notes. Section 508 electronic and information technology standards are not applicable to this work.

View the file

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Statement of Work

Project USDA FS Forest Products Laboratory – DeDietrich agitator repair for SA1500 Reactor

General Information

1.0 Scope of Work

The contractor shall repair, reglass and install an agitator for a 1500-gallon glass-lined reactor.

2.0 Background

The Forest Products Laboratory has an ongoing need to produce and supply cellulose nanomaterials for research and development for government, university and corporate researchers in the United States and worldwide. Their production requires operating within a concentrated acid environment, as well as, working with strong oxidants. This glass-lined reactor is used to quench a cellulose nanocrystal reaction performed at 64% sulfuric acid at a temperature of 45C. The crude material is bleached with chlorine dioxide and then neutralized with concentrated sodium hydroxide solution.

Contractor Requirements

3.0 Technical Requirements / Tasks

The contractor shall receive a damaged glass-lined agitator and inspect to confirm repairability. If confirmed, the contractor shall remove all glass from the agitator, make repairs to underlying steel structure, reglass according to the specifications of the original 2012 purchase, confirm integrity of the reglassing, ship to FPL, send a service engineer to carry out installation with a new cartridge seal, and finally confirm glass integrity.

4.0 Government Furnished

The government will work with the service engineer and assist with the installation and ensure the working order of the government-owned SA-1500. The work will take place in building 29 of the Forest Products Laboratory.

5.0 Deliverables / Schedule

The contractor shall provide a service report detailing the install and confirmation of the glass integrity.

6.0 Travel

The contractor will make all their own travel arrangements.

7.0 Contractor’s Key Personnel

Contractor shall determine the number of people required to accomplish the deliverables.

8.0 Security Requirements

The service technician will be escorted when on-site.

9.0 Data Rights

The contractor shall have no right to any data generated, except for the service report detailing the installation notes.

10.0 Section 508 – Electronic and Information Technology Standards Not Applicable.

Attachment If applicable, include an Attachment stating Evaluation Factors and significant Subfactors representing the key areas of importance and emphasis to be considered in the source selection decision.

File details come from the government source that posted it. Updated .