This document contains salient characteristics and detailed specifications for a Range Tower required by Marine Corps Recruit Depot Parris Island under solicitation M0026326QD010. The tower is a 6-foot by 6-foot nominal interior structure designed to overlook firing lines during live fire training operations. The structure features an 80-inch ceiling height, diamond-embossed clear anodized aluminum exterior and interior finishes, with R-10 insulation on all walls, floor, and ceiling. The roof utilizes standard Duraluminum construction with a 12-inch overhang and 4-inch fascia, incorporating a 6-inch by 24-inch minimum footing capable of supporting 50 pounds of roof-mounted equipment.

The tower includes fixed front and side windows with mirror-plane glazing and tinted finishes, a swing door with half glass and clear aluminum finish, and ADA-compliant hardware. Climate control is provided by a 115-volt, 10,100 BTU cooling/11,200 BTU heating through-wall HVAC system. Electrical infrastructure includes a 100-amp, 30-amp single-phase, 12-circuit load center with main breaker, 115-volt duplex outlets (interior and weatherproof exterior), and a 1.5-inch conduit system for future equipment installation. Lighting comprises a 64-watt 2-foot LED wraparound fixture, single-head exterior flood lights on three sides, and three downrange-directed LED lights or one 3-foot LED light bar, with exterior strobe/warning lights on the roof. The tower is mounted on a tandem-axle trailer with rear landing, 12-foot by 12-foot footprint, dual tow bars with fixed stairs, and front/rear pintle hitch mounts enabling 360-degree rotation. Additional features include leveling jacks on all four corners, ground tie-down points, a 3-foot high by 6-foot by 6-foot under-building storage compartment, 2.5-foot by 2-foot-5-inch front storage area, 4-foot exterior canopy, and wide-dispersion horn loudspeakers. Dimensional tolerances allow ±2 inches for feet measurements and ±0.5 inches for inch measurements, with electrical specifications within ±10 volts of stated requirements.

View the file

Other files

File Type Posted
Solicitation - M0026326QD010.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

RANGE TOWER SPECIFICATIONS

(The following are specicification of our current Range Tower)

Interior Dimensions (6' x 6' Nominal) Ceiling Height: 80" (+ / -1”) Exterior Finishes Diamond Embossed Clear Anodized Aluminum Exterior Interior Finishes Diamond Embossed Clear Anodized Aluminum Interior Insulation on all walls, floor, ceiling. Walls R-10, Ceiling R-10. R-10 Floor Insulation Roof Standard Duraluminum Roof w/ 12" Overhang, 4'' Fascia Height (2x) Mounting point to support 50 LBS on top of roof, 6”x24” minimum footing Floor Structure Aluminum Tread Plate Floor Standard 6'' x 12'' Floor Access Cutout Window(s) Front window shall have mirror plane glazing, tinted. Fixed and immovable Side windows shall have mirror pane glazing, tinted. Heavy duty window frame. Horizontal slide to open and close front and back.

Mirrorpane Door(s) Swing Door Half Glass, Clear And Alum Finish ADA Dormitory Style Lock with Dead Bolt ADA Hydraulic Closer Climate Control 115V 10,100C / 11,200H BTU Thru Wall HVAC Electric 100A, (30A) Single Phase, 12 Circuit Load Center with Main Breaker 115V Duplex Outlet 115V Exterior Weatherproof Duplex Outlet RUGGED / Outdoor capable Power Cord (Configuration to match existing power) - 1 EA (on left side of tower) External generator receptacle Wall Switch

1.5 inch conduit ran along floor in the corners and form the floor to the ceiling to allow for future equipment installation.

Weatherproof Wall Switch 64 Watt - 1 EA 2’ LED Wraparound Light Fixture Single Head Exterior Flood Light Exterior: (1) LED Flood light on the rear, right, and left side. (3) LED Flood Lights that will point down range separate from the other lights or (1) 3ft LED Light bar that will point down range.

Exterior Strobe Light/Warning Light on roof Blank 2"x4" Junction Box with Surface Mounted Conduit Run & Pull Wire Exterior Blank 2"x4" Junction Box with Surface Mounted Conduit Run & Pull Wire Custom Electrical (Update routing of cables, proper water sealing for system, and 10 outlets) Grounding Rod Misc. Accessories 22" Deep Painted Steel Shelf Tandem Axle Trailer with Rear Landing 12”x12” feet, single tow bar, and fixed stairs. Front and rear pintle hitch mount allowing for tow from both ends of the trailer. 360-degree ability to turn. Stable legs (leveling jack) on all four corners with feet that are no smaller than 1ftx1ft.

Tie down points on all four corners to secure to ground during high winds.

Custom 3' High x 6' x 6' Storage Compartment Under Building with Hinged Doors on Both Sides 2.5' x 2'5' x 6' Front Storage Area 4' Canopy for Exterior of Booth to be Mounted to booth On-Site Wide Dispersion Horn Loudspeakers to mount on roof Misc. Material All dimensions in feet may have ± 2” of variance. All dimensions in inches may have ± 0.5” of variance. All volts may be within ±10 of specified requirements.