Quote Submission Form_PCC for ERDC GSL.pdf
PDF 85 KB Posted
- Attached to
- Production of PCC Pavement Model for ERDC GSL
- Solicitation number
- W912HZ21Q4710
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Performance Work Statement_PCC for ERDC GSL.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
QUOTE SUBMISSION FORM
Production of PCC Pavement Model for ERDC GSL
Engineer Research and Development Center
ATTN: Angie Stokes
3909 Halls Ferry Rd.
Vicksburg, Mississippi 39180-6199
EMAIL: Angela.M.Stokes@usace.army.mil
601-634-4878
Item
No.
Description Price
Concrete Mixture Design, to include (Reference the Performance Work Statement for further detail):
Minimum design compressive strength of 5,000 psi at 28 days when tested in accordance with
ASTM C39
Minimum design tensile strength of 650 psi at 28 days when tested in accordance with ASTM C78
0.45 maximum allowable water-cementitious material ratio
Size 67 or larger (e.g., Size 57) limestone aggregate per ASTM C33
Target slump shall be 7 ± 1 in
*The concrete mixture design shall be submitted for approval by the Engineer at least two weeks prior to placement. No concrete shall be placed without an approved mixture design.
Concrete Placement, to include (Reference the
Performance Work Statement for further detail):
Fixed-form placement method
Pump-truck placement
Contractor shall be responsible for the supply, installation, removal, and disposal of all formwork
Forms shall be structurally sufficient and adequately staked/reinforced
Release agent to facilitate removal of forms mailto:Angela.M.Stokes@usace.army.mil
Dowel bar assemblies shall be placed at the locations indicated in Figure 1 in the Performance
Work Statement
Fresh concrete shall meet the slump requirements of 7 ± 1 in
Delivered concrete temperatures must be less than
90°F when tested in accordance with ASTM
C1064
Water shall not be in excess of batch water.
Reference Item I under Concrete Placement in the Performance Work Statement
Self-powered, vibratory truss screed is required
Finishing and Curing:
1 – Textured broom finish is required
2 – Fogging/misting is allowed
3 – CRD-300 curing compound is to be applied
Construction and Contraction Joints:
1 – All contraction joints MUST undergo initial saw cutting within 6 to 12 hours after placement
2 – Saw cutting is not required for construction joints
3 – Joint sealant is required for the model for the contract joints
TOTAL COST
1. REGISTERED IN THE SYSTEM FOR AWARD MANAGEMENT (SAM)?
YES _________ NO __________
NOTE: If you are not registered with SAM (formerly CCR), an award cannot be made to your institution. You may register electronically at https://www.sam.gov/portal/public/SAM/.
Registering electronically will expedite the registration process but may not ensure registration prior to the award of the contract.
2. PLEASE PROVIDE THE FOLLOWING INFORMATION:
Contractor/Vendor Name: ______________________________________________________
Contractor DUNS #: ___________________________________________________________
Contractor Cage Code: _________________________________________________________ http://www.sam.gov/portal/public/SAM/ http://www.sam.gov/portal/public/SAM/
Contractor Tax ID: ____________________________________________________________
Contractor Point of Contact: _____________________________________________________
Point of Contact Phone Number: _________________________________________________
Point of Contact E-mail Address: _________________________________________________
This quote is valid through the following date: ______________________________________
File details come from the government source that posted it. Updated .