This document is a Request for Quote (RFQ) from the Lorain Correctional Institution for upgrades to Firing Range 2, located at GCI in Grafton, Ohio. The project involves constructing a 12' x 48' x 8' post frame shelter with a 4/12 pitch gabled roof, fully enclosed on both gable ends and one long side. The shelter will include a white metal ceiling, a 36" walk-through door with keyed entry on the north gable end, and an attached 12' x 8' lean-to. Concrete work includes a 4" slab with 3" gravel base in both the shelter and lean-to, with wire reinforcement and a smooth finish. Additionally, the project requires an 80' x 80' concrete pad with similar specifications and minor excavation for site preparation.

The project scope includes specific construction details such as 2" x 6" fascia, 5" gutters with downspouts, and is located near OH-83 in Grafton, OH. The RFQ includes three supporting images (image1.png, image2.png, image3.png) that likely provide visual context for the proposed shelter and site location. No specific pricing, funding sources, or contract term details are provided in the document. The focus appears to be on precise technical specifications for the range shelter construction at the correctional facility.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Lorain Correctional Institution Request for quote for the following upgrades at firing range 2 located at GCI.

12’ x 48’ x 8’ Post frame shelter 4/12 pitch gabled roof Walls enclosed on both gable ends and 1 long side White metal ceiling in shelter, none in lean-to Solid 36” walk-through door with keyed entry knob on North gable end leading to a fully enclosed attached 12’ x 8’ lean-to 4” concrete in shelter and lean-to, 3” gravel base, wire reinforcement, smooth finish, cut, and sealed.

2” x 6” fascia, wrapped 5” gutters with downspout 80’ x 80’ concrete pad, 4” concrete, 3” gravel base, wire reinforcement, broomed or similar finish, cut, and sealed Minor excavation may be needed to prep and level area.

Approximate location just off of OH-83 in Grafton, OH, highlighted in pink: